Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Anomalous single production of the fourth generation quarks at the CERN LHC

Possible anomalous single productions of the fourth standard model generation up and down type quarks at CERN Large Hadron Collider are studied. Namely, pp{yields}u{sub 4}(d{sub 4})X with subsequent u{sub 4}{yields}bW{sup +} process followed by the leptonic decay of the W boson and d{sub 4}{yields}b{gamma} (and its H.c.) decay channel are considered. Signatures of these processes and corresponding standard model backgrounds are discussed in detail. Discovery limits for the quark mass and achievable values of the anomalous coupling strength are determined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

T-odd correlations from CP violating anomalous top-quark couplings revisited

We revisit the effect of CP violating anomalous top-quark couplings in tt production and decay. We consider tt production through gluon fusion (and light qq annihilation) followed by top-quark decay into bW or bl{nu}. We find explicit analytic expressions for all the triple products generated by the anomalous couplings that fully incorporate all spin correlations. Our results serve as a starting point for numerical simulations for the CERN LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

tbW vertex in the littlest Higgs model with T parity

A study of the effective tbW vertex is done in the littlest Higgs model with T parity that includes the one-loop induced weak dipole coefficient f{sub 2R}. The top's width and the W-boson helicity in the t{yields}bW{sup +} decay as well as the t-channel and the s-channel modes of single top quark production at the LHC are then obtained for the tbW coupling. Our calculation is done in the Feynman-'t Hooft gauge, and we provide details of the analysis, like exact formulas (to all orders of the expansion variable v/f) of masses and mixing angles of all of the particles involved. Also, a complete and exact diagonalization (and normalization) of the scalar sector of the model is made.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Higgs boson flavor-changing neutral coupling and h{yields}t*c decay at a muon collider

We study the discovery potential of the flavor-changing neutral coupling (FCNC) htc of the Higgs boson and the top quark through the rare tree-body decay h{yields}Wbc at muon colliders for a light Higgs boson with mass 114{<=}m{sub h{<=}}145 GeV. This decay mode may compete with the standard model (SM) background induced by the hWW coupling in some models with a tree-level htc coupling and with models that predict this coupling at the one-loop level in the range 10{sup -2}-10{sup -1}. A future muon collider could test the scalar FCNC decay t{yields}hc via Higgs decay h{yields}t*c{yields}bW{sup +}c down to values of the coupling g{sub tc}=0.5[that are equivalent to BR(t{yields}hc){approx}5x10{sup -3}]. The LHC could probe values of g{sub tc} 1 order of magnitude smaller, unless other processes beyond the SM appear that through intense multijet activity may clutter the t{yields}hc signal.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dijet invariant mass distribution in top quark hadronic decay with QCD corrections

The dijet invariant mass distributions from the hadronic decay of unpolarized top quark (t{yields}bW{sup +} followed by W{sup +}{yields}ud) are calculated, including the next-to-leading order QCD radiative corrections. We treat the top decay in the complex mass scheme due to the existence of the intermediate state W boson. Our analytical expressions are also available in different dimensional regularization schemes and {gamma}{sub 5} strategies. Finally, in order to construct the jets, we use different jet algorithms to compare their influences on our results. The obtained dijet mass distributions from the top quark decay are useful to distinguish these dijets from those produced via other sources and to clarify the issue about the recent CDF Collaboration's Wjj anomaly.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Odd top partners at the LHC

LHC searches for fermionic top partners $T$ focus on three decay topologies: $T\to bW$, $T\to tZ$, and $T\to th$. However, top partners may carry new conserved quantum numbers that forbid these decays. The simplest possibility is a conserved parity, under which the top partner is odd and all SM states are even. In this case, decays of top partners may involve new particle-odd scalars, leading to signal topologies more commonly associated with supersymmetry, either with or without R-parity conservation. We study a simplified model in which this possibility is realized, and estimate the bounds on the top partner mass in this model implied by LHC searches for supersymmetry. We find that the bounds can be significantly weaker than in the conventional top partner decay scenario. For instance, if the new parity is exact, a 500 GeV top partner is allowed as long as the lightest parity-odd scalar mass is between 325 and 500 GeV. The lower allowed top partner mass reduces the need for fine-tuning in the Higgs mass parameter, compared to the conventional decay scenario. We also present an explicit model, the Oddest Little Higgs, which exhibits this phenomenology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Jet Mass Distribution and Top Quark Mass in Hadronic Decays of Boosted Top Quarks in $pp$ Collisions at $\sqrt{s} =$ TeV

