Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BRASS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Electrodeposited Zinc-based Films as Anodes for Aqueous Zinc Batteries

Zinc-based batteries have attracted extensive attention in recent years, due to high safety, high capacities, environmental friendliness, and low cost compared to lithium ion batteries. However, the zinc anode suffers primarily from dendrite formation as a mode of failure in the mildly acidic system. Herein, we report on electrochemically deposited zinc (ED Zn) and copper-zinc (brass) alloy anodes, which are critically compared with a standard commercial zinc foil. The film electrodes are of commercially relevant thicknesses (21 and 25µM). The electrodeposited zinc-based anodes exhibit low electrode polarization (~0.025V) and stable cycling performance in 50 cycle consecutive experiments from 0.26-10 mA cm-2 compared to commercial Zn foil. Coulombic efficiencies at 1 mA cm-2 were over 98% for the electrodeposited zinc-based materials and were maintained for over 100 cycles. Furthermore, full cells with an electrodeposited Zn/brass anode, EMD MnO2 cathode, in 1M ZnSO4 + 0.1M MnSO4 delivered capacities of 96.3, and 163 mAh g-1, respectively, at a 100 mA g-1 compared to 92.1 mAh g-1 for commercial Zn. The zinc-based anodes also show better rate capability, delivering full cell capacities of 35.9 and 47.5 mAh g-1 at high current of up to 3 A g-1. Lastly, the electrodeposited zinc-based anodes show enhanced capacity for up to 100 cycles at 100 mA g-1, making them viable anodes for commercial use.

Fayette, Matthew R.↗

Texture evolution during processing and post-processing of maraging steel fabricated by laser powder bed fusion

Abstract In this study, the evolution of solidification texture during LPBF of Ti-free grade 300 maraging steel, and its effect on texture development during subsequent post-fabrication heat treatments was characterized using Electron Backscatter Diffraction (EBSD). It was found that in the as-fabricated state, no texture was observed in the room temperature martensitic phase. However, the reconstructed parent austenite phase displayed a Cube texture with a minor fraction of Rotated Goss texture. During subsequent aging treatments involving two different routes, namely direct aging of the as-fabricated samples, and conventional solution treatment + aging of the as-fabricated samples, significant changes in the texture components of parent austenite were observed, whereas no changes in texture were observed in the room temperature martensitic phase. During direct aging, it was found that with an increase in the aging temperature up to 520 °C, the texture components of the parent austenite changed from Cube/Rotated Goss to Brass, whereas during the conventional solution treatment and aging cycle, interestingly a change in texture component to rotated copper was observed. The transitions in texture components have been discussed using the concepts of recrystallization and twinning in austenite during annealing and/or aging, and strain energy release maximization (SERM) theory. Furthermore, the importance of these preferred orientations on the mechanical properties was quantified using transformation potential diagrams.

36 MATERIALS SCIENCE↗

Optimizing photovoltaic performance in CuInS 2 and CdS quantum dot-sensitized solar cells by using an agar-based gel polymer electrolyte

Quantum dot-sensitized solar cells (QDSSCs) offer new opportunities to address the clean energy challenge, being one of the top candidates for third generation photovoltaics. Like dye-sensitized solar cells (DSSCs), QDSSCs normally use liquid electrolytes that suffer from issues such as evaporation or leakage. In this study a gel polysulfide electrolyte was prepared containing a natural polymer, agar, and was used as a quasi-solid-state electrolyte in solar cells to replace the conventional liquid electrolytes. This gel electrolyte shows almost the same conductivity as the liquid one. The solar cells were fabricated using CuInS 2 quantum dots (QDs), previously synthesized, deposited on TiO 2 photoanodes by electrophoretic deposition (EPD). CdS was deposited on TiO 2 by successive ionic layer adsorption and reaction (SILAR). Reduced graphene oxide (RGO)–Cu 2 S, brass, and thin film CuxS were used as counter electrodes. Compared to a liquid polysulfide water based electrolyte, solar cells based on CuInS 2 and CdS using gel polymer electrolyte (GPE) exhibit greater incident photon to current conversion efficiency (IPCE = 51.7% at 520 nm and 72.7% at 440 nm), photocurrent density (J sc = 10.75 and 13.51 mA cm -2 ), and power conversion efficiency (η = 2.97 and 2.98%) while exhibiting significantly enhanced stability. The solar cells employing the agar-based gel polymeric electrolyte are about a factor of 0.20 more stable than using a liquid electrolyte. The higher photovoltaic performance is due to the good conductivity and high wettability as well as the superior permeation capability of the gel electrolyte into the mesoporous matrix of a TiO 2 film

