Quench detection using Hall sensors in high-temperature superconducting CORC ® -based cable-in-conduit-conductors for fusion applications

Advanced magnet systems for fusion applications would greatly benefit from the use of high-temperature superconductors (HTS). These materials allow fusion magnets to operate at higher magnetic fields, allowing for more compact fusion machines, and allow for operation at elevated temperatures, enabling demountable coils that provide access for maintenance of the fusion reactor. Quench detection remains a major challenge in the protection of HTS magnets that are vulnerable to localized conductor burnout due to their low quench propagation velocities. One of the methods explored is the use of Hall sensors that are incorporated in or near the magnet terminations that can detect local field variations that occur as a result of current redistribution within the conductor to bypass a hotspot within the magnet winding. This method is potentially well suited for Cable in Conduit Conductors, such as those made from Conductor on Round Core (CORC) cables, in which sub-cables containing HTS tapes are connected to the terminations at a low resistance. Here, to demonstrate the technique, a CORC ® triplet consisting of three sub-cables, rated for 4 kA operation at 77 K, was manufactured and Hall sensors were used to measure local field variations next to the terminations due to current redistribution between the cables. The Hall response was compared to voltages that developed over the cables and terminations as a local hotspot was applied to different cables in the triplet. It was found that the Hall sensors were faster and more sensitive than voltage contact measurements and were able to reliably detect current redistribution of only a few amperes caused by a hotspot, well before the triplet exceeded its critical current. The method also allowed the detection of heater-induced hotspots during high ramp rates of 2 kA s<:sup>–1 relevant for fusion applications. Hall sensors have a distinct benefit of being less sensitive to inductive pickup of AC interference compared to voltage contact measurements that make quench detection through voltage measurements in magnets especially challenging. The method can also be used for diagnostic measurements of current redistribution caused by other sources such as inhomogeneous current injection from faulty joints, or localized conductor damage. The Hall sensors are likely capable of detecting the onset of a quench that may occur a far distance away from the sensor location, presenting a breakthrough in HTS quench detection that potentially removes one of the remaining barriers to reliable operation of large HTS magnet systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quench protection for high-temperature superconductor cables using active control of current distribution

Superconducting magnets of future fusion reactors are expected to rely on composite high-temperature superconductor (HTS) cable conductors. In presently used HTS cables, current sharing between components is limited due to poorly defined contact resistances between superconducting tapes or by design. The interplay between contact and termination resistances is the defining factor for power dissipation in these cables and ultimately defines their safe operational margins. However, the current distribution between components along the composite conductor and inside its terminations is a priori unknown, and presently, no means are available to actively tune current flow distribution in real-time to improve margins of quench protection. Also, the lack of ability to electrically probe individual components makes it impossible to identify conductor damage locations within the cable. In this work, we address both problems by introducing active current control of current distribution between components using cryogenically operated metal-oxide-semiconductor-field-effect transistors (MOSFETs). We demonstrate through simulation and experiments how real-time current controls can help to drastically reduce heat dissipation in a developing hot spot in a two-conductor model system and help identify critical current degradation of individual cable components. Finally, prospects of other potential uses of MOSFET devices for improved voltage detection, AC loss-driven active quench protection, and remnant magnetization reduction in HTS magnets are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Kelvin–Helmholtz instability under stabilizing parallel magnetic field in nonhomogeneous compressible MHD flows

We study the Kelvin–Helmholtz instability (KHI) for the general case of a compressible, nonhomogeneous, magnetized plasma flow. The study is limited to a vortex sheet interface with an imposed parallel magnetic field. We introduce a new formalism based on a convective Mach number M c , a convective Alfvénic Mach number M Ac , and a total convective Mach number that combines the two. We derive an analytic expression of the KHI growth rate for a homogeneous flow (i.e., zero Atwood number, A=0) that converges toward both the expression for unmagnetized compressible flow and Chandrasekhar's expression for magnetized incompressible flow. Otherwise, the dispersion relation is solved numerically and allows deriving general stability diagrams of magnetized KHI for the triplet (A, M c , β −plasma) parameters. We show these parameters uniquely define all configurations for a parallel magnetic field. We also construct diagrams with respect to the convective Alfvénic Mach number, the β − plasma parameter, or the magnetic field showing which magnetic field strength is required for stabilizing a given shear flow. The theoretical growth rates are compared with 18 simulations made with the GAMERA code, currently used for 3D magnetospheric simulations. Finally, we apply our results to the analysis of a past KHI experiment performed at the OMEGA laser facility, showing linear theory succeeds to provide accurate estimates of the growth rate at early times. We further discuss how our results can inform future experiments in the high-Mach magnetized regime at the National Ignition Facility. Possible limitations of the study due to resistive, mixing, or turbulence effects are discussed.

