Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CO2 monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Microwave-Assisted Hydrogen Generation from Hydrocarbon-Bearing Reservoir Rocks: Stage-Dependent Thermal Runaway and In-Situ Carbonate Engineering

Microwave-assisted hydrogen generation from hydrocarbon-bearing reservoir rocks is strongly influenced by mineralogy, methane activation, carbonate reactions, and thermal runaway behavior. This study investigates a new approach in which carbonate phases are generated in-situ through the reaction of internally produced CO2 with Ca(OH)2 under microwave heating conditions. The objective is to evaluate how rock mineralogy, methane injection, and Ca(OH)2 addition influence hydrogen generation, carbon redistribution, and stage-dependent reaction pathways during microwave exposure. Microwave heating experiments were conducted using Permian Basin reservoir rocks under three experimental conditions: rock-only experiments under Ar atmosphere, CH4–Ar experiments without additive, and CH4–Ar experiments containing 5 wt% Ca(OH)2. Methane-assisted experiments were performed under continuous injection of 30 standard cubic centimeters per minute (sccm) CH4 and 30 sccm Ar. Based on thermal runaway behavior, each experiment was divided into three operational stages: Before Thermal Runaway (BR), After Thermal Runaway–Decrease in Microwave Power (ARD), and After Thermal Runaway– Increase in Microwave Power (ARI). Temperature and gas composition were continuously monitored throughout the experiments. The rock-only experiments demonstrated that hydrogen generation can occur intrinsically from hydrocarbon-bearing rocks under microwave heating, even without externally injected methane. However, hydrogen production did not correlate solely with kerogen content, indicating that mineralogy strongly influences hydrogen-generation pathways. Correlation analyses suggested that kerogen decomposition initially generated CH4, CO, and CO2, followed by secondary hydrocarbon reactions associated with H2 and C2 hydrocarbon formation. Methane-assisted experiments substantially increased hydrogen production; however, identical methane injection rates produced significantly different hydrogen yields among the rock samples, confirming that mineralogical composition controls methaneconversion behavior under microwave heating conditions. The addition of Ca(OH)2 significantly altered carbon evolution behavior in a stage-dependent manner. During the BR stage, Ca(OH)2 reduced gas-phase CO2 production, particularly in carbonate-rich rocks, indicating favorable conditions for in-situ carbonation and carbonate deposition prior to extensive thermal decomposition. The suppression of CO2 during BR became more pronounced with increasing carbonate content of the rock system. After thermal runaway, carbonate-containing systems exhibited enhanced hydrogen generation behavior, suggesting that carbonatederived mineral transformations and carbonate-mediated reactions contribute to high-temperature hydrogen-generation pathways. In carbonate-poor rocks, Ca(OH)2 addition enabled simultaneous URTeC 4493775 2 enhancement of hydrogen production and partial suppression of CO2 release during the post-runaway stages. Overall, the results demonstrate that microwave-assisted hydrogen generation is governed by dynamically evolving interactions among kerogen decomposition, methane activation, mineral transformations, carbonate formation/decomposition, and thermal runaway behavior. This work introduces in-situ carbonate engineering with Ca(OH)2 as a strategy for coupling hydrogen generation with partial insitu carbon management under microwave heating conditions.

03 NATURAL GAS↗

W.A. Parish Post-Combustion CO 2 Capture and Sequestration Demonstration Project (Final Technical Report)

