At least 199 records · Page 11

Verification of a Modeling Toolkit for the Design of Building Electrical Distribution Systems

DC electrical distribution systems offer many potential advantages over their AC counterparts. They can facilitate easier integration with distributed energy resources, improve system energy efficiency by eliminating AC/DC converters at end-use devices (e.g., laptop chargers), and reduce installation material, time, and cost. However, DC electrical distribution systems present additional design considerations, largely resulting from potentially greater magnitude and variation in cable losses. Modeling and simulation are rarely used to design such systems. However, the greater dependency of DC system energy efficiency on design choices such as distribution voltages, architecture, and integration of PV and BESS suggests that modeling and simulation may be required. Such system performance analysis is currently not a standard practice, in part due to limited availability and validation of capable software tools. This paper characterizes the accuracy of a Modelica-based Building Electrical Efficiency Analysis Model (BEEAM) toolkit, as a precursor for validating its use to perform system performance analysis and inform design decisions. The study builds upon previous verification research by characterizing complete systems comprised of commercially available equipment, and providing a more detailed analysis of simulation results. Five lighting systems with varying electrical distribution architectures were designed using market-available equipment, installed in a laboratory environment, modeled using BEEAM, and simulated using three Modelica integrated development environments (IDEs). Simulated and measured results were compared to characterize toolkit accuracy. Initial results revealed that simulated performance was mostly within ±5% of measured system-level and device-level performance. While simulation results were not found to be dependent on the IDE, some Modelica compiler interoperability issues were identified. Although the BEEAM toolkit showed promise for the targeted use case, further work is needed to determine whether the demonstrated 5% accuracy is sufficient for making real-world design decisions, and for BEEAM to advance from an interesting research tool to one that can impact real-world building projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Battery Energy Storage Systems: A Review of Energy Management Systems and Health Metrics

With increasing concerns about climate change, there is a transition from high-carbon-emitting fuels to green energy resources in various applications including household, commercial, transportation, and electric grid applications. Even though renewable energy resources are receiving traction for being carbon-neutral, their availability is intermittent. To address this issue to achieve extensive application, the integration of energy storage systems in conjunction with these resources is becoming a recommended practice. Additionally, in the transportation sector, the increased demand for EVs requires the development of energy storage systems that can deliver energy for rigorous driving cycles, with lithium-ion-based batteries emerging as the superior choice for energy storage due to their high power and energy densities, length of their life cycle, low self-discharge rates, and reasonable cost. As a result, battery energy storage systems (BESSs) are becoming a primary energy storage system. The high-performance demand on these BESS can have severe negative effects on their internal operations such as heating and catching on fire when operating in overcharge or undercharge states. Reduced efficiency and poor charge storage result in the battery operating at higher temperatures. To mitigate early battery degradation, battery management systems (BMSs) have been devised to enhance battery life and ensure normal operation under safe operating conditions. Some BMSs are capable of determining precise state estimations to ensure safe battery operation and reduce hazards. Precise estimation of battery health is computed by evaluating several metrics and is a central factor in effective battery management systems. In this scenario, the accurate estimation of the health indicators (HIs) of the battery becomes even more important within the framework of a BMS. This paper provides a comprehensive review and discussion of battery management systems and different health indicators for BESSs, with suitable classification based on key characteristics.

