Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALIBRATION STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Reliably Detectable Flaw Size for NDE Methods that Use Calibration

Probability of detection (POD) analysis is used in assessing reliably detectable flaw size in nondestructive evaluation (NDE). MIL-HDBK-1823 and associated mh1823 POD software gives most common methods of POD analysis. In this paper, POD analysis is applied to an NDE method, such as eddy current testing, where calibration is used. NDE calibration standards have known size artificial flaws such as electro-discharge machined (EDM) notches and flat bottom hole (FBH) reflectors which are used to set instrument sensitivity for detection of real flaws. Real flaws such as cracks and crack-like flaws are desired to be detected using these NDE methods. A reliably detectable crack size is required for safe life analysis of fracture critical parts. Therefore, it is important to correlate signal responses from real flaws with signal responses form artificial flaws used in calibration process to determine reliably detectable flaw size.

Koshti, Ajay M.↗

Uncertainty Budget for Detector-Based Absolute Radiometric Calibration With GLAMR

The accuracy of the absolute radiometric calibration (RadCal) for remote sensing instruments is essential to their wide range of applications. The uncertainty associated to the traditional source-based RadCal method is assessed at a 2% (k=1) or higher level for radiance measurement. To further improve the accuracy to meet the demands of climate studies, a detector-based approach using tunable lasers as a light source has been devised. The Goddard Laser for Absolute Measurement of Radiance, known as the GLAMR system, is a notable example of the incorporation of such technology. Using transfer radiometers calibrated at NIST as calibration standards, the absolute spectral response (ASR) function of a remote sensing instrument is measured with its uncertainty traceable to the International System of Units. This paper presents a comprehensive uncertainty analysis of the detector-based absolute RadCal using the GLAMR system. It identifies and examines uncertainty sources during the GLAMR RadCal test, including those from the GLAMR system, the testing configuration, and data processing methodologies. Analysis is carried out to quantify the contribution of each source and emphasize the most influential factors. It is shown that the calibration uncertainty of GLAMR RadCal can be better than 0.3% (k=1) in the wavelength range of 350-950 nm and 0.6% (k=1) between 950-2300 nm, with the exception of regions with strong water absorption. In addition, recommendations are made to refine the calibration process to further reduce the uncertainty.

Zhipeng Wang↗

Development and Comparison of Purgeable Mercury Values in SRR Samples Measured by SRNL and Eurofins FGS

Savannah River Remediation (SRR) requested the development of mercury speciation capabilities at the Savannah River National Laboratory (SRNL) to support the Liquid Waste Operations at SRS. As part of that method development, SRR requested that SRNL Analytical Development (AD) compare their results with those obtained from their outside contract laboratory, Eurofins Frontier Global Sciences (FGS). This document reports on this method development work as well as the comparative analyses conducted between the two laboratories. Development, optimization, and validation were undertaken at SRNL to produce a method for the species-specific analysis of dissolved gaseous mercury (DGM) in samples from SRR. It was determined that DGM present in SRR samples represented a combination of various soluble and volatile mercury species- and is thus referred to in this document as purgeable mercury. A method has been developed and analytically validated for the analysis of purgeable mercury in caustic nuclear waste. Using multivariate optimization method, purge flow rate was determined to be highly correlated with increased response (p=0.023). Total recovery of spiked purgeable mercury from deionized water was 99.4 ±10.6% and 91.6 ±14.9% from spiked high-activity tank waste samples. Calibration, by external calibration and standard addition calibration, maintained a mean accuracy of 101 ±5% and 99.9 ±1.7%, respectively. This method represents a decrease in sample handling and processing over currently standard methods and represents a more amenable method for purgeable mercury analysis in liquid nuclear waste.1 An interlaboratory comparison was performed between SRNL and Eurofins FGS in the co-analysis of three quarterly Tank 50 samples. Two samples demonstrated no statistically significant difference (p=0.271, p=0.0811), with one sample biased 30% low to a statistically significant degree (p=0.0432). Large mean uncertainty was present in the results reported by both laboratories (±15% and 40% from SRNL and Eurofins), with no significant difference observed in uncertainty (p=0.934). Across all co-analyzed samples, no significantly difference was observed in precision (p=0.205) or reported values (p=0.352) between SRNL and Eurofins. These results indicate that SRNL-AD may provide data to the customer of statistically similar quality.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Precision Spectrophotometric Calibration System for Dark Energy Instruments