The Petra Nova Project (Project) is a commercial scale post-combustion carbon capture project developed by a joint venture between NRG Energy, Inc. (NRG) and JX Nippon Oil Exploration (EOR) Limited (JX). The Project is designed to separate and capture carbon dioxide (CO2) from an existing coal-fired unit’s flue gas slipstream at NRG’s W.A. Parish Electric Generating Station (WAP) located southwest of Houston, Texas. The captured CO2 is dried, compressed, and transported via an 81-mile pipeline to the West Ranch oilfield (West Ranch) in Jackson County, Texas, where it is injected to boost oil production. The Project, which is partially funded by a grant (Grant) from the United States (U.S.) Department of Energy (DOE) under the Clean Coal Power Initiative (CCPI) Round 3, uses the Kansai Mitsubishi Carbon Dioxide Recovery advanced amine-based CO 2 absorption technology (KM-CDR Process®), which was jointly developed by Mitsubishi Heavy Industries, Ltd. (MHI) and the Kansai Electric Power Co. Inc., to treat and capture at least ninety percent (90%) of the CO 2 from a 240-megawatt equivalent (MWe) flue gas slipstream off of Unit 8 at WAP. When operating at full capacity, the Project captures approximately 5,200 short tons of CO 2 per day, which would otherwise be emitted into the atmosphere, representing the largest commercial scale deployment of post-combustion CO2 capture technology at a coal power plant to date. Under the Grant, the Project was managed in 3 phases: (1) Phase 1: Project Definition / Front End Engineering Design (FEED) (2) Phase 2: Detailed Engineering, Procurement & Construction (3) Phase 3: Demonstration and Monitoring. On December 29, 2016, commercial operation of the Project was achieved, ending Phase 2 and starting Phase 3, a 3-year demonstration period running from January 1, 2017 through December 31, 2019. The key objectives of Phase 3 were to (a) demonstrate the specific advanced technologies constructed during Phase 2 and (b) monitor the injected CO 2 at West Ranch to demonstrate technologies and protocols for monitoring, verification, and accounting (MVA). As of the end of Phase 3, Petra Nova captured 3,904,978 short tons of CO 2 (3,542,537 metric tons) that was transported to West Ranch. To support the DOE obligation to monitor, verify, and account for the sequestered CO 2 at West Ranch, Petra Nova contracted with the Bureau of Economic Geology (in the Jackson School of Geosciences at The University of Texas at Austin) to (a) design a monitoring program, (b) draft an MVA Plan for DOE review and approval, and (c) working with Petra Nova and the operator of West Ranch to manage and report on the MVA activity. This report discussed the technical aspects of the project during each of the 3 phases of the project as identified above.

01 COAL, LIGNITE, AND PEAT↗

Fe Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environment

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. Effective monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of Fe-coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscatterring reflectometer (OBR), corrosion was monitored based on the increase in backscattered intensity amplitude of the light being passed as Fe undergoes corrosion. The Fe-coated OFSs were prepared with a film thickness between 25-225 nm by an electroless plating approach and corroded by a CO2-saturated acidic electrolyte. The corrosion rate was approximately 2.5 mm/yr for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based corrosion rates were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during corrosion of Fe was established. Corrosion was measurable out to > 100 m which is a significant improvement over our previous work showing corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at >1 ft depth. Fe-coated OFS was loaded into a Draka cable which provides mechanical support during fiber deployment and installation into either acidified soil, top-soil, or sandy soil.

aqueous environment↗

Data from Unique Contributions of Chlorophyll and Nitrogen to Predict Crop Photosynthetic Capacity from Leaf Spectroscopy

The photosynthetic capacity or the CO2-saturated photosynthetic rate (Vmax), chlorophyll, and nitrogen are closely linked leaf traits that determine C4 crop photosynthesis and yield. Accurate, timely, rapid, and non-destructive approaches to predict leaf photosynthetic traits from hyperspectral reflectance are urgently needed for high-throughput crop monitoring to ensure food and bioenergy security. Therefore, this study thoroughly evaluated the state-of-the-art physically based radiative transfer models (RTMs), data-driven partial least squares regression (PLSR), and generalized PLSR (gPLSR) models to estimate leaf traits from leaf-clip hyperspectral reflectance, which was collected from maize (Zea mays L.) bioenergy plots with diverse genotypes, growth stages, treatments with nitrogen fertilizers, and ozone stresses in three growing seasons. The results show that leaf RTMs considering bidirectional effects can give accurate estimates of chlorophyll content (Pearson correlation r=0.95), while gPLSR enabled retrieval of leaf nitrogen concentration (r=0.85). Using PLSR with field measurements for training, the cross-validation indicates that Vmax can be well predicted from spectra (r=0.81). The integration of chlorophyll content (strongly related to visible spectra) and nitrogen concentration (linked to shortwave infrared signals) can provide better predictions of Vmax (r=0.71) than only using either chlorophyll or nitrogen individually. This study highlights that leaf chlorophyll content and nitrogen concentration have key and unique contributions to Vmax prediction.

