Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 199 records · Page 11

Plastic shrinkage of mortars cured with a paraffin-based compound – Bimodal neutron/X-ray tomography study

Early-age drying (immediately after casting) of mortars and the corresponding plastic shrinkage were studied using bimodal neutron/X-ray computed tomography. This novel, correlative 3D imaging mode enabled studying simultaneously and without any source of spurious perturbation the water migration and loss processes together with the corresponding deformations due to plastic shrinkage. Bimodal imaging opens up new possibilities for studying dynamic processes of coupled water transport and deformations in porous solids. The measurements were carried out on model systems (cylindrical mortar specimens with height of 19 mm). The study focused on the effect of a paraffin-based curing compound. Our results confirm that when the curing compound was applied directly onto the drying surface in a sufficient amount, both the evaporation rate and the rate of vertical displacement (settlement) were substantially reduced. The results shed a new light on the mechanisms of plastic shrinkage and the action of curing compounds.

36 MATERIALS SCIENCE↗

SU-E-P-12: Pinnacle-Based Tool to Evaluate the Effect of Prostate Rotation as Determined by Calypso

Purpose: When the Calypso reports a large prostate rotation and one does not have the means to make corrections, it is helpful to quantify its dosimetric effects. We have devised a simple scheme to achieve this in Pinnacle TPS. If it is determined that the PTV margin is inadequate, an alternate larger-margin plan may be adapted for the day. Methods: A three-step process using the Pinnacle Image fusion module was formulated to analyze the clinical effect of prostate rotation. The process includes (1) translating the image set such that the rotational axis is about the isocenter, (2) performing 3D rotations of the structures of interest, and (3) restoring the coordinates associated with the plan. The rotated structures are imported and overlayed on the original plan for evaluation. The tool was applied to three prostate cancer patients with relatively large rotations (95 fractions total). Prostate rotations are primarily due to variations in bladder and rectal filling, which may also affect the seminal vesicles. It is difficult to estimate the perturbation of seminal vesicles for a given prostate rotation. Therefore, the Calypso-derived rotation matrix was applied only to CTV and PTV (CTV+5mm). Results: The rotations were predominantly in the pitch direction with an absolute value ranging from 0–29 degrees (Median = 10°, Average = 14.5°). For various magnitudes of rotation, the CTV V100 decreased from the original 100% to 99.6%/99%/95% for 10°/15°/29° rotations, respectively. Likewise, the PTV V100 diminished from 95% to 92%/89%/82%. Conclusion: A tool, consisting only of features within a TPS, was used to evaluate the dosimetric effect of prostate rotation. Our study shows that under large uncorrected rotations, the tumor coverage is degraded and may require intervention in the form of plan adaptation. To this end, alternate plans with variable margins can be generated in advance for daily adaption.

60 APPLIED LIFE SCIENCES↗

SU-E-J-45: The Correlation Between CBCT Flat Panel Misalignment and 3D Image Guidance Accuracy

Purpose To simulate the impact of CBCT flat panel misalignment on the image quality, the calculated correction vectors in 3D image guided proton therapy and to determine if these calibration errors can be caught in our QA process. Methods The X-ray source and detector geometrical calibration (flexmap) file of the CBCT system in the AdaPTinsight software (IBA proton therapy) was edited to induce known changes in the rotational and translational calibrations of the imaging panel. Translations of up to ±10 mm in the x, y and z directions (see supplemental) and rotational errors of up to ±3° were induced. The calibration files were then used to reconstruct the CBCT image of a pancreatic patient and CatPhan phantom. Correction vectors were calculated for the patient using the software’s auto match system and compared to baseline values. The CatPhan CBCT images were used for quantitative evaluation of image quality for each type of induced error. Results Translations of 1 to 3 mm in the x and y calibration resulted in corresponding correction vector errors of equal magnitude. Similar 10mm shifts were seen in the y-direction; however, in the x-direction, the image quality was too degraded for a match. These translational errors can be identified through differences in isocenter from orthogonal kV images taken during routine QA. Errors in the z-direction had no effect on the correction vector and image quality.Rotations of the imaging panel calibration resulted in corresponding correction vector rotations of the patient images. These rotations also resulted in degraded image quality which can be identified through quantitative image quality metrics. Conclusion Misalignment of CBCT geometry can lead to incorrect translational and rotational patient correction vectors. These errors can be identified through QA of the imaging isocenter as compared to orthogonal images combined with monitoring of CBCT image quality.

