Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AAAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

A non-radioactive method for measuring Rubisco activase activity in the presence of variable ATP: ADP ratios, including modifications for measuring the activity and activation state of Rubisco

Rubisco (ribulose-1,5-bisphosphate carboxylase/oxygenase) catalyzes carboxylation of ribulose-1,5- bisphosphate, the first in a series of reactions leading to the incorporation of atmospheric CO2 into biomass. Rubisco requires Rubisco activase (RCA), an AAA? ATPase that reactivates Rubisco by remodelling the conformation of inhibitor-bound sites. RCA is regulated by the ratio of ADP:ATP, with the precise response potentiated by redox regulation of the alpha-isoform. Measuring the effects of ADP on the activation of Rubisco by RCA using the wellestablished photometric assay is problematic because of the adenine nucleotide requirement of 3-phosphoglycerate (3- PGA) kinase. Described here is a novel assay for measuring RCA activity in the presence of variable ratios of ADP:ATP. The assay couples the formation of 3-PGA from ribulose 1,5-bisphosphate and CO 2 to NADH oxidation through cofactor-dependent phosphoglycerate mutase, enolase, PEP carboxylase and malate dehydrogenase. The assay was used to determine the effects of Rubisco and RCA concentration and ADP:ATP ratio on RCA activity, and to measure the activation of a modified Rubisco by RCA. Variations of the basic assay were used to measure the activation state of Rubisco in leaf extracts and the activity of purified Rubisco. The assay can be automated for high-throughput processing by conducting the reactions in two stages.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrification Analysis: All Aboard America!

This one-page highlight details the key takeaways from a project that utilized NREL's Fleet Research, Energy Data, and Insights (FleetREDI) data analysis pipeline, an electrification analysis for the Bustang motorcoach fleet operated by All Aboard America! Holdings Inc. (AAA). NREL installed logging devices and collected operational data on nine 40-foot Bustang motorcoaches operating on fixed routes from May 2022 through August 2022. The analysis determined that partial fleet electrification may be feasible with electrified motorcoach options currently on the market. While this fleet faces significant challenges to electrification given current market options due to demanding range requirements and relatively limited charging opportunities, vehicles operating on the shorter, lower-grade routes along the I-25 corridor show more immediately available electrification potential. Increases in available battery capacity and the availability of fast-charging locations along I-70 routes are likely critical for electrification of the full fleet.

AAA↗

Orlando Auciello

Orlando Auciello talks about receiving AAAS fellowship and Argonne National Laboratory.

AAAS↗

Science Personality and STEM Ambassador

Dr. Amy Elliott has had unique opportunities to serve as a STEM role model through her various media production projects. Her debut on screen was as a competitor on an engineering reality show competition called “The Big Brain Theory,” aired by The Discovery Channel. Following this competition, Dr. Elliott served as an on-camera host for RoboNation’s water-based, annual collegiate competitions and for The Science Channel’s viral video show, “Outrageous Acts of Science.” Dr. Elliott also serves as volunteer pit-crew for Green Envy Racing, a woman-lead race team that seeks to set and speed records with electric motorcycles. Because of Dr. Elliott’s public exposure, she was selected as an IF/THEN Ambassador by the American Associate for the Advancement of Science (AAAS), a program that seeks to highlight women as STEM role models. Dr. Elliott’s work in 3D printing is frequently a source of inspiration for her.

Elliott, Amy↗

Final state rescattering effects in axio-hadronic η and η′ decays

It has been long-understood that final state rescattering effects provide (1) corrections to hadronic meson decays rates, such as η → πππ and η' → ηππ. Hence, one would expect that such effects would be just as important in axio-hadronic η and η' decays, such as η(') → ππa, where a is an axion or axion-like particle (ALP). And indeed they are, as we show in this paper by using the treatment of dispersion relations to include the effects of strong final state interactions in several axio-hadronic processes, namely, η(') → π 0 π 0 a, η(') → π+π-a, and η' → ηπ 0 a. We also compute the perturbative, leading order decay rates for multiple ALP emission, such as in η(') → π 0 aa, η' → ηaa and η(') → aaa, and briefly discuss the expected corrections from strong interactions and the processes that must be considered for an accurate rate estimation of these multi-ALP decay channels.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non-contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47-2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transgraft sac Embolization Combined with Graft Reinforcement for Refractory Mixed-Type Endoleak

