Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM SHAPING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Near millimeter wave imaging/multi-beam integrated antennas

This report describes the most recent work on the theory of single element Linearly Tapered Slot Antennas (LTSAs) and Constant Width Slot Antennas (CWSAs). The radiation mechanism for these is presently well understood and allows quantitative calculation of beamwidths and sidelobe levels, provided that the antennas have a sufficiently wide conducting region on either side of the tapered slot. Appendices 4 to 7 represent earlier work on the grant. This work further elucidates the properties of arrays of CWSA elements, and the effects of coupling on the beam-shape. It should be noted that typical beam-efficiencies of 65% have been estimated, and that element spacings of about one Rayleigh unit are possible. Further, two-point resolution at the Rayleigh spacing has been demonstrated for a CWSA array in a 30.4 cm paraboloid at 31 GHz. These results underscore that interest in further studies of the radiation mechanism of tapered slot arrays. Appendix 7 constitutes a final, detailed report on the work leading to a 94 GHz seven element LTSA array imaging system, which has been reported previously in less detail. Experimental results are presented.

Yngvesson, K. S.↗

Microchip and wedge ion funnels and planar ion beam analyzers using same

Electrodynamic ion funnels confine, guide, or focus ions in gases using the Dehmelt potential of oscillatory electric field. New funnel designs operating at or close to atmospheric gas pressure are described. Effective ion focusing at such pressures is enabled by fields of extreme amplitude and frequency, allowed in microscopic gaps that have much higher electrical breakdown thresholds in any gas than the macroscopic gaps of present funnels. The new microscopic-gap funnels are useful for interfacing atmospheric-pressure ionization sources to mass spectrometry (MS) and ion mobility separation (IMS) stages including differential IMS or FAIMS, as well as IMS and MS stages in various configurations. In particular, "wedge" funnels comprising two planar surfaces positioned at an angle and wedge funnel traps derived therefrom can compress ion beams in one dimension, producing narrow belt-shaped beams and laterally elongated cuboid packets. This beam profile reduces the ion density and thus space-charge effects, mitigating the adverse impact thereof on the resolving power, measurement accuracy, and dynamic range of MS and IMS analyzers, while a greater overlap with coplanar light or particle beams can benefit spectroscopic methods.

47 OTHER INSTRUMENTATION↗

Fast IMRT with narrow high energy scanned photon beams

Purpose: Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in combination with fast penumbra trimming multileaf collimators. Previously, experiments have been performed with full range targets, generating a broad bremsstrahlung beam, in combination with multileaf collimators or material compensators. In the present publication, the first measurements with fast narrow high energy (50 MV) scanned photon beams are presented indicating an interesting performance increase even though some of the hardware used were suboptimal. Methods: Inverse therapy planning was used to calculate optimal scanning patterns to generate dose distributions with interesting properties for fast IMRT. To fully utilize the dose distributional advantages with scanned beams, it is necessary to use narrow high energy beams from a thin bremsstrahlung target and a powerful purging magnet capable of deflecting the transmitted electron beam away from the generated photons onto a dedicated electron collector. During the present measurements the scanning system, purging magnet, and electron collimator in the treatment head of the MM50 racetrack accelerator was used with 3-6 mm thick bremsstrahlung targets of beryllium. The dose distributions were measured with diodes in water and with EDR2 film in PMMA. Monte Carlo simulations with geant4 were used to study the influence of the electrons transmitted through the target on the photon pencil beam kernel. Results: The full width at half-maximum (FWHM) of the scanned photon beam was 34 mm measured at isocenter, below 9.5 cm of water, 1 m from the 3 mm Be bremsstrahlung target. To generate a homogeneous dose distribution in a 10 x 10 cm{sup 2} field, the authors used a spot matrix of 100 equal intensity beam spots resulting in a uniformity of collimated 80%-20% penumbra of 9 mm at a primary electron energy of 50 MeV. For the more complex cardioid shaped dose distribution, they used 270 spots, which at a pulse repetition frequency of 200 Hz is completed every 1.36 s. Conclusions: The present measurements indicate that the use of narrow scanned photon beams is a flexible and fast method to deliver advanced intensity modulated beams. Fast scanned photon IMRT should, therefore, be a very interesting modality in the delivery of biologically optimized radiation therapy with the possibility for in vivo treatment verification with PET-CT imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

6D Phase Space Measurement of Low Energy, High Intensity Hadron Beam

The goal of this experiment is to measure the full 6D phase space of a low energy, high intensity hadron beam. We use 4D emittance measurement techniques for the transverse plane combined with dispersion measurement and a beam shape monitor to provide the longitudinal phase space. The Beam Testing Facility (BTF) at the Spallation Neutron Source (SNS), a 2.5 MeV functional duplicate front end of the SNS accelerator is being used to facilitate the measurement. Early 6D measurements will be presented.

