Dosimetric commissioning and quality assurance of scanned ion beams at the Italian National Center for Oncological Hadrontherapy

Purpose: To describe the dosimetric commissioning and quality assurance (QA) of the actively scanned proton and carbon ion beams at the Italian National Center for Oncological Hadrontherapy. Methods: The laterally integrated depth-dose-distributions (IDDs) were acquired with the PTW Peakfinder, a variable depth water column, equipped with two Bragg peak ionization chambers. FLUKA Monte Carlo code was used to generate the energy libraries, the IDDs in water, and the fragment spectra for carbon beams. EBT3 films were used for spot size measurements, beam position over the scan field, and homogeneity in 2D-fields. Beam monitor calibration was performed in terms of number of particles per monitor unit using both a Farmer-type and an Advanced Markus ionization chamber. The beam position at the isocenter, beam monitor calibration curve, dose constancy in the center of the spread-out-Bragg-peak, dose homogeneity in 2D-fields, beam energy, spot size, and spot position over the scan field are all checked on a daily basis for both protons and carbon ions and on all beam lines. Results: The simulated IDDs showed an excellent agreement with the measured experimental curves. The measured full width at half maximum (FWHM) of the pencil beam in air at the isocenter was energy-dependent for both particle species: in particular, for protons, the spot size ranged from 0.7 to 2.2 cm. For carbon ions, two sets of spot size are available: FWHM ranged from 0.4 to 0.8 cm (for the smaller spot size) and from 0.8 to 1.1 cm (for the larger one). The spot position was accurate to within ±1 mm over the whole 20 × 20 cm{sup 2} scan field; homogeneity in a uniform squared field was within ±5% for both particle types at any energy. QA results exceeding tolerance levels were rarely found. In the reporting period, the machine downtime was around 6%, of which 4.5% was due to planned maintenance shutdowns. Conclusions: After successful dosimetric beam commissioning, quality assurance measurements performed during a 24-month period show very stable beam characteristics, which are therefore suitable for performing safe and accurate patient treatments.

60 APPLIED LIFE SCIENCES↗

Development and commissioning of an x-ray beam alignment flag for NSLS-II

The NSLS-II Synchrotron Light Source is a 3 GeV electron storage ring recently commissioned and is now entering operations at Brookhaven National Laboratory. One of the major tasks was to commission the six project beamline front ends which required a diagnostic to resolve x-ray beam position for the purpose of beam alignment at low current. Since none of the front ends were outfitted with any x-ray diagnostics in the baseline design, an x-ray beam profile monitor or “flag” that could be easily installed into existing front end vacuum chambers was proposed to satisfy this requirement. Here we present the development of this novel device which utilizes a polycrystalline CVD diamond luminescent screen to produce a visible image of the x-ray beam cross-section and is then captured with a CCD camera.

43 PARTICLE ACCELERATORS↗

Evaluation of three lidar scanning strategies for turbulence measurements

Abstract. Several errors occur when a traditional Doppler beam swinging (DBS) or velocity–azimuth display (VAD) strategy is used to measure turbulence with a lidar. To mitigate some of these errors, a scanning strategy was recently developed which employs six beam positions to independently estimate the u, v, and w velocity variances and covariances. In order to assess the ability of these different scanning techniques to measure turbulence, a Halo scanning lidar, WindCube v2 pulsed lidar, and ZephIR continuous wave lidar were deployed at field sites in Oklahoma and Colorado with collocated sonic anemometers.Results indicate that the six-beam strategy mitigates some of the errors caused by VAD and DBS scans, but the strategy is strongly affected by errors in the variance measured at the different beam positions. The ZephIR and WindCube lidars overestimated horizontal variance values by over 60 % under unstable conditions as a result of variance contamination, where additional variance components contaminate the true value of the variance. A correction method was developed for the WindCube lidar that uses variance calculated from the vertical beam position to reduce variance contamination in the u and v variance components. The correction method reduced WindCube variance estimates by over 20 % at both the Oklahoma and Colorado sites under unstable conditions, when variance contamination is largest. This correction method can be easily applied to other lidars that contain a vertical beam position and is a promising method for accurately estimating turbulence with commercially available lidars.

Newman, Jennifer F.↗

Linear Regression Systematics of the Q-weak Main Detector Asymmetry

The Q-weak collaboration has made the first direct measurement of the proton's weak charge at Jefferson Lab to tightly constrain new, parity-violating electron-quark interactions at the multi-TeV scale. Our experiment measured the ?200 ppb parity-violating asymmetry in the scattering of longitudinally polarized electrons from an unpolarized liquid hydrogen target at a luminosity of 1.8x10^39. Careful setup of the injector helped to suppress helicity correlated differences in beam position, angle, and energy which create false asymmetries due to changes in detector acceptance and the kinematic dependences of the e+p cross section. Measured differences in beam position were consistent among all 6 beam position monitors in front of the target, with a precision of ?1 nanometer. The size of corrections depends on the helicity correlated beam parameter differences, and averaged about 35 ppb per shift of data. The data were regressed using 10 different sets of Independent Variables. These were expected to give similar corrections yet showed differences at the +-10 ppb level. In this presentation I'll summarize how these different schemes have not only been helpful in understanding the sensitivities of the main detector but in assigning errors to the corrections.

