Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Utilizing Gaps and Key Performance Parameters to Inform NASA Environmental Control and Life Support and Human Health and Performance Capability Technology Decisions

Human spaceflight is a complex endeavor requiring multiple capabilities for transportation, crew health, scientific goals, and safe return to Earth. The difference between spaceflight proven capabilities and those needed for future exploration architectures is defined as a capability gap. Capability gaps are not technology specific. Each capability gap is approachable with a wide array of technologies that have unique benefits and challenges. Determining what a capability’s relevant and distinguishing key performance parameters (KPPs) are for a mission is critical. Mass, power, and volume are always constrained and important, but defining these in a way normalized by performance is challenging. Additionally, KPP definition for reliability, dormancy, and integration needs are very important and still evolving. This paper provides the approach of the Environmental Control and Life Support – Crew Health and Performance (ECLSS-CHP) System Capability Leadership Team (SCLT) has used to define gaps and KPPs in support of the NASA’s Capabilities Integration Team data call objectives. The nine ECLSS-CHP capability areas are decomposed to capabilities with ~76 gaps and supported with KPPs. Rather than defining very detailed gaps, ECLSS-CHP defines high-level gaps to be technology agnostic. Within a gap, detailed KPPs are defined to both compare technologies and measure progress within a technology over time. Ideally, KPPs are clearly defined, widely communicated both internally and externally, and provide a common nomenclature to describe the state of the art and the degree of improvement required for exploration missions. KPPs help define when the gap is closed, and the core mission objectives can be accomplished. Further technology improvements to enhance the capability, as measured by improved KPPs, must then be weighed against investments in open capability gaps that prevent NASA from achieving its exploration missions. It is uncommon that a technology maturation to improve all the relevant KPPs simultaneously but using KPPs is a critical technology investment decision making component. In addition to traditional technology selections, KPPs are informing how investments in ground testing prior to and in parallel with ISS technology demonstrations are required to improve reliability KPPs. The collection of all major technology activities within a capability area are captured on technology roadmaps to communicate how diverse program activities are coordinated to close gaps and infuse into exploration mission needs. A selection of ECLSS-CHP gaps and KPPs and their formulation, current state, and how they inform capability roadmap planning are discussed.

Life Support↗

The Exploration Crew Health and Performance System of the Future - A Shared Mental Model

The challenges involved in vehicle/habitat design and operation for long-duration deep space missions are complex, and the needs of a human crew must be considered in the context of all the system trades required to enable such missions. An exploration Crew Health and Performance (CHP) system complements all the other vehicle/habitat systems to achieve one specific and critical endpoint – ensuring that the astronauts can perform the job that they were sent into space to do. This includes accounting for all aspects of the physiological, psychological, medical, and environmental realities that the human crew must face in deep space. Along with this system complexity comes the additional need for increased autonomy of the crew due to the immense distance from Earth. The design of future systems must respect the real human capabilities and limitations within the context of a mission to the Moon or Mars. The NASA Moon to Mars Objectives document outlines the need for advanced CHP system designs: • Develop systems that monitor and maintain crew health and performance throughout all mission phases, including during communication delays to Earth, and in an environment that does not allow emergency evacuation or terrestrial medical assistance. • Evaluate and validate progressively Earth-independent crew health & performance systems and operations with mission durations representative of Mars-class missions. • Validate readiness of systems and operations to support crew health and performance for the initial human Mars exploration campaign. This presentation will outline the initial work that Exploration Medical Capability is leading on the development of a prototype design for an exploration Crew Health and Performance (CHP) system for future NASA human deep space long-duration missions. This effort will require commitment from all stakeholders to a shared mental model of what a future exploration CHP system should look like, one that will address the needs, goals, and objectives of the Agency and help to ensure mission success in deep space.

