Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Biomedical optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Study of the prebreakdown stage of a gas discharge in a diode with point cathode by laser probing

The prebreakdown stage of a gas discharge in a diode with strongly overloaded cathode is studied by laser methods (by simultaneous use of multiframe interferometry and shadow and schlieren photographing) at atmospheric pressure. The spatial resolution of the methods is about 20 μm. A probing pulse of a laser (LS-2151 Nd: YAG laser with a half amplitude duration of 70 ps and a pulse energy of up to 40 mJ) is synchronized with a voltage pulse with accuracy of about 1 ns. High field strength at the cathode is achieved due to the use of thin individual metal tips on the electrodes. It is shown that the initial stage of breakdown of a discharge gap is accompanied by the emergence of a dense plasma cloud at the end of a tip with electron density of about 5 × 10{sup 19} cm{sup –3} with a size of tens of microns, as well as by a sharp increase in the total current through the diode. After the emergence of a dense plasma cloud at the end of a cathode tip, a similar cloud is formed on the surface of the anode; sometime later, these clouds join together and form a tubular current channel. The dynamics of the breakdown, as well as the parameters of the plasma are studied by the abovementioned techniques in three independent optical channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Designing Tripodal and Triangular Gadolinium Oxide Nanoplates and Self-Assembled Nanofibrils as Potential Multimodal Bioimaging Probes

Here, we report the shape-controlled synthesis of tripodal and triangular gadolinium oxide (Gd2O3) nanoplates. In the presence of lithium ions, the shape of the nanocrystals is readily controlled by tailoring reaction parameters such as temperature and time. We observe that the morphology transforms from an initial tripodal shape to a triangular shape with increasing reaction time or elevated temperatures. Highly uniform Gd2O3 nanoplates are self-assembled into nanofibril-like liquid-crystalline superlattices with long-range orientational and positional order. In addition, shape-directed self-assemblies are investigated by tailoring the aspect ratio of the arms of the Gd2O3 nanoplates. Due to a strong paramagnetic response, Gd2O3 nanocrystals are excellent candidates for MRI contrast agents and also can be doped with rare-earth ions to form nanophosphors, pointing to their potential in multimodal imaging. In this work, we investigate the MR relaxometry at high magnetic fields (9,4 and 14.1 T) and the optical properties including near-IR to visible upconversion luminescence and X-ray excited optical luminescence of doped Gd2O3 nanoplates. The complex shape of Gd2O3 nanoplates, coupled with their magnetic properties and their ability to phosphoresce under NIR or X-ray excitation which penetrate deep into tissue, makes these nanoplates a promising platform for multimodal imaging in biomedical applications.

Paik, T↗

High-energy proton imaging for biomedical applications

The charged particle community is looking for techniques exploiting proton interactions instead of X-ray absorption for creating images of human tissue. Due to multiple Coulomb scattering inside the measured object it has shown to be highly non-trivial to achieve sufficient spatial resolution. We present imaging of biological tissue with a proton microscope. This device relies on magnetic optics, distinguishing it from most published proton imaging methods. For these methods reducing the data acquisition time to a clinically acceptable level has turned out to be challenging. In a proton microscope, data acquisition and processing are much simpler. This device even allows imaging in real time. The primary medical application will be image guidance in proton radiosurgery. Proton images demonstrating the potential for this application are presented. As a result, tomographic reconstructions are included to raise awareness of the possibility of high-resolution proton tomography using magneto-optics.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of Materials for Use as Optical Phantoms

We present the results of optical characterization of silicon dioxide nanoparticle solutions. These are spherical particles with a controlled diameter between 100 nm and 600 nm. The importance of this work lies in using these solutions to develop a phantom with optical properties that closely match those of human breast tissue at near-IR wavelengths. Characterization involves illuminating the solution with a laser beam transmitted through a recipient of known width containing the solution. Resulting intensity profiles from the light spot are measured as function of the detector position. The experiments were realized using light with wavelengths 633 nm and 820 nm. Measured intensity profiles were fitted to the calculated profiles obtained from diffusion theory, using the method of images. Fitting results give us the absorption and transport scatter coefficients. These coefficients can be modified by changing the particle concentration of the solution. We found that these coefficients are the same order of magnitude as those of human tissue reported in published studies.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Sulfono-g-AApeptides as a New Class of Nonnatural Helical Foldamer

