Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Synthesis of Mg-Al and Zn-Al-layered double hydroxide nanocrystals using laser ablation in water

In this paper, we report our results on the synthesis of Mg-Al and Zn-Al-layered double hydroxides using the laser ablation in the liquid technique. To prepare these layered double hydroxides (LDH) we first began with the laser generation of a Mg (or zinc) target submerged in deionized water and then ablated an aluminum target submerged in the previously prepared Mg-deionized water suspensions (Mg-dw) to produce Mg-Al LDH and in Zn-dw to prepare Zn-Al LDH. In these ablation tests, the Mg ablation duration was selected to vary from 5 to 60 min, while the Al ablation duration was kept constant at 30 min for all samples. The generated Mg-Al LDH was a gel-like and well crystallized nanoparticles of a rod-like shape and were arranged in a well-organized pattern. When the Mg ablation duration between 25 and 35 min, the synthesized nanocrystals were stoichiometric with a formula of Mg6Al2(OH)(18)4.5 (H2O), the interlayer distance (d((0 0 3))-spacing) was 7.8 angstrom and the average grain size was 8.0 nm. The synthesized Zn-Al LDH revealed various lamellar thin plate-like nanostructures of hexagonal morphologies. The average diameters of these structures was about 500 nm and the thickness of a single layer was approximately about 6.0 nm. The XRD diffraction peaks were indexed in hexagonal lattice with a(o) = 3.07 angstrom and c(o) = 15.12 angstrom. These indexes were (002), (004), and (008) and the corresponding interlayer distances, d-spacing (angstrom), were 7.56 (002), 3.782 (004), and 1.891 (008), respectively.

36 MATERIALS SCIENCE↗

Nonlinear bubble competition of the multimode ablative Rayleigh–Taylor instability and applications to inertial confinement fusion

The self-similar nonlinear evolution of the multimode ablative Rayleigh–Taylor instability (RTI) and the ablation-generated vorticity effect are studied for a range of initial conditions. We show that, unlike classical RTI, the nonlinear multimode bubble-front evolution remains in the bubble competition regime due to ablation-generated vorticity, which accelerates the bubbles, thereby preventing a transition into the bubble-merger regime. We develop an analytical bubble competition model to describe the linear and nonlinear stages of ablative RTI. Here, we show that vorticity inside the multimode bubbles is most significant at small scales with large initial perturbation. Since these small scales persist in the bubble competition regime, the self-similar growth coefficient ab can be enhanced by up to 30% relative to ablative bubble competition without vorticity effects. We use the ablative bubble competition model to explain the hydrodynamic stability boundary observed in OMEGA low-adiabat implosion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mechanisms of graphite ablation by sub-millisecond ytterbium fiber laser pulses

Graphite is a key material in a variety of cross-cutting applications in energy conversion, energy storage, and nuclear energy. Recently, temporally modulated continuous wave lasers have been shown to produce well-defined ablation features in graphite at relatively high processing speeds. In this work, we analyze in detail the laser ablation dynamics of single-pulse ablation in the sub-millisecond time regime to elucidate the origins of the resulting well-defined ablation craters using a combination of time-resolved emission imaging, diffuse reflection/scattering imaging, and optical emission spectroscopy. These multimodal in situ diagnostics revealed three main contributors to achieve well-defined ablation features: (1) rapid ejection of particles with ~100 m/s speed, (2) ablation of the graphite in the gaseous form, and (3) absence of bulk liquid motion, which is typically observed in laser processing of metals. Plasma plume formation was sustained throughout the duration of the laser pulse (500 μs). Here, this work provides insights into the complex physical and chemical mechanisms of sub-millisecond laser–matter interactions, which are critical for parameter space optimization and tailoring of laser machining and drilling processes.