Biomass Analytics↗

Mobilization of trace metals from caprock and formation rocks at the Illinois Basin – Decatur Project demonstration site under geological carbon dioxide sequestration conditions

One concern for geologic CO 2 sequestration is the potential leakage of CO 2 or CO 2 -saturated brine containing trace metals into overlying aquifers, which poses the risk of adversely affecting underground sources of drinking water. In this work, rock and brine samples collected in the Illinois Basin – Decatur Project (IBDP), a large-scale geological CO 2 sequestration demonstration project in Decatur, Illinois, USA, as well as synthetic brine samples were used to understand the mobilization of trace metals as a result of CO 2 –rock–brine interactions under IBDP-specific conditions (50 °C and 20.6 MPa). Rock sample characterization indicated that, at the IBDP site, trace metal concentrations were greatest in cap rock samples from the Eau Claire Formation, compared with those from formations above and below this Formation. The natural brine samples collected from the Mt. Simon Sandstone reservoir were highly reducing and saline, with trace metal concentrations up to 680 times greater than the U.S. Environmental Protection Agency-prescribed drinking water standards. Batch leaching experiments indicated that both trace metal mobilization from rock and immobilization from the brine occurred when high-pressure CO 2 was introduced into the rock-brine system. The amounts of metals mobilized from the rock generally accounted for <5% of the total metals in the rock, but for some metals, including Ni, Pb, and Tl, up to 63% of the metals in the rock were mobilized to the brine. Leaching of trace metals into synthetic brines was different from that into the natural brine. The results of this study provided current information on the trace element sources and will help in risk simulations and experimental design to further evaluate potential impact of leakage on groundwater quality, which is important for future GCS projects to consider for monitoring and containment assurance purposes.

58 GEOSCIENCES↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environment

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion sensor was also tested in soil at > 1 foot depth. Fe-coated OFS was loaded into a Draka cable, which provides mechanical support during fiber deployment and installation into either acidified soil, top-soil, or sandy soil (50/50).

corrosion↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

corrosion↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

aqueous environment↗

Deep learning inversion of gravity data for detection of CO 2 plumes in overlying aquifers

In this work, we developed an effective U-Net based deep learning (DL) model for inversion of surface gravity data on a rectangular grid to predict 2-D high-resolution subsurface CO 2 distribution along a vertical cross-section due to CO 2 leakage through a wellbore within a deep CO 2 storage reservoir. We used synthetic data to model two types of CO 2 leakage scenarios: one CO 2 plume in a shallow aquifer (single plume case), and two plumes present at different depths (double plume case). The 3-D synthetic plume samples were created by sampling among predetermined CO 2 plume depths, saturations, and volumes. The corresponding surface gravity data on a rectangular grid were generated by a 3-D forward model. The U-Net model detected 72% of single-plume samples, and one or both plumes in 75% of double-plume samples. Most of the undetected single plumes have small gravity field strengths below the typical noise level of 5 μGal. This model generated reproducible, reliable predictions with acceptable errors and demonstrated improved spatial resolution over the conventional least-squares inversion. In contrast to the conventional least-squares inversion, which often overestimates the size of its target and underestimates its density, this U-Net model accurately delineated the boundary of a target. Furthermore, this DL inversion detected deep, small, or low saturation CO 2 plumes that are often more difficult to resolve with conventional gravity inversion methods. We note the limitations of this feasibility study, including the use of synthetic data with regular CO 2 plume shapes, and the prediction of a 2-D plume cross-section rather than the full 3-D plume, as well, we recognize the lower detection fraction for double-plume scenarios. Nevertheless, this study demonstrates that DL gravity inversion is a promising and potentially superior method to conventional least-squares inversion. Our U-Net based deep learning inversion approach may be adapted for inversion of other types of geophysical data. DL inversion can facilitate near real-time monitoring of geologic carbon sequestration to provide site operators with prompt information about subsurface CO 2 distribution for risk management and mitigation.