Foldamers offer an attractive opportunity for the design of novel molecules that mimic the structures and functions of proteins and enzymes including biocatalysis and biomolecular recognition. Herein we report a new class of nonnatural helical sulfono-g-AApeptide foldamers of varying lengths. The crystal structure of the sulfono-g-AApeptide monomer S6 illustrates the intrinsic folding propensity of sulfono-g-AApeptides, which likely originates from the bulkiness of tertiary sulfonamide moiety. The two-dimensional solution NMR spectroscopy data for the longest sequence S1 demonstrates a 10/16 right-handed helical structure. Optical analysis using circular dichroism further supports welldefined helical conformation of sulfono-g-AApeptides in solution containing as few as five building blocks. Future development of sulfono-g-AApeptides may lead to new foldamers with discrete functions, enabling expanded application in chemical biology and biomedical sciences.

2D NMR spectroscopy↗

Accuracy evaluation of the optical surface monitoring system on EDGE linear accelerator in a phantom study

Frameless stereotactic radiosurgery (SRS) requires dedicated systems to monitor the patient position during the treatment to avoid target underdosage due to involuntary shift. The optical surface monitoring system (OSMS) is here evaluated in a phantom-based study. The new EDGE linear accelerator from Varian (Varian, Palo Alto, CA) integrates, for cranial lesions, the common cone beam computed tomography (CBCT) and kV-MV portal images to the optical surface monitoring system (OSMS), a device able to detect real-time patient's face movements in all 6 couch axes (vertical, longitudinal, lateral, rotation along the vertical axis, pitch, and roll). We have evaluated the OSMS imaging capability in checking the phantoms' position and monitoring its motion. With this aim, a home-made cranial phantom was developed to evaluate the OSMS accuracy in 4 different experiments: (1) comparison with CBCT in isocenter location, (2) capability to recognize predefined shifts up to 2° or 3 cm, (3) evaluation at different couch angles, (4) ability to properly reconstruct the surface when the linac gantry visually block one of the cameras. The OSMS system showed, with a phantom, to be accurate for positioning in respect to the CBCT imaging system with differences of 0.6 ± 0.3 mm for linear vector displacement, with a maximum rotational inaccuracy of 0.3°. OSMS presented an accuracy of 0.3 mm for displacement up to 1 cm and 1°, and 0.5 mm for larger displacements. Different couch angles (45° and 90°) induced a mean vector uncertainty < 0.4 mm. Coverage of 1 camera produced an uncertainty < 0.5 mm. Translations and rotations of a phantom can be accurately detect with the optical surface detector system.