42 ENGINEERING↗

Measuring and simulating ice–ablator mix in inertial confinement fusion

Fuel–ablator mix has been established as a major performance degrading effect in the burning plasma regime of recent inertial confinement fusion (ICF) experiments. As such, the study of fuel–ablator mix with experiments and simulations can provide valuable insight for our understanding of these experiments and establish a path for even higher yields and increased robustness. Here we present a novel high-yield experimental ICF design that is motivated by recent experiments measuring ice–ablator mix with a CH ablator instead of a high-density carbon (HDC) ablator. Here we review these experiments in more detail and describe the modeling assumptions and parameters used to obtain agreement with the data from implosion and burn simulations with mix. Using this mix model calibrated a posteriori to the experimental data, we design an implosion that uses a CH ablator that is predicted to achieve better performance than a recent experiment that achieved net target gain of 1.5 in HDC. Because hydrodynamic instabilities are greatly reduced with this new design, we also expect a high reproducibility at the same implosion adiabat as current record yield experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of mix at the fuel–ablator interface in indirectly driven capsule implosions on the National Ignition Facility

The interface between the capsule ablator and fuel ice layer is susceptible to hydrodynamic instabilities. The subsequent mixing of hot ablator material into the ice reduces fuel compression at stagnation and is a candidate for reduced capsule performance. The ability to diagnose ice–ablator mix is critical to understanding and improving stability at this interface. Combining the crystal backlighter imager with the single line of sight camera on the National Ignition Facility (NIF) allows direct measurement of ice–ablator mix by providing multiple quasi-monochromatic radiographs of layered capsule implosions per experiment with high spatial (∼12 μm) and temporal (∼35 ps) resolution. The narrow bandwidth of this diagnostic platform allows radiography of the inner edge of the capsule limb close to stagnation without capsule self-emission contaminating the data and removes opacity uncertainties typically associated with the spectral content of the radiograph. Analysis of radiographic data via a parameterized forward-fitting Abel inversion technique provides measurements of the distribution of mix mass inwards from the ice–ablator interface. The sensitivity of this mix measurement technique was demonstrated by applying it to layered experiments in which the stability of the ice–ablator interface was expected to vary significantly. Additional experiments suggest that high-density carbon capsules that employ a buried-layer dopant profile suffer from mixing at the innermost doped–undoped interface. Data from these experiments suggest that opacity models used in hydrodynamic simulations of NIF experiments can potentially over-predict the opacity of doped capsules. LLNL-JRNL-850535-DRAFT.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of ablation and shock generation across three orders of magnitude of laser intensity with 100 ps laser pulses

The laser ablation and subsequent shock generation in solid targets plays an important role in a variety of research topics from equation of state models for materials to inertial confinement fusion. One of the long-standing issues is the knowledge of ablation depth in the picosecond time regime. Here, we report on a direct technique for determining the ablation depth in aluminum using x-ray diffraction data from Linac Coherent Light Source at the Stanford Linear Accelerator Center. This technique gives a direct measurement of the shock wave propagation in the bulk target, enabling an ability to discern early timescale physics from late timescale effects not available in postmortem analysis. We find that the ablation depths only vary by 0.2 μm across three orders of magnitude of laser intensity, while the pressure increased by a factor of 10 following a square root dependence on laser pulse energy. We further observe that the ablation depth in this intensity range (10 11 –10 13 W/cm 2 in intensity, corresponding to 0.8–80 J/cm 2 in fluence) cannot be modeled by a universal scaling law, given the complexity of the mechanisms governing laser ablation in this intensity regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Supercritical Drying of Wet Gel Layers Generated Inside ICF Ablator Shells

Spherical ablator shells that contain a thin layer of ultralow-density polymer foam have recently attracted attention in the inertial confinement fusion (ICF) community as they can be used to bring dopants for diagnostics and nuclear physics experiments in direct contact with the deuterium-tritium (DT) fuel or to study new ignition regimes by enabling the formation of uniform liquid DT fuel layers. We developed a method to fabricate these foam-lined ablator shells using a prefabricated ablator as a mold to cast the foam liner within the shell. One crucial component of this new approach is the removal of solvent from the ablator shells without collapsing the ultralow-density porous polymer network. In this work, we report on a supercritical drying approach with liquid carbon dioxide that provides critical information on how to produce thin layers of low-density polymer foams in ablator shells for ICF experiments. Diffusion experiments were used to study the time required for complete solvent exchange in 2-mm-inner-diameter diamond shells and the data were used to demonstrate the fabrication of uniform porous polymer films inside ablator shells.

