Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Attack localization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Unsteady surface pressure distributions on a delta wing undergoing large amplitude pitching motions

Wind tunnel experiments were performed on a 70-deg-sweep delta wing to determine the effect of a sinusoidal pitching motion on the pressure field on the suction side of the wing. Pressure taps were placed from 35-90 percent of the chord, at 60 percent of the local semi-span. Pressure coefficients were measured as functions of Reynolds number and pitch rate. The surface pressure distribution was seen to vary at the same frequency as the pitching frequency, though distortion due to the vortex breakdown was observed. Comparing the upstroke (angle of attack increasing) and downstroke (angle of attack decreasing) pressures for a specific angle of attack, a time lag in the pressure distribution was observed. The downstroke pressures were slightly larger at the forward chord locations. Vortex breakdown was seen to have the most significant effect at the 40-45-percent chord location, where an increase in local pressure was apparent, as well as a distortion of the periodic pressure fluctuation.

Thompson, S. A.↗

A parallel trajectory optimization tool for aerospace plane guidance

A parallel trajectory optimization algorithm is being developed. One possible mission is to provide real-time, on-line guidance for the National Aerospace Plane. The algorithm solves a discrete-time problem via the augmented Lagrangian nonlinear programming algorithm. The algorithm exploits the dynamic programming structure of the problem to achieve parallelism in calculating cost functions, gradients, constraints, Jacobians, Hessian approximations, search directions, and merit functions. Special additions to the augmented Lagrangian algorithm achieve robust convergence, achieve (almost) superlinear local convergence, and deal with constraint curvature efficiency. The algorithm can handle control and state inequality constraints such as angle-of-attack and dynamic pressure constraints. Portions of the algorithm have been tested. The nonlinear programming core algorithm performs well on a variety of static test problems and on an orbit transfer problem. The parallel search direction algorithm can reduce wall clock time by a factor of 10 for this part of the computation task.

Psiaki, Mark L.↗

The Test and Evaluation of a Non-Chromate Finishing Agent

This research is focused on the design, development and implementation of an industry, military and commercial standard testing cell for surface coatings, which focuses on advanced non-chromate materials technology and their commercialization. Currently, within both private and commercial sectors, chromates are used in the corrosion prevention. processes. However, there is a great demand for chromate-free systems that are able to provide equal protection. At the end of this effort, it is intended that a patented alternative to chromate conversion coatings would be tested and processed for commercialization. Thus far, research studies have been concerned primarily with current corrosion knowledge and testing methods. Corrosion can be classified into five categories: The first type is uniform corrosion which is dominated by a uniform thinning due to an even and regular loss of metal. The second type is called localized corrosion in which most of the loss occurs in discrete areas. The third type, metallurgically influenced corrosion is a form of attack where metallurgy plays a significant role. The fourth type, titled mechanically assisted degradation is a form of attack where velocity, abrasion, and hydrodynamics control the corrosion process. The last type of corrosion is defined as environmentally induced cracking which occurs when cracks are produced under specific, premeditated stress. Oddly enough, with these varying classifications, there are not as many standardized corrosion testing sites. Two of the most common testing methods for corrosion are salt spray testing and filiform. Although neither has proven to be absolute, in terms of the resulting observations, our research aims to help provide data that may be used to support the standardization for corrosion testing. We would acquire and use a Singleton Cyclic Corrosion Testing Chamber. Singleton test chambers perform a wide range of commonly used catalytic corrosion tests. They are used throughout the industry, some of which are - automotive, aerospace, electronic and many more. In addition to this, Singleton test chambers are fully expandable to accommodate cyclic corrosion testing needs. Singleton chambers are also designed for complete compliance and conformity with ASTM (American Society for Testing and Materials), military and commercial standards.

Gulley, H.↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Local and Total Density Measurements in Ice Shapes

Preliminary measurements of local and total densities inside ice shapes were obtained from ice shapes grown in the NASA Glenn Research Tunnel for a range of glaze ice, rime ice, and mixed phase ice conditions on a NACA 0012 airfoil at 0 angle of attack. The ice shapes were removed from the airfoil and a slice of ice 3 mm thick was obtained using a microtome. The resulting samples were then x-rayed to obtain a micro-radiography, the film was digitized, and image processing techniques were used to extract the local and total density values.