61 RADIATION PROTECTION AND DOSIMETRY↗

NASA Tech Briefs, May 2009

Topics covered include: Valve-"Health"-Monitoring System; Microstrip Antenna for Remote Sensing of Soil Moisture and Sea Surface Salinity; Biomedical Wireless Ambulatory Crew Monitor; Wireless Avionics Packet to Support Fault Tolerance for Flight Applications; Aerobot Autonomy Architecture; Submillimeter Confocal Imaging Active Module; Traveling-Wave Maser for 32 GHz; System Synchronizes Recordings from Separated Video Cameras; Piecewise-Planar Parabolic Reflectarray Antenna; Reducing Interference in ATC Voice Communication; EOS MLS Level 1B Data Processing, Version 2.2; Auto-Generated Semantic Processing Services; Geospatial Authentication; Maneuver Automation Software; Event Driven Messaging with Role-Based Subscriptions; Estimating Relative Positions of Outer-Space Structures; Fabricating PFPE Membranes for Capillary Electrophoresis; Linear Actuator Has Long Stroke and High Resolution; Installing a Test Tap on a Metal Battery Case; Fabricating PFPE Membranes for Microfluidic Valves and Pumps; Room-Temperature-Cured Copolymers for Lithium Battery Gel Electrolytes; Catalysts for Efficient Production of Carbon Nanotubes; Amorphous Silk Fibroin Membranes for Separation of CO2; "Zero-Mass" Noninvasive Pressure Transducers; Radial-Electric-Field Piezoelectric Diaphragm Pumps; Ejector-Enhanced, Pulsed, Pressure-Gain Combustor; Suppressing Ghost Diffraction in E-Beam-Written Gratings; Target-Tracking Camera for a Metrology System; Polarimetric Imaging using Two Photoelastic Modulators; Miniature Wide-Angle Lens for Small-Pixel Electronic Camera; Modal Filters for Infrared Interferometry; Mo(3)Sb(7-x)Te(x) for Thermoelectric Power Generation; Two-Dimensional Quantum Model of a Nanotransistor; Scanning Miniature Microscopes without Lenses; Manipulating Neutral Atoms in Chip-Based Magnetic Traps; Expansion Compression Contacts for Thermoelectric Legs; Processing Electromyographic Signals to Recognize Words; Physical Principle for Generation of Randomness; DSN Beowulf Cluster-Based VLBI Correlator; Hybrid NN/SVM Computational System for Optimizing Designs; Criteria for Modeling in LES of Multicomponent Fuel Flow; Computerized Machine for Cutting Space Shuttle Thermal Tiles; Orbiting Depot and Reusable Lander for Lunar Transportation; FPGA-Based Networked Phasemeter for a Heterodyne Interferometer; Aquarius Digital Processing Unit; Three-Dimensional Optical Coherence Tomography; Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes; Isolation of Precursor Cells from Waste Solid Fat Tissue; Identification of Bacteria and Determination of Biological Indicators; Further Development of Scaffolds for Regeneration of Nerves; Chemically Assisted Photocatalytic Oxidation System; Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications; Crashworthy Seats Would Afford Superior Protection; Open-Access, Low-Magnetic-Field MRI System for Lung Research; Microfluidic Mixing Technology for a Universal Health Sensor; Microfluidic Extraction of Biomarkers using Water as Solvent; Microwell Arrays for Studying Many Individual Cells; Droplet-Based Production of Liposomes; and Identifying and Inactivating Bacterial Spores

Source record↗

Neutron Scattering Investigation of the Relationship between Molecular Structure, Morphology and Dynamics in Conjugated Polymers

Conjugated polymers (CP) have enabled significant technological advances such as inexpensive organic solar cells (OPVs), biomedical sensor devices and flexible displays incorporating organic light emitting diodes (OLEDs) among others. Some of the distinguishing properties of CPs include simple processing from solutions, synthesis from abundant raw materials (C, H, S, N), flexible device form-factors and a capacity to fine-tune optical and electronic properties. Moreover, conductive polymers can assemble into large organized structures, such as nanowires and networks, that can significantly boost their performance. However, it is observed that small changes in the structure of the molecules (e.g. addition of alkyl groups) results in drastic and unpredictable changes in organized structures and electronic properties. This project utilized a comprehensive suite of elastic (SANS and USANS) and quasi-elastic (NSE and backscattering spectroscopy) neutron scattering techniques along with simultaneous property evaluation to unravel the relationships between molecular structure, self-assembly, directed-assembly and the resulting properties. Completed project objectives were: 1) to evaluate the influence of chain architecture on solution conformation, 2) to determine of the influence of molecular structure on CP self and directed assembly and 3) to study the correlation between dynamic molecular relaxations and macroscopic properties of CPs in the solid state. The experimental components of the project were further complemented by advanced molecular simulation strategies (e.g. atomistic MD and DFT) to fully understand the relationship between chain structure, mesoscale morphology, dynamic relaxation processes and the macroscopic properties.

36 MATERIALS SCIENCE↗

Tuning Optical Properties of Encapsulated Clusters of Gold Nanoparticles through Stimuli‐Triggered Controlled Aggregation

Abstract Gold nanoparticles entrapped in the hollow polymer nanocapsules undergo pH‐mediated controlled aggregation. Encapsulated clusters of nanoparticles show absorbance at higher wavelengths compared with individual nanoparticles. The size of the aggregates is controlled by the number of nanoparticles entrapped in individual nanocapsules. Such controlled aggregation may permit small biocompatible nanoparticles exhibit desirable properties for biomedical applications that are typically characteristic of large nanoparticles.