Mack, David↗

Experimental demonstration of interaction region beam waist position knob for luminosity leveling

In this paper, we report the experimental implementation of the model-dependent control of the interaction region beam waist position (s * knob) at Relativistic Heavy Ion Collider (RHIC). The s * adjustment provides an alternative way of controlling the luminosity and is only known method to control the luminosity and reduce the pinch effect of the future eRHIC. In this paper, we will first demonstrate the effectiveness of the s * knob in luminosity controlling and its application in the future electron ion collider, eRHIC, followed by the detail experimental demonstration of such knob in RHIC.

43 PARTICLE ACCELERATORS↗

Conceptual design of front ends for the advanced photon source multi-bend achromats upgrade

The proposed Advanced Photon Source (APS) upgrade from a double-bend achromats (DBA) to multi-bend achromats (MBA) lattice with ring energy change from 7 GeV to 6 GeV and beam current from 100 mA to 200 mA poses new challenges for front ends. All front ends must be upgraded to fulfill the following requirements: 1) handle the high heat load from two insertion devices in either inline or canted configuration, 2) include a clearing magnet in the front end to deflect and dump any electrons in case the electrons escape from the storage ring during swap-out injection with the safety shutters open, 3) incorporate the next generation x-ray beam position monitors (XBPMs) into the front end to meet the new stringent beam stability requirements. This paper presents the evaluation of the existing APS front ends and standardizes the insertion device (ID) front ends into two types: one for the single beam and one for the canted beams. The conceptual design of high heat load front end (HHLFE) and canted undulator front end (CUFE) for APS MBA upgrade is presented.

43 PARTICLE ACCELERATORS↗

Evaluation of Heat Dissipation in the BPM Buttons

Growth of circulating current in the storage rings drastically increases heating of the beam position monitor (BPM) buttons due to the induced trapped modes is drastically increasing. Excessive heating can lead to the errors in the measuring of beam position or even catastrophic failures of the pick-up assembly. In this paper we present calculations of heat generated in the button for different geometries and materials. The obtained results are used for the optimization of the NSLS-II BPM buttons design.

43 PARTICLE ACCELERATORS↗

A Prototype Wire Position Monitoring System

The Wire Position Monitoring System (WPM) will track changes in the transverse position of LCLS Beam Position Monitors (BPMs) to 1{micro}m over several weeks. This position information will be used between applications of beam based alignment to correct for changes in component alignment. The WPM system has several requirements. The sensor range must be large enough so that precision sensor positioning is not required. The resolution needs to be small enough so that the signal can be used to monitor motion to 1{micro}m. The system must be stable enough so that system drift does not mimic motion of the component being monitored. The WPM sensor assembly consists of two parts, the magnetic sensor and an integrated lock-in amplifier. The magnetic sensor picks up a signal from the alternating current in a stretched wire. The voltage v induced in the sensor is proportional to the wire displacement from the center of the sensor. The integrated lock-in amplifier provides a DC output whose magnitude is proportional to the AC signal from the magnetic sensor. The DC output is either read on a digital voltmeter or digitized locally and communicated over a computer interface.

43 PARTICLE ACCELERATORS↗

BPM Button Optimization to Minimize Distortion Due to Trapped Mode Heating

The outer circumference of a BPM button and the inner circumference of the button housing comprise a transmission line. This transmission line typically presents an impedance of a few tens of ohms to the beam, and couples very weakly to the 50 ohm coaxial transmission line that comprises the signal path out of the button. The modes which are consequently excited and trapped often have quality factors of several hundred, permitting resonant excitation by the beam. The thermal distortion resulting from trapped mode heating is potentially problematic for achieving the high precision beam position measurements needed to provide the sub-micron beam position stability required by light source users. We present a button design that has been optimized via material selection and component geometry to minimize both the trapped mode heating and the resulting thermal distortion.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of the one-way speed of light anisotropy with particle beams

Concepts of high precision studies of the one-way speed of light anisotropy are discussed. The high energy particle beam allows measurement of a one-way speed of light anisotropy (SOLA) via analysis of the beam momentum variation with sidereal phase without the use of synchronized clocks. High precision beam position monitors could provide accurate monitoring of the beam orbit and determination of the particle beam momentum with relative accuracy on the level of 10^-10, which corresponds to a limit on SOLA of 10^-18 with existing storage rings. A few additional versions of the experiment are also presented.