Vargas, Mario↗

Overview and Commentary on Applying the Coordinated Vulnerability Disclosure Process to Photovoltaic System Devices

The rapid expansion of photovoltaic (PV) systems, particularly inverters, has introduced new cybersecurity challenges that threaten both local operations as well as the broader electrical grid’s stability. PV inverters, integrated into critical energy infrastructure are potential targets for cyber attacks due to vulnerabilities in firmware, remote access systems, and communication protocols. The Coordinated Vulnerability Disclosure (CVD) process, as defined by the Cybersecurity and Infrastructure Security Agency (CISA), provides a framework for identifying, reporting, and addressing these vulnerabilities in a transparent and collaborative manner. This report outlines the CVD process as it applies to PV systems, detailing the roles of key stakeholders, such as manufacturers, grid operators, and security researchers. The report also highlights specific challenges in managing vulnerabilities for new and legacy PV systems, which includes those introduced by insecure communications and third-party supply chain components. By adhering to the CVD process, the PV industry can mitigate cybersecurity risks, ensure regulatory compliance, and maintain consumer trust, while safeguarding the operational resilience of the energy grid. Ultimately, the effective coordination of vulnerability management is crucial for securing the future of PV systems within the critical electric grid infrastructure landscape.

14 SOLAR ENERGY↗

Application of Cyber-Informed Engineering for Protecting BESS

This white paper synthesizes an array of crucial grid services provided by BESS technology, assesses its architecture and communications, and presents a case study for analysis against the principles introduced by Cyber-Informed Engineering (CIE). Furthermore, in walking through the analysis, this paper presents a framework to evaluate risks and solutions when considering BESS components. Asset owners and buyers could perform this analysis to assess their BESS product implementations, alternative inverter-based resources (IBR), and energy management systems (EMS). Battery systems fulfill various roles contingent on the unique market demands and the specific challenges presented by regional grid infrastructures. These roles also vary due to the differing utility models for ownership and operation, which are adapted to meet regional and local capabilities and requirements. Concerns have been raised regarding the potential for adversaries to exploit knowledge of battery operational patterns to orchestrate decisive attacks. However, the security of operational data for these systems may not be the primary vulnerability, as much of this information is already well-understood within the community. Applying a modest degree of subject matter expertise can often yield valuable predictions regarding how a battery will respond under certain conditions, such as grid emergencies, high or low-temperature days, Public Safety Power Shutoff (PSPS) events, and outages. The operational characteristics of batteries are well-documented, and their capabilities, including the risks associated with misoperation and the resulting consequences, are published and understood within the industry. CIE practices represent the next step in gaining functional assurance and providing an acceptable level of risk, regardless of whether a battery vendor can support a trusted and validated supply chain. While this issue has exacerbated supply chain challenges, it is not an isolated condition. This foreign supply route is the primary source of BESS for the U.S. market. Significant efforts are underway through the Bipartisan Infrastructure Law (BIL) to change that. Still, strategic short-term operational mitigations are needed to ensure the security of our operational technology (OT) systems, which are enhanced by instilling trust and are separate from vendors implementing CIE principles.

25 ENERGY STORAGE↗

Aeroacoustic Measurements of a Wing-Flap Configuration

Aeroacoustic measurements are being conducted to investigate the mechanisms of sound generation in high-lift wing configurations, and initial results are presented. The model is approximately 6 percent of a full scale configuration, and consists of a main element NACA 63(sub 2) - 215 wing section and a 30 percent chord half-span flap. Flow speeds up to Mach 0.17 are tested at Reynolds number up to approximately 1.7 million. Results are presented for a main element at a 16 degree angle of attack, and flap deflection angles of 29 and 39 degrees. The measurement systems developed for this test include two directional arrays used to localize and characterize the noise sources, and an array of unsteady surface pressure transducers used to characterize wave number spectra and correlate with acoustic measurements. Sound source localization maps show that locally dominant noise sources exist on the flap-side edge. The spectral distribution of the noise sources along the flap-side edge shows a decrease in frequency of the locally dominant noise source with increasing distance downstream of the flap leading edge. Spectra are presented which show general spectral characteristics of Strouhal dependent flow-surface interaction noise. However, the appearance of multiple broadband tonal features at high frequency indicates the presence of aeroacoustic phenomenon following different scaling characteristics. The scaling of the high frequency aeroacoustic phenomenon is found to be different for the two flap deflection angles tested. Unsteady surface pressure measurements in the vicinity of the flap edge show high coherence levels between adjacent sensors on the flap-side edge and on the flap edge upper surface in a region which corresponds closely to where the flap-side edge vortex begins to spill over to the flap upper surface. The frequency ranges where these high levels of coherence occur on the flap surface are consistent with the frequency ranges in which dominant features appear in far field acoustic spectra. The consistency of strongly correlated unsteady surface pressures and far field pressure fluctuations suggests the importance of regions on the flap edge in generating sound.

