Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANESTHETICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Thermoregulatory responses of rats to varying environmental temperatures

The peripheral (tail) circulatory responses of six male albino rats were measured at ambient temperatures between 5 and 40 C, using impedance plethysmography. Each animal was anesthetized, instrumented, and placed in a thermal environmental chamber to reach equilibrium. Tail blood flow, respiration rate, heart rate, core temperature, and tail skin temperature were then monitored at each ambient temperature. The mean tail blood flow was significantly higher (p less than 0.05) at 5 C than at 10 C. The mean blood flow increased significantly (p less than 0.01) at each of the temperatures above 10 C. Tail skin temperature and internal body (core) temperature increased significantly with increasing ambient temperature.

Berry, J. J.↗

Circadian Rhythm Control: Neurophysiological Investigations

The suprachiasmatic nucleus (SCN) was implicated as a primary component in central nervous system mechanisms governing circadian rhythms. Disruption of the normal synchronization of temperature, activity, and other rhythms is detrimental to health. Sleep wake disorders, decreases in vigilance and performance, and certain affective disorders may result from or be exacerbated by such desynchronization. To study the basic neurophysiological mechanisms involved in entrainment of circadian systems by the environment, Parylene-coated, etched microwire electrode bundles were used to record extracellular action potentials from the small somata of the SCN and neighboring hypothalamic nuclei in unanesthetized, behaving animals. Male Wistar rats were anesthetized and chronically prepared with EEG ane EMG electrodes in addition to a moveable microdrive assembly. The majority of cells had firing rates 10 Hz and distinct populations of cells which had either the highest firing rate or lowest firing rate during sleep were seen.

Glotzbach, S. F.↗

Transpulmonary passage of venous air emboli

Twenty-seven paralyzed anesthetized dogs were embolized with venous air to determine the effectiveness of the pulmonary vasculature for bubble filtration or trapping. Air doses ranged from 0.05 to 0.40 ml/kg min in 0.05-ml increments with ultrasonic Doppler monitors placed over arterial vessels to detect any microbubbles that crossed the lungs. Pulmonary vascular filtration of the venous air infusions was complete for the lower air doses ranging from 0.05 to 0.30 ml/kg min. When the air doses were increased to 0.35 ml/kg min, the filtration threshold was exceeded with arterial spillover of bubbles occurring in 50 percent of the animals and reaching 71 percent for 0.40 ml/kg min. Significant elevations were observed in pulmonary arterial pressure and pulmonary vascular resistance. Systemic blood pressure and cardiac output decreased, whereas left ventricular end-diastolic pressure remained unchanged. The results indicate that the filtration of venous bubbles by the pulmonary vasculature was complete when the air infusion rates were kept below a threshold value of 0.30 ml/kg min.

Butler, B. D.↗

Gravitational independence of single-breath washout tests in recumbent dogs

The effect of gravitational orientation in the mechanism of lung filling and emptying in dogs was examined by conducting simultaneously Ar-bolus and N2 single-breath washout tests (SBWTs) in 10 anesthetized dogs (prone and supine), with three of the dogs subjected to body rotation. Transpulmonary pressure was measured simultaneously, allowing identification of the lung volume above residual volume at which there was an inflection point in the pressure-volume curve. Combined resident gas and bolus SBWTs in recumbent dogs were found to be different from such tests in humans; in dogs, the regional distribution of ventilation was not primarily determined by gravity. The measurements did not make it possible to discern exact mechanisms of filling and emptying, but both processes appear to be related to lung, thorax, and mediastinum interactions and/or differences in regional mechanical properties of the lungs.

Tomioka, Shinichi↗

Effect of the Trendelenburg position on the distribution of arterial air emboli in dogs

The effect of Trendelenburg position (TP) on the distribution of arterial air emboli in dogs was examined in a two-part investigation. In the first part, the effects of the bubble size and the vessel angle on the bubble velocity and the direction of flow were investigated in vitro, using a simulated carotid artery preparation. It was found that larger bubbles increased in velocity in the same direction as the blood flow at 0-, 10-, and 30-deg vessel angles, and decreased when the vessel was positioned at 90 deg. Smaller bubbles did not change velocity from 0 to 30 deg, but acted to increase the velocity, in the same direction as the flood flow, at 90 deg. The second series of experiments examined the effect of 0 to 30 deg TP on carotid-artery distribution of gas bubbles injected into the left ventricle or ascending aorta of anesthetized dogs. It was found that, regardless of the degree of the TP, the bubbles passed into the carotid artery simultaneously with the passage into the abdominal aorta. It is concluded that the TP does not prevent arterial bubbles from reaching the brain.

