Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONE ALGORITHMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON): A statistical model based iterative image reconstruction method to eliminate limited-view artifacts and to mitigate the temporal-average artifacts in time-resolved CT

Purpose: In x-ray computed tomography (CT), a violation of the Tuy data sufficiency condition leads to limited-view artifacts. In some applications, it is desirable to use data corresponding to a narrow temporal window to reconstruct images with reduced temporal-average artifacts. However, the need to reduce temporal-average artifacts in practice may result in a violation of the Tuy condition and thus undesirable limited-view artifacts. In this paper, the authors present a new iterative reconstruction method, synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON), to eliminate limited-view artifacts using data acquired within an ultranarrow temporal window that severely violates the Tuy condition. Methods: In time-resolved contrast enhanced CT acquisitions, image contrast dynamically changes during data acquisition. Each image reconstructed from data acquired in a given temporal window represents one time frame and can be denoted as an image vector. Conventionally, each individual time frame is reconstructed independently. In this paper, all image frames are grouped into a spatial–temporal image matrix and are reconstructed together. Rather than the spatial and/or temporal smoothing regularizers commonly used in iterative image reconstruction, the nuclear norm of the spatial–temporal image matrix is used in SMART-RECON to regularize the reconstruction of all image time frames. This regularizer exploits the low-dimensional structure of the spatial–temporal image matrix to mitigate limited-view artifacts when an ultranarrow temporal window is desired in some applications to reduce temporal-average artifacts. Both numerical simulations in two dimensional image slices with known ground truth and in vivo human subject data acquired in a contrast enhanced cone beam CT exam have been used to validate the proposed SMART-RECON algorithm and to demonstrate the initial performance of the algorithm. Reconstruction errors and temporal fidelity of the reconstructed images were quantified using the relative root mean square error (rRMSE) and the universal quality index (UQI) in numerical simulations. The performance of the SMART-RECON algorithm was compared with that of the prior image constrained compressed sensing (PICCS) reconstruction quantitatively in simulations and qualitatively in human subject exam. Results: In numerical simulations, the 240{sup ∘} short scan angular span was divided into four consecutive 60{sup ∘} angular subsectors. SMART-RECON enables four high temporal fidelity images without limited-view artifacts. The average rRMSE is 16% and UQIs are 0.96 and 0.95 for the two local regions of interest, respectively. In contrast, the corresponding average rRMSE and UQIs are 25%, 0.78, and 0.81, respectively, for the PICCS reconstruction. Note that only one filtered backprojection image can be reconstructed from the same data set with an average rRMSE and UQIs are 45%, 0.71, and 0.79, respectively, to benchmark reconstruction accuracies. For in vivo contrast enhanced cone beam CT data acquired from a short scan angular span of 200{sup ∘}, three 66{sup ∘} angular subsectors were used in SMART-RECON. The results demonstrated clear contrast difference in three SMART-RECON reconstructed image volumes without limited-view artifacts. In contrast, for the same angular sectors, PICCS cannot reconstruct images without limited-view artifacts and with clear contrast difference in three reconstructed image volumes. Conclusions: In time-resolved CT, the proposed SMART-RECON method provides a new method to eliminate limited-view artifacts using data acquired in an ultranarrow temporal window, which corresponds to approximately 60{sup ∘} angular subsectors.