60 APPLIED LIFE SCIENCES↗

Development of a statistical model (tool) for classifying buried object detectability

To improve warfighter safety under changing requirements, assets must be adaptable and able to detect and mark buried hazards. Current GPR systems would benefit by improvements in speed, usability, and operational versatility to enhance operational effectiveness for all platforms and missions. Our sponsor requests that LLNL research GPR methodologies and approaches to allow for specific improvements to be made in those areas. MiRadar uses a novel multi-static array architecture coupled with tomographic processing to focus returned energy from the real (physical) and synthetic (motion-derived) apertures. 3D streaming movies of the subsurface are easily interpreted, slashing training times. Real-time processing codes enable imaging and operation three times faster; automated volumetric detection algorithms warn of possible hazards. In a two-week trial, multiple vehicle-mounted arrays and a new ultralightweight architecture on a small, unmanned aircraft system executed 498 runs, collecting over 400km of data on 13 preemplaced lanes containing 384 simulated buried threats.

42 ENGINEERING↗

Enhanced FIB-SEM systems for large-volume 3D imaging

Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 10 6 ?m 3 . These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processes and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology.

59 BASIC BIOLOGICAL SCIENCES↗

Effects of pore-scale precipitation on permeability and flow

Here, the effects of calcite precipitation on porous media permeability and flow were evaluated with a combined experimental and modeling approach. X-ray microtomography images of two columns packed with glass beads and calcite (spar crystals) or aragonite (Bahamas ooids) injected with a supersaturated solution (log Ω = 1.42) were processed in order to calculate rates of calcite precipitation with a spatial resolution of 4.46 µm. Identification and localization of the newly precipitated crystals on the 3D images was performed and results used to calculate the crystal growth rates and velocities. The effects of carbonate precipitation were also evaluated in terms of the integrated precipitation rate over the length of the column, crystal shape, surface area and pore roughness changes. While growth was epitaxial on calcite spar, calcite rhombohedra formed on glass beads and clusters of polyhedrons formed on aragonite ooids. Near the column inlet, calcite precipitation occurred preferentially on carbonate grains compared to glass beads, with almost 100% of calcite spar surface area covered by new crystals versus 92% in the case of aragonite and 11% in the case of glass beads. Although the experimental chemistry and flow boundary conditions in the two columns were similar, their porosity-permeability evolution was different because the nucleation and subsequent crystal growth on the two substrates (i.e., calcite spar and aragonite ooids) was very different. The impact of mineral precipitation on pore-scale flow and permeability was evaluated using a pore-scale Stokes solver that accounted for the changes in pore geometry. For similar magnitude reductions in porosity, the decrease in permeability was highest within the sample that experienced the greatest increase in pore roughness. Various porous media models were generated to show the impact of different crystal growth patterns and pore roughness changes on flow and permeability-porosity relationship. Under constant flow rate boundary conditions, precipitation resulted in an increase in both the average and maximum velocities. Increases in pore roughness led to a more heterogeneous flow field, principally through the effects on the fastest and slowest velocities within the domain.

58 GEOSCIENCES↗

Pore2Chip: All-in-one python tool for soil microstructure analysis and micromodel design

The Pore2Chip Python package is designed to create 2D micromodels using extracted data from 3D X-ray computed tomography (XCT) images. This package helps analyze soil structure and function, allowing for the investigation of hydro-biogeochemical processes that impact mineral extraction and reactivity, oxygen concentrations, and nutrient availability in disturbed or managed soils. Key metrics encompass pore size distributions, pore throat size distributions, and connectivity (pore coordination numbers). The final output is a 2D scalable SVG design representing a core or aggregate. Designs can be fabricated with methods such as laser etching, 3D printing, and photolithography.

lab-on-chip↗

A Preliminary Comparison of Three Dimensional Particle Tracking and Sizing using Plenoptic Imaging and Digital In-line Holography