Butler, Bruce D.↗

Vascular pressures and passage of gas emboli through the pulmonary circulation

Doppler technique was used to measure the pulmonary vascular pressure gradients in dogs that received venous air emboli (VAE) at the rate of 0.35 ml/kg per min, at which the spillover of bubbles into the systemic arteries occur. It was found that, in 60 percent of dogs, venous bubbles spilled over into the arterial circulation at the pulmonary vascular pressure gradient of about 34.7 mm Hg. When the pulmonary vascular pressure gradient was raised to about 52 mm Hg, the spillover of venous bubbles occurred 100 percent of time. It is concluded that venous bubbles can cross the lungs of anesthetized dogs when the driving pressures are sufficient to overcome the normal filtering function.

Butler, B. D.↗

Coexistence of twitch potentiation and tetanic force decline in rat hindlimb muscle

The effect of whole-muscle fatigue on the isometric twitch was investigated in various hindlimb muscles of anesthetized rats, using an experimental protocol designed to assess the levels of fatigability in motor units. The results of EMG and force measurements revealed the existence of a linear relationship between fatigability and the magnitude of the twitch force following the fatigue test in both soleus and extensor digitorum longus muscles.

Rankin, Lucinda L.↗

Projections from the rostral mesencephalic reticular formation to the spinal cord - An HRP and autoradiographical tracing study in the cat

Horseradish peroxidase was injected, or implanted unilaterally, into various levels of the spinal cord of anesthetized cats, to trace the distribution of projections to the spinal cord, of neurons in Field H of Forel, including the rostral interstitial nucleus of the medial longitudinal fasciculus (riMLF), and the interstitial nucleus of Cajal with adjacent reticular formation (INC-RF). Results indicate that, unlike the neurons projecting to the extraocular muscle motoneurons, the major portion of the spinally projecting neurons are not located in the riMLF or INC proper, but in adjacent areas, i.e., the ventral and lateral parts of the caudal third of the Field H of Forel and in the INC-RF. Neurons in caudal Field H of Forel, project, via the ventral part of the ventral funicululs, to the lateral part of the upper cervical ventral horn.

Holstege, G.↗

Effect of lysophosphatidylcholine on the filtration coefficient in intact dog lungs

Lysophosphatidylcholine (lyso-Pc) is a lysophospholipid normally found in low concentrations in the lung. At high concentrations lyso-Pc, instilled into the airways, causes pulmonary edema. The hypothesis was tested that the edema caused by lyso-Pc was due to an increase in pulmonary microvascular membrane permeability. In 11 anesthetized dogs, the left lower lobes (LLL) were continuously weighed while lyso-Pc (20 mM) was instilled into the LLL airways. After 30 min, the microvascular membrane fluid filtration coefficient (Kf) was determined from the relationship between the rate of LLL weight gain and the pulmonary microvascular pressure. Kf was not significantly different between the lyso-Pc-treated lobes vs control lobes. The data do not support the hypothesis that lyso-Pc, instilled into the airways, causes an increase in pulmonary microvascular permeability.

Butler, B. D.↗

The transfer of technology to measure skin burn depth in humans

Discussed here is the use of ultrasonic techniques originally used to locate cracks in metal structues to measure burn wound depth in humans. Acoustic impedance, performance tests, and the theoretical model are discussed. Measurements of skin burns on anesthetized pigs made with the the ultrasonic instrumentation were in agreement with diagnoses made by a physician, and subsequently confirmed by the healing process. Researchers felt that the concept proved useful in a clinical setting and that the instrument and concept were ready to extend to the manufacturer.