36 MATERIALS SCIENCE↗

Refining Methods to Determine the Isotopic Composition of Uranium Particles by Laser Ablation MC-ICP-MS

We report on efforts to mitigate the generation of isotopic anomalies during the ablation of micrometer-sized uranium oxide particles and analysis by MC-ICP-MS. The results of testing on particles of U200 indicate that laser fluence and frequency can affect isotopic data produced by laser ablation, but no settings were tested that could eradicate the signal spiking effect and generation of anomalous isotopic data for 234U/238U and 236U/238U. These anomalies are more frequent in samples with higher 235U enrichments, which is expected given their higher abundances of 234U and 236U. Of the standards tested here, only U005-A was anomaly-free. Efforts to compare the laser traces for particles with normal and anomalous isotopic compositions showed subtle differences in the behavior of the 234U/238U and 236U/238U ratios. However, it would be challenging to identify anomalous data points from a population of unknowns using this distinction, i.e., this is unlikely to be diagnostic. Thus, using current analytical hardware, we cannot eradicate the signal spiking phenomenon and cannot unambiguously identify isotopic anomalies from laser ablation traces. Ultimately, laser ablation ICP-MS would either require dramatic improvement to the ablation process and generation of more homogenous aerosols and/or improvements to detector electronics to identify and correct for the spiking phenomenon. Even if the reliability of the technique could be improved, a broader question to address is whether current data quality is of a high enough standard for laser ablation MC-ICP-MS to be used as a complementary technique to LG-SIMS for Safeguards.

organic↗

Analytical model of low and high ablation regimes in carbon arcs

Graphite ablation by an electric arc or a laser/solar flux is widely used for the synthesis of carbon nanomaterials. Previously, it was observed in multiple arc experiments that the ablation rate is a strong nonlinear function of the arc current and it drastically increases at some threshold current. As such, we developed an analytical model explaining this transition in the rate of ablation by an electric arc or a laser/solar flux. The model not only explains the observations but can also accurately predict the experimentally observed ablation rates. The model takes into account redeposition of carbon back to the ablated surface, which is the key process responsible for the observed effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiofrequency Ablation of Subpleural Lung Malignancy: Reduced Pain Using an Artificially Created Pneumothorax

One of the main issues with radiofrequency (RF) ablation of the subpleural lung malignancy is pain management during and after RF ablation. In this article, we present a case that utilized a technique to decrease the pain associated with RF ablation of a malignancy located within the subpleural lung. Under CT guidance, we created an artificial pneumothorax prior to the RF ablation, which resulted in minimizing the pain usually experienced during and after the procedure. It also decreased the amount of pain medications usually used in patients undergoing RF ablation of a subpleural lung lesion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Radiofrequency Ablation (RFA) of Unresectable Hepatic Tumors Using a Triple-Spiral-Shaped Electrode Needle: Initial Experience in 34 Patients

We evaluated the safety and efficacy of image-guided radiofrequency ablation (RFA) using a triple-spiral-shaped electrode needle for unresectable primary or metastatic hepatic tumors. Thirty-four patients with 46 index tumors were treated. Ablation zone, morbidity, and complications were assessed. The lesions were completely ablated with an ablative margin of about 1 cm. Five patients (14.7%) with a lesion larger than 4.5 cm had local tumor progression after 1 month and were retreated. Hemothorax, as a major complication, occurred in 1 of 34 patients (3.0%) or 1 of 46 lesions ablated (2.2%). RFA using this new electrode needle can be effective in the treatment of large unresectable hepatic tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Tumor Radiofrequency Ablation: Where Do We Stand?

Today, radiofrequency ablation (RFA) of primary and metastatic lung tumor is increasingly used. Because RFA is most often used with curative intent, preablation workup must be a preoperative workup. General anesthesia provides higher feasibility than conscious sedation. The electrode positioning must be performed under computed tomography for sake of accuracy. The delivery of RFA must be adapted to tumor location, with different impedances used when treating tumors with or without pleural contact. The estimated rate of incomplete local treatment at 18 months was 7% (95% confidence interval, 3-14) per tumor, with incomplete treatment depicted at 4 months (n = 1), 6 months (n = 2), 9 months (n = 2), and 12 months (n = 2). Overall survival and lung disease-free survival at 18 months were, respectively, 71 and 34%. Size is a key point for tumor selection because large size is predictive of incomplete local treatment and poor survival. The ratio of ablation volume relative to tumor volume is predictive of complete ablation. Follow-up computed tomography that relies on the size of the ablation zone demonstrates the presence of incomplete ablation. Positron emission tomography might be an interesting option. Chest tube placement for pneumothorax is reported in 8 to 12%. Alveolar hemorrhage and postprocedure hemoptysis occurred in approximately 10% of procedures and rarely required specific treatment. Death was mostly related to single-lung patients and hilar tumors. No modification of forced expiratory volume in the first second between pre- and post-RFA at 2 months was found. RFA in the lung provides a high local efficacy rate. The use of RFA as a palliative tool in combination with chemotherapy remains to be explored.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiofrequency Ablation of Non-Small-Cell Carcinoma of the Lung Under Real-Time FDG PET CT Guidance