A measurement is reported of the jet mass distribution in hadronic decays of boosted top quarks produced in pp collisions at s=13 TeV. The data were collected with the CMS detector at the LHC and correspond to an integrated luminosity of 35.9 fb-1. The measurement is performed in the lepton+jets channel of tt¯ events, where the lepton is an electron or muon. The products of the hadronic top quark decay t→bW→bqq¯′ are reconstructed as a single jet with transverse momentum larger than 400 GeV. The tt¯ cross section as a function of the jet mass is unfolded at the particle level and used to extract a value of the top quark mass of 172.6±2.5 GeV. A novel jet reconstruction technique is used for the first time at the LHC, which improves the precision by a factor of 3 relative to an earlier measurement. This highlights the potential of measurements using boosted top quarks, where the new technique will enable future precision measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise Measurement of the Top-Quark Mass in the Lepton+Jets Topology at CDF II

We present a measurement of the mass of the top quark from proton-antiproton collisions recorded at the CDF experiment in Run II of the Fermilab Tevatron. We analyze events from the single lepton plus jets final state (tt{yields}W{sup +}bW{sup -}b{yields}l{nu}bqq{sup '}b). The top-quark mass is extracted using a direct calculation of the probability density that each event corresponds to the tt final state. The probability is a function of both the mass of the top quark and the energy scale of the calorimeter jets, which is constrained in situ by the hadronic W boson mass. Using 167 events observed in 955 pb{sup -1} of integrated luminosity, we achieve the single most precise measurement of the top-quark mass, 170.8{+-}2.2(stat.){+-}1.4(syst.) GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lipid droplet-associated proteins in alcohol-associated fatty liver disease: A proteomic approach

The earliest manifestation of alcohol-associated liver disease (ALD) is steatosis characterized by deposition of fat in specialized organelles called lipid droplets (LDs). While alcohol administration causes a rise in LD numbers in the hepatocytes, little is known regarding their characteristics that allow their accumulation and size to increase. The aim of the present study is to gain insights into underlying pathophysiological mechanisms by investigating the ethanol-induced changes in hepatic LD proteome as a function of LD size. Adult male Wistar rats (180–200 g BW) were fed with ethanol liquid diet for 6 weeks. At sacrifice, large-, medium-, and small-sized hepatic LD subpopulations (LD1, LD2, and LD3, respectively) were isolated and subjected to morphological and proteomic analyses. Morphological analysis of LD1-LD3 fractions of ethanol-fed rats clearly demonstrated that LD1 contained larger LDs compared with LD2 and LD3 fractions. Our preliminary results from principal component analysis showed that the proteome of different-sized hepatic LD fractions was distinctly different. Proteomic data analysis identified over 2000 proteins in each LD fraction with significant alterations in protein abundance among the three LD fractions. Among the altered proteins, several were related to fat metabolism, including synthesis, incorporation of fatty acid, and lipolysis. Ingenuity pathway analysis revealed increased fatty acid synthesis, fatty acid incorporation, LD fusion, and reduced lipolysis in LD1 compared to LD3. Overall, the proteomic findings indicate that the increased level of protein that facilitates fusion of LDs combined with an increased association of negative regulators of lipolysis dictates the generation of large-sized LDs during the development of alcohol-associated hepatic steatosis. Several significantly altered proteins were identified in different-sized LDs isolated from livers of ethanol-fed rats. Ethanol-induced increases in specific proteins that hinder LD lipid metabolism led to the accumulation and persistence of large-sized LDs in the liver.

60 APPLIED LIFE SCIENCES↗

SU-D-18C-06: Initial Experience with Implementing MRI Safety Guidelines for Patients with Pacemakers - Medical Physicist Perspective

Purpose: Several institutions have developed MRI guidelines for patients with MR-unsafe or MR-conditional pacemakers. Here we highlight the role of a medical physicist in implementing these guidelines for non-pacemaker dependent patients. Guidelines: Implementing these guidelines requires involvement from several medical specialties and a strong collaboration with the site MRI supervisor to develop a structured workflow. A medical physicist is required to be present during the scan to supervise the MR scanning and to maintain a safety checklist that ensures: 1) uninterrupted patient communication with the technologist, 2) continuous patient physiologic monitoring (e.g. blood pressure and electrocardiography) by a trained nurse, 3) redundant patient vitals monitoring (e.g. pulse oximetry) due to the possibility of in vivo electrocardiography reading fluctuations during image acquisition. A radiologist is strongly recommended to be available to review the images before patients are discharged from the scanner. Pacemaker MRI should be restricted to 1.5T field strength. The MRI sequences should be optimized by the physicist with regards to: a) SAR: limited to <1.5 W/Kg for MR-unsafe pacemakers in normal operating mode, b) RF exposure time: <30 min, c) Coils: use T/R coils but not restricted to such, d) Artifacts: further optimization of sequences whenever image quality is compromised due to the pacemaker. In particular, cardiac, breast and left-shoulder MRIs are most susceptible to these artifacts. Possible strategies to lower the SAR include: a) BW reduction, 2) echo-train-length reduction, 3) increase TR, 4) decrease number of averages, 5) decrease flip angle, 6) reduce slices and/or a combination of all the options. Conclusion: A medical physicist in collaboration with the MR supervisor plays an important role in the supervision/implementation of safe MR scanning of pacemaker patients. Developing and establishing a workflow has enabled our institution to scan over 30 patients with pacemakers without complications, including 3 cardiac MR exams.