Yost, William T.↗

Doppler detection of decompression bubbles with computer assisted digitization of ultrasonic signals

The use of an inexpensive, commercially available audio digitizer in conjunction with a PC to digitize Doppler bubble signals for visual and electronic evaluation is reported. This device can be operated simultaneously with Doppler audio monitoring. Precordial and arterial Doppler recordings of gas bubbles were obtained from anesthetized dogs after intravascular infusion or following decompression. Additional evaluations were conducted on Doppler bubble recordings obtained from human decompression studies. The device can be used in real-time or for later signal analysis. Accompanying menu-driven software provides for numerous signal modification options and visual displays. This device can provide a simultaneous visual display of Doppler signals normally available only for audio evaluation.

Butler, B. D.↗

Comparison of dermal and inhalation routes of entry for organic chemicals

The quantitative comparison of the chemical concentration inside the body as the result of a dermal exposure versus an inhalation exposure is useful for assessing human health risks and deciding on an appropriate protective posture. In order to describe the relationship between dermal and inhalation routes of exposure, a variety of organic chemicals were evaluated. The types of chemicals chosen for the study were halogenated hydrocarbons, aromatic compounds, non-polar hydrocarbons and inhalation anesthetics. Both dermal and inhalation exposures were conducted in rats and the chemicals were in the form of vapors. Prior to the dermal exposure, rat fur was closely clipped and during the exposure rats were provided fresh breathing air through latex masks. Blood samples were taken during 4-hour exposures and analyzed for the chemical of interest. A physiologically based pharmacokinetic model was used to predict permeability constants (cm/hr) consistent with the observed blood concentrations of the chemical. The ratio of dermal exposure to inhalation exposure required to achieve the same internal dose of chemical was calculated for each test chemical. The calculated ratio in humans ranged from 18 for styrene to 1180 for isoflurane. This methodology can be used to estimate the dermal exposure required to reach the internal dose achieved by a specific inhalation exposure. Such extrapolation is important since allowable exposure standards are often set for inhalation exposures, but occupational exposures may be dermal.

Jepson, Gary W.↗

Micromotional studies of utricular and canal afferents

The long-range goal of this research was to refine our understanding of the sensitivity of the vestibular components of the ear to very-low-amplitude motion, especially, the role of gravity in this sensitivity. We focused on the American bullfrog--a common animal subject for vestibular sensory research. Our principal experimental method was to apply precise, sinusoidal microrotational stimuli to an anesthetized animal subject, to record the resulting responses in an individual vestibular nerve fiber from the intact ear, and to use intracellular dye to trace the fiber and thus identify the vestibular sensor that gave rise to it. In this way, we were able to identify specific micromotional sensitivities and to associate those sensitivities definitely with specific sensors. Furthermore, by recording from nerve fibers after they leave the intact inner-ear cavity, we were able to achieve these identifications without interrupting the delicate micromechanics of the inner ear. We were especially concerned with the relative roles of the utricle and the anterior semicircular canal in the sensing of microrotational motion of the head about horizontal axes, and with the role of gravity in mediating that sensing process in the utricle. The functional characterization of individual nerve fibers was accomplished with a conventional analytical tool, the cycle histogram, in which the nerve impulse rate was plotted against the phase of the sinusoidal stimulus.

Lewis, Edwin R.↗

Eccentric exercise training as a countermeasure to non-weight-bearing soleus muscle atrophy

This investigation tested whether eccentric resistance training could prevent soleus muscle atrophy during non-weight bearing. Adult female rats were randomly assigned to either weight bearing +/- intramuscular electrodes or non-weight bearing +/- intramuscular electrodes groups. Electrically stimulated maximal eccentric contractions were performed on anesthetized animals at 48-h intervals during the 10-day experiment. Non-weight bearing significantly reduced soleus muscle wet weight (28-31 percent) and noncollagenous protein content (30-31 percent) compared with controls. Eccentric exercise training during non-weight bearing attenuated but did not prevent the loss of soleus muscle wet weight and noncollagenous protein by 77 and 44 percent, respectively. The potential of eccentric exercise training as an effective and highly efficient counter-measure to non-weight-bearing atrophy is demonstrated in the 44 percent attenuation of soleus muscle noncollagenous protein loss by eccentric exercise during only 0.035 percent of the total non-weight-bearing time period.