compressible flows↗

DC Arc Incident Energy in Photovoltaic Systems: Methods for Evaluation

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This article focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of dc arc-flash incident energy (IE) evaluation. Because of the fast proliferation of PV systems and lack of formal equivalent calculation guidelines, such as IEEE 1584 for ac systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This article discusses the behavior of PV systems under arc conditions and presents the results of the available methods to estimate the dc arc-flash IE. It provides a comparative analysis of a proposed arc-flash IE calculation method against different laboratory tests, including those performed for this article at the National Renewable Energy Laboratory (NREL). Detailed explanations are provided regarding the effect of the PV module current-voltage (I-V) and power-voltage (P-V) curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

arc discharges↗

New Approaches to Low-Cost Scalable Doping of Interdigitated back Contact Silicon Solar Cells (Final Report)

The goal of this project was to develop novel approaches to patterning of dopants in the rear fingers of interdigitated back contact (IBC) Si solar cells to reduce the cost of manufacturing this high-efficiency-potential cell architecture. The work throughout this project can be divided into four categories: (a) development of dopant patterning technique using laser scribed Si contacts masks that are mechanically aligned with ~10 μm resolution to the underlying Si substrate; (b) measuring dopant spreading profiles in the isolation region between n- and p-type dopant fingers during plasma-enhanced chemical vapor deposition (PECVD) of doped hydrogenated amorphous silicon (a-Si:H) via shadow masks, and dopant desorption and re-adsorption during high-temperature annealing; (c) understanding the role of dopant compensation on the shunt resistance in contaminated isolation regions through analysis of defect-enhanced compensation; and (d) simulation and fabrication of passivated two-sided grid and back-contact solar cells to demonstrate the use of direct dopant patterning in cell fabrication. For the passivated two-sided grid solar cells, masked deposition was used to demonstrate an improvement in the blue response of the cell by creating a shallow front emitter. During development of the masked PECVD patterning process, we measured 3-D dopant profiles using secondary ion mass spectrometry. After deposition, in the masked region, the phosphorus dopant tail was >100 µm at concentrations >10 19 cm -3 while the boron dopant tail was shorter. During high-temperature crystallization of doped a-Si:H films to polycrystalline Si (poly-Si), phosphorus atoms spread by desorbing from the poly-Si surface and re-adsorbing onto intrinsic poly-Si on adjacent wafers that were separated by several millimeters. These contamination mechanisms resulted in a decrease in resistivity from ~10 5 Ω·cm for intrinsic poly-Si to ~10 -1 Ω·cm for contaminated poly-Si. Mitigation strategies for each contamination mechanism were developed to maintain a resistivity of ~10 5 Ω·cm between doped fingers. During fabrication of the 209 cells created during this project, it was found that despite contamination of the IBC gap through the abovementioned mechanisms, high shunt resistances and FF ~75% were still reached. Investigation into this led to the discovery of defect-enhanced compensation which exists within highly defective poly-Si when net doping concentrations reach the value of defect density (~10 18 cm -3 for many poly-Si films). Simulations guided us in the fabrication of IBCs and the cells fabricated were able to meet the year-end goals for BP 2 and 3 of 15% and 17% IBC cell efficiency, as well as the BP 4 goal of a 1% absolute increase in efficiency for PERC-like devices. However, the most efficient cell created during this project of 18.6% fell short of the 21% final project target. While the champion device fell short in V oc and J sc , many devices fabricated were able to reach the necessary goals of ~40 mA/cm 2 , ~700 mV, and ~75% FF required for a 21% device. The results generated from this project were disseminated through 11 conference presentations and proceedings. Presentations included oral talks at 2019 IEEE PVSC, 2019 MRS Fall Meeting, 2020 PVSEC-30 and 2021 IEEE PVSC, as well as poster presentations at 2020 IEEE PVSC and 2021 SiPV. The project resulted in 2 peer reviewed publications – one published in IEEE Journal of Photovoltaics and one in ACS Applied Energy Materials. The information gained in this project will aid in development of improved processes for fabrication of high-efficiency solar cells and other areas of the semiconductor device industry as well. The IBC cells will also pave the way for higher efficiency tandem devices. Through further manufacturing of high-efficiency solar cells, more of the world’s energy demands can be met through renewable sources, helping to stave off the worst effects that may come about from global climate change.

