Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CLEARANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

High Temperature Investigations into an Active Turbine Blade Tip Clearance Control Concept

System studies have shown the benefits of reducing blade tip clearances in modern turbine engines. Minimizing blade tip clearances throughout the engine will contribute materially to meeting NASA s Ultra-Efficient Engine Technology (UEET) turbine engine project goals. NASA GRC is examining two candidate approaches including rub-avoidance and regeneration which are explained in subsequent slides.

Taylor, Shawn C.↗

Human-in-the-Loop Assessment of Alternative Clearances in Interval Management Arrival Operations

Interval Management Alternative Clearances (IMAC) was a human-in-the-loop simulation experiment conducted to explore the Air Traffic Management (ATM) Technology Demonstration (ATD-1) Concept of Operations (ConOps), which combines advanced arrival scheduling, controller decision support tools, and aircraft avionics to enable multiple time deconflicted, efficient arrival streams into a high-density terminal airspace. Interval Management (IM) is designed to support the ATD-1 concept by having an "Ownship" (IM-capable) aircraft achieve or maintain a specific time or distance behind a "Target" (preceding) aircraft. The IM software uses IM clearance information and the Ownship data (route of flight, current location, and wind) entered by the flight crew, and the Target aircraft's Automatic Dependent Surveillance-Broadcast state data, to calculate the airspeed necessary for the IM-equipped aircraft to achieve or maintain the assigned spacing goal.

Baxley, Brian T.↗

Dynamics and Clearance Analysis of NASA's Space Launch System Block-1 and Block 1B Solid Rocket Booster Separation Event

NASA’s Space Launch System (SLS) solid rocket booster separation event is an essential area of study requiring high fidelity modelling to capture the complexity of an intra-atmospheric stage separation event. The setup and analysis for this event leveraged the NASA-developed CLVTOPS multi-body dynamics toolchain to model aerodynamics at the separation event, booster thrust tailoff, and Core Stage engine throttling in addition to the separation system itself (booster separation motors (BSMs), pyrotechnic bolts and struts). The approach documented here will give a brief background on the CLVTOPS toolchain, how key input models are integrated and verified, and how results are quantified using an ordered-statistics approach. Specific areas discussed herein address the performance-to-orbit realized by adjusting the delay time between the separation cue and the actual separation event, and how the orientation of the aft BSMs was tuned to address small clearances between the aft diagonal attach struts and the Core Stage. Post-flight results from the inaugural Artemis I flight are also shown, and validation is performed between predicted vs. actual separation dynamics and clearances. Challenging night launch conditions necessitated comparisons that were more qualitative in nature, but still showed very good agreement to pre-flight predictions.

Carole J Addona↗

Clearance Measurements prior to the Shut-Down of ERAM

Low and intermediate level radioactive waste was emplaced in the Morsleben Repository (ERAM), a former salt mine, until 1998. Now the German Federal Office for Radiation Protection (Bundesamt fuer Strahlenschutz - BfS) has applied for the decommissioning of the plant. The ERAM's own radioactive waste requires clearance as far as it may not remain in the repository. The German Mining Law also demands all non-mining typical waste to be removed from the mine when being decommissioned and the Waste Avoidance, Recovery and Disposal Act demands waste to remain within the economy cycle if this is economically justifiable. Therefore new clearance measuring devices have to be applied using gamma and beta radiation to determine the contamination of objects and substances regarding the special nuclide spectra in the ERAM. Even if a very multifaceted radionuclide spectrum is to be expected due to the fact that the emplaced waste results from various applications such as nuclear engineering, medicine, research, and military, numerous investigations have confirmed that only a few radionuclides have to be considered. To facilitate this procedure the controlled area of the ERAM is to be classified according to different contamination categories. Assumptions about the radionuclide mixture are permanently controlled by routine measurements and the evaluation of possible contamination events. The considerations about the radionuclide mixture and the structure of the controlled area will be described in this presentation. Furthermore a new methodology to measure Sr-90 is discussed which uses the Cerenkov effect and the low level of background gamma radiation in the salt mine. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a New Clearance Monitor for Exemption of NPP Radioactive Wastes and its Performance Test - 17200

