Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Measurement of fast-changing low velocities by photonic Doppler velocimetry

Despite the increasing popularity of photonic Doppler velocimetry (PDV) in shock wave experiments, its capability of capturing low particle velocities while changing rapidly is still questionable. The paper discusses the performance of short time Fourier transform (STFT) and continuous wavelet transform (CWT) in processing fringe signals of fast-changing low velocities measured by PDV. Two typical experiments are carried out to evaluate the performance. In the laser shock peening test, the CWT gives a better interpretation to the free surface velocity history, where the elastic precursor, main plastic wave, and elastic release wave can be clearly identified. The velocities of stress waves, Hugoniot elastic limit, and the amplitude of shock pressure induced by laser can be obtained from the measurement. In the Kolsky-bar based tests, both methods show validity of processing the longitudinal velocity signal of incident bar, whereas CWT improperly interprets the radial velocity of the shocked sample at the beginning period, indicating the sensitiveness of the CWT to the background noise. STFT is relatively robust in extracting waveforms of low signal-to-noise ratio. Data processing method greatly affects the temporal resolution and velocity resolution of a given fringe signal, usually CWT demonstrates a better local temporal resolution and velocity resolution, due to its adaptability to the local frequency, also due to the finer time-frequency product according to the uncertainty principle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-I-43: A Software-Based Statistical Method to Compute Low Contrast Detectability in Computed Tomography Images

Purpose: The low contrast detectability (LCD) of a CT scanner is its ability to detect and display faint lesions. The current approach to quantify LCD is achieved using vendor-specific methods and phantoms, typically by subjectively observing the smallest size object at a contrast level above phantom background. However, this approach does not yield clinically applicable values for LCD. The current study proposes a statistical LCD metric using software tools to not only to assess scanner performance, but also to quantify the key factors affecting LCD. This approach was developed using uniform QC phantoms, and its applicability was then extended under simulated clinical conditions. Methods: MATLAB software was developed to compute LCD using a uniform image of a QC phantom. For a given virtual object size, the software randomly samples the image within a selected area, and uses statistical analysis based on Student’s t-distribution to compute the LCD as the minimal Hounsfield Unit’s that can be distinguished from the background at the 95% confidence level. Its validity was assessed by comparison with the behavior of a known QC phantom under various scan protocols and a tissue-mimicking phantom. The contributions of beam quality and scattered radiation upon the computed LCD were quantified by using various external beam-hardening filters and phantom lengths. Results: As expected, the LCD was inversely related to object size under all scan conditions. The type of image reconstruction kernel filter and tissue/organ type strongly influenced the background noise characteristics and therefore, the computed LCD for the associated image. Conclusion: The proposed metric and its associated software tools are vendor-independent and can be used to analyze any LCD scanner performance. Furthermore, the method employed can be used in conjunction with the relationships established in this study between LCD and tissue type to extend these concepts to patients’ clinical CT images.

60 APPLIED LIFE SCIENCES↗

Dynamic cone beam CT angiography of carotid and cerebral arteries using canine model

Purpose: This research is designed to develop and evaluate a flat-panel detector-based dynamic cone beam CT system for dynamic angiography imaging, which is able to provide both dynamic functional information and dynamic anatomic information from one multirevolution cone beam CT scan. Methods: A dynamic cone beam CT scan acquired projections over four revolutions within a time window of 40 s after contrast agent injection through a femoral vein to cover the entire wash-in and wash-out phases. A dynamic cone beam CT reconstruction algorithm was utilized and a novel recovery method was developed to correct the time-enhancement curve of contrast flow. From the same data set, both projection-based subtraction and reconstruction-based subtraction approaches were utilized and compared to remove the background tissues and visualize the 3D vascular structure to provide the dynamic anatomic information. Results: Through computer simulations, the new recovery algorithm for dynamic time-enhancement curves was optimized and showed excellent accuracy to recover the actual contrast flow. Canine model experiments also indicated that the recovered time-enhancement curves from dynamic cone beam CT imaging agreed well with that of an IV-digital subtraction angiography (DSA) study. The dynamic vascular structures reconstructed using both projection-based subtraction and reconstruction-based subtraction were almost identical as the differences between them were comparable to the background noise level. At the enhancement peak, all the major carotid and cerebral arteries and the Circle of Willis could be clearly observed. Conclusions: The proposed dynamic cone beam CT approach can accurately recover the actual contrast flow, and dynamic anatomic imaging can be obtained with high isotropic 3D resolution. This approach is promising for diagnosis and treatment planning of vascular diseases and strokes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Auditory evoked field measurement using magneto-impedance sensors