Meadows, Kristine R.↗

A modification to linearized theory for prediction of pressure loadings on lifting surfaces at high supersonic Mach numbers and large angles of attack

A new linearized-theory pressure-coefficient formulation was studied. The new formulation is intended to provide more accurate estimates of detailed pressure loadings for improved stability analysis and for analysis of critical structural design conditions. The approach is based on the use of oblique-shock and Prandtl-Meyer expansion relationships for accurate representation of the variation of pressures with surface slopes in two-dimensional flow and linearized-theory perturbation velocities for evaluation of local three-dimensional aerodynamic interference effects. The applicability and limitations of the modification to linearized theory are illustrated through comparisons with experimental pressure distributions for delta wings covering a Mach number range from 1.45 to 4.60 and angles of attack from 0 to 25 degrees.

Carlson, H. W.↗

On the Feasibility of Market Manipulation and Energy Storage Arbitrage via Load-Altering Attacks

Around the globe, electric power networks are transforming into complex cyber–physical energy systems (CPES) due to the accelerating integration of both information and communication technologies (ICT) and distributed energy resources. While this integration improves power grid operations, the growing number of Internet-of-Things (IoT) controllers and high-wattage appliances being connected to the electric grid is creating new attack vectors, largely inherited from the IoT ecosystem, that could lead to disruptions and potentially energy market manipulation via coordinated load-altering attacks (LAAs). In this article, we explore the feasibility and effects of a realistic LAA targeted at IoT high-wattage loads connected at the distribution system level, designed to manipulate local energy markets and perform energy storage (ES) arbitrage. Realistic integrated transmission and distribution (T&D) systems are used to demonstrate the effects that LAAs have on locational marginal prices at the transmission level and in distribution systems adjacent to the targeted network.

25 ENERGY STORAGE↗

A Randomization-Based, Zero-Trust Cyberattack Detection Method for Hierarchical Systems

This paper demonstrates a novel randomization-based approach for verifying power system control signals with application to detecting cyberattacks. We consider fully connected hierarchical systems containing multiple local agents and a global "trust" agent. The global agent uses a time-varying randomized assignment scheme to identify corrupt network links based on principles of zero trust and majority rule. To evaluate the performance of this detection approach, we implement our algorithm in MATLAB and run it against nearly 43 million unique attack scenarios spanning a range of system sizes. For each scenario, the algorithm determines whether the identified corruptions satisfy a set of validity constraints reflecting network topology and uses that result to say whether the recovered state value for one or more local agents is malicious. We compare the algorithm's determination to the true state of the system to assess performance and find that classification accuracy converges to 100% as system size increases, suggesting that the validity constraints become more difficult to satisfy for larger systems. We further explore the scenarios that evade detection to understand practical implications for employing this detection approach.

cybersecurity↗

Multi-Source Data Aggregation and Real-Time Anomaly Classification and Localization in Power Distribution Systems

This paper proposes a real-time anomaly location and classification framework for power distribution systems to simultaneously determine the type of anomaly (i.e., short-circuit fault, cyber attack, DER switching) and its location. The proposed framework employs the data aggregation module to collect the measurement data from multiple field devices operating at different sampling rates, such as protection relays and D-PMUs. The output of the data aggregation is then fed into a multi-task learning-based long-based short-term memory (MTL-LSTM) to classify the type of anomaly and the location in two separate tasks. The proposed MTL-LSTM approach can be utilized in real-time operation in order to distinguish between normal and several anomalous operations and locate the anomaly. The proposed framework is tested on a modified IEEE 33-bus test feeder benchmark that integrates solar generation and energy storage. Furthermore, the results show that the proposed framework can locate and classify anomalies for several operation conditions with more than 96% accuracy. Further experiments highlight the impact of aggregating multiple sources of data on the performance of the proposed model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Localized Cyber Threat Mitigation Approach For Wide Area Control of FACTS

We propose a localized oscillation amplitude monitoring (OAM) method for the mitigation of cyber threats directed at the wide area control (WAC) system used to coordinate control of Flexible AC Transmission Systems (FACTS) for power oscillation damping (POD) of active power flow on inter-area tie lines. The method involves monitoring the inter-area tie line active power oscillation amplitude over a sliding window. We use system instability - inferred from oscillation amplitudes growing instead of damping - as evidence of an indication of a malfunction in the WAC of FACTS, possibly indicative of a cyber attack. Monitoring the presence of such a growth allows us to determine whether any destabilizing behaviors appear after the WAC system engages to control the POD. If the WAC signal increases the oscillation amplitude over time, thereby diminishing the POD performance, the FACTS falls back to POD using local measurements. The proposed method does not require an expansive system-wide view of the network. We simulate replay, control integrity, and timing attacks for a test system and present results that demonstrate the performance of the OAM method for mitigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Local carbon reserves are insufficient for phloem terpene induction during drought in Pinus edulis in response to bark beetle–associated fungi