Radiofrequency ablation (RFA) is a well-established method in treatment of patients with lung carcinomas who are not candidates for surgical resection. Usually computed tomographic (CT) guidance is used for the procedure, thus enabling needle placement and permitting evaluation of complications such as pneumothorax and bleeding. {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET) is generally used for tumor activity assessment and is therefore useful in follow-up after tumor treatment. A method that provides real-time image-based monitoring of RFA to ensure complete tumor ablation would be a valuable tool. In this report, we describe the behavior of preinjected FDG during PET CT-guided RFA of a non-small-cell lung carcinoma and discuss the value of FDG as a tool to provide intraprocedure monitor ablation. The size and the form of the activity changed during ablation. Ablation led to increase of the size and blurring and irregularity of the contour compared to pretreatment imaging. The maximal standardized uptake value decreased only slightly during the procedure. Therefore, before RFA, FDG PET can guide initial needle placement, but it does not serve as a monitoring tool to evaluate residual viable tissue during the procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Incidence and Cause of Hypertension During Adrenal Radiofrequency Ablation

Purpose: To evaluate the incidence and cause of hypertension prospectively during adrenal radiofrequency ablation (RFA). Methods: For this study, approved by our institutional review board, written informed consent was obtained from all patients. Patients who received RFA for adrenal tumors (adrenal ablation) and other abdominal tumors (nonadrenal ablation) were included in this prospective study. Blood pressure was monitored during RFA. Serum adrenal hormone levels including epinephrine, norepinephrine, dopamine, and cortisol levels were measured before and during RFA. The respective incidences of procedural hypertension (systolic blood pressure >200 mmHg) of the two patient groups were compared. Factors correlating with procedural systolic blood pressure were evaluated by regression analysis.ResultsNine patients underwent adrenal RFA and another 9 patients liver (n = 5) and renal (n = 4) RFA. Asymptomatic procedural hypertension that returned to the baseline by injecting calcium blocker was found in 7 (38.9%) of 18 patients. The incidence of procedural hypertension was significantly higher in the adrenal ablation group (66.7%, 6/9) than in the nonadrenal ablation group (11.1%, 1/9, P < 0.0498). Procedural systolic blood pressure was significantly correlated with serum epinephrine (R{sup 2} = 0.68, P < 0.0001) and norepinephrine (R{sup 2} = 0.72, P < 0.0001) levels during RFA. The other adrenal hormones did not show correlation with procedural systolic blood pressure. Conclusion: Hypertension occurs frequently during adrenal RFA because of the release of catecholamine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-guided Neurolytic Celiac Plexus Ablation: An Evaluation of Effect and Injection Spread Pattern in Cancer Patients with Celiac Tumor Infiltration

ObjectiveThe purpose of this study was to evaluate the feasibility, the initial accuracy, and the effects of the MR-guided neurolytic celiac plexus ablation as a method to treat cancer-induced chronic abdominal pain. Thirteen celiac plexus ablations were performed for 12 patients. A 0.23-T open MRI scanner with optical navigation was used for procedural guidance. As an adjunct to the MR-guided needle positioning, the needle location was confirmed with saline injection and consequent MR imaging (STIR sequence). The spread of the ablative injection material (alcohol-lidocaine mix) was observed by repeating this sequence after the therapeutic injection. Pain scores from seven patients (eight ablations) were used to assess the therapy effect. MR guidance allowed adequate needle positioning and visualization of injection material in all cases. The rest pain scores significantly decreased from 4 (median) at baseline to 1 (median) at 2 weeks (p < 0.05). Average and worst pain experienced during the past week were significantly lower at the 2-week time point compared with the baseline (p < 0.05). However, the intervention did not result in reduction of opioid use at 2 weeks.MR guidance is an accurate and safe method for celiac plexus ablation with positive therapeutic effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-Guided High-Intensity Focused Ultrasound Ablation of Breast Cancer with a Dedicated Breast Platform