Nazaralizadeh, Solmaz (ORCID:0009000737004039)↗

Offshore Wind Farm Turbine and Energy Storage Optimization

Abstract This paper evaluates the technical and economic feasibility of repurposing decommissioned offshore oil and gas platforms as electrical substations for offshore wind projects in the U.S. Gulf of America, a region characterized by relatively low and highly variable wind speeds, extensive legacy offshore infrastructure, and exposure to merchant electricity markets. A unified techno-economic framework is developed using the Repurposing Offshore Infrastructure for Continued Energy (ROICE) Economic Model (REM) to integrate Gulfspecific wind resource assessment, commercial wind turbine performance, offshore infrastructure cost modeling, and wholesale electricity market exposure. Gulf wind speed data are vertically extrapolated to turbine hub height and combined with manufacturer power curves to compute annual energy production and capacity factors across a broad portfolio of commercial turbines, enabling identification of turbine designs best suited for low-wind offshore environments. Hourly electricity price data from the Midcontinent Independent System Operator (MISO) day-ahead market are incorporated to characterize revenue potential, price volatility, and the temporal alignment between wind generation and market conditions. In addition, a conceptual framework for offshore battery energy storage system (BESS) integration is developed to support future investigation of market-responsive energy shifting at repurposed platforms. Results from the turbine evaluation demonstrate that machines with lower cut-in wind speeds and earlier ‘rated-power’ characteristics significantly outperform larger, industry-standard offshore turbines for the same net power under Gulf wind conditions, underscoring the need for region-specific technology selection. Market analysis further reveals substantial price variability and limited intrinsic alignment between wind production and high-price periods, motivating consideration of operational flexibility mechanisms. While storage optimization is not implemented in this study, the REM framework establishes a transparent and replicable foundation for co-evaluating turbine selection, infrastructure constraints, and market exposure, providing a practical pathway for assessing the potential role of repurposed offshore platforms in enabling economically viable offshore wind development in the Gulf of America.

02 PETROLEUM↗

Cosmic-ray Antinuclei as Messengers of New Physics: Status and Outlook for the New Decade

The precise measurement of cosmic-ray antinuclei serves as an important means for identifying the nature of dark matter and other new astrophysical phenomena, and could be used with other cosmic-ray species to understand cosmic-ray production and propagation in the Galaxy. For instance, low-energy antideuterons would provide a "smoking gun" signature of dark matter annihilation or decay, essentially free of astrophysical background. Studies in recent years have emphasized that models for cosmic-ray antideuterons must be considered together with the abundant cosmic antiprotons and any potential observation of antihelium. Therefore, a second dedicated Antideuteron Workshop was organized at UCLA in March 2019, bringing together a community of theorists and experimentalists to review the status of current observations of cosmic-ray antinuclei, the theoretical work towards understanding these signatures, and the potential of upcoming measurements to illuminate ongoing controversies. This review aims to synthesize this recent work and present implications for the upcoming decade of antinuclei observations and searches. This includes discussion of a possible dark matter signature in the AMS-02 antiproton spectrum, the most recent limits from BESS Polar-II on the cosmic antideuteron flux, and reports of candidate antihelium events by AMS-02; recent collider and cosmic-ray measurements relevant for antinuclei production models; the state of cosmic-ray transport models in light of AMS-02 and Voyager data; and the prospects for upcoming experiments, such as GAPS. This provides a roadmap for progress on cosmic antinuclei signatures of dark matter in the coming years.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining the Charge-Sign and Rigidity-Dependence of Solar Modulation

Our ability to identify the sources of cosmic rays and understand how these particles propagate through the interstellar medium is hindered by the combined effects of the solar wind and its embedded magnetic field, collectively known as solar modulation. In this paper, we build upon our previous work to model and constrain the effects of solar modulation on the cosmic-ray spectrum, using data from AMS-02 and BESS Polar II collected between 2007 and 2012, during which the heliospheric magnetic field was in a state of negative polarity. Our model uses measurements of the heliospheric magnetic field and the tilt angle of the heliospheric current sheet to accurately predict the effects of solar modulation as a function of time, charge, and rigidity. By incorporating data from a period of negative polarity, we have been able to robustly observe and constrain the charge-dependent effects of solar modulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids: Preprint

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. Different types of DERs such as Photovoltaics (PV), energy storage, electric vehicles (EVs), etc. have varying effects on the grid based on how and where they are deployed. Again, the DER deployment and its impact are network-dependent, while the traditional electric grids were not designed to host DERs. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper investigates the impacts of integrating a mix of DERs in the utility distribution network in Colorado, U.S. Firstly, BTM DERs at the residential scale including distributed PV; battery energy storage systems (BESS); heating, ventilation, and air-conditioning (HVAC) load; electric water heater (EWH) load; and EVs are modeled. The impacts of integrating these resources on the distribution network are evaluated by conducting time-series simulations for different scenarios considering different days to capture the worst-case conditions. Monte Carlo simulations are conducted to generate the realistic EV charging profile. The voltage issues, substation transformer loadings, and critical nodes in the network are identified with the incorporation of uncoordinated EV charging loads and other DER in the network. This analysis helps visualize the DER impact on the grid, identify the challenges, and provides an insight into the new distribution management and control needs to enable reliable and resilient distribution grid operations. Additionally, further analysis is performed to estimate the daily residential electricity cost with the inclusion of DERs under time-of-use tariffs. The result shows the daily residential electricity cost reduced by 20:7% on average with DERs compared to the case without DERs.