In nuclear power plants, it is common practice to clear radioactive wastes for free release by using clearance monitor with plastic scintillation detectors so as to reduce disposal costs. These monitors are possible in part thanks to the excellent detection levels achievable with high energy and high yield photons emitted from contaminants such as Cs-137 and Co-60. However, it is difficult for the monitors to separate Naturally Occurring Radioactive Materials (NORM) from the radioactive wastes because the plastic scintillation detectors have poor resolution compared to NaI or HPGe detectors. KHNP has developed a new clearance monitor for determining whether or not the radioactivity level of metal scraps satisfies regulatory criteria. The monitor is composed of 12 large area plastic scintillation detectors and 3 NaI scintillation detectors. The measuring chamber is surrounded by a 5 cm-thick lead shield with chamber dimensions of 1.5 m x 1.0 m x 1.0 m. Its algorithm has a function of measuring total gamma activity while analyzing gamma nuclides and identifying 27 hotspots in radioactive wastes. The detection limit of this system, according to the MCNP simulation, was determined to be about 45 Bq for Co-60 and 78 Bq for Cs-137 with the condition of an empty chamber and measuring time of 1 minute. We evaluated the self - shielding effect of waste for background correction factor and waste height (volume in the chamber) correction factor. We also tested its MDA, location determination of hot-spots, temperature compensation function and convenience of operation. In the future, we will plan to install it at a nuclear site for more tests including evaluating its durability. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Innovative Universal Separation Process (USEP) for Disposal of Mixed Liquid Waste Via Unconditional Clearance Approach - 17570

Historically, Mixed Liquid Waste (MLW) drums from Canadian nuclear facilities containing Tritium (H-3) and other radionuclides (alpha as well as beta/gamma emitting) were shipped to a licensed US facility for destruction via incineration. This option is relatively complex considering the logistics associated with cross-border shipments and the destruction costs (e.g. H-3 surcharge). Because of this, Kinectrics has developed a novel and flexible process for disposal of oily as well as other (solvents, aqueous etc.) MLW within Canada. This process avoids the need for cross-border shipments and significantly reduces the complexity as well as cost for waste disposal. An overview of the various approaches and activities undertaken by Kinectrics during the period 2009-2013 for successfully processing and disposing of several MLW drums (oils, solvents, aqueous and solids) was reported at the WM-2013 conference. One of the key approaches for management of both oily Polychlorinated Biphenyls (PCB) as well as non-PCB MLW involves treatment of the mixed waste using various well-known unit operations such as filtration, treatment with commercial sorbents, and various proprietary treatment methods developed at Kinectrics. These approaches result in reduction of radionuclide activity levels to below the unconditional clearance criteria and allows disposal of the waste via incineration at a conventional chemical waste facility. A small amount of radioactive secondary waste (the captured radionuclides) is returned to the customer. This approach was successfully employed for processing several drums of PCB and non-PCB MLW. Kinectrics recently completed two projects involving processing for disposal of legacy oily and solvent MLW inventory for a Canadian nuclear customer. Waste treatment processes used previously for unconditional clearance of oily/solvent MLW were ineffective for treatment of these legacy waste drums. Some drums were particularly challenging to process since H-3 was chemically associated with the oil backbone. To address these challenges, Kinectrics developed the innovative Universal Separation (USEP) process for disposal of problematic MLW. This paper presents an overview of the USEP process, the latest results of drum scale (205 L) process demonstration work, and the design concept of a Mobile Processing Unit (MPU) for large scale batch (1500 L) processing of MLW employing the USEP process. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Decontamination of Radio-Cs in Soil and Incineration Fly Ash to the Clearance Level by Pyrolysis - 18247