14 SOLAR ENERGY↗

Studying Radiation from Z-pinch Wire Array and X-Pinch Plasmas: K-shell Mg to M-shell Mo

University-scale Z-pinch generators are able to produce plasmas with a broad range of temperatures, densities, and opacity properties depending on the type, size, and mass of wire-array loads and wire materials. Experiments with very different Z-pinch loads were performed on the 1 MA Zebra generator at UNR and analyzed during the last five years including Single and Nested Cylindrical, Conical, and various types of Planar Wire Arrays. It is shown that such wire arrays are good sources of x-rays and that they produce significant radiation yield (up to 25 kJ) on a ns time scale, and generate bright spots of sub-mm size. They can be used for studying radiative properties of moderate density (between 10{sup 18} cm{sup -3} and 5x10{sup 21} cm{sup -3}) and temperature (<=1.5 keV) plasmas. In addition, X-pinches generated higher density (>10{sup 22} cm{sup -3}) and temperature (>2 keV) plasmas on scales as small as a few mum to several mm in size. Wire materials with a broad range of nuclear charge Z were used, ranging from low-Z, such as alloyed Al wires with varying concentrations of Mg, to mid-Z, such as Stainless steel, Cu, Brass, and Mo. Uniform (made from one wire material) as well as combined (made from two wire materials with almost equal wire masses) wire arrays were considered. Uniform, combined, symmetric and asymmetric X-pinches (some of which included a small fraction of tracer Al wires) were also considered. Non-LTE kinetic models to account for K- and L-shell radiation were employed to understand radiative properties of Z-pinch and X-pinch plasmas. Implosion characteristics of such loads are discussed using the wire dynamics and MHD models. Opacity effects of Z-pinch plasmas are studied and benefits of using alloyed and tracer wires are highlighted.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detection of THz radiation with devices made from wafers with HgTe and InSb quantum wells

In this study we present measurements of the Terahertz (THz) photoconductivity of 2D electron system realized at HgTe/HgCdTe and AlInSb/InSb/AlInSb quantum wells (QWs) in Corbino geometry (inner and outer radius: 500 {mu}m and 1500 {mu}m) with different mobilities and electron densities. To characterize the devices, the Shubnikov-de Haas (SdH) effect up to magnetic fields B of 7T and current-voltage (I-V) characteristics at various magnetic fields were measured. The THz radiation is provided by a p-Ge laser which operates with a magnetic field and a high voltage for the electrical pumping. The stimulated emission is caused by transitions between Landau levels of light holes [1]. The laser is tunable in the range between 1.7 to 2.5 THz (corresponding to wavelengths between 120 to 180 {mu}m or energies of 7 to 12 meV). The laser is pulsed with a pulse rate of 1 Hz and pulse lengths of about 1 {mu}s with low switching times (about 20 ns). The monochromatic THz radiation is transferred to our samples via a 0.32m long brass waveguide immersed in liquid Helium. The detection of a change in the conductivity of the sample due to absorption of THz-radiation (photoresponse) requires a low-noise circuit. For the Corbino-shaped samples the photoresponse (PR) is measured via a resistor R{sub V} of 1 k{Omega}. The signal is transferred via in a high-frequency cable and detected with a digital oscilloscope.

36 MATERIALS SCIENCE↗

Resonant excitation of coupled Rayleigh waves in a short and narrow fluid channel clad between two identical metal plates

Transmission of ultrasonic waves through a slit between two water immersed brass plates is studied for sub-wavelength plate thicknesses and slit apertures. Extraordinary high absorption is observed at discrete frequencies corresponding to resonant excitation of Rayleigh waves on the both sides of the channel. The coupling of the Rayleigh waves occurs through the fluid and the corresponding contribution to the dispersion has been theoretically derived and also experimentally confirmed. Symmetric and anti-symmetric modes are predicted but only the symmetric mode resonances have been observed. It follows from the dispersion equation that the coupled Rayleigh waves cannot be excited in a channel with apertures less than the critical one. The calculated critical aperture is in a good agreement with the measured acoustic spectra. These findings could be applied to design a broadband absorptive metamaterial.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrated testing of the Thales LPT9510 pulse tube cooler and the iris LCCE electronics