27 ARPA - Advanced Research Projects Agency-Energy↗

Where and When Does Solar Plus Storage Make Sense for Commercial Buildings?

As the capital cost of battery energy storage systems (BESS) declines, opportunities for commercial buildings to achieve net savings through peak demand management and energy arbitrage are emerging. National Renewable Energy Laboratory researchers modeled energy storage project economics - with and without accompanying solar photovoltaic systems - using local utility rates, ASHRAE climate zones, and solar intensity data to identify regions where these systems deliver life cycle savings now and in future cost scenarios.

battery energy storage systems↗

A Modular Optimal Power Flow Method for Integrating New Technologies in Distribution Grids

This work proposes a modular concept to build optimal power flow (OPF) models for distribution networks containing various emerging technologies under diverse ownership structures, to efficiently deal with evolving technology capabilities and information sharing or privacy constraints. This concept will support any typical OPF application (e.g., optimal dispatch of a given asset without violating grid constraints) by coordinating between grid module and technology module without the need to recreate various modeling elements as technology capability changes due to innovation. Moreover, the modularity of the proposed concept enables achieving system level objectives without sharing detailed information on module level objectives and constraints among modules. To achieve this, the proposed work develops a gradient-descent algorithm which builds upon the literature on the state-of-the-art power flow approximation. The proposed concept is demonstrated with two case studies of i) controllable loads and ii) battery energy storage system (BESS) on an actual large-scale distribution grid.

Hanif, Sarmad↗

Power Quality and Stability in a Cluster of Microgrids with Coordinated Power and Energy Management

Distributed Energy Resources (DER) such as photovoltaic (PV) systems and battery energy storage systems (BESS) can be operated collectively as microgrids. Microgrids can be effective in meeting local load requirements as well as in improving the power quality and stability in a modern power distribution system. Multiple microgrids can also be operated in a coordinated manner as a cluster, to improve the resiliency of the power distribution system. In the event of an outage caused by a transmission system failure, the microgrids in a cluster can use their distributed generation capacity and energy storage resources to recover and extend power availability to the critical loads in the system. In this paper, an illustrative cluster of two microgrids based on the IEEE 13-bus model with DERs has been used, to demonstrate the operation of the concept using real-time simulations. Using real-time simulations, capabilities such as switching reconfiguration following faults, identification of optimal DER placement for effective power quality management, and power electronic controller validation have been demonstrated. For the two-microgrid cluster, this paper also presents improvements in load voltage quality and

Chowdhury, Prithwiraj Roy↗

High Penetration Microgrids Providing Grid Stability Using Frequency-Watt Control Presentation

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint.Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

13 HYDRO ENERGY↗

Organizational Influence on Supply Chain for Digital Energy Infrastructure: Business Models, and Policy Landscape