Radio-Cs generated by the Fukushima Daiichi Nuclear Power Plant accident is decontaminated from contaminated soil and incineration fly ash to the clearance level via pyrolysis treatment. By adjusting the chemical composition of soil and ash to be in line with ordinary Portland cement, OPC and adding a small amount of CaCl{sub 2}, radio- and stable Cs can evaporate almost completely and be collected by a bag filter system after cooling in the form of chlorides as a component of potassium chloride. Laboratory-scale experiments have produced cement with a radio-Cs content of less than the detection limit from several grams of pond sediments having an initial radio-Cs content of 9293 Bq/kg via burning at over 1275 deg. C using a small-scale rotating furnace. It is also possible to decontaminate radio-Cs from incineration fly ash using the same system. OPC complying with the clearance level for radio-Cs is produced as a product of this system and the basic components are confirmed via X-ray diffraction and Rietveld analysis. In order to obtain a suitable cement mineral composition, a burning temperature of 1400 or 1450 deg. C is required. Using a pilot-scale kiln, 100 kg of OPC is produced from imitated soil with the addition of Cs{sub 2}CO{sub 3}, calcined, and then burned at 1450 deg. C. The produced cement cleared the required basic performances specified by Japanese industrial standards. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimated Chemical Warfare Agent Surface Clearance Goals for Remediation Pre-Planning

Health-based surface clearance goals, in units of mg/cm2, have been developed for the persistent chemical warfare agents sulfur mustard (HD) and nerve agent VX as well as their principal degradation products. Selection of model parameters and critical receptor (toddler child) allow calculation of surface residue estimates protective for the toddler child, the general population and adult employees of a facilty that has undergone chemical warfare agent attack.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Continuum-kinetic-microscopic model of lung clearance due to core-annular fluid entrainment

The human lung is protected against aspirated infectious and toxic agents by a thin liquid layer lining the interior of the airways. This airway surface liquid is a bilayer composed of a viscoelastic mucus layer supported by a fluid film known as the periciliary liquid. The viscoelastic behavior of the mucus layer is principally due to long-chain polymers known as mucins. The airway surface liquid is cleared from the lung by ciliary transport, surface tension gradients, and airflow shear forces. This work presents a multiscale model of the effect of airflow shear forces, as exerted by tidal breathing and cough, upon clearance. The composition of the mucus layer is complex and variable in time. To avoid the restrictions imposed by adopting a viscoelastic flow model of limited validity, a multiscale computational model is introduced in which the continuum-level properties of the airway surface liquid are determined by microscopic simulation of long-chain polymers. A bridge between microscopic and continuum levels is constructed through a kinetic-level probability density function describing polymer chain configurations. The overall multiscale framework is especially suited to biological problems due to the flexibility afforded in specifying microscopic constituents, and examining the effects of various constituents upon overall mucus transport at the continuum scale.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scavenger receptor MARCO contributes to macrophage phagocytosis and clearance of tumor cells

Highlights: • The MARCO receptor on macrophages was positively correlated with the ability to phagocyte tumor cells. • Macrophage MARCO affects cytoskeleton rearrangement and pseudopodia formation through the SYK-PI3K-Rac1 pathway. • Integrin is the ligand of MARCO on the tumor cells. Macrophage receptor with collagenous structure (MARCO) is a member of the class A scavenger receptor family which is expressed on the cell surface of macrophages. It is well known that MARCO avidly binds to unopsonized pathogens, leading to its ingestion by macrophages. However, the role of MARCO in the recognition and phagocytosis of tumor cells by macrophages remains poorly understood. In this study, we used lentiviral technology to knockdown and overexpress MARCO and investigated the ability of macrophages to phagocytose tumor cells. Our results showed that MARCO expression was correlated with the ability of macrophages to carry on phagocytosis. MARCO knockdown led to significant decreases in the number of engulfment pseudopodia of macrophages and inhibition of the phagocytosis of tumor cells. On the other hand, MARCO overexpression elevated activity of SYK, PI3K and Rac1 in macrophages, which led to changes in macrophage morphology and enhanced phagocytosis by promoting formation of stress fibers and pseudopodia. By Co-IP analysis we showed that MARCO directly binds to the β5 integrin of SL4 tumor cells. In summary, these results demonstrated the important role for MARCO in demonstrated tumor cells uptake and clearance by macrophages.

60 APPLIED LIFE SCIENCES↗

Potential dose distributions at proposed surface radioactvity clearance levels resulting from occupational scenarios.