60 APPLIED LIFE SCIENCES↗

Combining prior day contours to improve automated prostate segmentation

Purpose: To improve the accuracy of automatically segmented prostate, rectum, and bladder contours required for online adaptive therapy. The contouring accuracy on the current image guidance [image guided radiation therapy (IGRT)] scan is improved by combining contours from earlier IGRT scans via the simultaneous truth and performance level estimation (STAPLE) algorithm. Methods: Six IGRT prostate patients treated with daily kilo-voltage (kV) cone-beam CT (CBCT) had their original plan CT and nine CBCTs contoured by the same physician. Three types of automated contours were produced for analysis. (1) Plan: By deformably registering the plan CT to each CBCT and then using the resulting deformation field to morph the plan contours to match the CBCT anatomy. (2) Previous: The contour set drawn by the physician on the previous day CBCT is similarly deformed to match the current CBCT anatomy. (3) STAPLE: The contours drawn by the physician, on each prior CBCT and the plan CT, are deformed to match the CBCT anatomy to produce multiple contour sets. These sets are combined using the STAPLE algorithm into one optimal set. Results: Compared to plan and previous, STAPLE improved the average Dice's coefficient (DC) with the original physician drawn CBCT contours to a DC as follows: Bladder: 0.81 {+-} 0.13, 0.91 {+-} 0.06, and 0.92 {+-} 0.06; Prostate: 0.75 {+-} 0.08, 0.82 {+-} 0.05, and 0.84 {+-} 0.05; and Rectum: 0.79 {+-} 0.06, 0.81 {+-} 0.06, and 0.85 {+-} 0.04, respectively. The STAPLE results are within intraobserver consistency, determined by the physician blindly recontouring a subset of CBCTs. Comparing plans recalculated using the physician and STAPLE contours showed an average disagreement less than 1% for prostate D98 and mean dose, and 5% and 3% for bladder and rectum mean dose, respectively. One scan takes an average of 19 s to contour. Using five scans plus STAPLE takes less than 110 s on a 288 core graphics processor unit. Conclusions: Combining the plan and all prior days via the STAPLE algorithm to produce treatment day contours is superior to the current standard of deforming only the plan contours to the daily CBCT. STAPLE also improves the precision, with a substantial decrease in standard deviation, a key for adaptive therapy. Geometrically and dosimetrically accurate contours can be automatically generated with STAPLE on prostate region kV CBCT in a time scale suitable for online adaptive therapy.

60 APPLIED LIFE SCIENCES↗

Path planning algorithms for assembly sequence planning

Planning for manipulation in complex environments often requires reasoning about the geometric and mechanical constraints which are posed by the task. In planning assembly operations, the automatic generation of operations sequences depends on the geometric feasibility of paths which permit parts to be joined into subassemblies. Feasible locations and collision-free paths must be present for part motions, robot and grasping motions, and fixtures. This paper describes an approach to reasoning about the feasibility of straight-line paths among three-dimensional polyhedral parts using an algebra of polyhedral cones. A second method recasts the feasibility conditions as constraints in a nonlinear optimization framework. Both algorithms have been implemented and results are presented.

Krishnan, S. S.↗

SU-E-T-629: Feasibility Study of Treating Multiple Brain Tumors with Large Number of Noncoplanar IMRT Beams

Purpose: To study the feasibility of treating multiple brain tumors withlarge number of noncoplanar IMRT beams. Methods: Thirty beams are selected from 390 deliverable beams separated by six degree in 4pi space. Beam selection optimization is based on a column generation algorithm. MLC leaf size is 2 mm. Dose matrices are calculated with collapsed cone convolution and superposition method in a 2 mm by 2mm by 2 mm grid. Twelve brain tumors of various shapes, sizes and locations are used to generate four plans treating 3, 6, 9 and 12 tumors. The radiation dose was 20 Gy prescribed to the 100% isodose line. Dose Volume Histograms for tumor and brain were compared. Results: All results are based on a 2 mm by 2 mm by 2 mm CT grid. For 3, 6, 9 and 12 tumor plans, minimum tumor doses are all 20 Gy. Mean tumor dose are 20.0, 20.1, 20.1 and 20.1 Gy. Maximum tumor dose are 23.3, 23.6, 25.4 and 25.4 Gy. Mean ventricles dose are 0.7, 1.7, 2.4 and 3.1 Gy.Mean subventricular zone dose are 0.8, 1.3, 2.2 and 3.2 Gy. Average Equivalent uniform dose (gEUD) values for tumor are 20.1, 20.1, 20.2 and 20.2 Gy. The conformity index (CI) values are close to 1 for all 4 plans. The gradient index (GI) values are 2.50, 2.05, 2.09 and 2.19. Conclusion: Compared with published Gamma Knife treatment studies, noncoplanar IMRT treatment plan is superior in terms of dose conformity. Due to maximum limit of beams per plan, Gamma knife has to treat multiple tumors separately in different plans. Noncoplanar IMRT plans theoretically can be delivered in a single plan on any modern linac with an automated couch and image guidance. This warrants further study of using noncoplanar IMRT as a viable treatment solution for multiple brain tumors.