Significant investment is driving the essential modernization and digitization of U.S. energy infrastructure, but the United States faces a key challenge in this grid transformation: our renewable and clean energy supply chains have limited capacity to source necessary digital assets through U.S. or allied sources. Batteries and their associated power electronic interfaces are key components to delivering clean and more resilient energy delivery, providing much-needed fast ramping, emergency discharge, generation, and operations support to the electric grid. These services have grown to be invaluable over the past 10 years and will soon be an irreplaceable component of energy delivery. While there have been significant strides to move supply chains for raw and critical materials to U.S. and allied nations, the control and power electronic industry has lagged, in part because of lower cost margins. For example, the United States now has growing capacity to manufacture solar photovoltaic (PV) panels, but 90% of the inverters—which are essential to the conversion of DC to AC for grid connection and controls—are made in or source parts from the People’s Republic of China (PRC). While a global supply chain is beneficial for many economic and supply diversification reasons, presence of foreign entities of concern (FEOC) in a dominant role in this supply chain brings additional concerns for national security of infrastructure. The BESS relationship and new clean energy have features that warrant discussions and additional focus on impact for technology security, given their critical role. This review considers the impact and solutions for complex business and policy landscapes in clean energy supply chain, and the benefit trade-offs, focusing on the Battery Energy Storage System case study, and its complex organizational relationships across both the US, Allied countries and Foreign Entities of Concern. While many examples in this paper are presented on PRC focused manufacture, this could apply to any potentially adversarial relationship

25 - ENERGY STORAGE↗

Cybersecurity for Digital Energy Infrastructure : Trends, Threats, and Cyber-Informed Engineering

This presentation discusses the rise in digital energy infrastructure and associated threats. It covers an in-depth risk assessment of digital energy equipment and provides real world examples of threats, vulnerabilities, and known incidents. Research conducted by INL assessing and addressing these risks follows, concluding with a dive into Cyber-Informed Engineering (CIE) and it's application to digital energy infrastructure, using battery energy storage systems (BESS) as an example.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Computational Spectroscopy of the Cr–Cr Bond in Coordination Complexes

In this work, we report the accurate computational vibrational analysis of the Cr–Cr bond in dichromium complexes using second-order multireference complete active space methods (CASPT2), allowing direct comparison with experimental spectroscopic data both to facilitate interpreting the low-energy region of the spectra and to provide insights into the nature of the bonds themselves. Recent technological development by the authors has realized such computation for the first time. Accurate simulation of the vibrational structure of these compounds has been hampered by their notorious multiconfigurational electronic structure that yields bond distances that do not correlate with bond order. Some measured Cr–Cr vibrational stretching modes, ν(Cr 2 ), have suggested weaker bonding, even for so-called ultrashort Cr–Cr bonds, while others are in line with the bond distance. Here, we optimize geometries and compute ν(Cr 2 ) with CASPT2 for three well-characterized complexes, Cr 2 (O 2 CCH 3 ) 4 (H 2 O) 2 , Cr 2 (mhp) 4 , and Cr 2 (dmp) 4 . We obtain CASPT2 harmonic ν(Cr 2 ) modes in good agreement with experiment at 282 cm –1 for Cr 2 (mhp) 4 and 353 cm –1 for Cr 2 (dmp) 4 , compute 50 Cr and 54 Cr isotope shifts, and demonstrate that the use of the so-called IPEA shift leads to improved Cr–Cr distances. Additionally, normal mode sampling was used to estimate anharmonicity along ν(Cr 2 ), leading to an anharmonic mode of 272 cm –1 for Cr 2 (mhp) 4 and 333 cm –1 for Cr 2 (dmp) 4 .

36 MATERIALS SCIENCE↗

Quantifying the Influence of Covalent Metal‐Ligand Bonding on Differing Reactivity of Trivalent Uranium and Lanthanide Complexes

Abstract Qualitative differences in the reactivity of trivalent lanthanide and actinide complexes have long been attributed to differences in covalent metal‐ligand bonding, but there are few examples where thermodynamic aspects of this relationship have been quantified, especially with U 3+ and in the absence of competing variables. Here we report a series of dimeric phosphinodiboranate complexes with trivalent f ‐metals that show how shorter‐than‐expected U−B distances indicative of increased covalency give rise to measurable differences in solution deoligomerization reactivity when compared to isostructural complexes with similarly sized lanthanides. These results, which are in excellent agreement with supporting DFT and QTAIM calculations, afford rare experimental evidence concerning the measured effect of variations in metal‐ligand covalency on the reactivity of trivalent uranium and lanthanide complexes.