58 GEOSCIENCES↗

Life Cycle Analysis of Greenhouse Gas Emissions for the Niagaran Reef Complex CO 2 -EOR Operations

The Midwest Regional Carbon Sequestration Partnership (MRCSP) was founded in 2003 as part of the U.S. Department of Energy’s (DOE’s) Regional Carbon Sequestration Partnership initiative. Since its founding, MRCSP has made significant strides toward making CCUS a viable option for states in the region. The public/private consortium, funded through the DOE Regional Carbon Sequestration Initiative, brings together nearly 40 industry partners and 10 states. Battelle, as the project lead, oversees research, development and operations and coordinates activities among the partners. The incremental, phased approach has built a valuable knowledge base for the industry and paved the way for commercial-scale adoption of CCUS technologies. From 2008 to 2020, MRCSP Phase III focused on the development of large-scale injection projects. This report is part of a series of reports prepared under the Midwestern Regional Carbon Sequestration Partnership (MRCSP) Phase III (Development Phase). These reports summarize and detail the findings of the work conducted under the Phase III project. A greenhouse gas emissions life cycle analysis (LCA) was completed for 22 years of carbon dioxide-enhanced oil recovery (CO 2 -EOR) operations at the Niagaran reef complex in the northern Michigan Basin based on research by the MRCSP. The objective of the greenhouse gas LCA was to account for the total greenhouse gas emissions generated through the CO 2 -EOR process. Methane produced from the 300 to 500 meter-deep Antrim shale has CO 2 content ranging from 5 percent to 30 percent. Therefore, the produced gas stream is gathered outside of Gaylord, Michigan, at the Chester 10 central gas processing plant, and run through an amine-based CO 2 separation process to remove the CO 2 so the methane can be sold to the market. The CO 2 is periodically dehydrated, compressed, and transported via pipeline for CO 2 -EOR in nearby 5,000- to 6,500-foot (1500-2000 m) deep carbonate Niagaran reefs. The produced mixture of oil, water, and CO 2 is separated at the Dover 36 oil processing facility. The processed CO 2 is recycled to the reefs for CO 2 -EOR in a closed loop system. During this process, a portion of the CO2 remains permanently stored in the reefs.

01 COAL, LIGNITE, AND PEAT↗

Assessing Impacts on Pressure Stabilization and Leasing Acreage for CO 2 Storage Utilizing Oil Migration Concepts

Favorable geological storage for CO 2 has long been pictured as large anticlines with thick sandstones, similar to oil reservoirs in the petroleum system. Unlike oil, however, stored CO 2 does not need to be recoverable, which raises the possibility of using dissolution and residual trapping to augment the capacity of buoyant traps and tap more of the bulk rock volume. The work presented builds on that idea, asking the following question: If we inject CO 2 down to a syncline – analogous to the carrier bed in the petroleum system – how would this injection mechanism impact storage capacity and plume shape, migration, and stabilization? To address this question, we built a reservoir model, based on seismic interpretation of Middle Miocene strata, offshore Galveston, Texas. 3-D seismic and well logs were used to characterize key intervals. Reservoirs chosen for modeling are progradational-aggradational sands with mud intercalation. They have a higher degree of heterogeneity than the more conventional reservoirs commonly targeted for CO 2 storage. Modeling investigated how far the CO 2 plume would migrate under two scenarios: (1) injecting CO 2 at the base of the salt withdrawal basin (syncline scenario) and (2) injecting CO 2 at the base of the structural closure, similar to a common injection well location for EOR purposes (base scenario). For each scenario, we separately simulated injection of 30 MT of CO 2 and 60 MT of CO 2 continuously for 30 years and observe the plume and pressure evolution for 100 years after the injection stops. The simulation shows that injecting the CO 2 into a syncline limits the vertical migration of CO 2 , thus making synclinal injection more secure. In the syncline scenario, the geological layer around the injection point is more heterogeneous than the layer in the base scenario; thus, the CO 2 tends to migrate laterally. Additionally, in the syncline scenario, the plume does not even reach the upper part of the anticline, allowing us to safely store an additional amount of CO 2 into the reservoir. Furthermore, the simulation also shows that in the syncline scenario, the times needed for the reservoir to reach its stabilized pressure after the end of injections are faster. To summarize, CO 2 injection at the base of a syncline could provide additional storage, increase the safety of the project from the limited vertical plume migration, and expedite plume stabilization, which could result in the decrease of monitoring frequency as the project runs, thus lowering the operating cost of the project in the long run.