Optimizing the treatment of breast cancer remains a major topic of interest. In current clinical practice, breast-conserving therapy is the standard of care for patients with localized breast cancer. Technological developments have fueled interest in less invasive breast cancer treatment. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a completely noninvasive ablation technique. Focused beams of ultrasound are used for ablation of the target lesion without disrupting the skin and subcutaneous tissues in the beam path. MRI is an excellent imaging method for tumor targeting, treatment monitoring, and evaluation of treatment results. The combination of HIFU and MR imaging offers an opportunity for image-guided ablation of breast cancer. Previous studies of MR-HIFU in breast cancer patients reported a limited efficacy, which hampered the clinical translation of this technique. These prior studies were performed without an MR-HIFU system specifically developed for breast cancer treatment. In this article, a novel and dedicated MR-HIFU breast platform is presented. This system has been designed for safe and effective MR-HIFU ablation of breast cancer. Furthermore, both clinical and technical challenges are discussed, which have to be solved before MR-HIFU ablation of breast cancer can be implemented in routine clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Haemorrhagic Complications and Symptomatic Venous Thromboembolism in Interventional Tumour Ablations: The Impact of Peri-interventional Thrombosis Prophylaxis

AimThe aim of this study was to assess the rates of haemorrhagic and thrombotic complications in patients undergoing interventional tumour ablation with and without peri-interventional low-molecular-weight heparin (LMWH) thrombosis prophylaxis.MethodsPatients presented with primary and secondary neoplastic lesions in the liver, lung, kidney, lymph nodes and other locations. A total of 781 tumour ablations (radiofrequency ablation, n = 112; interstitial brachytherapy, n = 669) were performed in 446 patients over 22 months; 260 were conducted under peri-interventional thrombosis prophylaxis with LMWH (H-group;) and 521 without this (NH-group, in 143 of these, LMWH was given post-interventionally).ResultsSixty-three bleeding events occurred. There were significantly more bleedings in the H-group than in the NH-group (all interventions, 11.66 and 6.26 %, p = 0.0127; liver ablations, 12.73 and 7.1 %, p = 0.0416). The rate of bleeding events Grade ≥ III in all procedures was greater by a factor of >2.6 in the H-group than in the NH-group (4.64 and 1.73 %, p = 0.0243). In liver tumour ablations, the corresponding factor was about 3.3 (5.23 and 1.54 %, p = 0.028). In uni- and multivariate analyses including covariates, the only factor constantly and significantly associated with the rate of haemorrhage events was peri-interventional LMWH prophylaxis. Only one symptomatic lung embolism occurred in the entire cohort (NH-group). The 30- and 90-day mortalities were significantly greater in the H-group than in the NH-group.ConclusionsPeri-interventional LMWH thrombosis prophylaxis should be considered with caution. The rate of clinically relevant thrombotic events was extremely low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser Guidance in C-Arm Cone-Beam CT-Guided Radiofrequency Ablation of Osteoid Osteoma Reduces Fluoroscopy Time

PurposeTo assess whether laser guidance can reduce fluoroscopy and procedure time of cone-beam computed tomography (CBCT)-guided radiofrequency (RF) ablations of osteoid osteoma compared to freehand CBCT guidance.Materials and Methods32 RF ablations were retrospectively analyzed, 17 laser-guided and 15 procedures using the freehand technique. Subgroup selection of 18 ablations in the hip–pelvic region with a similar degree of difficulty was used for a direct comparison. Data are presented as median (ranges).ResultsComparison of all 32 ablations resulted in fluoroscopy times of 365 s (193–878 s) for freehand and 186 s (75–587 s) for laser-guided procedures (p = 0.004). Corresponding procedure times were 56 min (35–97 min) and 52 min (30–85 min) (p = 0.355). The subgroup showed comparable target sizes, needle path lengths, and number of scans between groups. Fluoroscopy times were lower for laser-guided procedures, 215 s (75–413 s), compared to 384 s (193–878 s) for freehand (p = 0.012). Procedure times were comparable between groups, 51 min (30–72 min) for laser guidance and 58 min (35–79 min) for freehand (p = 0.172).ConclusionAdding laser guidance to CBCT-guided osteoid osteoma RF ablations significantly reduced fluoroscopy time without increasing procedure time.Level of EvidenceLevel 4, case series.

62 RADIOLOGY AND NUCLEAR MEDICINE↗