For this research we build a precision calibration system and carried out measurements to demonstrate the precision that can be achieved with a high precision spectrometric calibration system. It was shown that the system is capable of providing a complete spectrophotometric calibration at the sub-pixel level. The calibration system uses a fast, high precision monochromator that can quickly and efficiently scan over an instrument’s entire spectral range with a spectral line width of less than 0.01 nm corresponding to a fraction of a pixel on the CCD. The system was extensively evaluated in the laboratory. Our research showed that a complete spectrophotometric calibration standard for spectroscopic survey instruments such as DESI is possible. The monochromator precision and repeatability to a small fraction of the DESI spectrograph LSF was demonstrated with re-initialization on every scan and thermal drift compensation by locking to multiple external line sources. A projector system that mimics telescope aperture for point source at infinity was demonstrated.

79 ASTRONOMY AND ASTROPHYSICS↗

Chemometrics and Experimental Design for the Quantification of Nitrate Salts in Nitric Acid: Near-Infrared Spectroscopy Absorption Analysis

Implementing remote, real-time spectroscopic monitoring of radiochemical processing streams in hot cell environments requires efficiency and simplicity. The success of optical spectroscopy for the quantification of species in chemical systems highly depends on representative training sets and suitable validation sets. Selecting a training set (i.e., calibration standards) to build multivariate regression models is both time- and resource-consuming using standard one-factor-at-a-time approaches. This study describes the use of experimental design to generate spectral training sets and a validation set for the quantification of sodium nitrate (0–1 M) and nitric acid (0.1–10 M) using the near-infrared water band centered at 1440 nm. Partial least squares regression models were built from training sets generated by both D- and I-optimal experimental designs and a one-factor-at-a-time approach. The prediction performance of each model was evaluated by comparing the bias and standard error of prediction for statistical significance. D- and I-optimal designs reduced the number of samples required to build regression models compared with one-factor-at-a-time while also improving performance. Models must be confirmed against a validation sample set when minimizing the number of samples in the training set. The D-optimal design performed the best when considering both performance and efficiency by improving predictive capability and reducing number of samples in the training set by 64% compared with the one-factor-at-a-time approach. The experimental design approach objectively selects calibration and validation spectral data sets based on statistical criterion to optimize performance and minimize resources.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Self-Calibration of BICEP1 Three-Year Data and Constraints on Astrophysical Polarization Rotation

Cosmic microwave background (CMB) polarimeters aspire to measure the faint B-mode signature predicted to arise from inflationary gravitational waves. They also have the potential to constrain cosmic birefringence, rotation of the polarization of the CMB arising from parity-violating physics, which would produce nonzero expectation values for the CMB's temperature to B-mode correlation (TB) and E-mode to B-mode correlation (EB) spectra. However, instrumental systematic effects can also cause these TB and EB correlations to be nonzero. In particular, an overall miscalibration of the polarization orientation of the detectors produces TB and EB spectra which are degenerate with isotropic cosmological birefringence, while also introducing a small but predictable bias on the BB spectrum. We find that BICEP1 three-year spectra, which use our standard calibration of detector polarization angles from a dielectric sheet, are consistent with a polarization rotation of alpha = −2.77deg +/- 0.86deg (statistical) +/- 1.3deg (systematic). We have revised the estimate of systematic error on the polarization rotation angle from the two-year analysis by comparing multiple calibration methods. We also account for the (negligible) impact of measured beam systematic effects. We investigate the polarization rotation for the BICEP1 100 GHz and 150 GHz bands separately to investigate theoretical models that produce frequency-dependent cosmic birefringence. We find no evidence in the data supporting either of these models or Faraday rotation of the CMB polarization by the Milky Way galaxy's magnetic field. If we assume that there is no cosmic birefringence, we can use the TB and EB spectra to calibrate detector polarization orientations, thus reducing bias of the cosmological B-mode spectrum from leaked E-modes due to possible polarization orientation miscalibration. After applying this "self-calibration" process, we find that the upper limit on the tensor-to-scalar ratio decreases slightly, from r < 0.70 to r < 0.65 at 95% confidence.

three-year↗

Succinonitrile Purification Facility

The Succinonitrile (SCN) Purification Facility provides succinonitrile and succinonitrile alloys to several NRA selected investigations for flight and ground research at various levels of purity. The purification process employed includes both distillation and zone refining. Once the appropriate purification process is completed, samples are characterized to determine the liquidus and/or solidus temperature, which is then related to sample purity. The lab has various methods for measuring these temperatures with accuracies in the milliKelvin to tenths of milliKelvin range. The ultra-pure SCN produced in our facility is indistinguishable from the standard material provided by NIST to well within the stated +/- 1.5mK of the NIST triple point cells. In addition to delivering material to various investigations, our current activities include process improvement, characterization of impurities and triple point cell design and development. The purification process is being evaluated for each of the four vendors to determine the efficacy of each purification step. We are also collecting samples of the remainder from distillation and zone refining for analysis of the constituent impurities. The large triple point cells developed will contain SCN with a melting point of 58.0642 C +/- 1.5mK for use as a calibration standard for Standard Platinum Resistance Thermometers (SPRTs).