Kirby, Christopher R.↗

Alanine increases blood pressure during hypotension

The effect of L-alanine administration on blood pressure (BP) during haemorrhagic shock was investigated using anesthetized rats whose left carotid arteries were cannulated for BP measurement, blood removal, and drug administration. It was found that L-alanine, in doses of 10, 25, 50, 100, and 200 mg/kg, increased the systolic BP of hypotensive rats by 38 to 80 percent (while 100 mg/kg pyruvate increased BP by only 9.4 mmhg, not significantly different from saline). The results suggest that L-alanine might influence cardiovascular function.

Conlay, L. A.↗

Grounding explanations in evolving, diagnostic situations

Certain fields of practice involve the management and control of complex dynamic systems. These include flight deck operations in commercial aviation, control of space systems, anesthetic management during surgery or chemical or nuclear process control. Fault diagnosis of these dynamic systems generally must occur with the monitored process on-line and in conjunction with maintaining system integrity.This research seeks to understand in more detail what it means for an intelligent system to function cooperatively, or as a 'team player' in complex, dynamic environments. The approach taken was to study human practitioners engaged in the management of a complex, dynamic process: anesthesiologists during neurosurgical operations. The investigation focused on understanding how team members cooperate in management and fault diagnosis and comparing this interaction to the situation with an Artificial Intelligence(AI) system that provides diagnoses and explanations. Of particular concern was to study the ways in which practitioners support one another in keeping aware of relevant information concerning the state of the monitored process and of the problem solving process.

Johannesen, Leila J.↗

Intrapericardial denervation: Responses to water immersion in rhesus monkeys

Eleven anesthetized rhesus monkeys were used to study cardiovascular, renal, and endocrine alterations associated with 120 min of head-out water immersion. Five animals underwent complete intrapericardial denervation using the Randall technique, while the remaining six monkeys served as intact controls. Each animal was chronically instrumented with an electromagnetic flow probe on the ascending aorta, a strain gauge pressure transducer implanted in the apex of the left ventricle (LV), and electrocardiogram leads anchored to the chest wall and LV. During immersion, LV end-diastolic pressure, urine flow, glomerular filtration rate, sodium excretion, and circulating atrial natriuretic peptide (ANP) each increased (P less than 0.05) for intact and denervated monkeys. There were no alterations in free water clearance in either group during immersion, yet fractional excretion of free water increased (P less than 0.05) in the intact monkeys. Plasma renin activity (PRA) decreased (P less than 0.05) during immersion in intact monkeys but not the denervated animals. Plasma vasopressin (PVP) concentration decreased (P less than 0.05) during the first 30 min of immersion in both groups but was not distinguishable from control by 60 min of immersion in denervated monkeys. These data demonstrate that complete cardiac denervation does not block the rise in plasma ANP or prevent the natriuresis associated with head-out water immersion. The suppression of PVP during the first minutes of immersion after complete cardiac denervation suggests that extracardiac sensing mechanisms associated with the induced fluid shifts may be responsible for the findings. water immersion; natriuresis; vasopressin; eardiae denervation; monkey

McKeever, Kenneth H.↗

Transesophageal Echocardiographic Study of Decompression-Induced Venous Gas Emboli

Transesophageal echo-cardiography was used to evaluate venous bubbles produced in nine anesthetized dogs following decompression from 2.84 bar after 120 min at pressure. In five dogs a pulsed Doppler cuff probe was placed around the inferior vena cava for bubble grade determination. The transesophageal echo images demonstrated several novel or less defined events. In each case where the pulmonary artery was clearly visualized, the venous bubbles were seen to oscillate back and forth several times, bringing into question the effect of coincidental counting in routine bubble grade analysis using precordial Doppler. A second finding was that in all cases, extensive bubbling occurred in the portal veins with complete extraction by the liver sinusoids, with one exception where a portal-to-hepatic venous anastomosis was observed. Compression of the bowel released copious numbers of bubbles into the portal veins, sometimes more than were released into the inferior vena cava. Finally, large masses of foam were routinely observed in the non-dependent regions of the inferior vena cava that not only delayed the appearance of bubbles in the pulmonary artery but also allowed additional opportunity for further reaction with blood products and for coalescence to occur before reaching the pulmonary microcirculation. These novel observations are discussed in relation to the decompression process.

Butler, B. D.↗