The Jet Propulsion Laboratory (JPL) has identified the Thales LPT9510 pulse tube cryocooler as a candidate low cost cryocooler to provide active cooling on future cost-capped scientific missions. The commercially available cooler can provide refrigeration in excess of 2 W at 100K for 60W of power. JPL purchased the LPT9510 cooler for thermal and dynamic performance characterization, and has initiated the flight qualification of the existing cooler design to satisfy near-term JPL needs for this cooler. The LPT9510 has been thermally tested over the heat reject temperature range of 0C to +40C during characterization testing. The cooler was placed on a force dynamometer to measure the selfgenerated vibration of the cooler. Iris Technology has provided JPL with a brass board version of the Low Cost Cryocooler Electronics (LCCE) to drive the Thales cooler during characterization testing. The LCCE provides precision closed-loop temperature control and embodies extensive protection circuitry for handling and operational robustness; other features such as exported vibration mitigation and low frequency input current filtering are envisioned as options that future flight versions may or may not include based upon the mission requirements. JPL has also chosen to partner with Iris Technology for the development of electronics suitable for future flight applications. Iris Technology is building a set of radiation-hard, flight-design electronics to deliver to the Air Force Research Laboratory (AFRL). Test results of the thermal, dynamic and EMC testing of the integrated Thales LPT9510 cooler and Iris LCCE electronics is presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Expansion dynamics of ultrafast laser produced plasmas in the presence of ambient argon

In this paper, we report the emission features of fs laser ablated brass plasma plumes at various Ar background pressure levels ranging from vacuum to atmospheric conditions. Spectrally integrated 2D-imaging of plasma self-emission showed several interesting features at various pressure levels which consists of plume morphological changes, increase in persistence, confinement, and internal structures. Spatially resolved wavelength dispersed images of the plume were recorded for characterizing the spectral features at various pressure levels and also used for obtaining spatial distribution of Cu I and Zn I species in the plume, signal to noise ratios and fundamental parameters of the plasma; viz. temperature and density. The spatial evolution of excitation temperature and density showed significant changes at various ambient pressure levels and these results were correlated to morphological changes seen in the plume images. Optimum signal to background ratios for emission lines were observed in the moderate pressure range (~ 1-10 Torr). Optical time-of-flight profiles were used to study time evolution of various species in the plume and noticed oscillations at intermediate pressure levels. Possible mechanisms for observed changes in plume shape, optical emission intensity, and dual peak structures in time-of-flight profiles were discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of ultrafast laser-ablation plasma plumes at various Ar ambient pressures

Expansion dynamics and internal plume structures of fs laser ablated brass plasma in Ar at various pressure levels ranging from vacuum to atmospheric were studied using multitude of diagnostic tools including time resolved and time integrated 2-dimensional imaging, optical time of flight measurements and visible emission spectroscopy. Temporal evolution of excited Cu and Zn species in the plume were imaged using band pass interference filters and compared its hydrodynamic expansion features with spectrally integrated images of the plume. 2D imaging coupled with monochromatic line selection showed several interesting features at various pressure levels which include velocity differences among the plume species, emission intensity distribution, plasma temperature, electron density etc. Plume confinement, enhanced signal intensity, and dual peak structures in time-of-flight profiles were observed at intermediate pressure range of ~10 Torr. Optimum signal to background ratio was also observed in this pressure range. As a result, possible mechanisms for observed changes in plume shape, optical emission intensity and dual peak structures in time-of-flight profiles were discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using a time lapse microgravity model for mapping seawater intrusion around Semarang

A modeling of time-lapse microgravity anomaly due to sea water intrusion has been conducted. It used field data of aquifer cross section, aquifer thickness and lithology of research area. Those data were then processed using Grav3D and Surfer. Modeling results indicated that the intrusion of sea water resulting in a time-lapse microgravity anomalies of 0.12 to 0.18 mGal, at soil layer density of 0.15 g/cm{sup 3} to 0.3 g/cm{sup 3} and at depth of 30 to 100 m. These imply that the areas experiencing seawater intrusion were Tanjung Mas, SPBE Bandarharjo, Brass, Old Market Boom and Johar as the microgravity measured there were in the range of 0.12 to 0.18 mGal and the density contrast were at 0.15 g/cm{sup 3} to 0.28 g/cm{sup 3}. Areas that experienced fluid reduction were Puri Anjasmoro, Kenconowungu and Puspowarno with microgravity changes from -0.06 mGal to -0.18 mGal.