Source record↗

Calcium fluoride as a dominating matrix for quantitative analysis by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS): A feasibility study

Here, calcium fluoride formed by the reaction between ammonium bifluoride and calcium chloride was investigated as a dominating matrix for quantitative analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Transformation from a solid sample to the calcium fluoride-based matrix permitted quantitative analysis based on calibration standards made from elemental standards. A low abundance stable calcium isotope, i.e. 44 Ca + , was monitored as the internal standard for quantitative analysis by LA-ICP-MS. Correlation coefficient factors for multiple elements were obtained with values over 0.999. The results for multiple elements in a certified reference material of soil (NIST SRM 2710a) agreed with the certified values in the range of expanded uncertainty, indicating the present method was valid for quantitation of elements in solid samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lessons Learned in Building Long-Term Multi-Satellite Global Precipitation Records

Efforts to construct long-term global precipitation data sets from the decades-long record of satellite (and other) data historically have fallen into one of two categories. Climate Data Records (CDR), such as the Global Precipitation Climatology Project (GPCP), prioritize homogeneity over fine-scale accuracy. On the other hand, High Resolution Precipitation Products (HRPP), such as the Tropical Rainfall Measuring Mission (TRMM) Multi-satellite Precipitation Analysis (TMPA), emphasize the use of data from all available satellites. For both types of products, experience has shown that it is critical to choose the appropriate reference standard to intercalibrate an ever-evolving constellation of satellite sensors. Towards this end, we have used passive microwave (PMW) in developing GPCP, and combined PMW-radar in TMPA.The launch of the TRMM follow-on Global Precipitation Measurement (GPM) mission in 2014 gave birth to several nearly-global HRPP's, including the Integrated Multi-satellitE Retrievals for GPM (IMERG). Our strategy in refining IMERG has been to first focus on the tropics and mid-latitudes, where we have relatively high confidence, and only more recently begin to expand into the lower-confidence high latitudes. Similarly, although GPCP has provided nearly-global estimates since its inception in the early 1990's, the advent of sensors such as CloudSat has facilitated new efforts to modernize its estimates at high latitudes.For each of these data sets, it is expected that the final merged estimate should tend to track along with its respective calibration standard. Time series depicting GPCP, TMPA, and IMERG will be presented, in order to demonstrate the extent to which this is so. Additionally, comparisons amongst the products will show areas of agreement and highlight areas where further improvements are needed.

Nelkin, Eric J.↗

Analysis and imaging of boron distribution in maize by quantitative neutron capture radiography

Quantitative neutron capture radiography (QNCR) of 10 B found in pre-dried maize samples has been conducted. Calibration standards constructed from filter paper mimicked plant tissues to reduce confounding matrix effects. A mathematical track elimination method improves the LOD as well as the visual contrast image at low boron concentration levels. The LOD for total boron is 1.7 µg/g in a 4 mm 2 region of interest (ROI). The w(B) in five individual maize tassel meristems has been determined to be 14.9 µg/g – 21.2 µg/g.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Prototype development and test results of a continuous ambient air monitoring system for hydrazine at the 10 ppb level

A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.

Meneghelli, Barry↗

Correction of Q Factor Effects for Simultaneous Collection of Elemental Analysis and Relaxation Times by Nuclear Magnetic Resonance

A new method for measurement of elemental analysis by nuclear magnetic resonance (NMR) of unknown samples is discussed in this report as a quick and robust means to measure elemental ratios without the use of internal or external calibration standards. The determination of elemental ratios was done by normalizing the signal intensities by the frequency dependent quality factor (Q) and the gyromagnetic ratios (γ) for each measured nucleus. The correction for the frequency dependence was found by characterizing the output signal of the probe as a function of the quality factor (Q) and the frequency, and the correction for γ was discussed in a previous study. A Carr–Purcell–Meiboom–Gill (CPMG) pulse sequence was used for evaluation of the relative signal intensities, which allows for derivation of elemental ratios, and was correspondingly used to simultaneously measure the T 2 * of samples for an added parameter for more accurate identification of unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and Comparison of Purgeable Mercury Values in SRR Samples Measured by SRNL and Eurofins FGS

