Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ADIABATIC DEMAGNETIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Measuring the Liquid Helium Volume on XRISM and Predicting the Liquid Lifetime

The XRISM/Resolve instrument uses an adiabatic demagnetization refrigerator (ADR) to cool microcalorimeters to 50 mK. The cryogenic system to support the ADR consists of a liquid helium dewar and 5 cryocoolers that provide a semi-redundant system. Operation of the ADR requires either a liquid helium heat sink at 1.2 K or 4.5 K heat sink provided by a multi-stage cryocooler system. The 5 cryocoolers also provide thermal protection to the liquid helium dewar. To calculate the expected lifetime of the liquid helium system, the liquid helium volume was measured before launch and several techniques were employed to determine on-orbit boil off rate.

Michael Dipirro↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and Joule-Thomson and Stirling cryocoolers to reduce heat load on the He tank supporting the ADRs. Resolve was designed with tunable cryocooler drive frequencies so that interference could be avoided. The cryocooler generated micro-vibration changes with drive frequency and that micro-vibration causes interference and degrades instrument performance. Poor drive frequency choices have been shown to dramatically impact ADR cooling power, temperature stability, detector noise, and degrading spectroscopic performance. However, some choices are free of these features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is critical to achieving peak instrument performance. The drive frequencies of the Joule-Thomson cooler, near 52 Hz, and the Stirling coolers, near 15 Hz, were adjusted in three scan sequences while measuring interference to narrow candidate frequency options. Choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. These scans were performed routinely during ground testing. Surprisingly though, the results were not repeatable after the Dewar was warmed and re-cooled but were repeatable when remeasured during the same test campaign. Since the good/bad drive frequencies change during Dewar warmup/cooldown, and possibly after vibration events, the drive frequencies could not be finalized before launch. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

Development and Testing of a Superconducting Ground Plane on Transition Edge Sensors

Much of the normal matter in the universe is thought to exist as diffuse hot gas near 1.0 × 10 6 K, which can be detected through its 0.1–0.5 keV line emission. Distinguishing among multiple temperature regions and emission mechanisms along a line of sight requires resolving individual spectral lines in this particularly crowded spectral range. This requires 1–2 eV spectral resolution, which is currently only possible using grating spectrometers, which are suitable only for point sources, but not for the diffuse sources we wish to observe. We aim to measure individual spectral lines in this energy band using transition edge sensors (TES) that have the required 1–2 eV non-dispersive spectral resolution on a sounding rocket. While TESs offer sufficient energy resolution, they are very sensitive to ambient magnetic fields, e.g. from earth’s field and stray fields from the adiabatic demagnetization refrigerator (ADR) that is used to cool TESs to their ∼70 mK transition temperature. Strict space and weight limitations on the sounding rocket payload will limit the use of conventional high permeability magnetic shielding. Further design challenges arise in designing shielding with at least a 45∘ field of view, which is required to maintain a large enough throughput to obtain a useful spectrum on a brief (∼300 s) sounding rocket flight. Here we explore adding a superconducting ground plane (SGP) to the backside of the TES to reduce its field sensitivity and minimize attenuation requirements for the external shielding, which is based on prior work from (de Wit et al. 2022). We tested the feasibility of SGPs with novel materials, geometries, and on larger TESs with different biasing conditions.

Astrophysics↗

Design and Performance of the SPT-SLIM Receiver Cryostat

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wavelength line-intensity mapping experiment, which was deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We report on the cryogenic performance of the SPT-SLIM receiver for the first year of commissioning observations. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Refrigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150 mK. We demonstrate stable thermal performance of the focal plane module during observations consistent with thermal modeling, enabling a cryogenic operating efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

Young, M. R. [Fermilab; Chicago U., KICP]↗

Method for cooling nanostructures to microkelvin temperatures

We propose a new scheme aimed at cooling nanostructures to microkelvin temperature based on the well established technique of adiabatic nuclear demagnetization: we attach each device measurement lead to an individual nuclear refrigerator, allowing efficient thermal contact to a microkelvin bath. On a prototype consisting of a parallel network of nuclear refrigerators, temperatures of {approx}1 mK simultaneously on ten measurement leads have been reached upon demagnetization, thus completing the first steps toward ultracold nanostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of partial substitution of Ni by Co on the magnetic and magnetocaloric properties of Ni{sub 50}Mn{sub 35}In{sub 15} Heusler alloy