60 APPLIED LIFE SCIENCES↗

ERS-1 scatterometer calibration and validation activities at ECMWF. B: From radar backscatter characteristics to wind vector solutions

Calibration and validation activities for the ERS-1 scatterometer were carried out at ECMWF (European Center for Medium range Weather Forecast) complementary to the 'Haltenbanken' field campaign off the coast of Norway. At a Numerical Weather Prediction (NWP) center a wealth of verifying data is available both in time and space. This data is used to redefine the wind retrieval procedure given the instrumental characteristics. It was found that a maximum likelihood estimation procedure to obtain the coefficients of a reformulated sigma deg to wind relationship should use radar measurements in logarithmic rather than physical space, and use winds as the wind components rather than wind speed and direction. Doing this, a much more accurate transfer function than the one currently operated by ESA was derived. Sigma deg measurement space shows no signature of a separation in an upwind solution cone and a downwind solution cone. As such signature was anticipated in ESA's wind direction ambiguity removal algorithm, reconsideration of the procedure is necessary. Despite the fact that revisions have to be made in the process of wind retrieval; a grid potential is shown for scatterometry in meteorology and climatology.

Stoffelen, AD↗

A new method for recognizing quadric surfaces from range data and its application to telerobotics and automation, final phase

In the final phase of the proposed research a complete top to down three dimensional object recognition scheme has been proposed. The various three dimensional objects included spheres, cones, cylinders, ellipsoids, paraboloids, and hyperboloids. Utilizing a newly developed blob determination technique, a given range scene with several non-cluttered quadric surfaces is segmented. Next, using the earlier (phase 1) developed alignment scheme, each of the segmented objects are then aligned in a desired coordinate system. For each of the quadric surfaces based upon their intersections with certain pre-determined planes, a set of distinct features (curves) are obtained. A database with entities such as the equations of the planes and angular bounds of these planes has been created for each of the quadric surfaces. Real range data of spheres, cones, cylinders, and parallelpipeds have been utilized for the recognition process. The developed algorithm gave excellent results for the real data as well as for several sets of simulated range data.

Mielke, Roland↗

Image Mission Attitude Support Experiences

The spin-stabilized Imager for Magnetopause to Aurora Global Exploration (IMAGE) is the National Aeronautics and Space Administration's (NASA's) first Medium-class Explorer Mission (MIDEX). IMAGE was launched into a highly elliptical polar orbit on March 25, 2000 from Vandenberg Air Force Base, California, aboard a Boeing Delta II 7326 launch vehicle. This paper presents some of the observations of the flight dynamics analyses during the launch and in-orbit checkout period through May 18, 2000. Three new algorithms - one algebraic and two differential correction - for computing the parameters of the coning motion of a spacecraft are described and evaluated using in-flight data from the autonomous star tracker (AST) on IMAGE. Other attitude aspects highlighted include support for active damping consequent upon the failure of the passive nutation damper, performance evaluation of the AST, evaluation of the Sun sensor and magnetometer using AST data, and magnetometer calibration.

Ottenstein, N.↗

Application of the multigrid solution technique to hypersonic entry vehicles

A multigrid solution procedure has been incorporated in a version of the Langley Aerothermodynamic Upwind Relaxation Algorithm. The multigrid scheme is based on the Full Approximation Storage approach and uses Full Multigrid to obtain a well defined fine mesh starting solution. Predictions were obtained using standard transfer operators and a 'V-cycle' was used to control grid sequencing. Computed hypersonic flow solutions compared with experimental data for a 15 degree sphere cone, blended-wing body, and shuttle-like geometries are presented. It is shown that the algorithm accurately predicts heating rates, and when compared with the single grid algorithm computes solutions in one-third the computational time.