Cathey, Brandon↗

All-optical, optically addressable liquid crystal-based light valve employing photoswitchable alignment layer for high-power and/or large aperture laser applications

A beam shaping system including an all-optical liquid crystal beam shaper, the beam shaper including a photoswitchable alignment material including at least one of a PESI-F, SPMA:MMA 1:5, SPMA:MMA 1:9, ora SOMA:SOMA-p:MMA 1:1:6 material, at least some of the liquid crystals of the beam shaper including at least one of a phenylcyclohexane, cyclo-cyclohexane, or a perfluorinated material.

Marshall, Kenneth L.↗

Beam-centric algorithm for pretreatment patient position correction in external beam radiation therapy

Purpose: In current image guided pretreatment patient position adjustment methods, image registration is used to determine alignment parameters. Since most positioning hardware lacks the full six degrees of freedom (DOF), accuracy is compromised. The authors show that such compromises are often unnecessary when one models the planned treatment beams as part of the adjustment calculation process. The authors present a flexible algorithm for determining optimal realizable adjustments for both step-and-shoot and arc delivery methods. Methods: The beam shape model is based on the polygonal intersection of each beam segment with the plane in pretreatment image volume that passes through machine isocenter perpendicular to the central axis of the beam. Under a virtual six-DOF correction, ideal positions of these polygon vertices are computed. The proposed method determines the couch, gantry, and collimator adjustments that minimize the total mismatch of all vertices over all segments with respect to their ideal positions. Using this geometric error metric as a function of the number of available DOF, the user may select the most desirable correction regime. Results: For a simulated treatment plan consisting of three equally weighted coplanar fixed beams, the authors achieve a 7% residual geometric error (with respect to the ideal correction, considered 0% error) by applying gantry rotation as well as translation and isocentric rotation of the couch. For a clinical head-and-neck intensity modulated radiotherapy plan with seven beams and five segments per beam, the corresponding error is 6%. Correction involving only couch translation (typical clinical practice) leads to a much larger 18% mismatch. Clinically significant consequences of more accurate adjustment are apparent in the dose volume histograms of target and critical structures. Conclusions: The algorithm achieves improvements in delivery accuracy using standard delivery hardware without significantly increasing total treatment session duration. It encourages parsimonious utilization of all available DOF. Finally, in certain cases, it obviates the need of a robotic couch having six DOF for the correction of patient displacement and rotations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integration of an Axcelis Optima HD Single Wafer High Current Implanter for p- and n-S/D Implants in an Existing Batch Implanter Production Line

This paper is focused on the integration and qualification of an Axcelis Optima HD single wafer high current spot beam implanter in an existing 200 mm production line with different types of Axcelis batch implanters for high current applications. Both the design of the beamline and the beam shape are comparable between single wafer and batch high current spot beam implanters. In contrast to the single wafer high current ribbon beam implanter, energy contamination is not a concern for the considered spot beam tool because the drift mode can be used down to energies in the 2 keV region. The most important difference between single wafer and batch high current implanters is the significantly higher dose rate and, therefore, the higher damage rate for the single wafer tool due to the different scanning architecture. The results of the integration of high dose implantations, mainly for p- and n-S/D formation, for DRAM 110 nm without pre-amorphization implantation (PAI), CMOS Logic from around 250 nm down to 90 nm without and with PAI, are presented and discussed. Dopant concentration profile analysis using SIMS was performed for different technologies and implantation conditions. The impurity activation was measured using sheet resistance and in some cases spreading resistance technique was applied. The amorphous layer thickness was measured using TEM. Finally, device data are presented in combination with dose, energy and beam current variations. The results have shown that the integration of implantation processes into crystalline structure without PAI is more complex and time consuming than implantations into amorphous layer where the damage difference due to the different dose rates is negligible.

