Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALORIMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Radiation Tolerant Electronics and Digital Processing for the Phase-I Trigger Readout Upgrade of the ATLAS Liquid Argon Calorimeters

The high luminosities of L > 10{sup 34} cm{sup -2}s{sup -1} at the Large Hadron Collider (LHC) at CERN produce an intense radiation environment that the detectors and their electronics must withstand. The ATLAS detector is a multi-purpose apparatus constructed to explore the new particle physics regime opened by the LHC. Of the many decay particles observed by the ATLAS detector, the energy of the created electrons and photons is measured by a sampling calorimeter technique that uses Liquid Argon (LAr) as its active medium. The front end (FE) electronic readout of the ATLAS LAr calorimeter located on the detector itself consists of a combined analog and digital processing system. In order to exploit the higher luminosity while keeping the same trigger bandwidth of 100 kHz, higher transverse granularity, higher resolution and longitudinal shower shape information will be provided from the LAr calorimeter to the Level-l trigger processors. New trigger readout electronics have been designed for this purpose, which will withstand the radiation dose levels expected for an integrated luminosity of 3000 fb{sup -1} during the high luminosity LHC (HL-LHC), which is well above the original LHC design qualifications. (authors)

43 PARTICLE ACCELERATORS↗

The ATLAS Tile Calorimeter

TileCal is the Hadronic calorimeter covering the most central region of the ATLAS experiment at the LHC. It uses iron plates as absorber and plastic scintillating tiles as the active material. Scintillation light produced in the tiles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs). The resulting electronic signals from the approximately 10000 PMTs are measured and digitised every 25 ns before being transferred to off-detector data-acquisition systems. This contribution will review in a first part the performances of the calorimeter during run 1, obtained from calibration data, and from studies of the response of particles from collisions. In a second part it will present the solutions being investigated for the ongoing and future upgrades of the calorimeter electronics. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of fast timing capabilities of silicon sensors for the CMS high granularity calorimeter at HL-LHC

The High Granularity Calorimeter (HGCAL) is the technology choice of the CMS collaboration for the endcap calorimetry upgrade planned to cope with the harsh radiation and unprecedented in-time event pileup projected at the High Luminosity-LHC era. In this context, profiting from fast-timing information with a resolution of a few tens of picoseconds embedded in the calorimeter would represent a unique capability for resolving information from individual collisions at the HL-LHC. This will enhance the reconstruction and physics capabilities of the CMS detector in terms of pileup mitigation and particle identification. The HGCAL is realized as a sampling calorimeter that uses silicon sensors as its active elements. Prototype sensors were tested with high-energy electron beams at the CERN SPS, and at the FNAL FTBF test beam facilities. We present the motivation for this studies including the concept and use of fast-timing in the HGCAL, and the measured intrinsic timing capabilities of silicon sensors for electromagnetic showers and minimum-ionizing particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons

The ionization signals in the liquid argon of the ATLAS electromagnetic calorimeter are studied in detail using cosmic muons. In particular, the drift time of the ionization electrons is measured and used to assess the intrinsic uniformity of the calorimeter gaps and estimate its impact on the constant term of the energy resolution. The drift times of electrons in the cells of the second layer of the calorimeter are uniform at the level of 1.3% in the barrel and 2.8% in the endcaps. This leads to an estimated contribution to the constant term of (0.29$+0.05\atop{-0.04}$) % in the barrel and (0.54$+0.06\atop{-0.04}$)% in the endcaps. Lastly, the same data are used to measure the drift velocity of ionization electrons in liquid argon, which is found to be 4.61 ± 0.07 mm/μs at 88.5 K and 1 kV/mm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improving topological cluster reconstruction using calorimeter cell timing in ATLAS

Clusters of topologically connected calorimeter cells around cells with large absolute signal-to-noise ratio (topo-clusters) are the basis for calorimeter signal recon struction in the ATLAS experiment. Topological cell clus tering has proven performant in LHC Runs 1 and 2. It is, however, susceptible to out-of-time pile-up of signals from soft collisions outside the 25 ns proton-bunch-crossing window associated with the event’s hard collision. To reduce this effect, a calorimeter-cell timing criterion was added to the signal-to-noise ratio requirement in the clustering algorithm. Multiple versions of this criterion were tested by reconstructing hadronic signals in simulated events and Run 2 ATLAS data. The preferred version is found to reduce the out-of-time pile-up jet multiplicity by ~50% for jet p T ~ 20 GeV and by ~80% for jet p T ≳ 50 GeV, while not disrupting the reconstruction of hadronic signals of interest, and improving the jet energy resolution by up to 5% for 20 < p T < 30 GeV. Pile-up is also suppressed for other physics objects based on topo-clusters (electrons, photons, τ-leptons), reducing the overall event size on disk by about 6% in early Run 3 pile up conditions. Offline reconstruction for Run 3 includes the timing requirement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Isothermal Battery Calorimeter Technology Transfer and Development: Cooperative Research and Development Final Report