The magnetic and magnetocaloric properties of Ni{sub 48}Co{sub 2}Mn{sub 35}In{sub 15} were studied using magnetization and heat capacity measurements. The magnetic entropy change ({Delta}S{sub M}) was evaluated from both magnetizing and demagnetizing fields. An inverse {Delta}S{sub M} for the magnetizing and demagnetizing processes were found to be 20.5 and 18.5 J kg{sup -1} K{sup -1}, respectively, for {Delta}H = 5 T at the martensitic transition (T = T{sub M}). The normal {Delta}S{sub M} was found to be -5.4 J kg{sup -1} K{sup -1} for both fields at the paramagnetic/ferromagnetic transition (T = T{sub C}). The effective refrigeration capacity at T{sub M} and T{sub C} for magnetizing field was found to be 268 and 243 J/kg (285 and 243 J/kg for the demagnetizing field), respectively. We have also estimated the density of states, the Debye temperature, and the inverse adiabatic temperature change to be 4.93 states/eV f.u., 314 K, and -3.7 K, respectively, from the measured heat capacity data.

36 MATERIALS SCIENCE↗

Observation of Room-Temperature Range Magnetocaloric Effect in PrSr{sub 1−x}Pb{sub x}Mn{sub 2}O{sub 6} (0.4 ≤ x ≤ 0.6) Double-Perovskite Manganite System

The Pr(Sr{sub 1−x}Pb{sub x})Mn{sub 2}O{sub 6} (0.4 ≤ x ≤ 0.6) double-perovskite manganite samples have been produced by using a sol-gel method. The Rietveld refinement method has been used to analyse the structural properties, and the results show that all samples are crystallized in monoclinic structure with P21/n space group without any impurity phase. The temperature dependence of magnetization measurement shows that samples exhibit paramagnetic to ferromagnetic phase transition by decreasing temperature. The values of the T{sub C} are determined as 286, 280 and 278 K for x= 0.4, 0.5 and 0.6 in Pr(Sr{sub 1−x}Pb{sub x})Mn{sub 2}O{sub 6} samples, respectively. Isothermal applied magnetic field-dependent magnetization curves are used to determine both order of magnetic phase transition and magnetic entropy change (ΔS{sub M}) value. −ΔS{sub M} values are found as 3.68, 3.15 and 2.85 J kg{sup − 1} K{sup − 1} for PSPM-4, PSPM-5 and PSPM-6 samples, respectively. Additionally, magnetic phase transition of the samples is identified as second-order magnetic phase transition that indicates accompanying small thermal and magnetic hysteresis to the samples during the phase transition. Relative cooling power (RCP) values are determined as 282, 233 and 268 J kg{sup − 1} for PSPM-4, PSPM-5 and PSPM-6 samples, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thirty Years of Near Room Temperature Magnetic Cooling: Where we are Today and Future Prospects

The seminal study by Brown in 1976 showed that it was possible to use the magnetocaloric effect to produce a substantial cooling effect near room temperature. About 15 years later Green et al. built a device which actually cooled a load other than the magnetocaloric material itself and the heat exchange fluid. The major breakthrough, however, occurred in 1997 when the Ames Laboratory/Astronautics proof-of-principle refrigerator showed that magnetic refrigeration was competitive with conventional gas compression cooling. Since then, over 25 magnetic cooling units have been built and tested throughout the world. The current status of near room temperature magnetic cooling is reviewed, including a discussion of the major problems facing commercialization and potential solutions thereof. The future outlook for this revolutionary technology is discussed.