K R Lehnhardt↗

Strategies for Quantifying Human Space Flight Performance in the Crew Health and Performance System

The Crew Health and Performance-Probabilistic Risk Assessment (CHP-PRA) team at NASA Glenn Research Center is planning a customized approach to quantify human spaceflight performance changes with respect to changes to the CHP system functions and capabilities. Using the Directed Acyclic Graphs (DAG) initiated by NASA’s Human Systems Risk Board (HSRB) [1], the team is surveying potential candidate models and novel strategies that generate metrics suitable for supporting decision making related to how the CHP system may influence human system performance risk. One such investigation includes classic Human Reliability Analysis (HRA) models. Traditionally, HRA methods estimate the occurrence of human errors and their impact on the success of an activity when designing and operating a system. While humans perceive, interpret, decide on, and carry out a course of action, the factors affecting performance and error likelihood are commonly referred to as performance shaping factors (PSFs). Originally developed to alleviate safety concerns related to nuclear power plant operations, HRA methods such as THERP [2] and CREAM [3] dismantle an activity into tasks, requiring elemental steps to be executed, and assess their failure due to predefined PSFs. In this study, we compare generic HRA methods and those that incorporate some human spaceflight aspects, such as sleep conditions (SCREAM [4]), with respect to how they may be adopted to capture performance with an intention to mitigate detrimental outcomes elucidated by the HSRB DAGs. We suggest strategies to quantify astronaut performance specific to spaceflight activities and illustrate how such concepts may help in optimizing the CHP system capabilities with respect to Artemis missions.

dag↗

Crew Health and Performance Integrated Data System Platform Project Updates

Future human exploration missions introduce a new paradigm as crews move further from the resupply and near real-time ground support typical of Low Earth Orbit missions today. Without immediate support from ground-based personnel, exploration crews will be more reliant on inflight data and technology to respond to emergencies and anomalies. Today, in-flight data is often siloed, unsynchronized, and largely inaccessible in real time. Many data sets require manual entry and/or data transfer between vehicles and the ground. These issues contribute to risks in supporting crew autonomy for future exploration missions. An integrated data system platform is needed to mitigate these risks by supporting a new generation of technologies and employing advanced analytical and predictive modeling techniques to enable crew autonomy for future exploration missions. The Crew Health and Performance Integrated Data System Platform (CHP-IDSP) project is laying a foundation for future in-flight informatics by providing a back-end architecture for collecting, storing, and integrating multiple sources of data generated by and around the crew. This cohesive integration point will streamline the management of CHP data (e.g., environmental, exercise, medical, sleep, performance, etc.) and facilitate situation awareness and decision support required by the crew and remote support of exploration missions. This presentation will describe the ongoing development effort of the path-to-flight CHP-IDSP software and the demonstration of its core capabilities. This includes a brief history of the project, the human-centered process used to identify data needs and workflows feeding the development of scenarios and requirements, and current subsystem development status. Current integrations, including the Chiron exploration electronic health record application, will be discussed. Future work includes collaboration with additional CHP domains and a flight technology demonstration.

Data integration↗

Onsite Energy Techno-Economic Analysis Using REopt

Since 2019, the National Renewable Energy Laboratory (NREL) has collaborated with IEDO's Combined Heat and Power (CHP) Deployment Program and the CHP Technical Assistance Partnerships (TAPs) to expand the capabilities of NREL's publicly available REopt® tool for techno-economic analysis of on-site energy. As a result, capabilities to analyze heating and cooling loads and serve those loads with CHP were added to the REopt tool in 2021. Currently, NREL is using REopt to evaluate the economics and feasibility of deploying distributed energy resources at sites of 3-5 manufacturers. The analysis is based on location, site-specific load data, customized utility bill analysis, and other criteria such as resilience needs and decarbonization targets. The objectives of the current effort are to (1) assist manufacturers with analyzing on-site energy options, including CHP, solar photovoltaics (PV), wind, and battery storage, (2) validate the capabilities and use of REopt to provide technical assistance to manufacturers, and (3) publish case studies showcasing the engagement, key takeaways, and lessons learned. Future work is expected to include additional REopt capabilities for evaluating other technologies to reduce scope 1 emissions, such as electrifying process heating loads, using carbon-free fuels, and other clean heat strategies.