14 SOLAR ENERGY↗

Vortex phase diagram of the kagome superconductor CsV 3 ⁢Sb 5

The screening response of the kagome superconductor CsV 3 ⁢Sb 5 was obtained from high-resolution ac mutual inductance measurements. At zero applied magnetic field and low temperatures, we observe no evidence for gapless quasiparticles, while near T c we find evidence for enhanced fluctuations. A rich vortex state appears above H c⁢1 ≈30 Oe, exhibiting successive emergence of vortex phases. For a fixed magnetic field, lowering the temperature below T c⁡ (H) leads to a wide range of vortex liquid state in a landscape of weak pinning potential, which gives rise to an irreversibility line. Further lowering the temperature, we identify the vortex melting line followed by the peak effect manifested in enhanced vortex pinning strength and critical current. Finally, we suggest that such an unusual behavior, where the peak effect region is fully contained within the vortex lattice state below the irreversibility line, is a consequence of the strong anisotropy and weak bulk pinning in CsV 3 ⁢Sb 5 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Submicrosecond Power-Switching Test Circuit

A circuit that changes an electrical load in a switching time shorter than 0.3 microsecond has been devised. This circuit can be used in testing the regulation characteristics of power-supply circuits . especially switching power-converter circuits that are supposed to be able to provide acceptably high degrees of regulation in response to rapid load transients. The combination of this power-switching circuit and a known passive constant load could be an attractive alternative to a typical commercially available load-bank circuit that can be made to operate in nominal constant-voltage, constant-current, and constant-resistance modes. The switching provided by a typical commercial load-bank circuit in the constant-resistance mode is not fast enough for testing of regulation in response to load transients. Moreover, some test engineers do not trust the test results obtained when using commercial load-bank circuits because the dynamic responses of those circuits are, variously, partly unknown and/or excessively complex. In contrast, the combination of this circuit and a passive constant load offers both rapid switching and known (or at least better known) load dynamics. The power-switching circuit (see figure) includes a signal-input section, a wide-hysteresis Schmitt trigger that prevents false triggering in the event of switch-contact bounce, a dual-bipolar-transistor power stage that drives the gate of a metal oxide semiconductor field-effect transistor (MOSFET), and the MOSFET, which is the output device that performs the switching of the load. The MOSFET in the specific version of the circuit shown in the figure is rated to stand off a potential of 100 V in the "off" state and to pass a current of 20 A in the "on" state. The switching time of this circuit (the characteristic time of rise or fall of the potential at the drain of the MOSFET) is .300 ns. The circuit can accept any of three control inputs . which one depending on the test that one seeks to perform: a repetitive waveform from a signal generator, momentary closure of a push-button switch, or closure or opening of a manually operated on/off switch. In the case of a signal generator, one can adjust the frequency and duty cycle as needed to obtain the desired AC power-supply response, which one could display on an oscilloscope. Momentary switch closure could be useful for obtaining (and, if desired, displaying on an oscilloscope set to trigger on an event) the response of a power supply to a single load transient. The on/off switch can be used to switch between load states in which static-load regulation measurements are performed.

Folk, Eric N.↗

AC and DC Fault Management for Megawatt Electrified Aircraft Electrical Powertrains Task 3: Lifetime and Reliability of Electrical Insulators