The magnetic field of the human brain is extremely weak, and it is mostly measured and monitored in the magnetoencephalography method using superconducting quantum interference devices. In this study, in order to measure the weak magnetic field of the brain, we constructed a Magneto-Impedance sensor (MI sensor) system that can cancel out the background noise without any magnetic shield. Based on our previous studies of brain wave measurements, we used two MI sensors in this system for monitoring both cerebral hemispheres. In this study, we recorded and compared the auditory evoked field signals of the subject, including the N100 (or N1) and the P300 (or P3) brain waves. The results suggest that the MI sensor can be applied to brain activity measurement.

60 APPLIED LIFE SCIENCES↗

Performance of JT-60SA divertor Thomson scattering diagnostics

For the satellite tokamak JT-60 Super Advanced (JT-60SA), a divertor Thomson scattering measurement system is planning to be installed. In this study, we improved the design of the collection optics based on the previous one, in which it was found that the solid angle of the collection optics became very small, mainly because of poor accessibility to the measurement region. By improvement, the solid angle was increased by up to approximately five times. To accurately assess the measurement performance, background noise was assessed using the plasma parameters in two typical discharges in JT-60SA calculated from the SONIC code. Moreover, the influence of the reflection of bremsstrahlung radiation by the wall is simulated by using a ray tracing simulation. The errors in the temperature and the density are assessed based on the simulation results for three typical field of views.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE THOMSON SURFACE. I. REALITY AND MYTH

The solar corona and heliosphere are visible via sunlight that is Thomson-scattered off free electrons and detected by coronagraphs and heliospheric imagers. It is well known that these instruments are most responsive to material at the 'Thomson surface', the sphere with a diameter passing through both the observer and the Sun. It is less well known that in fact the Thomson scattering efficiency is minimized on the Thomson surface. Unpolarized heliospheric imagers such as STEREO/HI are thus approximately equally responsive to material over more than a 90 Degree-Sign range of solar exit angles at each given position in the image plane. We call this range of angles the 'Thomson plateau'. We observe that heliospheric imagers are actually more sensitive to material far from the Thomson surface than close to it, at a fixed radius from the Sun. We review the theory of Thomson scattering as applied to heliospheric imaging, feature detection in the presence of background noise, geometry inference, and feature mass measurement. We show that feature detection is primarily limited by observing geometry and field of view, that the highest sensitivity for detection of density features is to objects close to the observer, that electron surface density inference is independent of geometry across the Thomson plateau, and that mass inference varies with observer distance in all geometries. We demonstrate the sensitivity results with a few examples of features detected by STEREO, far from the Thomson surface.

79 ASTRONOMY AND ASTROPHYSICS↗

Understanding the LIGO GW150914 event

We present a simplified method for the extraction of meaningful signals from Hanford and Livingston 32 second data for the GW150914 event made publicly available by the LIGO collaboration, and demonstrate its ability to reproduce the LIGO collaboration's own results quantitatively given the assumption that all narrow peaks in the power spectrum are a consequence of physically uninteresting signals and can be removed. After the clipping of these peaks and return to the time domain, the GW150914 event is readily distinguished from broadband background noise. This simple technique allows us to identify the GW150914 event without any assumption regarding its physical origin and with minimal assumptions regarding its shape. We also confirm that the LIGO GW150914 event is uniquely correlated in the Hanford and Livingston detectors for the full 4096 second data at the level of 6–7 σ with a temporal displacement of τ = 6.9 ± 0.4 ms. We have also identified a few events that are morphologically close to GW150914 but less strongly cross correlated with it.