Wojtsekhowski, Bogdan B.↗

High resolution BPMS with integrated gain correction system

High resolution beam position monitors (BPM) are an essential tool to achieve and reproduce a low vertical beam emittance at the KEK Accelerator Test Facility (ATF) damping ring. The ATF damping ring (DR) BPMs are currently upgraded with new high resolution read-out electronics. Based on analog and digital down-conversion techniques, the upgrade includes an automatic gain calibration system to correct for slow drift effects and ensure high reproducible beam position readings. The concept and its technical realization, as well as preliminary results of beam studies are presented.

43 PARTICLE ACCELERATORS↗

Development of Diamond-Based X-ray Detection for High Flux Beamline Diagnostics

High-quality single-crystal and polycrystalline chemical-vapor-deposition diamond detectors with platinum contacts have been tested at the white-beam X28C beamline at the National Synchrotron Light Source under high-flux conditions. The voltage dependence of these devices has been measured under both DC and pulsed-bias conditions, establishing the presence or absence of photoconductive gain in each device. Linear response consistent with the theoretically determined ionization energy has been achieved over eleven orders of magnitude when combined with previous low-flux studies. Temporal measurements with single-crystal diamond detectors have resolved the nanosecond-scale pulse structures of both the NSLS and the APS. Prototype single-crystal quadrant detectors have provided the ability to simultaneously resolve the X-ray beam position and obtain a quantitative measurement of the flux.

36 MATERIALS SCIENCE↗

The Straightness Monitor System at ATF2

The demonstration of absolute stability of the position of the focused beam is the primary goal of the ATF2 commissioning effort. We have installed a laser interferometer system that will eventually correct the measurement of high-precision Beam Position Monitors used in the ATF2Final Focus Steering Feedback for mechanical motion or vibrations. Here, we describe the installed system and present preliminary data on the short- and long-term mechanical stability of the BPM system.

43 PARTICLE ACCELERATORS↗

Measurement of Beam Energy in the Fermilab's Linac taken at the Transfer Line

Linac is the first machine in the accelerator chain at Fermilab where H$^{-}$ ions are accelerated from 35 keV to 401.5\,MeV and then injected into a synchronton known as Booster where they are stripped of their electrons to become protons. One of the tools used during tuning of the Linac extraction energy is two beam pickups known as Griffin Detectors. Our goal is to control the output energy using machine learning techniques to increase the reliability and quality of the beam delivered from Linac. The first step is to understand the data from the diagnostics to develop reliable and accurate energy measurement, and control methods before implementing machine learning techniques. Two methods of energy measurement were studied, and their results are compared. The first method was the time of flight measurement using Beam Position Monitors that provide beam phase measurement. The second method used the relation between beam transverse positions and dispersion values to calculate momentum variation. The results of these two measurement methods are found to be consistent.

43 PARTICLE ACCELERATORS↗

Injection System Diagnostics

The linac beam diagnostics will be provided by Research Instruments (former ACCEL) as part of the linac package: • one removable Faraday cup after electron source, • five wall current monitors (WCM) located after electron source, bunching system and accelerating sections 1, 2, and 3, • six removable YAG:Ce screens including cameras, • five sets of buttons for beam position monitoring. BNL will provide receivers for the beam position monitors (BPMs).

36 MATERIALS SCIENCE↗

A NOVEL METHOD FOR QUASI-NON-INTERCEPTIVE BEAM PROFILE MEASUREMENT IN A LINAC

Beam profile diagnostics is an important tool for understanding beam dynamics in accelerators. Non-interceptive diagnostics have many great advantages but often are difficult in implementation. We suggest a method of measuring beam profiles that is not truly non-interceptive, because beam has to be intercepted at some point, preferably in the beginning of the linac. But significant difference from a conventional interceptive measurement is that beam is not intercepted at any of the points of measurement along the linac. One important application is measuring beam profiles within cryostats of a super-conducting linac. The equipment required for implementing this diagnostic is simple: a set of slits in the beginning of the accelerator, and a Beam Position Monitor (BPM) in the point of measurement. Beam profiles can be measured simultaneously at every BPM along the linac. In this paper we will discuss details of the method, its limitations, and effect of non-linearity, coupling and space charge. Results of a demonstration experiment at SNS will be presented and discussed.

43 PARTICLE ACCELERATORS↗

Simultaneous multibeam sounding of wind and turbulence

Most clear air radars use an antenna with either a few fixed beam positions or one that can be steered to a number of beam positions, one position at a time. For spatial studies of parameters that can change rapidly these conventional radar may be severely limited. The problem is that the fixed beam radars do not cover enough positions and the steerable radars may not be able to cover the entire field of interest in a short enough time period. Preliminary results are presented from a brief experiment that suggests a way to overcome some of these space-time problems in clear air radar research. A typical clear air radar antenna located in France was modified in a simple way to produce a number of beam simultaneouly. The radar, the modifications and the resulting beam patterns are described. Spectra is then shown obtained with the multibeam array and some results are presented on the spatial variations of reflectivity. Both the positive and negative aspects of using a multibeam antenna array for clear air radar studies are summarized.