54 ENVIRONMENTAL SCIENCES↗

Aqueous density fractionation of nanocarbons from colliding-wave PBX9502 detonation soot

The study of solid carbon (nanocarbon) nucleation and growth from detonating high explosives is limited because of the difficulty directly evaluating chemical reactions behind the shock front. Understanding the correlation between detonation conditions and nanocarbon formation requires isolation, purification, and analysis of the carbon products. Aqueous density fractionation of products recovered from a colliding wave TATB-based high explosive (PBX9502) detonation are evaluated as an environmentally benign, “green” chemical processing approach for the separation of carbon materials from metal and metal oxide byproducts. Recovery of material sufficient for X-ray scattering analysis was obtained in two fractions. X-ray scattering showed the less dense fraction (ρ < 1 g/cm 3 ) contains hollow spherical core (d avg = 27.8 nm) nanoparticles with a shell (thickness=3.6 nm) composed of predominately sp 2 hybridized carbon. Particles contained within the dense fraction (ρ > 1 g/cm 3 ) were a mixture of oblate spheroids (major axis length=43.8 nm and minor axis=2.9 nm) and small polydisperse solid spherical particles (d avg = 2.4 nm) composed of both sp 2 and sp 3 bonded carbon with residual contamination from the brass detonators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental and Numerical Evaluation of the Thermal-Fluid Characteristics of the Helium-Cooled Modular Divertor with Multiple Jets Using a Reversed Heat Flux Approach

A single-finger unit of the Helium-Cooled Modular Divertor with Multiple Jets (HEMJ) with a plasma-facing surface (PFS) area of about 2 cm 2 has been studied in a helium (He) loop at He mass flow rates m˙ H ≤ 8 g/s and nearly prototypical conditions. Based on previous studies of the single finger of the HEMJ, our Georgia Institute of Technology group is planning to experimentally study larger divertors. Given that the HEMJ test section was heated with an induction heater and that it is impractical to scale this up to divertors with larger PFS areas, a reversed heat flux approach is being considered to measure heat transfer coefficients (HTCs). In this approach, the direction of the heat flux is reversed with water cooling and high-temperature He heating of the outer shell attached to the PFS. This work presents an initial experimental and numerical evaluation of this approach for a single HEMJ finger. Experiments with brass and copper-chromium-zirconium outer shells were conducted at dimensionless He mass flow rates or Reynolds numbers Re = 1 × 10 4 to 4.7 × 10 4 , an inlet pressure of 10 MPa, temperatures as great as 673 K, and maximum heat flux of 8.4 MW/m 2 . The experiments verify that the He-side HTCs are independent of the direction of the heat flux. Here, the results agree well with previous Nusselt number correlation and pressure loss coefficients for the HEMJ obtained using the normal heating approach.

42 ENGINEERING↗

Development of a predictive capability of short-pulse laser-driven broadband x-ray radiography

High intensity, short-pulse laser interaction with a solid metal target produces broadband hard x-rays potentially for various applications of x-ray radiography. In this work, experimental benchmarking of numerical modelling for short-pulse laser-driven broadband x-ray radiography is presented. Angular dependent x-ray spectra are first calculated with a hybrid particle-in-cell code, Large Scale Plasma (LSP), using fast electron parameters inferred from an analysis of measured bremsstrahlung signals. Subsequently, a calculated x-ray spectrum in the direction of radiography is used in photon transport calculations using a Monte Carlo code, Particle and Heavy Ion Transport code System (PHITS), to simulate a radiographic image including a modelled 3D test object, an x-ray attenuation filter and an image plate detector. Simulated radiographic images are compared with measurements obtained in an experiment using a 50-TW Leopard short-pulse laser at the University of Nevada Reno. Results show that simulations reproduce the experimental images well for three different attenuation filters (plastic, aluminium, and brass), while 1D transmission profiles for the plastic and aluminium filters are quantitatively in good agreement. The modelling approach established in this work could be used as a predictive tool to simulate radiographic images of complex 3D solid objects at any arbitrary angular position or to optimize experimental components such as the source spectrum, x-ray attenuation filters and a detector type depending on a radiographic object without carrying out radiographic experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of the CMS hadron calorimeters using proton-proton collision data at √ s = 13 TeV

Methods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities |η| < 3 and are positioned inside the solenoidal magnet. An outer calorimeter, outside the magnet coil, covers |η| < 1.26, and a steel and quartz-fiber Cherenkov forward calorimeter extends the coverage to |η| < 5.19. The initial calibration of the calorimeters was based on results from test beams, augmented with the use of radioactive sources and lasers. The calibration was improved substantially using proton-proton collision data collected at √ s = 7 , 8, and 13 TeV, as well as cosmic ray muon data collected during the periods when the LHC beams were not present. The present calibration is performed using the 13 TeV data collected during 2016 corresponding to an integrated luminosity of 35.9 fb -1 . The intercalibration of channels exploits the approximate uniformity of energy collection over the azimuthal angle. The absolute energy scale of the central and endcap calorimeters is set using isolated charged hadrons. The energy scale for the electromagnetic portion of the forward calorimeters is set using Z→ ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CMS experiment at the CERN LHC