79 ASTRONOMY AND ASTROPHYSICS↗

Time-resolved single-photon detection module based on silicon photomultiplier: A novel building block for time-correlated measurement systems

We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm{sup 2} together with the suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to environment temperature variations, which represents a fundamental parameter to profitably use the instrument for real-field applications. We also characterized the single-photon timing resolution, the background noise due to both primary dark count generation and afterpulsing, the single-photon detection efficiency, and the instrument response function shape. The proposed module can become a reliable and cost-effective building block for time-correlated single-photon counting instruments in applications requiring high collection capability of isotropic light and detection efficiency (e.g., fluorescence decay measurements or time-domain diffuse optics systems).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlocal fluctuations and control of dimer entanglement dynamics

We report on the dissipative dynamics of an entangled, bipartite interacting system. We show how to induce and control the so-called early-stage disentanglement (and 'delayed' entanglement generation) dynamics by means of a driving laser field. We demonstrate that some of the features currently associated with pure non-Markovian effects in such entanglement behavior can actually take place in Markovian environments if background-noise quantum electrodynamics fluctuations are considered. We illustrate this for the case of a dimer interacting molecular system for which emission rates, interaction strength, and radiative corrections have been previously measured. We also show that even in the absence of collective decay mechanisms and qubit-qubit interactions, the entanglement still exhibits collapse-revival behavior. Our results indicate that zero-point energy fluctuations should be taken into account when formulating precise entanglement dynamics statements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bayesian coherent analysis of in-spiral gravitational wave signals with a detector network

The present operation of the ground-based network of gravitational-wave laser interferometers in enhanced configuration and the beginning of the construction of second-generation (or advanced) interferometers with planned observation runs beginning by 2015 bring the search for gravitational waves into a regime where detection is highly plausible. The development of techniques that allow us to discriminate a signal of astrophysical origin from instrumental artefacts in the interferometer data and to extract the full range of information are therefore some of the primary goals of the current work. Here we report the details of a Bayesian approach to the problem of inference for gravitational wave observations using a network (containing an arbitrary number) of instruments, for the computation of the Bayes factor between two hypotheses and the evaluation of the marginalized posterior density functions of the unknown model parameters. The numerical algorithm to tackle the notoriously difficult problem of the evaluation of large multidimensional integrals is based on a technique known as nested sampling, which provides an attractive (and possibly superior) alternative to more traditional Markov-chain Monte Carlo methods. We discuss the details of the implementation of this algorithm and its performance against a Gaussian model of the background noise, considering the specific case of the signal produced by the in-spiral of binary systems of black holes and/or neutron stars, although the method is completely general and can be applied to other classes of sources. We also demonstrate the utility of this approach by introducing a new coherence test to distinguish between the presence of a coherent signal of astrophysical origin in the data of multiple instruments and the presence of incoherent accidental artefacts, and the effects on the estimation of the source parameters as a function of the number of instruments in the network.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tomographic imaging system for measuring impurity line emission in a field-reversed configuration

A 16 chord optical tomography system has been developed and implemented in the flux coil generated-field reversed configuration (FRC). The chords are arranged in two fans of eight, which cover {approx}35% of the vessel area at the midplane. Each illuminate separate photomultiplier tubes (PMTs) which are fitted with narrow band-pass filters. In this case, filters are centered at 434.8 nm to measure emission from singly ionized argon. PMT crosstalk is negligible. Background noise due to electron radiation and H{sub {gamma}} line radiation is <10% of argon emission. The spatial resolution of the reconstruction is 1.5 cm. Argon is introduced using a puff valve and tube designed to impart the gas into the system as the FRC is forming. Reconstruction of experimental data results in time-dependent, 2D emissivity profiles of the impurity ions. Analysis of these data show radial, cross-field diffusion to be in the range of 10-10{sup 3} m{sup 2}/s during FRC equilibrium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface and material analytics based on Dresden-EBIS platform technology