An 80-year-old female underwent EVAR 4 years ago. She presented type II endoleak with sac expansion from 68 to 80 mm during 3-year follow-up after EVAR. Although she underwent translumbar percutaneous sac embolization, the AAA sac continued to enlarge, suggesting mixed-type endoleak including type I, II, and III. Transgraft direct sac angiography revealed endoleak cavity without demonstrable feeding vessel. Transgraft sac embolization using n-butyl cyanoacrylate and graft reinforcement was performed concurrently, without complications. The graft reinforcement consisted of graft extension for eliminating occult type I endoleak, and relining for eliminating occult type III endoleak. Six months after the procedure, CT showed no signs of sac expansion. Transgraft sac embolization combined with graft reinforcement is one of the available options for persistent and refractory mixed-type endoleak.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Onyx Embolization for Occlusion of the Proximal Internal Iliac Artery During EVAR in Patients with Unsuitable Landing Zones in the Common Iliac Artery

Background: Twenty percent of the patients with AAA have an aneurysm involving the common iliac arteries. Large common iliac diameter can be treated with an iliac branched device or extension of the stent graft to the external iliac artery with occlusion of the ipsilateral internal iliac artery (IIA) to prevent type 2 endoleaks. This study describes and evaluates a embolization technique using Onyx in conjunction with EVAR in aneurysms with poor landing zones in the common iliac arteries. Methods: Patients with Onyx IIA embolization during EVAR, identified from the hospital operating code database, constitute the study population. Onyx embolization was performed by injection at the IIA origin. Peri- and postoperative complications were collected from the medical records. Thin-sliced CT scan was performed 1 month and 1 year after the procedure. Results: Thirty-six patients with complex iliac anatomy and insufficient landing zones (without sealing possibility for standard stent grafts) were identified out of 243 consecutive EVAR treatments during a 13-year period. In seventeen patients (7%), the IIA was embolized with Onyx. Technical success was obtained in all 17 patients, without adverse event or procedural complication. No complication related to the embolization procedure was noted during follow-up. Conclusions: During EVAR treatment of patients with aneurysm involving the common iliac artery, Onyx embolization of IIA is a feasible option without need of selective catheterization of the IIA orifice, potentially preserving important branches of the IIA and simplifying emergency procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intramolecular Hydrogen Transfer from the Alpha-Carbon (Cα) and Backbone Amide Nitrogen (N{sub b}) to Form c- and y-Ions in Negative-Ion CID of Peptides

The source of hydrogen in the formation of c- and y-ions produced by intramolecular hydrogen transfer in negative-ion CID experiments with peptides has been examined using Cα-, Cβ-, and backbone amide (N{sub b})-deuterated peptides AAA(d3)AA, AAG(d2)AA, AAAG(d2)A, and AAAAA-d7, as well as five other peptides. The c- and y-ions produced by deuterium transfer from the deuterated residues were detected and identified by the exact m/z values obtained with a high-resolution orbitrap mass spectrometer. The rate of deuterium transfer obtained indicates that over 50% of the hydrogen was originated from the backbone amide nitrogen, with the residual hydrogen coming from the backbone Cα. It is clear that the hydrogen does not originate from the side chain Cβ. It is hypothesized that the intramolecular hydrogen transfer to form negative c- and y-ions takes place via 3-, 4-, 6-, 7-, 8-, and 9-membered ring transition states. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Structure and expression of a novel compact myelin protein – Small VCP-interacting protein (SVIP)