60 APPLIED LIFE SCIENCES↗

SU-E-T-274: Radiation Therapy with Very High-Energy Electron (VHEE) Beams in the Presence of Metal Implants

Purpose: To evaluate the effect of metal implants on treatment plans for radiation therapy with very high-energy electron (VHEE) beams. Methods: The DOSXYZnrc/BEAMnrc Monte Carlo (MC) codes were used to simulate 50–150MeV VHEE beam dose deposition and its effects on steel and titanium (Ti) heterogeneities in a water phantom. Heterogeneities of thicknesses ranging from 0.5cm to 2cm were placed at 10cm depth. MC was also used to calculate electron and photon spectra generated by the VHEE beams' interaction with metal heterogeneities. The original VMAT patient dose calculation was planned in Eclipse. Patient dose calculations with MC-generated beamlets were planned using a Matlab GUI and research version of RayStation. VHEE MC treatment planning was performed on water-only geometry and water with segmented prostheses (steel and Ti) geometries with 100MeV and 150MeV beams. Results: 100MeV PDD 5cm behind steel/Ti heterogeneity was 51% less than in the water-only phantom. For some cases, dose enhancement lateral to the borders of the phantom increased the dose by up to 22% in steel and 18% in Ti heterogeneities. The dose immediately behind steel heterogeneity decreased by an average of 6%, although for 150MeV, the steel heterogeneity created a 23% increase in dose directly behind it. The average dose immediately behind Ti heterogeneities increased 10%. The prostate VHEE plans resulted in mean dose decrease to the bowel (20%), bladder (7%), and the urethra (5%) compared to the 15MV VMAT plan. The average dose to the body with prosthetic implants was 5% higher than to the body without implants. Conclusion: Based on MC simulations, metallic implants introduce dose perturbations to VHEE beams from lateral scatter and backscatter. However, when performing clinical planning on a prostate case, the use of multiple beams and inverse planning still produces VHEE plans that are dosimetrically superior to photon VMAT plans. BW Loo and P Maxim received research support from RaySearch laboratories; B Hardemark and E Hynning are employees of RaySearch.

60 APPLIED LIFE SCIENCES↗

SU-E-T-496: A Study of Two Commercial Dose Calculation Algorithms in Low Density Phantom

Purpose: Some lung cancer patients have very low lung density due to comorbidities. We investigate calculation accuracy of Eclipse AAA and Acuros(AXB) using a phantom that simulates this situation. Methods: A 2.5 x 5.0 x 5 cm (long) solid water inhomogeneity positioned 10 cm deep in a Balsa lung phantom (density 0.099 gm/cc) was irradiated with an off-center field such that the central axis was parallel to one side of the inhomogeneity. Radiochromic films were placed at 2.5cm(S1) and 5cm(S2) depths. After CT scanning, Hounsfield Units(HU) were converted to electron(ρe) and mass(ρm) density using in-house(IH) and vendor-supplied(V) calibration curves. IH electron densities were generated using a commercial electron density phantom. The phantom was exposed to 6 MV 3x3 and 20x20 fields. Dose distributions were calculated using the AAA and AXB algorithms. Results: The HU of BW is -910±40 which translates to ρe of 0.088±0.050(IH) and 0.090±0.050(V), and ρm of 0.101±0.045(IH) and 0.103±0.039(V). Both ρe(V) and ρm(V) are higher than ρe(IH) and ρm(IH) respectively by 1.4-5.3% and 0.5-12.3%. The average calculated dose inside the solid water ‘tumor’ are within 3.7% and 2.4% of measurements for both calibrations and field sizes using AAA and AXB. Within 10mm outside the ‘tumor’, AAA on average underestimates by 18.3% and 17.0% respectively for 3x3 using IH and V. AXB underestimates by 5.9%(S1)-6.6%(S2) and 13.1%(S1)-16.0%(S2) respectively using IH and V. For 20x20, AAA and AXB underestimate by 2.8%(S1)-4.4%(S2) and 0.3%(S1)-1.4%(S2) respectively with either calibration. Conclusion: The difference in the HU calibration between V and IH is not of clinical significance in normal field sizes. In the low density region of small fields, the calculations from both algorithms differ significantly from measurements. This may be attributed to the insufficient lateral electron transport modeled by two algorithms resulting in the over-estimation in penumbra expansion.