Nowadays widely used mass spectrometry systems utilize energetic ions hitting a sample and sputter material from the surface of a specimen. The generated secondary ions are separated and detected with high mass resolution to determine the target materials constitution. Based on this principle, we present an alternative approach implementing a compact Electron Beam Ion Source (EBIS) in combination with a Liquid Metal Ion Source (LMIS). An LMIS can deliver heavy elements which generate high sputter yields on a target surface. More than 90% of this sputtered material consists of mono- and polyatomic neutrals. These particles are able to penetrate the magnetic field of an EBIS and they will be ionized within the electron beam. A broad spectrum of singly up to highly charged ions can be extracted depending on the operation conditions. Polyatomic ions will decay during the charge-up process. A standard bending magnet or a Wien filter is used to separate the different ion species due to their mass-to-charge ratio. Using different charge states of ions as it is common with EBIS it is also possible to resolve interfering charge-to-mass ratios of only singly charged ions. Different setups for the realization of feeding the electron beam with sputtered atoms of solids will be presented and discussed. As an example the analysis of a copper surface is used to show high-resolution spectra with low background noise. Individual copper isotopes and clusters with different isotope compositions can be resolved at equal atomic numbers. These results are a first step for the development of a new compact low-cost and high-resolution mass spectrometry system. In a more general context, the described technique demonstrates an efficient method for feeding an EBIS with atoms of nearly all solid elements from various solid target materials. The new straightforward design of the presented setup should be of high interest for a broad range of applications in materials research as well as for applications connected to analyzing the biosphere, hydrosphere, lithosphere, cosmosphere and technosphere.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantification of arterial plaque and lumen density with MDCT

Purpose: This study aimed to derive a mathematical correction function in order to normalize the CT number measurements for small volume arterial plaque and small vessel mimicking objects, imaged with multidetector CT (MDCT). Methods: A commercially available calcium plaque phantom (QRM GmbH, Moehrendorf, Germany) and a custom built cardiovascular phantom were scanned with 320 and 64 MDCT scanners. The calcium hydroxyapatite plaque phantom contained objects 0.5-5.0 mm in diameter with known CT attenuation nominal values ranging 50-800 HU. The cardiovascular phantom contained vessel mimicking objects 1.0-5.0 mm in diameter with different contrast media. Both phantoms were scanned using clinical protocols for CT angiography and images were reconstructed with different filter kernels. The measured CT number (HU) and diameter of each object were analyzed on three clinical postprocessing workstations. From the resultant data, a mathematical formula was derived based on absorption function exp(-{mu}{sup *}d) to demonstrate the relation between measured CT numbers and object diameters. Results: The percentage reduction in measured CT number (HU) for the group of selected filter kernels, apparent during CT angiography, is dependent only on the object size (plaque or vessel diameter). The derived formula of the form 1-c{sup *}exp(-a{sup *}d{sup b}) showed reduction in CT number for objects between 0.5 and 5 mm in diameter, with asymptote reaching background noise for small objects with diameters nearing the CT in-plane resolution (0.35 mm). No reduction was observed for the objects with diameters equal or larger than 5 mm. Conclusions: A clear mathematical relationship exists between object diameter and reduction in measured CT number in HU. This function is independent of exposure parameters and inherent attenuation properties of the objects studied. Future developments include the incorporation of this mathematical model function into quantification software in order to automatically generate a true assessment of measured CT number (HU) corresponding to plaque physical density {rho} (g/cm{sup 3}). This is a significant development for the accurate, noninvasive classification of noncalcified arterial plaque.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Wireless Transmission of Monitoring Data out of an Underground Repository: Results of Field Demonstrations Performed at the HADES Underground Laboratory - 13589

As part of the European 7. framework project MoDeRn, Nuclear Research and Consultancy Group (NRG) performed experiments in order to demonstrate the feasibility of wireless data transmission through the subsurface over large distances by low frequency magnetic fields in the framework of the geological disposal of radioactive waste. The main objective of NRG's contribution is to characterize and optimize the energy use of this technique within the specific context of post-closure monitoring of a repository. For that, measurements have been performed in the HADES Underground Research Laboratory (URL) located at Mol, Belgium, at 225 m depth. The experimental set-up utilizes a loop antenna for the transmitter that has been matched to the existing infrastructure of the HADES. Between 2010 and 2012 NRG carried out several experiments at the HADES URL in order to test the technical set-up and to characterize the propagation behavior of the geological medium and the local background noise pattern. Transmission channels have been identified and data transmission has been demonstrated at several frequencies, with data rates up to 10 bit/s and bit error rates <1%. A mathematical model description that includes the most relevant characteristics of the transmitter, transmission path, and receiver has been developed and applied to analyze possible options to optimize the set-up. With respect to the energy-efficiency, results so far have shown that data transmission over larger distances through the subsurface is a feasible option. To support the conclusions on the energy need per bit of transmitted data, additional experiments are foreseen. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fractal dynamics of light scattering intensity fluctuation in disordered dusty plasmas

