Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ANDERSON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Anderson localization and Brewster anomalies in photonic disordered quasiperiodic lattices

A comprehensive study of the properties of light propagation through one-dimensional photonic disordered quasiperiodic superlattices, composed of alternating layers with random thicknesses of air and a dispersive metamaterial, is theoretically performed. The superlattices consist of the successive stacking of N quasiperiodic Fibonacci or Thue-Morse heterostructures. The width of the slabs in the photonic superlattice may randomly fluctuate around its mean value, which introduces a structural disorder into the system. It is assumed that the left-handed layers have a Drude-type dispersive response for both the dielectric permittivity and magnetic permeability, and Maxwell's equations are solved for oblique incidence by using the transfer-matrix formalism. The influence of both quasiperiodicity and structural disorder on the localization length and Brewster anomalies are thoroughly discussed.

36 MATERIALS SCIENCE↗

Interplay between Anderson and Stark Localization in 2D Lattices

This Letter studies the dynamics of a quantum particle in 2D lattices with on-site disorder in the presence of a static field. It is shown that the particle is localized along the field direction, while in the orthogonal direction to the field it shows diffusive dynamics for algebraically large times. For weak disorder an analytical expression for the diffusion coefficient is obtained by mapping the problem to a band random matrix. This expression is confirmed by numerical simulations of the particle's dynamics, which also indicate the existence of a universal equation for the diffusion coefficient, valid for an arbitrary disorder strength.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Predicted Mobility Edges in One-Dimensional Incommensurate Optical Lattices: An Exactly Solvable Model of Anderson Localization

Localization properties of noninteracting quantum particles in one-dimensional incommensurate lattices are investigated with an exponential short-range hopping that is beyond the minimal nearest-neighbor tight-binding model. Energy dependent mobility edges are analytically predicted in this model and verified with numerical calculations. The results are then mapped to the continuum Schroedinger equation, and an approximate analytical expression for the localization phase diagram and the energy dependent mobility edges in the ground band is obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anderson Localization of Composite Particles

In this work, we investigate the effect of coupling between translational and internal degrees of freedom of composite quantum particles on their localization in a random potential. We show that entanglement between the two degrees of freedom weakens localization due to the upper bound imposed on the inverse participation ratio by purity of a quantum state. We perform numerical calculations for a two-particle system bound by a harmonic force in a 1D disordered lattice and a rigid rotor in a 2D disordered lattice. We illustrate that the coupling has a dramatic effect on localization properties, even with a small number of internal states participating in quantum dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Separate Surface and Bulk Topological Anderson Localization Transitions in Disordered Axion Insulators

In topological phases of matter for which the bulk and boundary support distinct electronic gaps, there exists the possibility of decoupled mobility gaps in the presence of disorder. This is in analogy with the well-studied problem of realizing separate or concomitant bulk-boundary criticality in conventional Landau theory. Using a three-dimensional axion insulator having clean, gapped surfaces with 𝑒 2 /2⁢ℎ quantized Hall conductance, we show that the bulk and surface mobility gap evolve differently in the presence of disorder. The decoupling of the bulk and surface topology yields a regime that realizes a two-dimensional, unquantized anomalous Hall metal in the Gaussian unitary ensemble on each surface, which shares some spectral and response properties akin to the surface states of a conventional 3D topological insulator. The generality of these results, as well as extensions to other insulators and superconductors, is discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Commissioning of the discrete spot scanning proton beam delivery system at University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston

Purpose: To describe a summary of the clinical commissioning of the discrete spot scanning proton beam at the Proton Therapy Center, Houston (PTC-H). Methods: Discrete spot scanning system is composed of a delivery system (Hitachi ProBeat), an electronic medical record (Mosaiq V 1.5), and a treatment planning system (TPS) (Eclipse V 8.1). Discrete proton pencil beams (spots) are used to deposit dose spot by spot and layer by layer for the proton distal ranges spanning from 4.0 to 30.6 g/cm{sup 2} and over a maximum scan area at the isocenter of 30x30 cm{sup 2}. An arbitrarily chosen reference calibration condition has been selected to define the monitor units (MUs). Using radiochromic film and ion chambers, the authors have measured spot positions, the spot sizes in air, depth dose curves, and profiles for proton beams with various energies in water, and studied the linearity of the dose monitors. In addition to dosimetric measurements and TPS modeling, significant efforts were spent in testing information flow and recovery of the delivery system from treatment interruptions. Results: The main dose monitors have been adjusted such that a specific amount of charge is collected in the monitor chamber corresponding to a single MU, following the IAEA TRS 398 protocol under a specific reference condition. The dose monitor calibration method is based on the absolute dose per MU, which is equivalent to the absolute dose per particle, the approach used by other scanning beam institutions. The full width at half maximum for the spot size in air varies from approximately 1.2 cm for 221.8 MeV to 3.4 cm for 72.5 MeV. The measured versus requested 90% depth dose in water agrees to within 1 mm over ranges of 4.0-30.6 cm. The beam delivery interlocks perform as expected, guarantying the safe and accurate delivery of the planned dose. Conclusions: The dosimetric parameters of the discrete spot scanning proton beam have been measured as part of the clinical commissioning program, and the machine is found to function in a safe manner, making it suitable for patient treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-D-BRA-06: IMRT QA with ArcCHECK: The MD Anderson Experience

Purpose: The objective of this project was to report our initial IMRT QA results and experience with the SunNuclear ArcCHECK. Methods: Three thousand one-hundred and sixteen cases were treated with IMRT or VMAT at our institution between October 2013 and September 2014. All IMRT/VMAT treatment plans underwent Quality Assurance (QA) using ArcCHECK prior to therapy. For clinical evaluation, a Gamma analysis is performed following QA delivery using the SNC Patient software (Sun Nuclear Corp) at the 3%/3mm level. QA Gamma pass rates were analyzed based on categories of treatment site, technique, and type of MLCs. Our current clinical threshold for passing a QA (Tclin) is set at a Gamma pass rate greater than 90%. We recorded the percent of failures for each category, as well as the Gamma pass rate threshold that would Result in 95% of QAs to pass (T95). Results: Using Tclin a failure rate of 5.9% over all QAs was observed. The highest failure rate was observed for gynecological (22%) and the lowest for CNS (0.9%) treatments. T95 was 91% over all QAs and ranged from 73% (gynecological) to 96.5% (CNS) for individual treatments sites. T95 was lower for IMRT and non-HD (high definition) MLCs at 88.5% and 94.5%, respectively, compared to 92.4% and 97.1% for VMAT and HD MLC treatments, respectively. There was a statistically significant difference between the passing rates for IMRT vs. VMAT and for HD MLCs vs. non-HD MLCs (p-values << 0.01). Gynecological, IMRT, and HD MLC treatments typically include more plans with larger field sizes. Conclusion: On average, Tclin with ArcCHECK was consistent with T95, as well as the 90% action level reported in TG-119. However, significant variations between the examined categories suggest a link between field size and QA passing rates and may warrant field size-specific passing rate thresholds.

60 APPLIED LIFE SCIENCES↗