58 GEOSCIENCES↗

Legacy Well Leakage Risk Analysis at the Farnsworth Unit Site

This paper summarizes the results of the risk analysis and characterization of the CO 2 and brine leakage potential of Farnsworth Unit (FWU) site wells. The study is part of the U.S. DOE’s National Risk Assessment Partnership (NRAP) program, which aims to quantitatively evaluate long-term environmental risks under conditions of significant geologic uncertainty and variability. To achieve this, NRAP utilizes risk assessment and computational tools specifically designed to quantify uncertainties and calculate the risk associated with geologic carbon dioxide (CO 2 ) sequestration. For this study, we have developed a workflow that utilizes physics-based reservoir simulation results as input to perform leakage calculations using NRAP Tools, specifically NRAP-IAM-CS and RROM-Gen. These tools enable us to conduct leakage risk analysis based on ECLIPSE reservoir simulation results and to characterize wellbore leakage at the Farnsworth Unit Site. We analyze the risk of leakage from both individual wells and the entire field under various wellbore integrity distribution scenarios. The results of the risk analysis for the leakage potential of FWU wells indicate that, when compared to the total amount of CO 2 injected, the highest cemented well integrity distribution scenario (FutureGen high flow rate) exhibits approximately 0.01% cumulative CO 2 leakage for a 25-year CO 2 injection duration at the end of a 50-year post-injection monitoring period. In contrast, the highest possible leakage scenario (open well) shows approximately 0.1% cumulative CO 2 leakage over the same time frame.

54 ENVIRONMENTAL SCIENCES↗

A simulation study of carbon storage with active reservoir management

As part of the Integrated Midcontinent Stacked Carbon Storage Hub (IMSCS-Hub) project led by Battelle Memorial Institute, a study was conducted to determine the feasibility of storing carbon dioxide (CO 2 ) in the stacked saline rock formations of the Sleepy Hollow Field (SHF), located in Red Willow County, southern Nebraska. A series of CO 2 injection simulation scenarios, with and without active reservoir management (ARM; brine extraction), were evaluated to investigate the feasibility of storing 50+ million tonnes (Mt) of CO 2 . The results indicated CO 2 injection combined with ARM may enable permanent storage of 50+ Mt of CO 2 . The area of review (AOR), the area in which underground sources of drinking water (USDWs) might be endangered during CO 2 injection, was assessed for the simulation scenarios. In comparison to a case without ARM, brine extraction resulted in a much smaller AOR, covering an area of 42 square miles (108.8 km 2 ), roughly one-fourth the size of an AOR resulting from CO 2 injection without ARM. Our findings, presented in this paper, indicate that CO 2 injection with ARM can improve the CO 2 storage capacity of a geologic storage complex up to 100% while also reduce the rate of pressure buildup in the subsurface, resulting in a 75% reduction in AOR. This may help in lowering carbon capture and storage project costs, risks, and effort needed to meet monitoring requirements for a storage project.

54 ENVIRONMENTAL SCIENCES↗

Application of a Geochemically Informed Leak Detection (GILD) Model to CO 2 Injection Sites on the United States Gulf Coast

The Gulf Coast region possesses great potential for CO 2 enhanced oil recovery (EOR) and CO 2 storage. A geochemically informed leak detection (GILD) model has been applied to CO 2 injection sites on the Gulf Coast with considerations of measurement variability. The Jasper aquifer in Montgomery County, Texas, was chosen to demonstrate the method. Based on background data from wells in the area, combinations of mineral and fluid compositions were used to create 23 scenarios for the geochemical model. The output from the geochemical model was used to identify sensitive monitoring species, and response functions were generated for these as a function of the CO 2 leakage concentration. The sources of measurement variability for background conditions were characterized from the Jasper aquifer background data, and then normalized using the coefficient of variation of each species across the monitoring wells. Bayesian belief network (BBN) models were constructed, and measurement variability of different levels were added to compare leak detection probabilities. Increasing measurement variability decreased the power to detect a leak of a given size. For a moderately high CO 2 concentration of 0.2 mol/kg, the probability of detecting this leakage effect using pH as the monitoring variable in an aquifer with calcite decreases from 98% (no measurement variability) to 61% (medium variability) to 33% (high variability). The loss in power of the sampling protocol with increasing measurement variability is similar in magnitude when Ca 2+ or HCO 3 - is used as the monitoring parameter, but only for aquifers with calcite.