60 APPLIED LIFE SCIENCES↗

MO-H-19A-01: FEATURED PRESENTATION - Treatment Planning Tool for Radiotherapy with Very High-Energy Electron Beams

Purpose: To develop a tool for treatment planning optimization for fast radiotherapy delivered with very high-energy electron beams (VHEE) and to compare VHEE plans to state-of-the-art plans for challenging pelvis and H'N cases. Methods: Treatment planning for radiotherapy delivered with VHEE scanning pencil beams was performed by integrating EGSnrc Monte Carlo (MC) dose calculations with spot scanning optimization run in a research version of RayStation. A Matlab GUI for MC beamlet generation was developed, in which treatment parameters such as the pencil beam size and spacing, energy and number of beams can be selected. Treatment planning study for H'N and pelvis cases was performed and the effect of treatment parameters on the delivered dose distributions was evaluated and compared to the clinical treatment plans. The pelvis case with a 691cm3 PTV was treated with 2-arc 15MV VMAT and the H'N case with four PTVs with total volume of 531cm3 was treated with 4-arc 6MV VMAT. Results: Most studied VHEE plans outperformed VMAT plans. The best pelvis 80MeV VHEE plan with 25 beams resulted in 12% body dose sparing and 8% sparing to the bowel and right femur compared to the VMAT plan. The 100MeV plan was superior to the 150MeV plan. Mixing 100 and 150MeV improved dose sparing to the bladder by 7% compared to either plan. Plans with 16 and 36 beams did not significantly affect the dose distributions compared to 25 beam plans. The best H'N 100MeV VHEE plan decreased mean doses to the brainstem, chiasm, and both globes by 10-42% compared to the VMAT plan. Conclusion: The pelvis and H'N cases suggested that sixteen 100MeV beams might be sufficient specifications of a novel VHEE treatment machine. However, optimum machine parameters will be determined with the presented VHEE treatment-planning tool for a large number of clinical cases. BW Loo and P Maxim received research support from RaySearch Laboratories. E Hynning and B Hardemark are employees of RaySearch Laboratories.

60 APPLIED LIFE SCIENCES↗

Adaptation of the modified Bouc–Wen model to compensate for hysteresis in respiratory motion for the list-mode binning of cardiac SPECT and PET acquisitions: Testing using MRI

Purpose: Binning list-mode acquisitions as a function of a surrogate signal related to respiration has been employed to reduce the impact of respiratory motion on image quality in cardiac emission tomography (SPECT and PET). Inherent in amplitude binning is the assumption that there is a monotonic relationship between the amplitude of the surrogate signal and respiratory motion of the heart. This assumption is not valid in the presence of hysteresis when heart motion exhibits a different relationship with the surrogate during inspiration and expiration. The purpose of this study was to investigate the novel approach of using the Bouc–Wen (BW) model to provide a signal accounting for hysteresis when binning list-mode data with the goal of thereby improving motion correction. The study is based on the authors’ previous observations that hysteresis between chest and abdomen markers was indicative of hysteresis between abdomen markers and the internal motion of the heart. Methods: In 19 healthy volunteers, they determined the internal motion of the heart and diaphragm in the superior–inferior direction during free breathing using MRI navigators. A visual tracking system (VTS) synchronized with MRI acquisition tracked the anterior–posterior motions of external markers placed on the chest and abdomen. These data were employed to develop and test the Bouc–Wen model by inputting the VTS derived chest and abdomen motions into it and using the resulting output signals as surrogates for cardiac motion. The data of the volunteers were divided into training and testing sets. The training set was used to obtain initial values for the model parameters for all of the volunteers in the set, and for set members based on whether they were or were not classified as exhibiting hysteresis using a metric derived from the markers. These initial parameters were then employed with the testing set to estimate output signals. Pearson’s linear correlation coefficient between the abdomen, chest, average of chest and abdomen markers, and Bouc–Wen derived signals versus the true internal motion of the heart from MRI was used to judge the signals match to the heart motion. Results: The results show that the Bouc–Wen model generated signals demonstrated strong correlation with the heart motion. This correlation was slightly larger on average than that of the external surrogate signals derived from the abdomen marker, and average of the abdomen and chest markers, but was not statistically significantly different from them. Conclusions: The results suggest that the proposed model has the potential to be a unified framework for modeling hysteresis in respiratory motion in cardiac perfusion studies and beyond.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