The Compact Muon Solenoid (CMS) detector is described. The detector operates at the Large Hadron Collider (LHC) at CERN. It was conceived to study proton-proton (and lead-lead) collisions at a centre-of-mass energy of 14 TeV (5.5 TeV nucleon-nucleon) and at luminosities up to $10^{34} cm^{-2} s^{-1} (10^{27}cm^{-2} s^{-1})$. At the core of the CMS detector sits a high-magnetic-field and large-bore superconducting solenoid surrounding an all-silicon pixel and strip tracker, a lead-tungstate scintillating-crystals electromagnetic calorimeter, and a brass-scintillator sampling hadron calorimeter. The iron yoke of the flux-return is instrumented with four stations of muon detectors covering most of the $4\pi$ solid angle. Forward sampling calorimeters extend the pseudorapidity coverage to high values ($|\eta|$ <= 5) assuring very good hermeticity. The overall dimensions of the CMS detector are a length of 21.6 m, a diameter of 14.6 m and a total weight of 12500 t.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An 18 Element Strip of 1 mm$^{2}$ G-APDs for CMS HCAL upgrade results of CERN Test Beam 2009

The Compact Muon Solenoid hadronic barrel (CMS HB) calorimeter consists of 17 layers of scintillator in a brass absorber. Each scintillator consists of 16 tiles comprising one layer of the corresponding towers in pseudo-rapidity. The light from each tile is routed into a single 0.96 mm wavelength shifting fiber. In the current design, the 17 fibers from the full tower depth are directed into one pixel of a multi-channel hybrid photo-diode (HPD). Thus, no longitudinal shower information is readout. In the last year we have developed 18 element MAPD arrays (Micro-pixel Avalanche Photo Diodes) on 8 inch wafers with Zecotek in Singapore. A special prototype 20 pin ceramic package was made by Kyocera in Germany. By using 18 element G-APD strips (Geiger mode Avalanche photo diodes) we could readout each layer separately, so that 17 of these strips replace one HPD. Because of the large linear range requirement in the hadronic calorimeter and radiation hardness needed, we used the new generation high cell density Zecotek MAPDs with 15,000 cells per strip element. Due to the higher PDE (photon detection efficiency) versus the HPD (30% vs. 12%) we got 5 p.e. per layer for a MIP. Due to limited availability of electronic channels for these tests, analog signals from multiple strips were added together providing digital readout from four depth segments. Non uniformity between strips was calibrated using muons and measurements of breakdown voltage of each element of the array. After calibration of the 4 longitudinal depth segments, the linearity and detector resolution was studied using pions with energies from 30 to 300 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of MARCO, the New Solenoidal Detector Magnet for the ePIC Experiment at BNL

MARCO is the new superconducting solenoid for ePIC, the general-purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider at Brookhaven National Laboratory. Here, this 3.84 m long solenoid, with a bore diameter of 2.84 m, will provide a magnetic field of 2.0 T at the center with a nominal current of 4 kA at 4.5 K, for a total stored energy of 45 MJ. Its conductor is a NbTi Rutherford in Copper Channel (RICC), specially designed to stand the high mechanical loads induced by the magnetic field. Its copper stabilizer will assure the protection in case of quench. The coils are wound into six layers inside a thin external mandrel in brass, with a triple role of mechanical reinforcement, cryogenic support for the thermosiphon circuit and quench-back propagator. With a cold mass average radial thickness of just 7 cm, the magnet fulfills all the criterions of transparency for the particles directed to the hadronic calorimeter forecast around the cryostat. In this paper, the design of MARCO is presented, with a specific focus on the magnetic and quench analysis.

Calvelli, Valerio [Commissariat a l'Energie Atomiq↗

Mechanical Design of the MARCO Solenoid Detector Magnet

MARCO is the superconducting solenoid for ePIC, the new particle physics detector of the upcoming Electron Ion Collider (EIC) at the Brookhaven National Laboratory (NY, USA). The magnet has a 2.84 m warm bore diameter and is 3.85 m long. This 15 tons magnet provides a 2.0 T central field at the interaction point with a nominal current of about 4 kA at 4.5 K. The coil is composed of 6 layers of copper stabilized NbTi Rutherford in channel conductor (RIC) and it is wound internally to the brass mandrel. Here, this paper presents the detailed mechanical design of the magnet, starting with the magnet description, the material properties and the acceptance criteria considered. Then, the coil pack properties homogenization process is described. Subsequently, the 2D and 3D calculation models and their assumptions are described. At last, the computational results for the cool down and the energization are discussed. Index Terms—Superconducting Detector Magnet, material properties, homogenization, detector, EIC.

Reymond, Hugo [Commissariat a l'Energie Atomique e↗