58 GEOSCIENCES↗

SECARB 2020 Semi-Annual Field Review Reports - Anthropogenic Test

The Southern States Energy Board (SSEB) managed the overall Southeast Regional Carbon Sequestration Partnership (SECARB) Phase III project and the Electric Power Research Institute (EPRI) managed all activities associated with the Anthropogenic Test site. Advanced Resources International, Inc. (ARI) assisted EPRI with the management of site activities. EPRI and ARI followed reporting procedures that included monthly and quarterly technical progress reports, as well as periodic reporting on key field activities. Subsequent sections of this report catalog the field activities and are organized in a semi-annual chronology. The SECARB Anthropogenic Test was the largest demonstration of a fully integrated, pulverized coal-fueled carbon capture and storage (CCS) project in the United States as of 2012 and supports a commercial prototype of CO 2 capture; transportation; subsurface storage; and monitoring, verification, and accounting (MVA); and assessment. The demonstration-scale, post-combustion CO 2 capture facility at Alabama Power Company’s Plant Barry diverted flue gas (25MW equivalent) from its Unit #5 coal burning facility and captured the CO 2 using Mitsubishi Heavy Industries (MHI) KM-CDRTM advanced amine technology. The captured CO2 was compressed at Plant Barry and transported by pipeline to the injection location southeast of Citronelle, Alabama. The Citronelle Project’s geologic storage and MVA sites were located on the flanks of the Citronelle Dome, approximately three miles southeast of the city of Citronelle. The injection zone, the Paluxy Formation, a saline formation that occurs at approximately 9,400 feet and overlies the oil production horizon of the Citronelle oilfield, presents a favorable injection reservoir in terms of areal extent and petrophysical characteristics. The confining zone, the basal shale of the overlying Washita-Fredericksburg Formation, is persistent throughout the Citronelle area and possesses the appropriate criteria to act as an effective CO 2 seal.

01 COAL, LIGNITE, AND PEAT↗

North Dakota CarbonSAFE Baseline Microgravity Survey, Lessons Learned

Conference presentation at American Geophysical Union (AGU) Fall Meeting, New Orleans, LA and virtual, December 13–17, 2021. The team conducted a baseline microgravity survey near Minnkota Power Cooperative’s Milton R. Young power station, south of Center, North Dakota, as a part of the North Dakota CarbonSAFE (Carbon Storage Assurance Facility Enterprise) geophysical activities. The goal of this survey was to assess whether microgravity would be an appropriate technique to monitor CO 2 stored at this site.

20 FOSSIL-FUELED POWER PLANTS↗

Machine Learning Applications in Analyzing the Role of Shale Barriers and Baffles for CO2 Storage

This study uses machine learning to analyze microseismic data from the Illinois Basin Decatur Project (IBDP) and quantify CO₂ plume extents. By leveraging well logs, microseismic records, and CO₂ injection metrics, the research predicts subsurface CO₂ plume dynamics. Findings show vertical clustering of microseismic events near the injection well, with CO₂ periodically breaching barriers due to buoyancy. K-Means clustering performed best, achieving the highest Silhouette Score and lowest Davies-Bouldin Index. This capability is crucial for real-time monitoring and management of CO₂ sequestration sites, validated against physical models and IBDP data, reinforcing CO₂ geological sequestration's viability and enhancing management tools.

Carr, Timothy↗

2D Seismic Surveys as an Alternative for CO 2 Monitoring in the North Dakota CarbonSAFE Project

Conference presentation for International Meeting for Applied Geoscience & Energy (IMAGE), Houston, TX, August 28 – September 1, 2023. As part of the North Dakota CarbonSAFE project, seismic, controlled-source electromagnetic, and microgravity baseline monitoring surveys were collected to assess the safe, permanent, commercial-scale geologic storage of CO 2 generated by the Milton R. Young coal-fired power plant. Data from five 2D seismic lines were assessed as an alternative to 3D seismic for CO 2 monitoring. 2D and 3D surveys were compared using wave equation-based (WEB)-AVO inversion. The encouraging WEB-AVO results demonstrated that 2D surveys could be included in CO 2 monitoring programs as a cost-effective method.

20 FOSSIL-FUELED POWER PLANTS↗