Greene, Francis A.↗

SU-E-J-167: Improvement of Time-Ordered Four Dimensional Cone-Beam CT; Image Mosaicing with Real and Virtual Projections

Purpose: In the previous study, we developed time-ordered fourdimensional (4D) cone-beam CT (CBCT) technique to visualize nonperiodic organ motion, such as peristaltic motion of gastrointestinal organs and adjacent area, using half-scan reconstruction method. One important obstacle was that truncation of projection was caused by asymmetric location of flat-panel detector (FPD) in order to cover whole abdomen or pelvis in one rotation. In this study, we propose image mosaicing to extend projection data to make possible to reconstruct full field-of-view (FOV) image using half-scan reconstruction. Methods: The projections of prostate cancer patients were acquired using the X-ray Volume Imaging system (XVI, version 4.5) on Synergy linear accelerator system (Elekta, UK). The XVI system has three options of FOV, S, M and L, and M FOV was chosen for pelvic CBCT acquisition, with a FPD panel 11.5 cm offset. The method to produce extended projections consists of three main steps: First, normal three-dimensional (3D) reconstruction which contains whole pelvis was implemented using real projections. Second, virtual projections were produced by reprojection process of the reconstructed 3D image. Third, real and virtual projections in each angle were combined into one extended mosaic projection. Then, 4D CBCT images were reconstructed using our inhouse reconstruction software based on Feldkamp, Davis and Kress algorithm. The angular range of each reconstruction phase in the 4D reconstruction was 180 degrees, and the range moved as time progressed. Results: Projection data were successfully extended without discontinuous boundary between real and virtual projections. Using mosaic projections, 4D CBCT image sets were reconstructed without artifacts caused by the truncation, and thus, whole pelvis was clearly visible. Conclusion: The present method provides extended projections which contain whole pelvis. The presented reconstruction method also enables time-ordered 4D CBCT reconstruction of organs with non-periodic motion with full FOV without projection-truncation artifacts. This work was partly supported by the JSPS Core-to-Core Program(No. 23003). This work was partly supported by JSPS KAKENHI 24234567.

60 APPLIED LIFE SCIENCES↗

Iterative reconstruction techniques for industrial CT: application and performance

BWXT Y-12, Oak Ridge National Laboratory, and the University of Tennessee have been working toward improved high-resolution X-ray computed tomography for non-destructive testing of manufactured objects. The emphasis of this work has been on iterative reconstruction, calibration, and performance testing. Algebraic reconstruction algorithms for CT have been developed that are more robust in handling incomplete and noisy data and permit high-resolution volumetric imaging on metallic part assemblies. A key source of artifacts in reconstructed CT images for industrial components is poor image statistics due to areas of high attenuation. This loss of information in the captured projections not only affects reconstruction of those areas, but also the surrounding regions. To overcome numerical instabilities arising from the ill-posed nature of inverse problems, standard regularization techniques can be applied as can Bayesian reconstruction techniques using prior data such as CAD information to improve image quality. To accelerate the reconstruction of certain regions of interest and reduce memory requirements, subvolume reconstruction has been implemented and tested. A computational framework has been implemented that facilitates the use of sophisticated iterative algorithms for reconstruction of three-dimensional images from high-resolution X-ray cone-beam projection data. The code supports parallel computing at two levels: message passing is used to farm the computation out across a network of computers while threads allow all processors available on any one computer to be used.

99 GENERAL AND MISCELLANEOUS↗

Simplified calculation of solar flux distribution on the side wall of cylindrical cavity solar receivers

A simple solar flux calculation algorithm for a cylindrical cavity type solar receiver has been developed and implemented on an IBM PC-AT. Using cone optics, the contour error method is utilized to handle the slope error of a paraboloidal concentrator. The flux distribution on the side wall is calculated by integration of the energy incident from cones emanating from all the differential elements on the concentrator. The calculations are done for any set of dimensions and properties of the receiver and the concentrator, and account for any spillover on the aperture plate. The results of this algorithm compared excellently with those predicted by more complicated programs. Because of the utilization of axial symmetry and overall simplification, it is extremely fast. It can be esily extended to other axisymmetric receiver geometries.