Highlights: •SVIP (small p97/VCP-interacting protein) co-localizes with myelin basic protein (MBP) in compact myelin. •We determined that SVIP is an intrinsically disordered protein (IDP). •The helical content of SVIP increases dramatically during its interaction with negatively charged lipid membrane. •This study provides structural insight into interactions between SVIP and myelin membranes. -- Abstract: SVIP (small p97/VCP-interacting protein) was initially identified as one of many cofactors regulating the valosin containing protein (VCP), an AAA+ ATPase involved in endoplasmic-reticulum-associated protein degradation (ERAD). Our previous study showed that SVIP is expressed exclusively in the nervous system. In the present study, SVIP and VCP were seen to be co-localized in neuronal cell bodies. Interestingly, we also observed that SVIP co-localizes with myelin basic protein (MBP) in compact myelin, where VCP was absent. Furthermore, using nuclear magnetic resonance (NMR) and circular dichroism (CD) spectroscopic measurements, we determined that SVIP is an intrinsically disordered protein (IDP). However, upon binding to the surface of membranes containing a net negative charge, the helical content of SVIP increases dramatically. These findings provide structural insight into interactions between SVIP and myelin membranes.

60 APPLIED LIFE SCIENCES↗

Cryo-EM of the pathogenic VCP variant R155P reveals long-range conformational changes in the D2 ATPase ring

Single amino acid mutations in valosin containing protein (VCP/p97), a highly conserved member of the ATPases associated with diverse cellular activities (AAA) family of ATPases has been linked to a severe degenerative disease affecting brain, muscle and bone tissue. Previous studies have demonstrated the role of VCP mutations in altering the ATPase activity of the D2 ring; however the structural consequences of these mutations remain unclear. In this study, we report the three-dimensional (3D) map of the pathogenic VCP variant, R155P, as revealed by single-particle Cryo-Electron Microscopy (EM) analysis at 14 Å resolution. We show that the N-terminal R155P mutation induces a large structural reorganisation of the D2 ATPase ring. Results from docking studies using crystal structure data of available wild-type VCP in the EM density maps indicate that the major difference is localized at the interface between two protomers within the D2 ring. Consistent with a conformational change, the VCP R155P variant shifted the isoelectric point of the protein and reduced its interaction with its well-characterized cofactor, nuclear protein localization-4 (Npl4). Together, our results demonstrate that a single amino acid substitution in the N-terminal domain can relay long-range conformational changes to the distal D2 ATPase ring. Our results provide the first structural clues of how VCP mutations may influence the activity and function of the D2 ATPase ring. - Highlights: • p97{sub R155P} and p97{sub A232E} decrease the ability of p97 to bind to its co-factor Npl4. • p97{sub R155P} has a different isoelectric point than that of p97{sub R95G}, p97{sub A232E} and p97{sub WT}. • Mutation R155P changes principally the conformation of the D2 ring. • Mutation R155P modifies the interface between two protomers within the D2 ring.

60 APPLIED LIFE SCIENCES↗

The KYxxL motif in Rad17 protein is essential for the interaction with the 9–1–1 complex

ATR-dependent DNA damage checkpoint is the major DNA damage checkpoint against UV irradiation and DNA replication stress. The Rad17–RFC and Rad9–Rad1–Hus1 (9–1–1) complexes interact with each other to contribute to ATR signaling, however, the precise regulatory mechanism of the interaction has not been established. Here, we identified a conserved sequence motif, KYxxL, in the AAA+ domain of Rad17 protein, and demonstrated that this motif is essential for the interaction with the 9–1–1 complex. We also show that UV-induced Rad17 phosphorylation is increased in the Rad17 KYxxL mutants. These data indicate that the interaction with the 9–1–1 complex is not required for Rad17 protein to be an efficient substrate for the UV-induced phosphorylation. Our data also raise the possibility that the 9–1–1 complex plays a negative regulatory role in the Rad17 phosphorylation. We also show that the nucleotide-binding activity of Rad17 is required for its nuclear localization. - Highlights: • We have identified a conserved KYxxL motif in Rad17 protein. • The KYxxL motif is crucial for the interaction with the 9–1–1 complex. • The KYxxL motif is dispensable or inhibitory for UV-induced Rad17 phosphorylation. • Nucleotide binding of Rad17 is required for its nuclear localization.