ENERGY PLANNING, POLICY, AND ECONOMY↗

The Added Economic and Environmental Value of Solar Thermal Systems in Microgrids with CombinedHeat and Power

The addition of solar thermal and heat storage systems can improve the economic, as well as environmental attraction of micro-generation systems, e.g. fuel cells with or without combined heat and power (CHP) and contribute to enhanced CO2 reduction. However, the interactions between solar thermal collection and storage systems and CHP systems can be complex, depending on the tariff structure, load profile, etc. In order to examine the impact of solar thermal and heat storage on CO2 emissions and annual energy costs, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program. The objective is minimization of annual energy costs. This paper focuses on analysis of the optimal interaction of solar thermal systems, which can be used for domestic hot water, space heating and/or cooling, and micro-CHP systems in the California service territory of San Diego Gas and Electric (SDG&E). Contrary to typical expectations, our results indicate that despite the high solar radiation in southern California, fossil based CHP units are dominant, even with forecast 2020 technology and costs. A CO2 pricing scheme would be needed to incent installation of combined solar thermal absorption chiller systems, and no heat storage systems are adopted. This research also shows that photovoltaic (PV) arrays are favored by CO2 pricing more than solar thermal adoption.

03 NATURAL GAS↗

Integration of renewable energy generation and storage systems for emissions reduction in an islanded campus microgrid

Microgrid connected building communities are projected to play an integral part in the clean energy transition. These types of systems, when integrated with distributed energy resources (DERs) such as combined heat and power (CHP), district heating and cooling, renewable generation, and energy storage, can provide clean, reliable power to critical facilities and vulnerable communities. The intermittent nature of renewable generation is a challenge when integrating renewables into any grid system, but particularly in islanded microgrids. The University of Texas at Austin (UT) operates an islanded microgrid powered by a CHP plant, while also utilizing district heating and cooling systems and thermal energy storage (TES). High fidelity operating data was used to develop a validated reduced order model of UT’s integrated campus energy systems to serve as a testbed for use in a case study. Hypothetical renewable energy installations on land owned by UT in west Texas were modeled and integrated into the validated campus models along with battery energy storage (BES). Simulations showed that a combination of renewable energy from wind, and optimally controlled 24-hour thermal and battery storage systems could reduce carbon dioxide emissions on campus by 45.4%. The additional retrofit of burner systems to utilize hydrogen natural gas blends resulted in an overall annual emissions reduction of 54.7%. Carbon capture and storage eliminated the majority of the remaining emissions with increased plant energy expenditure. The presented simulations display the practical limitations of a CHP system complemented by renewable generation and short-term storage in eliminating emissions. Furthermore, results highlight the need for further research and development in long duration storage technologies and hydrogen fueled turbines to increase penetration of renewable energy and reduce emissions.

CHP↗

Harmonics and Stability Evaluation of Converter-Interfaced Combined Heat and Power Units

Grid integration of medium-sized combined heat and power (CHP) units is challenging due to strict grid codes and conventional generators lack of control flexibility to meet these grid codes. Adding a two-stage ac-dc-ac power electronics interface between the generator and the utility grid will accelerate the interconnection process of CHP units. For the dc-ac stage, a voltage source converter (VSC) has been widely used as a grid-tied inverter because of its fast control and low total harmonics distortion (THD). In this paper, several topologies of generator-side rectifiers for ac-dc power conversion are explored and analyzed. The harmonics impact of various rectifiers on the CHP generator are evaluated. The overall cost of the electrical system, when using various types of rectifiers, is assessed and the VSC back-to-back converter interface configuration is found to be optimal. The overall system stability is also examined using small-signal impedance analysis to assess potential instability issues at the system level.