Bhandari, P.↗

GPU-accelerated regularized iterative reconstruction for few-view cone beam CT

Purpose: The present work proposes an iterative reconstruction technique designed for x-ray transmission computed tomography (CT). The main objective is to provide a model-based solution to the cone-beam CT reconstruction problem, yielding accurate low-dose images via few-views acquisitions in clinically acceptable time frames. Methods: The proposed technique combines a modified ordered subsets convex (OSC) algorithm and the total variation minimization (TV) regularization technique and is called OSC-TV. The number of subsets of each OSC iteration follows a reduction pattern in order to ensure the best performance of the regularization method. Considering the high computational cost of the algorithm, it is implemented on a graphics processing unit, using parallelization to accelerate computations. Results: The reconstructions were performed on computer-simulated as well as human pelvic cone-beam CT projection data and image quality was assessed. In terms of convergence and image quality, OSC-TV performs well in reconstruction of low-dose cone-beam CT data obtained via a few-view acquisition protocol. It compares favorably to the few-view TV-regularized projections onto convex sets (POCS-TV) algorithm. It also appears to be a viable alternative to full-dataset filtered backprojection. Execution times are of 1–2 min and are compatible with the typical clinical workflow for nonreal-time applications. Conclusions: Considering the image quality and execution times, this method may be useful for reconstruction of low-dose clinical acquisitions. It may be of particular benefit to patients who undergo multiple acquisitions by reducing the overall imaging radiation dose and associated risks.

60 APPLIED LIFE SCIENCES↗

Cerenkov radio pulses from electromagnetic showers in the time domain

The electric field of the Cerenkov radio pulse produced by a single charged particle track in a dielectric medium is derived from first principles. An algorithm is developed to obtain the pulse in the time domain for numerical calculations. The algorithm is implemented in a Monte Carlo simulation of electromagnetic showers in dense media (specifically designed for coherent radio emission applications) as might be induced by interactions of ultrahigh energy neutrinos. The coherent Cerenkov radio emission produced by such showers is obtained simultaneously both in the time and frequency domains. A consistency check performed by Fourier transforming the pulse in time and comparing it to the frequency spectrum obtained directly in the simulations yields, as expected, fully consistent results. The reversal of the time structure inside the Cerenkov cone and the signs of the corresponding pulses are addressed in detail. The results, besides testing algorithms used for reference calculations in the frequency domain, shed new light into the properties of the radio pulse in the time domain. The shape of the pulse in the time domain is directly related to the depth development of the excess charge in the shower and its width to the observation angle with respect to the Cerenkov direction. This information can be of great practical importance for interpreting actual data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Four-Dimensional Image Registration for Image-Guided Radiotherapy

Purpose: Newly emerged four-dimensional (4D) imaging techniques such as 4D-computed tomography (CT), 4D-cone beam CT, 4D-magnetic resonance imaging, and 4D-positron emission tomography are effective tools to reveal the spatiotemporal details of patients' anatomy. To use the 4D data acquired under different conditions or using different modalities, an algorithm for registering 4D images must be in place. We developed an automated 4D-4D registration method to take advantage of 4D information. Methods and Materials: We used 4D-4D matching to find the appropriate three-dimensional anatomy in the fixed image for each phase of the moving image and spatially register them. A search algorithm was implemented to simultaneously find the best phase and spatial match of two 4D inputs. An interpolation scheme capable of deriving an image set based on temporally adjacent three-dimensional data sets was developed to deal with the situation in which the discrete temporal points of the two inputs do not coincide or correspond. Results: In a phantom study, our technique was able to reproduce the known 'ground truth' with high spatial fidelity. The technique regenerated all deliberately introduced 'missing' three-dimensional images at different phases of the input using temporal interpolation. In the registration of gated-magnetic resonance imaging and 4D-CT, the algorithm was able to select the appropriate CT phase. The technique was also able to register 4D-CT with 4D-cone beam CT and two 4D-CT scans acquired at different times. A spatial accuracy of <3 mm was achieved in 98% of voxels in all cases. Conclusion: Automated 4D-4D registration can find the best possible spatiotemporal match between two 4D data sets and is useful for image-guided radiotherapy applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computation of the inviscid supersonic flow about cones at large angles of attack by a floating discontinuity approach