36 MATERIALS SCIENCE↗

SU-F-T-176: Therapeutic Proton Beam Range Measurement Method with EBT3 Film

Purpose: Ocular proton therapy has the following advantages: i) sparing optic nerve, ii) the minimal dose is delivered to surrounding normal tissues. Since the proton therapy center was opened in 2007, 30 patients with ocular tumor have been treated at National Cancer Center using single scattering technique. To develop a solid eye phantom which can verify the output and the beam range with EBT3 film for independent patient QA in ocular proton therapy. Methods: The proton therapy is very effective to treat ocular tumor, because of the Bragg peak feature. In general, the beam shape of eye treatment is about 3 cm in diameter and the beam range is under 5 cm. However, proton therapy has uncertainty of beam range problem due to various stopping power of normal tissue, bone, air and so on, so that we should verify the beam range before treatment. For this purpose, a new PMMA phantom with wedge has been developed to use the film dosimetry and the ionization chamber. It is able to place a film on the slope of the phantom, which the spread out Bragg Peak by the water equivalent thickness value of PMMA can be made on the film. We considered to relation with quenching effect of proton energy and range for simple second check. In addition, the ionization chamber (Pin-point chamber, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose. Results: The output difference and beam range difference were less than 2% and 1.0 mm, respectively, between the measurement and the plan. Conclusion: An eye phantom was developed and its performance was evaluated successfully and it was useful to verify the output. Also with EBT3 film with the quenching effect for measurement depth-dose profile, range to patient QA.

60 APPLIED LIFE SCIENCES↗

Power Density Distributions in Electron Beams

Measuring and controlling the power density distribution of electron beams used for welding is critical for producing repeatable welds and for transferring welding parameters between different machines. On any given machine, the power density distribution is controlled by defocusing the beam relative to its sharpest focused condition. However, measuring the power density distribution can be difficult due to the intense nature of welding beams and is further complicated by imperfect electron optics that can distort the beam, making it difficult to quantify. The enhanced modified Faraday cup (EMFC) diagnostic method was used here for beam analysis that utilizes computed tomography to reconstruct the beam’s power density distribution. These results were compared to the International Standards Organization (ISO) method for characterizing laser beams using a second-moment D4σ calculation. For ideal Gaussian-shaped beams, both methods would give the same result. However, for imperfect beams, the calculated D4σ diameter was shown to be about 25% larger relative to the FWe2 diameter measured by the EMFC due to the heavier weighting of data in the tails of the beam by D4σ. Finally, although both methods produce repeatable welds, it is important to understand the differences in the reported beam diameters, divergence angles, and beam parameter products when transferring parameters between machines.

36 MATERIALS SCIENCE↗

Control of low-mode drive asymmetry in an efficient long-pulse low gas-fill density Hohlraum

Laser-driven Hohlraums filled with gas at lower densities (<0.6 mg/cc) have higher efficiency compared to original ≥ 0.96 mg/cc fill because of reduced backscatter losses [Hall et al., Phys. Plasmas 24, 052706 (2017)]. However, using low-density filled Hohlraums with longer drive required for lower adiabat implosions, and hence potentially higher inertial confinement fusion gain designs, has been challenging since the Hohlraum wall blow-off is less tamped, thus altering the laser beam absorption regions and drive symmetry. A series of NIF experiments using optimized pulse shaping, beam pointing, and temporal phasing have demonstrated, through imaging of the Hohlraum and capsule dynamics, that a symmetric implosion using a 14-ns low-adiabat drive pulse {2× longer than high-density-carbon ablator designs using low gas-fill density Hohlraums [Divol et al., Phys. Plasmas 24, 056309 (2017)]} is possible in a low backscatter loss 0.45 mg/cc He-filled Hohlraum. The ingress of the Hohlraum walls was mitigated by revisiting the adiabat-shaped design [Clark et al., Phys. Plasmas 21, 112705 (2014)] that uses a low-power (1 TW) trough that delays the wall expansion. Low-mode P 2 and P 4 drive asymmetry swings caused by the drift of the laser spots were essentially zeroed out by employing temporal beam phasing between cones of beams [Turner et al., Phys. Plasmas 7, 333 (2000)]. So the results also indicate an improved coupling efficiency of ~30% compared to an earlier design using higher density filled Hohlraums and pave the way for revisiting low-adiabat, high convergence drives using CH ablators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using an Emittance Exchange Scheme for High Harmonic Generation by Free-Electron Lasers