Stomatal closure during drought inhibits carbon uptake and may reduce a tree's defensive capacity. Limited carbon availability during drought may increase a tree's mortality risk, particularly if drought constrains trees' capacity to rapidly produce defenses during biotic attack. We parameterized a new model of conifer defense using physiological data on carbon reserves and chemical defenses before and after a simulated bark beetle attack in mature Pinus edulis under experimental drought. Attack was simulated using inoculations with a consistent bluestain fungus (Ophiostoma sp.) of Ips confusus, the main bark beetle colonizing this tree, to induce a defensive response. Trees with more carbon reserves produced more defenses but measured phloem carbon reserves only accounted for c. 23% of the induced defensive response. Our model predicted universal mortality if local reserves alone supported defense production, suggesting substantial remobilization and transport of stored resin or carbon reserves to the inoculation site. Our results show that de novo terpene synthesis represents only a fraction of the total measured phloem terpenes in P. edulis following fungal inoculation. Without direct attribution of phloem terpene concentrations to available carbon, many studies may be overestimating the scale and importance of de novo terpene synthesis in a tree's induced defense response.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of reaction control system jet simulation on the stability and control characteristics of a 0.015-scale space shuttle orbiter model in the Ames Research Center 3.5-foot hypersonic wind tunnel

An experimental investigation was performed in the Ames Research Center 3.5-Foot Hypersonic Wind Tunnel to obtain detailed effects which interactions between the RCS jet flow field and the local orbiter flow field have on orbiter hypersonic stability and control characteristics. Six-component force data were obtained through an angle-of-attack range of 15 to 35 deg with 0 deg angle of sideslip. The test was conducted with yaw, pitch and roll jet simulation at a free-stream Mach number of 10.3. These data simulate two SSV reentry flight conditions at Mach numbers of 28.3 and 10.3. Fuselage base pressures and pressures on the nonmetric RCS pods were obtained in addition to the basic force measurements. Model 42-0 was used for these tests.

Dziubala, T. J.↗

Effect of oxidation on the mechanical properties of a NbAl3 alloy at intermediate temperatures

The effect of environment on the mechanical properties of an Nb-67Al-7Cr-0.25W-0.5Y alloy was investigated experimentally in the temperature range 800-1200 K. It is found that the severity of environmental attack in the alloy is determined by both matrix plasticity and oxidation kinetics. The former determines the ability of the matrix to accommodate the localized stresses generated during deformation and oxidation, while the latter governs the rate of formation of a protective oxide scale. The environmental degradation of the alloy can thus be reduced or eliminated by increasing atomic mobility.

Raj, S. V.↗

Effects of Cone Angle, Mach Number, and Nose Blunting on Transition at Supersonic Speeds

An investigation has been made to determine the transition characteristics of a group of blunt cones which varied in included apex angle from 27 deg to 60 deg over a Mach number range from 1.61 to 2.20 and a range of tunnel Reynolds number per foot from about 1.5 x 10(exp 6) to 8.0 x 10(exp 6). The tests were made at zero angle of attack and with zero heat transfer. The results indicate that the general level of transition Reynolds number based on boundary-layer momentum thickness and local flow conditions just outside the boundary layer varied between 600 and 1,100. Changes in Mach number had little effect on transition distance and transition Reynolds number for the near-sharp or very small bluntnesses. The effect of Mach number variation on the larger hemispherical bluntnesses was much stronger, with the strongest Mach number effect occurring for Mach numbers between 1.61 and 1.82. With an increase in nose radius, there was a strong decrease in transition distance and transition Reynolds number at the lower Mach numbers. This adverse effect tended to become weaker with increase in Mach number. An increase in cone angle at a constant Mach number caused a reduction in transition distance and transition Reynolds number for the blunt configurations which had approximately the same values of nose radius.

Czarnecki, K. R.↗

Comparing Methods to Extract Sectional Angle of Attack From Blade-Resolved Rotor Simulations

The angle of attack is widely used to describe the aerodynamics of rotor blades. Models based on lifting lines, actuator lines, and actuator disks use it as a primary variable, assuming the aerodynamics can be represented by the flow around a collection of equivalent 2D airfoils. This paper evaluates the accuracy of existing methods that extract the angle of attack from blade-resolved CFD simulations, towards enabling a direct comparison of angle of attack between blade-resolved and blade-modeled simulations. Results are compared for a 2D airfoil for which the angle of attack is known by definition. The hovering rotor case is also considered, where we look at two different rotor blades. We discuss the factors that impact the accuracy of the 2D predictions. For the 3D rotors, we show that three-dimensional effects in the root and tip regions lead to large discrepancies between methods. This suggests that the very definition of angle of attack is unable to accurately represent the flow in these regions. Finally, based on guidelines that we establish, we propose an alternate method that uses local velocities sampled on a contour located 0.25 chord, or less, away from the airfoil surface and generally yields improved accuracy compared to most existing techniques.

ARMD↗