CHP, Harmonics, Generator Rectifier Unit, DC Imped↗

Deployment of FlexCHP System

The Gas Technology Institute (GTI), along with its partner Integrated CHP Systems Corporation, has developed and demonstrated an Ultra-Low-Nitrogen Oxide (ULN) Flexible Combined Heat and Power (FlexCHP) system that packages a state-of-the-art Capstone C65 gas microturbine and Johnston PFXX100 boiler with an innovative natural gas-fired supplemental burner. Supplemental burners add heat as needed in response to facility demand, which increases energy efficiency, but typically raises exhaust NOx levels, degrading local air quality unless a costly and complicated catalytic treatment system is added. The FlexCHP system increases energy efficiency and achieves the 2007 California Air Resource Board (CARB) distributed generation emissions standards for Nitrogen oxides (NOx), Carbon Monoxide (CO), and Total Hydrocarbons (THC) without catalytic exhaust gas treatment. The key to this breakthrough performance is a simple and reliable burner design which utilizes staged combustion with engineered internal recirculation. This ULN burner system successfully uses turbine exhaust as an oxidizer, while achieving high efficiencies and low emissions. In tests at its laboratory facilities in Des Plaines, Illinois, GTI validated the ability of the system to achieve emissions of NOx, CO, and THC below the CARB criteria of 0.07, 0.10, and 0.02 lb/MW-h respectively. The FlexCHP system was installed at the field demonstration site, Inland Empire Foods, in Riverside, California to verify performance of the technology in an applied environment. The resulting Combined Heat and Power (CHP) package promises to make CHP implementation more attractive, mitigate greenhouse gas emissions, and improve the reliability of electricity supply.

30 DIRECT ENERGY CONVERSION↗

Combined Heat and Power in Resilience Planning and Policy

This issue brief highlights CHP’s current use in critical infrastructure applications, operational aspects of using CHP to enhance resilience, tools and resources for policymakers, and example approaches for incorporating CHP in resilience planning and policies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Renewable Combined Heat and Power for Ethanol

Conference presentation at 48th International Technical Conference on Clean Energy (Clearwater Clean Energy Conference), Clearwater, Florida, June 16–19, 2024. This project evaluates the technical and economic feasibility of small‑scale combined heat and power (CHP) systems using corn stover to support bioenergy with carbon capture and storage (BECCS) at ethanol facilities. The work includes resource characterization, pilot‑scale gasification and CO 2 capture testing to support techno‑economic analysis, economic evaluation of CHP deployment and potential carbon revenue, and life‑cycle assessment of gasification‑based CHP systems.

09 BIOMASS FUELS↗

Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

According to the U.S. Department of Energy Combined Heat and Power Installation Database, approximately 80 GW of electrical power is produced in the United States using combined heat and power (CHP) systems. Studies have also shown that a potential market for CHP applications is larger than the existing market. Since fuel consumption is the most significant part of the operating cost for a CHP plant, higher efficiency translates to increased power output for the same quantity of fuel.

CHHP, LHV, CHP↗

Combined Heat and Power Deployment Program

Combined heat and power (CHP) is an efficient and clean approach to generating on-site electric power and useful thermal energy from a single fuel source. Instead of purchasing electricity from the distribution grid and burning fuel in an on-site furnace or boiler to produce thermal energy, CHP provides both energy services to a facility in one energy-efficient step.

CHP↗

Renewable hydrogen and ammonia for combined heat and power systems in remote locations: Optimal design and scheduling