We propose combining a transverse-to-longitudinal emittance exchange beam line and a conventional modulator to generate high harmonics with short-wavelength free-electron lasers. The key point of this scheme is the use of a multi-slit mask to create a transverse-shaped beam. In an emittance exchange beam line, the transverse-shaped bunch will produce a longitudinal-shaped one, resulting in separated energy bands. The modulator that follows this step will generate micro-bunches containing high harmonics. A coherent synchrotron radiation effect is also considered in this paper; compared to the two-modulator scheme, the method investigated here is more flexible and can be used to relax the coherent synchrotron radiation effect.

43 PARTICLE ACCELERATORS↗

FAST PIXEL SPACE CONVOLUTION FOR COSMIC MICROWAVE BACKGROUND SURVEYS WITH ASYMMETRIC BEAMS AND COMPLEX SCAN STRATEGIES: FEBeCoP

Precise measurement of the angular power spectrum of the cosmic microwave background (CMB) temperature and polarization anisotropy can tightly constrain many cosmological models and parameters. However, accurate measurements can only be realized in practice provided all major systematic effects have been taken into account. Beam asymmetry, coupled with the scan strategy, is a major source of systematic error in scanning CMB experiments such as Planck, the focus of our current interest. We envision Monte Carlo methods to rigorously study and account for the systematic effect of beams in CMB analysis. Toward that goal, we have developed a fast pixel space convolution method that can simulate sky maps observed by a scanning instrument, taking into account real beam shapes and scan strategy. The essence is to pre-compute the 'effective beams' using a computer code, 'Fast Effective Beam Convolution in Pixel space' (FEBeCoP), that we have developed for the Planck mission. The code computes effective beams given the focal plane beam characteristics of the Planck instrument and the full history of actual satellite pointing, and performs very fast convolution of sky signals using the effective beams. In this paper, we describe the algorithm and the computational scheme that has been implemented. We also outline a few applications of the effective beams in the precision analysis of Planck data, for characterizing the CMB anisotropy and for detecting and measuring properties of point sources.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-340: Dosimetry of a Small Field Electron Beam for Innovative Radiotherapy of Small Surface Or Internal Tumors

Purpose: An innovative small high intensity electron beams with energies from 6 to 12 MeV is being developed at Argonne National Laboratory to deliver an absorbed dose via a catheter to small malignant and nonmalignant lesions. This study reports on the initial dosimetric characteristics of this electron beam. These include output calibration, percent depth dose, beam profiles and leakage through the catheter. Methods: To simulate the narrow electron beam, the Argonne Wakefield Accelerator is used to produce high energy electron beams. The electron beam from the accelerator is monitored by measuring the current through a transmission coil while the beam shape is observed with a fluorescent screen. The dosimetry properties of the electron beam transmitting through bone and tissue-like materials are measured with nanodot optically stimulated luminescent dosimeters and EDR radiographic film. The 6 MV photon beam from a Varian True beam linac is used to calibrate both the OSLDs and the film. Results: The beam characteristics of the 12 MeV beam were measured. The properties of the small diameter, 5 mm, beam differs from that of broad clinical electron beams from radiotherapy linacs. Due to the lack of scatter from the narrow beam, the maximum dose is at the surface and the depth of the 50% depth dose is 35 mm compared to 51 mm for a clinical 12 MeV. The widths of the 90% isodose measured at the surface and depths of 2, 6, 12, and 16 mm varied from 6.6 to 8.8 mm while the widths of the FWHM isodose varied from 7.8 to 25.5 mm. Conclusion: Initial beam measurements show favorable dosimetric properties for its use in treating either small surface or internal lesions, particularly to deliver radiation at the time of surgery to maximize the dose to the lesion and spare normal tissue.