The purpose of this report is to evaluate the potential dose distribution resulting from surface radioactivity, using occupational radiation exposure scenarios. The surface radioactivity clearance values considered in this analysis may ultimately replace those currently specified in the U.S. Department of Energy (DOE) requirements and guidance for radiological protection of workers, the public and the environment. The surface contamination values apply to radioactive contamination deposited on a surface (i.e., not incorporated into the interior of the material). For these calculations, the dose coefficients for intake of radionuclides were taken from ICRP Publication 68 (ICRP 1994), and external exposure dose coefficients were taken from the compact disc (CD) that accompanied Federal Guidance Report (FGR) 13 (Eckerman et al. 1999). The ICRP Publication 68 dose coefficients were based on ICRP Publication 60 (ICRP 1990) and were used specifically for worker dose calculations. The calculated dose in this analysis is the 'effective dose' (ED), rather than the 'effective dose equivalent' (EDE).

07 ISOTOPE AND RADIATION SOURCES↗

Applicability of the “Gallet equation” to the vegetation clearances of NERC Reliability Standard FAC-003-2

NERC has proposed a standard to use to specify clearances between vegetation and power lines. The purpose of the rule is to reduce the probability of flashover to a calculably low level. This report was commissioned by FERC’s Office of Electrical Reliability. The scope of the study was analysis of the mathematics and documentation of the technical justification behind the application of the Gallet equation and the assumptions used in the technical reference paper.

clearances↗

A Methodology for Measuring Blade Clearance on an Operating Utility-Scale Wind Turbine

This report describes the deployment of eleven laser sensors to measure the clearance between blades and tower in a 1.5-MW wind turbine whose rotor was mounted first in upwind and then in downwind configurations. The experimental recordings are compared to the numerical predictions generated by an aeroservoelastic model of the turbine. Good agreement is found between the two datasets, although discrepancies up to 30~cm are observed. The sources of this error are discussed. This methodology is found to be a valuable resource for the validation of the numerical predictions of the flapwise deflections of wind turbine blades. The accurate prediction of these deflections is increasingly important as wind turbines grow in size and become increasingly flexible.

17 WIND ENERGY↗

Statistical Tolerance and Clearance Analysis for Assembly

Tolerance is inevitable because manufacturing exactly equal parts is known to be impossible. Furthermore, the specification of tolerances is an integral part of product design since tolerances directly affect the assemblability, functionality, manufacturability, and cost effectiveness of a product. In this paper, we present statistical tolerance and clearance analysis for the assembly. Our proposed work is expected to make the following contributions: (i) to help the designers to evaluate products for assemblability, (ii) to provide a new perspective to tolerance problems, and (iii) to provide a tolerance analysis tool which can be incorporated into a CAD or solid modeling system.

statistical tolerance clearance analysis Monte-Car↗

A 'Method Based Survey' Succeeds in a Spanish Scrap Clearance Project - 15664

During the last years, a Waste Minimization Project has been implemented in Cofrentes NPP in a collaborative effort performed by IBERDROLA and ENRESA. The final result has been more than 760 t of metallic scrap including containerised materials but also massive surface contaminated objects have been managed and finally cleared. The initial project scope included 10 spent fuel pool racks weighting 130 tones but limited testing demonstrated they presented high contamination levels and were managed as radwaste including down-sizing and conditioning in ENRESA standard radwaste containers for metallic scrap (CMT's). This project started in 2008 and finished just in the summer of 2014. During these years planning and licensing, procurement, execution, including, a huge effort in decontamination and clearance measurement, was developed. The project closure is developing actually. The residual materials were stored and initially characterized previously its down-sizing and decontamination using chemical baths (warm diluted sulfuric acid and ultrasounds) , blasting (water jetting with iron grit) and in special cases mopping using industrial cleaners). Some big items were decontaminated previously its down-sizing. The materials were cleared using an approach similar to MARSAME approach based in MARSSIM guidelines. The 160 containers needed six in situ gamma spectrometry measurements each and 115 massive (from 0.45 t to 13.7 t) items need at least so many measurements as total surface in square meters. In total 763 t were cleared with only 0.6 t rejected and treated as radwaste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PGC-1{alpha} accelerates cytosolic Ca{sup 2+} clearance without disturbing Ca{sup 2+} homeostasis in cardiac myocytes