The technique of floating shock fitting is adapted to the computation of the inviscid flowfield about circular cones in a supersonic free stream at angles of attack that exceed the cone half-angle. The resulting equations are applicable over the complete range of free-stream Mach numbers, angles of attack and cone half-angles for which the bow shock is attached. A finite difference algorithm is used to obtain the solution by an unsteady relaxation approach. The bow shock, embedded cross-flow shock, and vortical singularity in the leeward symmetry plane are treated as floating discontinuities in a fixed computational mesh. Where possible, the flowfield is partitioned into windward, shoulder, and leeward regions with each region computed separately to achieve maximum computational efficiency. An alternative shock fitting technique which treats the bow shock as a computational boundary is developed and compared with the floating-fitting approach. Several surface boundary condition schemes are also analyzed.

Daywitt, J.↗

Thermochemical nonequilibrium issues for earth reentry of Mars mission vehicles

The thermochemical environment about an axisymmetric 60-deg sphere-cone with a circular aft skirt is computed using the Langley Aerothermodynamic Upwind Relaxation Algorithm. Earth entry at 12 km/sec is examined at 70-km and 80-km altitude for two vehicle base radii of 2 m and 6 m. These four test cases bracket some proposed scenarios for earth reentry of a manned Mars mission aerobrake at this velocity. Thermochemical nonequilibrium results are examined for each case and compared with thermal equilibrium results produced by artificially accelerating vibrational relaxation rates and with equilibrium results produced by a viscous shock layer method.

Mitcheltree, R. A.↗

Uncertainty identification in mass estimation applications with imaging detectors

Mass quantification using standoff gamma imaging techniques is a boon to the special nuclear material holdup monitoring community, but before the method is deemed acceptable as a replacement for historical gamma detection-based methods, there are several considerable sources of uncertainty that must be addressed. These uncertainty sources have received sparse coverage in the literature, but provide the bulk of the uncertainty estimated in practice outside of standard counting statistics. For imaging, there is a fundamental difference between detection/localization and mass estimation operating modalities, where detection/localization can tolerate significantly larger uncertainty because the goal is detection of a distant source, rather than the quantification of that source. Historically, quantification requires a known geometry between source and detector, as well as a calibrated efficiency correction curve, which is well suited to laboratory practice for a stationary detector; however, this requires some corrections and assumptions (e.g., generalized geometry) for field applications, since additional degrees of freedom are present in the source-to-detector position, intervening materials, and non-uniform source distributions, when compared against the laboratory case. Use of an imaging detector during holdup measurements would address these issues by calculating the spatial geometry of the distant source as seen by the detector, with efficiency corrected according to the source-to-detector angle. While this aim promises a better estimation accuracy than generalized geometry assumptions, additional uncertainties are added from the imaging mechanism itself. Of these uncertainties, some are readily mitigated and methods to do so are included in the discussion, while some uncertainties are specific to the imaging class of instruments and are investigated and discussed in detail. Uncertainties are categorized into two general areas: instrument design and algorithmic. Instrument design-based uncertainties include basic detector characteristics for timing and energy resolution, handling of list mode data for coincidence detection, and geometric layout of and propagation of spatial uncertainty into imaging uncertainty. Algorithmic-based uncertainties discussed herein pertain to image reconstruction, the weight assignment problem from cone interactions, and the effects of spatial discretization on mass estimation. With these major sources of uncertainty identified, the path towards acceptance of imaging as a holdup monitoring method becomes clearer.

61 RADIATION PROTECTION AND DOSIMETRY↗