Savannah River Remediation (SRR) requested the development of mercury speciation capabilities at the Savannah River National Laboratory (SRNL) to support the Liquid Waste Operations at SRS. As part of that method development, SRR requested that SRNL Analytical Development (AD) compare their results with those obtained from their outside contract laboratory, Eurofins Frontier Global Sciences (FGS). This document reports on this method development work performed at SRNL as well as the comparative analyses conducted between the two laboratories. Development, optimization, and validation were undertaken at SRNL to produce a method for the species-specific analysis of dissolved gaseous mercury (DGM) in samples from SRR. It was determined that DGM present in SRR samples represented a combination of various soluble and volatile mercury species- and is thus referred to in this document as purgeable mercury. A method has been developed and analytically validated for the analysis of purgeable mercury in caustic nuclear waste. Using multivariate optimization, an efficient and sensitive method was produced. Total recovery of spiked purgeable mercury from deionized water was 99.4 ±10.6% and 91.6 ±14.9% from spiked high-activity tank waste samples. Calibration, by external calibration and standard addition calibration, maintained a mean accuracy of 101 ±5% and 99.9 ±1.7%, respectively. An interlaboratory comparison was performed between SRNL and Eurofins FGS in the co-analysis of three quarterly SRR Tank 50 samples. The statistical evaluations presented in this document support the following conclusions: for internal validation data, the two laboratories demonstrate biases of -4.3% for SRNL and 4.4% for Eurofins FGS, though neither are statistically significant at the 5% level. While the percent relative standard deviation for each of the laboratories is rather large (21.5% for SRNL and 18.4% for Eurofins FGS), there is no indication of a statistically significant difference between the two laboratories in the precision of these results. For the three sets of SRR quarterly Tank 50 samples, there is no indication of a statistically significant bias between the two laboratories at the 5% significance level. These results indicate that SRNL may provide data to the customer of statistically similar quality to Eurofins FGS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spatial Heterodyne Raman Spectrometer (SHRS) for In Situ Chemical Sensing Using Sapphire and Silica Optical Fiber Raman Probes

A spatial heterodyne Raman spectrometer (SHRS), constructed using a modular optical cage and lens tube system, is described for use with a commercial silica and a custom single-crystal (SC) sapphire fiber Raman probe. The utility of these fiber-coupled SHRS chemical sensors is demonstrated using 532 nm laser excitation for acquiring Raman measurements of solid (sulfur) and liquid (cyclohexane) Raman standards as well as real-world, plastic-bonded explosives (PBX) comprising 1,3,5- triamino- 2,4,6- trinitrobenzene (TATB) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) energetic materials. The SHRS is a fixed grating-based dispersive interferometer equipped with an array detector. Each Raman spectrum was extracted from its corresponding fringe image (i.e., interferogram) using a Fourier transform method. Raman measurements were acquired with the SHRS Littrow wavelength set at the laser excitation wavelength over a spectral range of ∼1750 cm −1 with a spectral resolution of ∼8 cm −1 for sapphire and ∼10 cm −1 for silica fiber probes. The large aperture of the SHRS allows much larger fiber diameters to be used without degrading spectral resolution as demonstrated with the larger sapphire collection fiber diameter (330 μm) compared to the silica fiber (100 μm). Unlike the dual silica fiber Raman probe, the dual sapphire fiber Raman probe did not include filtering at the fiber probe tip nearest the sample. Even so, SC sapphire fiber probe measurements produced less background than silica fibers allowing Raman measurements as close as ∼85 cm −1 to the excitation laser. Despite the short lengths of sapphire fiber used to construct the sapphire probe, well-defined, sharp sapphire Raman bands at 420, 580, and 750 cm −1 were observed in the SHRS spectra of cyclohexane and the highly fluorescent HMX-based PBX. SHRS measurements of the latter produced low background interference in the extracted Raman spectrum because the broad band fluorescence (i.e., a direct current, or DC, component) does not contribute to the interferogram intensity (i.e., the alternating current, or AC, component). SHRS spectral resolution, throughput, and signal-to-noise ratio are also discussed along with the merits of using sapphire Raman bands as internal performance references and as internal wavelength calibration standards in Raman measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Field evaluation of semi‐automated moisture estimation from geophysics using machine learning