Abstract Using hydrogen (H ) and ammonia (NH ) for renewable energy storage has the potential to enable economical power and heat supply with high renewable penetrations, especially in remote locations which are characterized by high energy costs. In this work we assess the economic competitiveness of renewable combined heat and power (CHP) systems in Mahaka HI, Nantucket MA, and Northwest Arctic Borough (NWAB) AK by optimally designing these systems for scenarios in which power and heat can be purchased over a range of historical energy prices as well as when 100% renewable supply is required. We use a combined optimal design and scheduling model which minimizes annualized net present cost by determining optimal technology selection and size simultaneously with optimal schedules for each period of a system operating horizon aggregated from full year hourly resolution data via a consecutive temporal clustering algorithm. We find that renewable generation meets at least 85% of power demands and 75% of heat demands under the lowest energy prices investigated. Higher conventional energy prices lead to increased renewable penetration which is facilitated by renewable NH as a seasonal energy storage medium, as are 100% renewable CHP systems. NH is used for power generation with heat cogeneration in all three locations, as well as directly for heating in NWAB. On an annual cost basis, NH ‐enabled 100% renewable CHP is only 3% more expensive in Mahaka and NWAB than systems which can purchase energy at the lowest prices, while it is 15% more expensive in Nantucket.

Palys, Matthew J.↗

Conservation of model degraded pine wood with selected organosilicons studied by XFM and nanoindentation

Previous research found that some organosilicon treatments proved effective in stabilizing waterlogged wood dimensions during drying. The present research aimed to determine the mechanism of wood stabilization by these chemicals to understand their mode of action. Here, the study used chemically (ChP) and biologically degraded (BP) model Scots pine wood treated with Methyltrimethoxysilane (MTMS), (3-Mercaptopropyl) trimethoxysilane (MPTMS), or 1,3-Bis(diethylamino)-3-propoxypropanol)-1,1,3,3-tetramethyldisiloxane (DEAPTMDS). Synchrotron-based X-ray fluorescence microscopy (XFM) was used to investigate the penetration of organosilicons into the wood cellular structure and cell walls, and nanoindentation was used to study the mechanical properties of the treated wood cell walls. All treatments resulted in high volumetric anti-shrink efficiency (ASE V ) values of 74-82%, except for MTMS-treated ChP with an ASE V of 52%. The multiscale XFM results revealed that all applied organosilicons penetrated throughout the whole wooden blocks and deposited in both cell lumina and cell walls. The retention of all applied organosilicons was highest in BP wood, and so was the dimensional stabilization effect. MTMS-treated ChP had the lowest measured cell wall infiltration, which likely contributed to its lower ASE v . DEAPTMDS treatments plasticized the cell walls and resulted in lowered nanoindentation elastic modulus (E s NI ) and hardness (H) for all types of wood. MTMS and MPTMS had modest effects on cell wall mechanical properties, and the effect depended on the type of wood. The final effect of organosilicon treatment on the dimensional wood stabilization and mechanical properties of wood cell walls depended not only on the type of the applied organosilicon but also the type of wood degradation. This means that the treatment cannot be considered universal, and specific approaches are needed for the conservation of individual wooden objects. Although some mechanisms are now better understood, such as the need for organosilicons to infiltrate the cell walls and the plasticizing effect of DEAPTMDS, other aspects will benefit from a more detailed analysis of the molecular interactions between organosilicons and wood polymers.

59 BASIC BIOLOGICAL SCIENCES↗

Application of thermal energy storage with electrified heating and cooling in a cold climate

Ground source heat pumps (GSHPs) have been shown to be an effective means of decarbonizing building heating and cooling, but the operation of these systems at scale presents challenges to sites and the grid due to increases in peak demand. Here, in this study, we investigate how the use of Thermal Energy Storage (TES), in the form of stratified water storage, could reduce the peak daily demand associated with GSHP systems and thus improve their cost effectiveness. This system was compared to a Combined Heat and Power (CHP) plant, to investigate the potential cost and emissions impacts of electrification on large energy users transitioning from high efficiency fossil fuel equipment. This study builds on previous research by using a significant campus area, and investigating the various impacts of an electrified system versus a state of the art fossil fuel system. An established method of TRNSYS modeling is used for the heat pumps and borehole heat exchangers (BHEs), along with the TES. The GSHP system with TES is modeled to follow industry standards and sized to provide an optimal balance of capital and operating costs. Costs were investigated for a unique large energy user rate structure, as well as for a more common generalized rate structure. The results show that the addition of TES to the GSHP system could reduce operating costs by 4.5%, but still incurs a 5.64% cost increase from the baseline CHP system. It is also shown, however, that a tactical integration of heat pumps into the CHP system is the most cost effective solution, only increasing the operating costs by 4.71%. Likewise, the impacts of different rate structures are highlighted, with the TES only resulting in 0.75% cost savings under the generalized utility rate. Furthermore, it is shown that thermal storage has great potential for demand reduction, with the addition of storage incurring a decrease of 7–22% in annual peak demand kW, dependent on the rate structure.