Energy metabolism and Ca{sup 2+} handling serve critical roles in cardiac physiology and pathophysiology. Peroxisome proliferator-activated receptor gamma coactivator 1 alpha (PGC-1{alpha}) is a multi-functional coactivator that is involved in the regulation of cardiac mitochondrial functional capacity and cellular energy metabolism. However, the regulation of PGC-1{alpha} in cardiac Ca{sup 2+} signaling has not been fully elucidated. To address this issue, we combined confocal line-scan imaging with off-line imaging processing to characterize calcium signaling in cultured adult rat ventricular myocytes expressing PGC-1{alpha} via adenoviral transduction. Our data shows that overexpressing PGC-1{alpha} improved myocyte contractility without increasing the amplitude of Ca{sup 2+} transients, suggesting that myofilament sensitivity to Ca{sup 2+} increased. Interestingly, the decay kinetics of global Ca{sup 2+} transients and Ca{sup 2+} waves accelerated in PGC-1{alpha}-expressing cells, but the decay rate of caffeine-elicited Ca{sup 2+} transients showed no significant change. This suggests that sarcoplasmic reticulum (SR) Ca{sup 2+}-ATPase (SERCA2a), but not Na{sup +}/Ca{sup 2+} exchange (NCX) contribute to PGC-1{alpha}-induced cytosolic Ca{sup 2+} clearance. Furthermore, PGC-1{alpha} induced the expression of SERCA2a in cultured cardiac myocytes. Importantly, overexpressing PGC-1{alpha} did not disturb cardiac Ca{sup 2+} homeostasis, because SR Ca{sup 2+} load and the propensity for Ca{sup 2+} waves remained unchanged. These data suggest that PGC-1{alpha} can ameliorate cardiac Ca{sup 2+} cycling and improve cardiac work output in response to physiological stress. Unraveling the PGC-1{alpha}-calcium handing pathway sheds new light on the role of PGC-1{alpha} in the therapy of cardiac diseases.

60 APPLIED LIFE SCIENCES↗

Efficient internalization of mesoporous silica particles of different sizes by primary human macrophages without impairment of macrophage clearance of apoptotic or antibody-opsonized target cells

Macrophage recognition and ingestion of apoptotic cell corpses, a process referred to as programmed cell clearance, is of considerable importance for the maintenance of tissue homeostasis and in the resolution of inflammation. Moreover, macrophages are the first line of defense against microorganisms and other foreign materials including particles. However, there is sparse information on the mode of uptake of engineered nanomaterials by primary macrophages. In this study, mesoporous silica particles with cubic pore geometries and covalently fluorescein-grafted particles were synthesized through a novel route, and their interactions with primary human monocyte-derived macrophages were assessed. Efficient and active internalization of mesoporous silica particles of different sizes was observed by transmission electron microscopic and flow cytometric analysis and studies using pharmacological inhibitors suggested that uptake occurred through a process of endocytosis. Moreover, uptake of silica particles was independent of serum factors. The silica particles with very high surface areas due to their porous structure did not impair cell viability or function of macrophages, including the ingestion of different classes of apoptotic or opsonized target cells. The current findings are relevant to the development of mesoporous materials for drug delivery and other biomedical applications.

60 APPLIED LIFE SCIENCES↗

Dewetting transition assisted clearance of (NFGAILS) amyloid fibrils from cell membranes by graphene

Clearance of partially ordered oligomers and monomers deposited on cell membrane surfaces is believed to be an effective route to alleviate many potential protein conformational diseases (PCDs). With large-scale all-atom molecular dynamics simulations, here we show that graphene nanosheets can easily and quickly win a competitive adsorption of human islet amyloid polypeptides (hIAPP{sub 22-28}) NFGAILS and associated fibrils against cell membrane, due to graphene's unique two-dimensional, highly hydrophobic surface with its all-sp{sup 2} hybrid structure. A nanoscale dewetting transition was observed at the interfacial region between the fibril (originally deposited on the membrane) and the graphene nanosheet, which significantly assisted the adsorption of fibrils onto graphene from the membrane. The π–π stacking interaction between Phe23 and graphene played a crucial role, providing the driving force for the adsorption at the graphene surface. This study renders new insight towards the importance of water during the interactions between amyloid peptides, the phospholipidic membrane, and graphene, which might shed some light on future developments of graphene-based nanomedicine for preventing/curing PCDs like type II diabetes mellitus.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