Dergunov, Sergey A.↗

Oriented gold nanorod arrays: self-assembly and optoelectronic applications

We present that self-assembly of anisotropic plasmonic nanomaterials into ordered superstructures has become popular in nanoscience because of their unique anisotropic optical and electronic properties. Gold nanorods (GNRs) are a well-defined functional building block for fabrication of these superstructures. They possess important anisotropic plasmonic characteristics that are resulted from strong local electric field and responsive to visible and near infrared light, which attracts extensive attention in various fields, such as biomedical technologies, plasmon-enhanced spectroscopies, and optoelectronic devices. There are recent examples of assembling the GNRs into ordered arrays or superstructures through processes such as solvent evaporation, interfacial assembly. In this review, we describe recent progresses in the development of the self-assembled GNR arrays with focus on the formation of oriented GNR arrays on substrates. We discuss key driving forces such as van der Waals (vdW), electrostatic interactions, steric force, and depletion force. We survey different strategies and self-assembly processes of forming oriented GNR arrays. Lastly, we also overview the applications of the oriented GNR arrays in optoelectronic devices especially surface enhanced Raman scattering (SERS). At the end of this review, we briefly summarize the review and discuss future challenges and perspectives.

36 MATERIALS SCIENCE↗

Sub-10 nm lanthanide doped BaLuF{sub 5} nanocrystals: Shape controllable synthesis, tunable multicolor emission and enhanced near-infrared upconversion luminescence

Highlights: • Sub-10 nm cubic phase BaLuF{sub 5} nanocrystals were synthesized by a hydrothermal method for the first time. • Tunable multicolor from yellow to yellow-green was achieved by controlling Gd{sup 3+} content in BaLuF{sub 5}:Yb/Er system. • Intense near-infrared upconversion luminescence in BaLuF{sub 5}:Gd/Yb/Tm nanocrystal. • The enhancement near-infrared luminescence can be realized by adjusting the content of Gd{sup 3+} in BaLuF{sub 5}:Gd/Yb/Tm system. - Abstract: In this study, sub-10 nm BaLuF{sub 5} nanocrystals with cubic phase structure were synthesized by a solvothermal method using oleic acid as the stabilizing agent. The as-prepared BaLuF{sub 5} nanocrystals were characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD), and analyzed by the upconversion (UC) spectra. The TEM results reveal that these samples present high uniformity. Compared with Gd-free samples, the size of BaLuF{sub 5}:Yb/Er doped with 10% Gd{sup 3+} decreased to 5.6 nm. In addition, BaLuF{sub 5}:Yb/Tm/Gd upconversion nanoparticles (UCNPs) presented efficient near-infrared (NIR)-NIR UC luminescence. Therefore, it is expected that these ultra-small BaLuF{sub 5} nanocrystals with well-controlled shape, size, and UC emission have potential applications in biomedical imaging fields.

36 MATERIALS SCIENCE↗

Laser technologies in biophotonics

This and the following issues of Quantum Electronics comprise articles reflecting the state of the art of laser technologies both currently applied and promising for application in biomedical research. Rapid development of biophotonics that we witness nowadays is due to a number of factors. These include the new results in basic studies of the interaction of laser radiation with biological tissues and cells, essential progress in the field of development of means for delivery, detection and imaging of optical radiation, and implementation of novel computer- and nanotechnologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-P-26: Study of Radiation Dose Evaluation for Organs at Risk Using MRI in Intensity Modulated Radiation Therapy for Nasopharyngeal Carcinoma

Purpose: To study the contour and dosimetric feature of organs at risk (OARs) applying magnetic resonance imaging (MRI) images in intensity modulated radiation therapy (IMRT) of nasopharyngeal carcinoma (NPC) compared to computed tomography (CT) images. Methods: 35 NPC patients was selected into this trail. CT simulation with non-contrast and contrast enhanced scan, MRI simulation with non-contrast and contrast enhanced T1, T2 and diffusion weighted imaging were achieved sequentially. And the OARs were contoured on the CT and MRI images after rigid registration respectively. 9 beams IMRT plan with equal division angle were designed for every patients, and the prescription dose for tumor target was set as 72Gy (2.4Gy/ fration). The boundary display, volume and dose-volume indices of each organ were compared between on MRI and CT images. Results: Compared to CT, MRI showed clearer boundary of brainstem, spinal cord, the deep lobe of Parotid gland and the optical nerve in canal. MRI images increase the volume of lens, optical nerve, while reducing the volume of eye slightly, and the maximum dose of lens, the mean dose of eyes and optical raised in different percentage, while there was no statistical differences were found. The left and right parotid volume on MRI increased by 7.07%, 8.13%, and the mean dose raised by 14.95% (4.01Gy), 18.76% (4.95Gy) with statistical significant difference (p<0.05). The brainstem volume reduced by 9.33% (p<0.05), and the dose of 0.1cm3 volume (D0.1cm3) reduced by mean 8.46% (4.32Gy), and D0.1cm3 of spinal cord increased by 1.5Gy on MRI. Conclusion: It is credible to evaluate the radiation dose of lens, eye and the spinal cord, while it should be necessary to evaluate the dose of brainstem, parotid and the optical nerve applying MRI images sometime, it will be more meaningful for these organs with high risk of radiation injury.