25 ENERGY STORAGE↗

Comparing the greenhouse gas emissions from three alternative waste combustion concepts

Highlights: Black-Right-Pointing-Pointer Significant GHG reductions are possible by efficient WtE technologies. Black-Right-Pointing-Pointer CHP and high power-to-heat ratio provide significant GHG savings. Black-Right-Pointing-Pointer N{sub 2}O and coal mine type are important in LCA GHG emissions of FBC co-combustion. Black-Right-Pointing-Pointer Substituting coal and fuel oil by waste is beneficial in electricity and heat production. Black-Right-Pointing-Pointer Substituting natural gas by waste may not be reasonable in CHP generation. - Abstract: Three alternative condensing mode power and combined heat and power (CHP) waste-to-energy concepts were compared in terms of their impacts on the greenhouse gas (GHG) emissions from a heat and power generation system. The concepts included (i) grate, (ii) bubbling fluidised bed (BFB) and (iii) circulating fluidised bed (CFB) combustion of waste. The BFB and CFB take advantage of advanced combustion technology which enabled them to reach electric efficiency up to 35% and 41% in condensing mode, respectively, whereas 28% (based on the lower heating value) was applied for the grate fired unit. A simple energy system model was applied in calculating the GHG emissions in different scenarios where coal or natural gas was substituted in power generation and mix of fuel oil and natural gas in heat generation by waste combustion. Landfilling and waste transportation were not considered in the model. GHG emissions were reduced significantly in all of the considered scenarios where the waste combustion concepts substituted coal based power generation. With the exception of condensing mode grate incinerator the different waste combustion scenarios resulted approximately in 1 Mton of fossil CO{sub 2}-eq. emission reduction per 1 Mton of municipal solid waste (MSW) incinerated. When natural gas based power generation was substituted by electricity from the waste combustion significant GHG emission reductions were not achieved.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Formation of the N≡N Triple Bond from Reductive Coupling of a Paramagnetic Diruthenium Nitrido Compound

Construction of nitrogen–nitrogen triple bonds via homocoupling of metal nitrides is an important fundamental reaction relevant to a potential Nitrogen Economy. Here, we report that room temperature photolysis of Ru 2 (chp) 4 N 3 (chp– = 2-chloro-6-hydroxypyridinate) in CH 2 Cl 2 produces N 2 via reductive coupling of Ru2(chp)4N nitrido species. Computational analysis reveals that the nitride coupling transition state (TS) features an out-of-plane “zigzag” geometry instead of the anticipated planar zigzag TS. However, with intentional exclusion of dispersion correction, the planar zigzag TS geometry can also be found. Both the out-of-plane and planar zigzag TS geometries feature two important types of orbital interactions: (1) donor–acceptor interactions involving intermolecular donation of a nitride lone pair into an empty Ru–N π* orbital and (2) Ru–N π to Ru–N π* interactions derived from coupling of nitridyl radicals. The relative importance of these two interactions is quantified both at and after the TS. Our analysis shows that both interactions are important for the formation of the N–N σ bond, while radical coupling interactions dominate the formation of N–N π bonds. Comparison is made to isoelectronic Ru 2 -oxo compounds. Formation of an O–O bond via bimolecular oxo coupling is not observed experimentally and is calculated to have a much higher TS energy. As a result, the major difference between the nitrido and oxo systems stems from an extremely large driving force, ~–500 kJ/mol, for N–N coupling vs a more modest driving force for O–O coupling, –40 to –140 kJ/mol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