This research project was a collaborative investigation between researchers at the RTX Technology Research Center (RTRC) and the University of Texas at Austin and made a significant contribution to enabling electric aircraft. The transport of electric power between the points of generation and use requires power cables. These cables must be smaller, lighter and provide a more predictable life than power cables used in stationary applications. Consequently, this investigation provided heretofore unavailable information supporting the safety and reliability of smaller lighter power cables for electrified aircraft. In addition, the research identified key additional engineering data needed to support quantitative reliability assessments. Important advances included: • Demonstrated that at least one manufacturer can make a novel, smaller, lighter power cable that is free from serious defects. • Developed and published an appropriate analytical construct to describe the life of this novel cable. This is a necessary step for use in aviation where the understanding of remaining life is critical. • Demonstrated thermal-mechanical aging that suggested 1000+ flights before the thermal-mechanical processes produced defects large enough that the defect growth was accelerated electrically. • Showed that electrical aging took place at two rates. The first possibly lasting weeks to months and the second possibly days to weeks. If robust, this provides a good diagnostic for cable replacement. • Demonstrated that the traditional electrical testing of cable materials using manufactured voids can be misleading due to the size of the voids. Emerging laser drilling technology permitted demonstration that the physics of failure in realistically small voids is different from that in the unrealistically large voids used in earlier research, which is very important for high-quality, high-performance, small aircraft cables. Although this project represents a significant contribution to the specifics of cable aging in the aircraft environment, important additional research remains to be completed, including: • Non-uniform thermal cycling by applying the heat from the center conductor to maximize thermal stress next to the core area where the electric gradient is the strongest. This builds on the uniform thermal cycling that has been completed. • The augmentation of the thermal-mechanical failure rate by electrical processes. Better understanding of these time constants strongly affects the ability to predict life. • Termination design: Terminations provide not only electrical reflection potential, but a location for a series arc fault and an area where ozone can diffuse into the center conductor and negatively affect cable insulation. • The abrasion and ozone resistance of the cable jacket. • Pressure cycling as an accelerant of thermal, mechanical, and/or electrical aging. • Possible methods for online PD detection and offline PD localization

model↗

EcAMSat: Small Satellite to Examine E. coli's Response in Microgravity to the Antibiotic Gentamicin

We have successfully flown the EcAMSat (Escherichia coli Antimicrobial Satellite) free-flyer mission. This was a 6U small satellite that autonomously conducted an experiment in low Earth orbit to explore the impact of the space environment on antibiotic resistance in uropathogenic E. coli (UPEC) and the role a particular sigma factor plays in the response. After being held in stasis during transport to orbit, two strains†a wildtype UPEC and an isogenic mutant with a deleted gene that encodes a sigma factor†were grown to stationary phase in a fluidic card inside EcAMSat's payload, then incubated with three concentrations of the antibiotic gentamicin. The payload then administered alamarBlue®, a redox indicator, into all wells of the fluidic card. The cells were then incubated for 144 hours and metabolic activity was measured optically using the payloads' LED and detector system. Data were then telemetered to the ground and compared to a control experiment conducted in an identical satellite in a lab. The results of this experiment will help us better understand important therapeutic targets for treating bacterial infections on Earth and in space. Such targets are particularly relevant to deep-space and long-duration missions where crew may be more susceptible to infection and treatments for them may work differently.

antibiotic↗

Interplay of structure and magnetism in LuFe 4 ⁢Ge 2 tuned by hydrostatic pressure

Lu⁢Fe 4 ⁢Ge 2 crystallizes in the Zr⁢Fe 4 ⁢Si 2 -type structure, hosting chains of Fe tetrahedra giving rise to geometric frustration and low dimensionality. The compound orders antiferromagnetically at around 36 K accompanied by a simultaneous structural transition from a tetragonal phase to an orthorhombic phase. The hydrostatic pressure dependence of the magnetic and structural transitions is investigated using electrical transport, AC magnetic susceptibility, AC calorimetry, M⁢össbauer, muon-spin relaxation (μ⁢SR), and x-ray-diffraction measurements. External pressure suppresses the first-order transition to the antiferromagnetic phase (AFM1) around 1.8 GPa. The structural transition is largely unaffected by pressure and remains between 30 to 35 K for pressures up to 2 GPa. A second antiferromagnetic phase (AFM2) is observed at higher pressures. The transition from the paramagnetic to the AFM2 phase is of second-order nature and appears to be connected to the structural transition. The magnetic volume fraction obtained from μ⁢SR and M⁢össbauer measurements reveal that the entire sample undergoes magnetic ordering in both magnetic phases. In addition, similar low-temperature muon-precession frequencies in AFM1 and AFM2 phases point at similar ordered moments and magnetic structures in both phases. Our results further indicate enhanced magnetic fluctuations in the pressure-induced AFM2 phase. The experimental observations together with density functional theory calculations suggest that the magnetic- and structural-order parameters in Lu⁢Fe 4 ⁢Ge 2 are linked by magnetic frustration, causing the simultaneous magnetostructural transition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