60 APPLIED LIFE SCIENCES↗

Exploration Laboratory Analysis

The Exploration Laboratory Analysis (ELA) project supports the Exploration Medical Capability (ExMC) risk to minimize or reduce the risk of adverse health outcomes and decrements in performance due to in-flight medical capabilities on human exploration missions. To mitigate this risk, the availability of inflight laboratory analysis instrumentation has been identified as an essential capability for manned exploration missions. Since a single, compact space-ready laboratory analysis capability to perform all exploration clinical measurements is not commercially available, the ELA project objective is to demonstrate the feasibility of emerging operational and analytical capability as a biomedical diagnostics precursor to long duration manned exploration missions. The initial step towards ground and flight demonstrations in fiscal year (FY) 2015 was the downselection of platform technologies for demonstrations in the space environment. The technologies selected included two Small Business Innovation Research (SBIR) performers: DNA Medicine Institute's rHEALTH X and Intelligent Optical System's lateral flow assays combined with Holomic's smartphone analyzer. The selection of these technologies were based on their compact size, breadth of analytical capability and favorable ability to process fluids in a space environment, among several factors. These two technologies will be advanced to meet ground and flight demonstration success criteria and requirements. The technology demonstrations and metrics for success will be finalized in FY16. Also, the downselected performers will continue the technology development phase towards meeting prototype deliverables in either late 2016 or 2017.

In-Flight laboratory↗

Volumetric cutaneous microangiography of human skin in vivo by VCSEL swept-source optical coherence tomography

We demonstrate volumetric cutaneous microangiography of the human skin in vivo that utilises 1.3-μm high-speed sweptsource optical coherence tomography (SS-OCT). The swept source is based on a micro-electro-mechanical (MEMS)-tunable vertical cavity surface emission laser (VCSEL) that is advantageous in terms of long coherence length over 50 mm and 100 nm spectral bandwidth, which enables the visualisation of microstructures within a few mm from the skin surface. We show that the skin microvasculature can be delineated in 3D SS-OCT images using ultrahigh-sensitive optical microangiography (UHS-OMAG) with a correlation mapping mask, providing a contrast enhanced blood perfusion map with capillary flow sensitivity. 3D microangiograms of a healthy human finger are shown with distinct cutaneous vessel architectures from different dermal layers and even within hypodermis. These findings suggest that the OCT microangiography could be a beneficial biomedical assay to assess cutaneous vascular functions in clinic. (laser biophotonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intracavity Laser Refractometry In Reflection: Development And Implementation In Biomedical Investigations

The Intracavity Laser Refractometry in Reflection (ILRR) method is developed for precise investigation of the processes on an interface of different media in real time. This method is very attractive for the study of biological liquids. It is based on the control of two-mode phase-anisotropic laser spectrum. In the aggregate the values of the sensitivity, time of measuring, potential parameters of investigated media of ILRR method correspond to the best results in optical refractometry. The absolute value of refractive index correlates with the course of different diseases. It can serve the objective parameter for an estimation of a level of illness processes in organism and drug efficiency. In result of the investigation of the photoresponse of the blood to low-level laser irradiation both the slow thermal effect and fast biophysical effect were discovered. The refractive index behaviour in real time allows the photoacceptors and maximum therapeutic doses on organism, cellular, and molecular levels to be determined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optical Imaging of Flow Pattern and Phantom