36 MATERIALS SCIENCE↗

Magnetism in Gd-W films

Vapor condensation techniques are useful to prepare magnetic alloys whose components have low or even negligible equilibrium mutual solubility. In this work, one of these techniques--sputtering--was used to obtain Gd{sub x}W{sub 1-x} alloys whose magnetic properties were investigated as a function of the Gd atomic concentration x. Gadolinium and various Gd-based alloys are promising materials for magnetic refrigeration and this was one of the motivations for this study. The Gd{sub x}-W{sub 1-x} films were sputter deposited from Gd and W targets with x ranging from 0 to 1 as determined by x-ray energy-dispersive spectroscopic analyses. X-ray diffraction patterns indicate that crystalline structures were formed at low and high Gd concentrations, while at intermediate concentrations, the films were amorphous. Magnetization measurements, performed as a function of temperature and with static and alternating applied fields, reveal a spin glasslike behavior in all the W-containing samples for temperatures below the freezing temperature T{sub f}. For low and intermediate Gd concentrations, and for T>T{sub f}, the films were paramagnetic, while a ferromagnetic phase was observed in the Gd-W alloy of the highest Gd content. The magnetocaloric effect was investigated from the magnetization isotherms M versus H, from which the isothermal magnetic entropy variation {delta}S{sub M} as a function of T, for the removal of an applied field of 50 kOe, was determined. It was observed that the maximum value of {delta}S{sub M} for each {delta}S{sub M} versus T curve and the temperature at which these maxima occur, are strongly dependent on x.

36 MATERIALS SCIENCE↗

MANX: A 6D Ionization-Cooling Experiment

Six-dimensional ionization cooling of muons is essential for muon colliders and possibly beneficial for neutrino factories. An experiment to demonstrate six-dimensional ionization cooling using practical apparatus is presented. It exploits recent innovative ideas that may lead to six-dimensional muon-cooling channels with emittance reduction approaching that needed for high-luminosity muon colliders.

43 PARTICLE ACCELERATORS↗

MUCOOL/MICE RF Cavity R and D Programs

We report recent progress on normal conducting RF cavity R and D for the US MUCOOL program and international Muon Ionization Cooling Experiment (MICE)

43 PARTICLE ACCELERATORS↗

A Dogbone Cooling Channel

Muon cooling schemes typically involve placing RF cavities in intense magnetic fields. Ongoing work has shown that this may reduce the maximum RF gradient by a significant factor. A linear cooling channel scheme is presented whereby RF cavities sit in much smaller fields. In addition, a scheme is studied for recirculating muons through this linear cooling channel in order to re-use hardware.

43 PARTICLE ACCELERATORS↗

Open Cavity Solutions to the rf in Magnetic Field Problem

It has been observed that breakdown in an 805 MHz pill-box cavity occurs at much lower gradients as an external axial magnetic field is increased. This effect was not observed with on open iris cavity. It is proposed that this effect depends on the relative angles of the magnetic and maximum electric fields: parallel in the pill-box case; at an angle in the open iris case. If so, using an open iris structure with solenoid coils in the irises should perform even better. A lattice, using this principle, is presented, for use in 6D cooling for a Muon Collider. Experimental layouts to test this principle are proposed.

43 PARTICLE ACCELERATORS↗

Challenge of Muon Cooling Rings

In order to obtain cost effective design for the neutrino factory and a front end of the muon collider compact rings for muon ionization cooling have been proposed in various schemes. Nevertheless muon cooling rings show several difficulties, which make their design a very challenging subject. In order to obtain space necessary for injection/extraction systems, 4 m long straight section has to be matched to low beta cooling section. Adiabatic matching is discussed, which was proposed as a solution for broad momentum deviation.

43 PARTICLE ACCELERATORS↗

Development of Large Aperture PRISM-FFAG Magnet

The magnetic field of three scaled-radial-sector fixed field alternating gradient (FFAG)-magnets has been measured. The measurements results are compared to a three-dimensional field analysis using the TOSCA code; the generated magnetic field agrees satisfactorily with the TOSCA calculation in a range of 0.5%. Tracking simulation with the measured-field map has been performed and compared to that with the TOSCA field map.

36 MATERIALS SCIENCE↗

The Effect of Extending the Length of the Coupling Coils in a Muon Ionization Cooling Channel

RF cavities are used to re-accelerate muons that have been cooled by absorbers that are in low beta regions of a muon ionization cooling channel. A superconducting coupling magnet (or magnets) are around or among the RF cavities of a muon ionization-cooling channel. The field from the magnet guides the muons so that they are kept within the iris of the RF cavities that are used to accelerate the muons. This report compares the use of a single short coupling magnet with an extended coupling magnet that has one or more superconducting coils as part of a muon-cooling channel of the same design as the muon ionization cooling experiment (MICE). Whether the superconducting magnet is short and thick or long and this affects the magnet stored energy and the peak field in the winding. The magnetic field distribution also affects is the muon beam optics in the cooling cell of a muon cooling channel.

43 PARTICLE ACCELERATORS↗