Fetrow, Taylor V.↗

A Four‐Coordinate Pr 4+ Imidophosphorane Complex

Abstract The imidophosphorane ligand, [NP t Bu 3 ] − ( t Bu= tert ‐butyl), enables isolation of a pseudo‐tetrahedral, tetravalent praseodymium complex, [Pr 4+ (NP t Bu 3 ) 4 ] ( 1‐Pr ), which is characterized by a suite of physical characterization methods including single‐crystal X‐ray diffraction, electron paramagnetic resonance, and L 3 ‐edge X‐ray near‐edge spectroscopies. Variable‐temperature direct‐current magnetic susceptibility data, supported by multiconfigurational quantum chemical calculations, demonstrate that the electronic structure diverges from the isoelectronic Ce 3+ analogue, driven by increased crystal field. The four‐coordinate environment around Pr 4+ in 1‐Pr , which is unparalleled in reported extended solid systems, provides a unique opportunity to study the interplay between crystal field splitting and spin‐orbit coupling in a molecular tetravalent lanthanide within a pseudo‐tetrahedral coordination geometry.

Boggiano, Andrew C.↗

Quantifying the Influence of Covalent Metal‐Ligand Bonding on Differing Reactivity of Trivalent Uranium and Lanthanide Complexes

Abstract Qualitative differences in the reactivity of trivalent lanthanide and actinide complexes have long been attributed to differences in covalent metal‐ligand bonding, but there are few examples where thermodynamic aspects of this relationship have been quantified, especially with U 3+ and in the absence of competing variables. Here we report a series of dimeric phosphinodiboranate complexes with trivalent f ‐metals that show how shorter‐than‐expected U−B distances indicative of increased covalency give rise to measurable differences in solution deoligomerization reactivity when compared to isostructural complexes with similarly sized lanthanides. These results, which are in excellent agreement with supporting DFT and QTAIM calculations, afford rare experimental evidence concerning the measured effect of variations in metal‐ligand covalency on the reactivity of trivalent uranium and lanthanide complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Four‐Coordinate Pr 4+ Imidophosphorane Complex

Abstract The imidophosphorane ligand, [NP t Bu 3 ] − ( t Bu= tert ‐butyl), enables isolation of a pseudo‐tetrahedral, tetravalent praseodymium complex, [Pr 4+ (NP t Bu 3 ) 4 ] ( 1‐Pr ), which is characterized by a suite of physical characterization methods including single‐crystal X‐ray diffraction, electron paramagnetic resonance, and L 3 ‐edge X‐ray near‐edge spectroscopies. Variable‐temperature direct‐current magnetic susceptibility data, supported by multiconfigurational quantum chemical calculations, demonstrate that the electronic structure diverges from the isoelectronic Ce 3+ analogue, driven by increased crystal field. The four‐coordinate environment around Pr 4+ in 1‐Pr , which is unparalleled in reported extended solid systems, provides a unique opportunity to study the interplay between crystal field splitting and spin‐orbit coupling in a molecular tetravalent lanthanide within a pseudo‐tetrahedral coordination geometry.

Boggiano, Andrew C.↗

Formation of a Decanuclear Organometallic Dysprosium Complex via a Radical–Radical Cross–Coupling Reaction

Over the years, polynuclear cyclic or torus complexes have attracted increasing interest due to their unique metal topologies and properties. However, the isolation of polynuclear cyclic organometallic complexes is extremely challenging due to their inherent reactivity, which stems from the labile and reactive metal-carbon bonds. In this study, the pyrazine ligand undergoes a radical-radical cross-coupling reaction leading to the formation of a decanuclear [(Cp*) 20 Dy 10 (L1) 10 ] ⋅ 12(C 7 H 8 ) ( 1 ; where L1 = anion of 2-prop-2-enyl-2 H -pyrazine; Cp* = pentamethylcyclopentadienyl) complex, where all Dy III metal centres are bridged by the anionic L1 ligand. Amongst the family of polynuclear Ln organometallic complexes bearing Cp R 2 Ln x units (Cp R = substituted cyclopentadienyl), 1 features the highest nuclearity obtained to date. In-depth computational studies were conducted to elucidate the proposed reaction mechanism and formation of L1, while probing of the magnetic properties of 1 , revealed slow magnetic relaxation upon application of a static dc field.

cross-coupling↗