Time-resolved optical imaging technique has been used to image the spatial distribution of small droplets and jet sprays in a highly scattering environment. The snake and ballistic components of the transmitted pulse are less scattered, and contain direct information about the sample to facilitate image formation as opposed to the diffusive components which are due to multiple collisions as a light pulse propagates through a scattering medium. In a time-gated imaging scheme, these early-arriving, image-bearing components of the incident pulse are selected by opening a gate for an ultrashort period of time and a shadowgram image is detected. Using a single shot cooled CCD camera system, the formation of water droplets is monitored as a function of time. Picosecond time-gated image of drop in scattering cells, spray droplets as a function of let speed and gas pressure, and model calcification samples consisted of calcium carbonate particles of irregular shapes ranging in size from 0. 1 to 1.5 mm affixed to a microscope slide have been measured. Formation produced by an impinging jet will be further monitored using a CCD with 1 kHz framing illuminated with pulsed light. The desired image resolution of the fuel droplets is on the 20 pm scale using early light through a highly scattering medium. A 10(exp -6)m displacement from a jet spray with a flow speed of 100 m/sec introduced by the ns grating pulse used in the imaging is negligible. Early ballistic/snake light imaging offers nondestructive and noninvasive method to observe the spatial distribution of hidden objects inside a highly scattering environment for space, biomedical, and materials applications. In this paper, the techniques we will present are time-resolved K-F transillumination imaging and time-gated scattered light imaging. With a large dynamic range and high resolution, time-gated early light imaging has the potential for improving rocket/aircraft design by determining jets shape and particle sizes. Refinements to these techniques may enable drop size measurements in the highly scattering, optically dense region of multi-element rocket injectors. These types of measurements should greatly enhance the design of stable, and higher performing rocket engines.

Galland, Pierre A.↗

Optical CT imaging of solid radiochromic dosimeters in mismatched refractive index solutions using a scanning laser and large area detector

Purpose: The practical use of the PRESAGE® solid plastic dosimeter is limited by the inconvenience of immersing it in high-viscosity oils to achieve refractive index matching for optical computed tomography (CT) scanning. The oils are slow to mix and difficult to clean from surfaces, and the dosimeter rotation can generate dynamic Schlieren inhomogeneity patterns in the reference liquid, limiting the rotational and overall scan speed. Therefore, it would be beneficial if lower-viscosity, water-based solutions with slightly unmatched refractive index could be used instead. The purpose of this work is to demonstrate the feasibility of allowing mismatched conditions when using a scanning laser system with a large acceptance angle detector. A fiducial-based ray path measurement technique is combined with an iterative CT reconstruction algorithm to reconstruct images. Methods: A water based surrounding liquid with a low viscosity was selected for imaging PRESAGE® solid dosimeters. Liquid selection was optimized to achieve as high a refractive index as possible while avoiding rotation-induced Schlieren effects. This led to a refractive index mismatch of 6% between liquid and dosimeters. Optical CT scans were performed with a fan-beam scanning-laser optical CT system with a large area detector to capture most of the refracted rays. A fiducial marker placed on the wall of a cylindrical sample occludes a given light ray twice. With knowledge of the rotation angle and the radius of the cylindrical object, the actual internal path of each ray through the dosimeter can be calculated. Scans were performed with 1024 projections of 512 data samples each, and rays were rebinned to form 512 parallel-beam projections. Reconstructions were performed on a 512 × 512 grid using 100 iterations of the SIRT iterative CT algorithm. Proof of concept was demonstrated with a uniformly attenuating solution phantom. PRESAGE® dosimeters (11 cm diameter) were irradiated with Cobalt-60 irradiator to achieve either a uniform dose or a 2-level “step-dose” pattern. Results: With 6% refractive index mismatching, a circular field of view of 85% of the diameter of a cylindrical sample can be reconstructed accurately. Reconstructed images of the test solution phantom were uniform (within 3%) inside this radius. However, the dose responses of the PRESAGE® samples were not spatially uniform, with variations of at least 5% in sensitivity. The variation appears as a “cupping” artifact with less sensitivity in the middle than at the periphery of the PRESAGE® cylinder. Polarization effects were also detected for these samples. Conclusions: The fiducial-based ray path measurement scheme, coupled with an iterative reconstruction algorithm, enabled optical CT scanning of PRESAGE® dosimeters immersed in mismatched refractive index solutions. However, improvements to PRESAGE® dose response uniformity are required.

60 APPLIED LIFE SCIENCES↗