Dynamic light scattering (DLS) technique is a simple and yet powerful technique for characterizing particle properties and dynamics in complex liquids and gases, including dusty plasmas. Intensity fluctuation in DLS experiments often studied using correlation analysis with assumption that the fluctuation is statistically stationary. In this study, the temporal variation of the nonstationary intensity fluctuation is analyzed directly to show the existence of fractal characteristics by employing wavelet scalogram approach. Wavelet based scale decomposition approach is used to separate non-scaling background noise (without dust) from scaling intensity fluctuation from dusty plasma. The Hurst exponents for light intensity fluctuation in dusty plasma at different neutral gas pressures are determined. At low pressures, weaker damping of dust motions via collisions with neutral gases results in stronger persistent behavior in the fluctuation of DLS time series. The fractal scaling Hurst exponent is demonstrated to be useful for characterizing structural phases in complex disordered dusty plasma, especially when particle configuration or sizes are highly inhomogeneous which makes the standard pair-correlation function difficult to interpret. The results from fractal analysis are compared with alternative interpretation of disorder based on approximate entropy and particle transport using mean square displacement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modification of a commercial cavity ring-down spectroscopy NO{sub 2} detector for enhanced sensitivity

Nitrogen dioxide (NO{sub 2}) plays a central role in atmospheric chemistry, air pollution, and biogeochemical cycles. Many analytical techniques have been developed to detect NO{sub 2}, but only chemiluminescence-based instruments are commonly, commercially available. There remains a need for a fast, light, and simple method to directly measure NO{sub 2}. In this work we describe the modification and characterization of a small, commercially available cavity ring-down spectroscopy (CRDS) NO{sub 2} detector suitable for surface and aircraft monitoring. A metal oxide scrubber was added to remove NO{sub 2}, and provide a chemical zero, improving the detection limit (3{sigma} of the background noise) from several parts per billion by volume (ppbv) to 0.06 ppbv, integrated over 60 s. Known interferences by water and particles were removed using Nafion tubing and a 1 {mu}m Teflon filter, respectively. A 95% response time of 18{+-}1 s was observed for a step change in concentration. The CRDS detector was run in parallel to an ozone chemiluminescence device with photolytic conversion of NO{sub 2} to NO. The two instruments measured ambient air in suburban Maryland. A least-squares fit to the comparison data resulted a slope of 0.960{+-}0.002 and R of 0.995, showing agreement within experimental uncertainty.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Testing a class of non-Kerr metrics with hot spots orbiting SgrA*

SgrA*, the supermassive black hole candidate at the Galactic Center, exhibits flares in the X-ray, NIR, and sub-mm bands that may be interpreted within a hot spot model. Light curves and images of hot spots orbiting a black hole are affected by a number of special and general relativistic effects, and they can be potentially used to check whether the object is a Kerr black hole of general relativity. However, in a previous study we have shown that the relativistic features are usually subdominant with respect to the background noise and the model-dependent properties of the hot spot, and eventually it is at most possible to estimate the frequency of the innermost stable circular orbit. In this case, tests of the Kerr metric are only possible in combination with other measurements. In the present work, we consider a class of non-Kerr spacetimes in which the hot spot orbit may be outside the equatorial plane. These metrics are difficult to constrain from the study of accretion disks and indeed current X-ray observations of stellar-mass and supermassive black hole candidates cannot put interesting bounds. Here we show that near future observations of SgrA* may do it. If the hot spot is sufficiently close to the massive object, the image affected by Doppler blueshift is brighter than the other one and this provides a specific observational signature in the hot spot's centroid track. We conclude that accurate astrometric observations of SgrA* with an instrument like GRAVITY should be able to test this class of metrics, except in the more unlikely case of a small viewing angle.

79 ASTRONOMY AND ASTROPHYSICS↗