During the last 15 years, NREL has been utilizing its unique expertise and capabilities to work with industry partners on battery thermal testing and electric and hybrid vehicle simulation and testing. Further information and publications about NREL’s work and unique capabilities in battery testing and modeling can be found at NREL’s Energy Storage website: http://www.nrel.gov/vehiclesandfuels/energystorage/. Particularly, NREL has developed and fabricated a large volume isothermal battery calorimeter that has been made available for licensing and potential commercialization (http://techportal.eere.energy.gov/technology.do/techID=394). In summer of 2011, NREL developed and fabricated a smaller version of the large volume isothermal battery calorimeter, called hereafter “cell-scale LVBC.” NETZSCH Instruments North America, LLC is a leading company in thermal analysis, calorimetry, and determination of thermo-physical properties of materials (www.netzschthermal-analysis.com). NETZSCH is interested in evaluation and eventual commercialization of the NREL large volume isothermal battery calorimeter.

25 ENERGY STORAGE↗

Same sign dimuon search for heavy majorana mass neutrinos at the CMS experiment at CERN and design studies of a quartz plate calorimeter prototype

This paper consists of two studies: the results of a search for heavy Majorana neutrinos (N) using an event signature defined by two like-sign charged muons and two jets, and the results from studies of a prototype quartz plate calorimeter. The data in the Majorana search correspond to an integrated luminosity of 5.0 fb$^{−1}$ of pp collisions at a centre-of-mass energy of 7 TeV collected with the CMS detector at the Large Hadron Collider. No excess of events are observed beyond the expected standard model background and therefore upper limits are set on the square of the mixing element, $|V_{\mu N} |$as a function of Majorana neutrino mass. These are the first direct upper limits on the heavy Majorana-neutrino mixing for m$_N$ > 90 GeV . The second part of this thesis is the results of performance tests of a 20-layer quartz plate calorimeter prototype. The calorimeter prototype was tested at the CERN H2 area in hadronic and electromagnetic configurations, at various en ergies of pion and electron beams. The beam test and simulation results of this prototype are reported.

43 PARTICLE ACCELERATORS↗

Mu2e Calorimeter Clustering Studies [Slides]

aMu2e (muon-to-electron-conversion), an Intensity Frontier experiment at Fermilab set to begin data taking in 2022, will search for flavor violation in charged leptons with a muon decaying to only an electron without any neutrinos. Protons will be accelerated by the 8GeV proton beam before reaching Mu2e’s production target. From there, pions enter an S-shaped Transport Solenoid and travel through a series of absorbers and collimators to select low-energy negatively charged muons from pion decay that will hit the stopping target. Downstream from the stopping target are a curved straw tracker and two annular disk crystal calorimeters. The signal will be a mono-energetic e- with an energy close to the rest mass of a muon. The Mu2e expected single event sensitivity is 2.87e-17. The complimentary trigger strategy will take advantage of both online track searches from the tracker and calorimeter reconstruction. The trigger requires a rejection factor greater than 100 and m ust make its decision within a 3ms time budget. In order to provide high efficiency on signal events, our calorimeter clustering algorithms must be accurate and meet the timing performance. I will discuss the expected performance of two clustering algorithms: a fast algorithm to be used at the trigger level and a more accurate clustering algorithm to be used in the offline reconstruction. The fast algorithm defines clusters by only selecting crystals adjacent to a high energy crystal seed. The full-blown algorithm can find smaller clusters separated from the main cluster, within a distance and timing window, and combine them into one cluster. We have analyzed the topology of the reconstructed clusters by the two algorithms on events with only a conversion electron and combined signal and background events. The goal of these studies is to improve the performance of the fast algorithm to better reconstruct the cluster energy and work within the strict timing budget.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of the Cooling System of the Mu2e Electromagnetic Calorimeter at Fermi National Accelerator Laboratory

In this Thesis, the cooling of the electronics of the Mu2e calorimeter has been discussed. The analysed technical solutions for the cooling of the front-end boards, the waveform digitizers boards and the interface boards have been presented. The project of the crate has been showed in detail. It is placed in the outer surface of the calorimeter disk and it is a mechanical support for the boards and also part of the thermal circuit. The distributing system of the refrigerant fluid for the whole calorimeter has been analysed too. Then the manufacturing solutions of the crates and the components for the thermal path have been developed. At the end, the main experimental tests have been presented. They are going to be realized in the next months.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CMS High Granularity Calorimeter ECON-D ASIC overview and radiation testing results

The Compact Muon Solenoid (CMS) Experiment’s High Granularity Calorimeter (HGCAL) upgrade replaces the CMS electromagnetic and hadronic endcap calorimeters in preparation for the high-rate and high-radiation environment of the High Luminosity LHC. To effectively use the over 6 million channels of this highly-segmented “imaging” calorimeter, CMS is pioneering very front-end data compression with the Endcap Concentrator (ECON) ASICs – the ECON-T for the trigger path and the ECON-D for the data path. These 65 nm CMOS ASICs are radiation tolerant (200 Mrad) and low-power (< 2.5 mW/channel). In June 2023, we received the first full-functionality prototype of the data path concentrator ASIC, the ECON-D-P1. This talk will present an overview of the ECON-D-P1, summarize functionality and system testing, and present results from both Total Ionizing Dose (TID) and Single Event Effect (SEE) testing campaigns completed in summer 2023, validating the ECON-D radiation tolerant performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Jefferson Lab Eta Factory Experiment and Applications of PbWO4 Calorimeters in Future Experimental Facilities