60 APPLIED LIFE SCIENCES↗

New x-ray pink-beam profile monitor system for the SPring-8 beamline front-end

A new beam profile monitoring system for the small X-ray beam exiting from the SPring-8 front-end was developed and tested at BL13XU. This system is intended as a screen monitor and also as a position monitor even at beam currents of 100 mA by using photoluminescence of a chemical vapor deposition-grown diamond film. To cope with the challenge that the spatial distribution of the photoluminescence in the vertical direction is too flat to detect the beam centroid within a limited narrow aperture, a filter was installed that absorbs the fundamental harmonic concentrated in the beam center, which resulted in “de-flattening” of the vertical distribution. For the measurement, the filter crossed the photon beam vertically at high speed to withstand the intense heat flux of the undulator pink-beam. A transient thermal analysis, which can simulate the movement of the irradiation position with time, was conducted to determine the appropriate configuration and the required moving speed of the filter to avoid accidental melting. In a demonstration experiment, the vertically separated beam profile could be successfully observed for a 0.8 × 0.8 mm{sup 2} beam shaped by an XY slit and with a fundamental energy of 18.48 keV. The vertical beam centroid could be detected with a resolution of less than 0.1 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Disruption Mitigation Solutions for Long Pulse Tokamaks (Final Technical Report)

The project "Disruption Mitigation Solutions for Long Pulse Tokamaks" was a collaborative effort between ORNL, GA, and UCSD. The main goal of the project was to study the injection of shattered cryogenic pellets (SPI) as a method of reducing wall damage from global tokamak plasma instabilities called disruptions. This work was primarily carried out in the JET tokamak in the UK. The team already had extensive experience studying PSI in the medium sized DIII-D tokamak in the US, but adding data from the larger JET tokamak enabled more confident extrapolation to the even larger planned ITER tokamak in France. Each of the collaborating institutions focused on different aspects of SPI disruption mitigation. The UCSD collaboration focused on the volume recombination of post-disruption runaway electron (RE) beams by massive hydrogen injection. Disruptions can sometimes result in the formation of toroidal (ring shaped) beams of highly energetic (relativistic) electron beams, which can cause serious local wall damage, even in present-day tokamaks. A promising method to reduce wall damage from the RE beams is to inject massive amounts of H 2 or D 2 into the beams using SPI. although the precise method by which the injected H 2 reducses RE wall damage is still being investigated, it seems clear that a necessary and required step for the reduction to occur is for the H 2 injection to cause volume recombination (free electron density reduction) of the background cold plasma surrounding the fast electron beam. The UCSD collaboration focused on answering the question of if this recombination could be achievable in the future reactor-size tokamak ITER using realistic levels of H 2 injection. A model capturing the most essential physics was developed and was constrained using both DIII-D and JET data. This model was then used to extrapolate to ITER. It was predicted that RE beam recombination should be achievable in ITER, although in the worst-case scenari (a 10 MA Re beam in ITER), recombination is barely achieved within the maximum allowed levels of H 2 injection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron beam gun with kinematic coupling for high power RF vacuum devices

An electron beam gun for a high power RF vacuum device has components joined by a fixed kinematic coupling to provide both precise alignment and high voltage electrical insulation of the components. The kinematic coupling has high strength ceramic elements directly bonded to one or more non-ductile rigid metal components using a high temperature active metal brazing alloy. The ceramic elements have a convex surface that mates with concave grooves in another one of the components. The kinematic coupling, for example, may join a cathode assembly and/or a beam shaping focus electrode to a gun stem, which is preferably composed of ceramic. The electron beam gun may be part of a high power RF vacuum device such as, for example, a gyrotron, klystron, or magnetron.

36 MATERIALS SCIENCE↗

Design, fabrication, and testing of diamond axicons for X-ray microscopy applications

This work presents the design, fabrication, and experimental validation of a refractive diamond axicon for X-ray beam shaping. The diamond axicon was developed to overcome the limitations of polymer-based axicons particularly for application in Transmission X-ray Microscopy (TXM) systems, offering superior mechanical strength, thermal stability, and radiation resistance, making it ideal for synchrotron applications. The axicon was fabricated using femtosecond laser ablation and tested at 11 keV under various coherence conditions. Results demonstrated that the axicon efficiently transformed the X-ray beam into a ring-shaped profile with over 80% transmission. Simulations confirmed the experimental findings and highlighted the potential for further improvements. This work paves the way for the use of diamond axicons in next-generation synchrotron facilities, with future efforts focusing on optimizing fabrication and testing the axicon in full TXM systems.

Samadi, Nazanin↗