60 APPLIED LIFE SCIENCES↗

Role of the σ 54 Activator Interacting Domain in Bacterial Transcription Initiation

Bacterial sigma factors are subunits of RNA polymerase that direct the holoenzyme to specific sets of promoters in the genome and are a central element of regulating transcription. Most polymerase holoenzymes open the promoter and initiate transcription rapidly after binding. However, polymerase containing the members of the σ 54 family must be acted on by a transcriptional activator before DNA opening and initiation occur. A key domain in these transcriptional activators forms a hexameric AAA + ATPase that acts through conformational changes brought on by ATP hydrolysis. Contacts between the transcriptional activator and σ 54 are primarily made through an N-terminal σ 54 activator interacting domain (AID). To better understand this mechanism of bacterial transcription initiation, we characterized the σ 54 AID by NMR spectroscopy and other biophysical methods and show that it is an intrinsically disordered domain in σ 54 alone. In this paper, we identified a minimal construct of the Aquifex aeolicus σ 54 AID that consists of two predicted helices and retains native-like binding affinity for the transcriptional activator NtrC1. Using the NtrC1 ATPase domain, bound with the non-hydrolyzable ATP analog ADP-beryllium fluoride, we studied the NtrC1–σ 54 AID complex using NMR spectroscopy. We show that the σ 54 AID becomes structured after associating with the core loops of the transcriptional activators in their ATP state and that the primary site of the interaction is the first predicted helix. Finally, understanding this complex, formed as the first step toward initiation, will help unravel the mechanism of σ 54 bacterial transcription initiation.

60 APPLIED LIFE SCIENCES↗

The microwave spectra of the conformers of $\mathcal{n}$-butyl nitrate

We report the microwave spectrum of n-butyl nitrate was recorded in the 5 to 20 GHz frequency range using broadband chirp and narrowband pulse excitation molecular jet Fourier transform microwave spectrometers. A quantum chemistry structural analysis yielded thirteen stable conformers. Among them, the five most energetically stable conformers were observed in the experimental spectra. The most stable conformer features a butyl chain with an anti-gauche-anti conformation (AGA) where the γ-carbon atom is about 64° out of the nitrate plane. For this conformer, spectra of all 13 C and 15 N minor isotopologues could be measured. The conformer with a straight butyl chain (AAA), and three other conformers (GAA, GGA, and AGG) were also observed. Accurate rotational constants, centrifugal distortion constants, and 14 N nuclear quadrupole coupling constants could be deduced and compared to the theoretical values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement and Evaluation of Inhomogeneity Corrections and Monitor Unit Verification for Treatment Planning

Heterogeneous lung and bone phantoms have been constructed for the purpose of testing monitor unit calculations at or near interfaces for different planning systems. Data have been acquired for 2 linear accelerators: a Varian 2300cd (6 and 25 MV) and an Elekta Synergy (6, 10, and 18 MV). We have reviewed Pinnacle and the correction-based, pre-AAA version of Eclipse planning systems with the intent of exploring the limits of these systems with energy and field size. Data were acquired from 2 x 2 to 10 x 10 cm{sup 2} field sizes over the available range of energies. Our measurements confirm that Pinnacle predicts doses mostly to within {+-} 5%, even near lung-tissue interfaces over the full range of energies and field sizes tested. The Eclipse-modified Batho and equivalent TMR algorithms overpredicted doses by 10% or more in the lung and near the lung-tissue interfaces if the field size was less than 10 x 10 cm{sup 2} when the energy was 18 MV or higher. At lower energies, the field size had to be at least 6 x 6 cm{sup 2} for calculated doses to be within 10% of measurement. For bone-tissue interfaces, doses were generally underestimated by 5% to 10% or more by all calculation methods over the range of field sizes and energies reviewed. A second goal of this study was to review methods for hand-checking monitor units when heterogeneities are included. We evaluated the range of applicability of 2, one-dimensional (1D) inhomogeneity correction factors: the effective attenuation method and the TMR ratio method. The effective attenuation method for monitor unit checking was within {+-} 5% to as small as 6 x 6 cm{sup 2} fields for 6 to 10 MV, useable for 4 x 4 cm{sup 2} fields (within 7%) for 6 MV and close to {+-} 5% for 10 x 10 cm{sup 2} fields in the 18- to 25-MV range. The TMR ratio method was not as good, being within about {+-} 5% to 7% of measurements only for 6 x 6 to 10 x 10 cm{sup 2} fields at 6 MV and 10 x 10 cm{sup 2} fields at the higher energies. Both simple 1D correction methods performed almost as well as Pinnacle for the bone-soft tissue cases. We recommend that if direct measurement of dose for heterogeneous treatment plans is not practiced, then one of these simple cross checks be performed to assure patient safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer

The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the {gamma} function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated significant differences in 2 of 4 patients. Disagreement in the lung region was also found when the {Gamma} analysis was performed. The effect on TCP is less important than for NTCP because of the slope of the curve at the level of the dose of interest. The effect of dose calculation inaccuracy is patient-dependent and strongly related to beam geometry and to the localization of the tumor. When multiple intensity-modulated beams are used, the effect of the presence of the heterogeneity on dose distribution may not always be easily predictable.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of differences in calculated and actual measured skin doses to canine limbs during stereotactic radiosurgery using Gafchromic film

Accurate calculation of absorbed dose to the skin, especially the superficial and radiosensitive basal cell layer, is difficult for many reasons including, but not limited to, the build-up effect of megavoltage photons, tangential beam effects, mixed energy scatter from support devices, and dose interpolation caused by a finite resolution calculation matrix. Stereotactic body radiotherapy (SBRT) has been developed as an alternative limb salvage treatment option at Colorado State University Veterinary Teaching Hospital for dogs with extremity bone tumors. Optimal dose delivery to the tumor during SBRT treatment can be limited by uncertainty in skin dose calculation. The aim of this study was to characterize the difference between measured and calculated radiation dose by the Varian Eclipse (Varian Medical Systems, Palo Alto, CA) AAA treatment planning algorithm (for 1-mm, 2-mm, and 5-mm calculation voxel dimensions) as a function of distance from the skin surface. The study used Gafchromic EBT film (International Specialty Products, Wayne, NJ), FilmQA analysis software, a limb phantom constructed from plastic water Trade-Mark-Sign (fluke Biomedical, Everett, WA) and a canine cadaver forelimb. The limb phantom was exposed to 6-MV treatments consisting of a single-beam, a pair of parallel opposed beams, and a 7-beam coplanar treatment plan. The canine forelimb was exposed to the 7-beam coplanar plan. Radiation dose to the forelimb skin at the surface and at depths of 1.65 mm and 1.35 mm below the skin surface were also measured with the Gafchromic film. The calculation algorithm estimated the dose well at depths beyond buildup for all calculation voxel sizes. The calculation algorithm underestimated the dose in portions of the buildup region of tissue for all comparisons, with the most significant differences observed in the 5-mm calculation voxel and the least difference in the 1-mm voxel. Results indicate a significant difference between measured and calculated data extending to average depths of 2.5 mm, 3.4 mm, and 10 mm for the 1-mm, 2-mm, and 5-mm dimension calculation matrices, respectively. These results emphasize the importance of selecting as small a treatment planning software calculation matrix dimension as is practically possible and of taking a conservative approach for skin treatment planning objectives. One suggested conservative approach is accomplished by defining the skin organ as the outermost 2-3 mm of the body such that the high dose tail of the skin organ dose-volume histogram curve represents dose on the deep side of the skin where the algorithm is more accurate.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Molecular Basis of N-End Rule Recognition

The N-end rule targets specific proteins for destruction in prokaryotes and eukaryotes. Here, we report a crystal structure of a bacterial N-end rule adaptor, ClpS, bound to a peptide mimic of an N-end rule substrate. This structure, which was solved at a resolution of 1.15 {angstrom}, reveals specific recognition of the peptide {alpha}-amino group via hydrogen bonding and shows that the peptide's N-terminal tyrosine side chain is buried in a deep hydrophobic cleft that pre-exists on the surface of ClpS. The adaptor side chains that contact the peptide's N-terminal residue are highly conserved in orthologs and in E3 ubiquitin ligases that mediate eukaryotic N-end rule recognition. We show that mutation of critical ClpS contact residues abrogates substrate delivery to and degradation by the AAA+ protease ClpAP, demonstrate that modification of the hydrophobic pocket results in altered N-end rule specificity, and discuss functional implications for the mechanism of substrate delivery.

08 HYDROGEN↗