The goal of the new JLab Eta Factory (JEF) experiment, conducted with the GlueX detector in Hall D at Jefferson Lab, is to perform measurements of various ¿(') decays with a primary focus on rare neutral modes. The experiment’s physics program ranges from precision tests of low-energy QCD to searches for gauge bosons with masses below 1 GeV that could couple the Standard Model (SM) sector to the dark sector. The experiment will collect a high-statistics data sample of ¿(') mesons produced via a beam of tagged photons. The GlueX detector features a large, nearly uniform acceptance for both neutral and charged particles, enabling efficient identification of complex multi-particle final states. To meet the requirements of the JEF experiment, the inner section of the forward lead-glass calorimeter in the GlueX detector has been upgraded with lead tungstate (PbWO4) scintillating crystals. PbWO4 offers exceptional characteristics, such as a small radiation length and Molire radius, and large light yield, that make it ideal for constructing high- granularity, high-resolution, radiation-hard detectors. These properties enable excellent spatial separation and energy resolution of reconstructed electromagnetic showers, establishing PbWO4 as the material of choice for many high-precision experiments. The JEF experiment began data collection in April 2025 and will operate concurrently with the GlueX experiment, whose primary objective is the search for gluonic excitations in the meson spectrum. I will give an overview of the JEF experiment, the GlueX detector, and the feasibility of further upgrades to support future ¿ physics studies. Special attention will be given to the newly constructed PbWO4 scintillating calorimeter and recent advancements in calorimeter instrumentation.

Somov, Alexander↗

Final Design and Current Status of the Mu2e Crystal Calorimeter

The Mu2e experiment at Fermi National Accelerator Laboratory will search for the CLFV neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus. The Mu2e design has been studied to improve the single event sensitivity of four orders of magnitude with respect to the previous experiments and provide an indirect probe for New Physics energy scales up to thousands TeV. Mu2e is composed of a tracker, an electromagnetic calorimeter, and an external veto for cosmic rays. The calorimeter provides a powerful particle identification and an online trigger while operating in a harsh environment. We report on the status of the calorimeter components production, the quality assurance tests, and the tests performed with a reduced-scale prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calorimeter accurately measures thermal radiation energy

Calorimeter accurately measures steady-state and transient, low-level thermal radiation energy. The calorimeter uses a compensating shield between the sensor and the calorimeter mount to intercept sensor heat losses and to provide a reference for determining a correction factor.

Anderson, W. W., Jr.↗

Precision closed bomb calorimeter for testing flame and gas producing initiators

A calorimeter has been developed under this study to help meet the needs of accurate performance monitoring of electrically or mechanically actuated flame and gas producing devices, such as squib-type initiators. A ten cubic centimeter closed bomb (closed volume) calorimeter was designed to provide a standard pressure trace and to measure a nominal 50 calorie output, using the basic components of a Parr Model 1411 calorimeter. Two prototype bombs were fabricated, pressure tested to 2600 psi, and extensively evaluated.

Carpenter, D. R., Jr.↗

Heat flow calorimeter

Heat flow calorimeter devices are used to measure heat liberated from or absorbed by an object. This device is capable of measuring the thermal output of sealed nickel-cadmium batteries or cells during charge-discharge cycles. An elongated metal heat conducting rod is coupled between the calorimeter vessel and a heat sink, thus providing the only heat exchange path from the calorimeter vessel itself.

Fletcher, J. C.↗

Design of experiments for measuring heat-transfer coefficients with a lumped-parameter calorimeter

A theoretical investigation was conducted to determine optimum experimental conditions for using a lumped-parameter calorimeter to measure heat-transfer coefficients and heating rates. A mathematical model of the transient temperature response of the calorimeter was used with the measured temperature response to predict the heat-transfer coefficient and the rate of heating. A sensitivity analysis was used to determine the optimum transient experiment for simultaneously measuring the heat addition during heating and the convective heat-transfer coefficient during heating and cooling of a lumped-parameter calorimeter. Optimum experiments were also designed for measuring the convective heat-transfer coefficient during both heating and cooling and cooling only.

Vanfossen, G. J., Jr.↗

Evaluation of a bulk calorimeter and heat balance for determination of supersonic combustor efficiency

Results are presented from the shakedown and evaluation test of a bulk calorimeter. The calorimeter is designed to quench the combustion at the exit of a direct-connect, hydrogen fueled, scramjet combustor model, and to provide the measurements necessary to perform an analysis of combustion efficiency. Results indicate that the calorimeter quenches reaction, that reasonable response times are obtained, and that the calculated combustion efficiency is repeatable within + or -3 percent and varies in a regular way with combustor model parameters such as injected fuel equivalence ratio.

Mcclinton, C. R.↗