Geophysical methods can provide three-dimensional (3D), spatially continuous estimates of soil moisture. However, point-to-point comparisons of geophysical properties to measure soil moisture data are frequently unsatisfactory, resulting in geophysics being used for qualitative purposes only. This is because (1) geophysics requires models that relate geophysical signals to soil moisture, (2) geophysical methods have potential uncertainties resulting from smoothing and artifacts introduced from processing and inversion, and (3) results from multiple geophysical methods are not easily combined within a single soil moisture estimation framework. To investigate these potential limitations, an irrigation experiment was performed wherein soil moisture was monitored through time, and several surface geophysical datasets indirectly sensitive to soil moisture were collected before and after irrigation: ground penetrating radar, electrical resistivity tomography (ERT), and frequency domain electromagnetics (FDEM). Data were exported in both raw and processed form, and then snapped to a common 3D grid to facilitate moisture prediction by standard calibration techniques, multivariate regression, and machine learning. A combination of inverted ERT data, raw FDEM, and inverted FDEM data was most informative for predicting soil moisture using a random regression forest model (one-thousand 60/40 training/test cross-validation folds produced root mean squared errors ranging from 0.025–0.046 cm 3 /cm 3 ). This cross-validated model was further supported by a separate evaluation using a test set from a physically separate portion of the study area. Machine learning was conducive to a semi-automated model-selection process that could be used for other sites and datasets to locally improve accuracy.

54 ENVIRONMENTAL SCIENCES↗

Electropolymerized-molecularly imprinted polymers (E-MIPS) as sensing elements for the detection of dengue infection

Here, a straightforward in situ detection method for dengue infection was demonstrated through the molecular imprinting of a dengue nonstructural protein 1 (NS1) epitope into an electropolymerized molecularly imprinted polyterthiophene (E-MIP) film sensor. The key enabling step in the sensor fabrication is based on an epitope imprinting strategy, in which short peptide sequences derived from the original target molecules were employed as the main template for detection and analysis. The formation of the E-MIP sensor films was facilitated using cyclic voltammetry (CV) and monitored in situ by electrochemical quartz crystal microbalance (EC-QCM). Surface properties were analyzed using different techniques including atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and polarization modulation-infrared reflection-adsorption (PM-IRRAS). The standard calibration curve (R = 0.9830) was generated for the detection of the epitope, Ac-VHTWTEQYKFQ-NH 2 , with a linear range of 0.2 to 30 μg/mL and detection limit of 0.073 μg/mL. A separate calibration curve (R = 0.9786) was obtained using spiked buffered solutions of dengue NS1 protein, which resulted in a linear range of 0.2 to 10 μg/mL and a detection limit of 0.056 μg/mL. The fabricated E-MIP sensor exhibited long-term stability, high sensitivity, and good selectivity towards the targeted molecules. These results indicated that the formation of the exact and stable cavity imprints in terms of size, shape, and functionalities was successful. In our future work, we aim to use our E-MIP sensors for NS1 detection in real-life samples such as serum and blood.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an Absolute Gas-Counting Capability for Low to Medium Activities

ABSTRACT Pacific Northwest National Laboratory (PNNL) is developing a capability to measure the absolute activity concentration of various gaseous radionuclides using length-compensated proportional-counting methods. This capability will enable the validation and use of low-level, gaseous radionuclide calibration standards for use in PNNL’s shallow underground laboratory. Two sets of unequal length proportional counters have been fabricated. These detector assemblies operate on a static gas-fill principle, in contrast to continuous, flow-through configurations. One set of three counters has been fabricated using ultra-low background (ULB) electroformed copper and low-background fabrication methods. Once fully operational, these ULB counters will be used in PNNL’s shallow underground counting laboratory for analysis of gases with low activity concentrations < 1 Bq/cc. A second set of four unequal length counters has been fabricated from Oxygen-Free High-Conductivity Copper (OFHC) using similar low-background cleaning and assembly methods. These OFHC counters will be operated above ground in the analysis of gases with activity concentrations in the range of 1-10 Bq/cc. A gas delivery system is being developed to actively mix the analyte gas with an appropriate amount of count-gas and uniformly deliver it to the counters with high accuracy and repeatability. A description of both detector assemblies and gas delivery system will be given along with a preliminary uncertainty analysis of a simulated 0.05 Bq/cm3 gas measurement.

Williams, Richard M.↗