Digital in-line holography and plenoptic photography are two techniques for single-shot, volumetric measurement of 3D particle fields. Here we present a preliminary comparison of the two methods by applying plenoptic imaging to experimental configurations that have been previously investigated with digital in-line holography. These experiments include the tracking of secondary droplets from the impact of a water drop on a thin film of water and tracking of pellets from a shotgun. Both plenoptic imaging and digital in-line holography successfully quantify the 3D nature of these particle fields. This includes measurement of the 3D particle position, individual particle sizes, and three-component velocity vectors. For the initial processing methods presented here, both techniques give out-of-plane positional accuracy of approximately 1-2 particle diameters. For a fixed image sensor, digital holography achieves higher effective in-plane spatial resolutions. However, collimated and coherent illumination makes holography susceptible to image distortion through index of refraction gradients, as demonstrated in the shotgun experiments. On the other hand, plenotpic imaging allows for a simpler experimental configuration. Furthermore, due to the use of diffuse, white-light illumination, plenoptic imaging is less susceptible to image distortion in the shotgun experiments. Additional work is needed to better quantify sources of uncertainty, particularly in the plenoptic experiments, as well as develop data processing methodologies optimized for the plenoptic measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Preliminary Comparison of Three Dimensional Particle Tracking and Sizing using Plenoptic Imaging and Digital In-line Holography [PowerPoint]

Digital in-line holography and plenoptic photography are two techniques for single-shot, volumetric measurement of 3D particle fields. Here we present a preliminary comparison of the two methods by applying plenoptic imaging to experimental configurations that have been previously investigated with digital in-line holography. These experiments include the tracking of secondary droplets from the impact of a water drop on a thin film of water and tracking of pellets from a shotgun. Both plenoptic imaging and digital in-line holography successfully quantify the 3D nature of these particle fields. This includes measurement of the 3D particle position, individual particle sizes, and three-component velocity vectors. For the initial processing methods presented here, both techniques give out-of-plane positional accuracy of approximately 1-2 particle diameters. For a fixed image sensor, digital holography achieves higher effective in-plane spatial resolutions. However, collimated and coherent illumination makes holography susceptible to image distortion through index of refraction gradients, as demonstrated in the shotgun experiments. On the other hand, plenotpic imaging allows for a simpler experimental configuration. Furthermore, due to the use of diffuse, white-light illumination, plenoptic imaging is less susceptible to image distortion in the shotgun experiments. Additional work is needed to better quantify sources of uncertainty, particularly in the plenoptic experiments, as well as develop data processing methodologies optimized for the plenoptic measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of X-ray computed tomography for the characterization of graphite morphology in compact-graphite iron

Highlights: • X-ray Tomography is a powerful technique for graphite morphology characterization. • 3D characterization reveals true nodularity and spatial connectivity of graphite. • Tri-modal distribution of SG suggests a multi-stage graphite nucleation process. - Abstract: In the present study, high-energy X-ray tomography technique was used to characterize the graphite morphology of compact graphite iron. The size, shape, spatial connectivity and structure of different graphite morphologies were examined in 3D using computer-aided image analysis. In addition, nodularity analysis was performed in 3D and the results are compared to the traditional 2D technique. It is found that the variation of nodularity within 2 × 2 × 1.2 mm{sup 3} of the sample can be as high as 20 (%) from 2D analysis and the averaged nodularity (2D) is higher than that from 3D analysis. The size distribution of spheroidal graphite shows a tri-modal distribution, which suggests a multi-step nucleation process during solidification.

36 MATERIALS SCIENCE↗

Non-Destructive, Three-Dimensional Imaging of Processes in the Rhizosphere Utilizing High Energy Photons

Soil structure, which can be described as the aggregation and distribution of pore spaces, regulates carbon, nutrient, and water cycling across the Earth system. Yet the inability to make quantitative, dynamic, in situ measurements of soil structure and rhizosphere carbon flow has prevented meaningful incorporation of soil structural processes into Earth System Models (ESMs). The key limitations are: (i) Lack of scale integration between micron-scale soil structure and ecosystem-scale models, (ii) Poor functional linkage between soil structural properties and biogeochemical processes, and (iii) Absence of dynamic 3D measurements of rhizosphere structural changes and carbon transformations. To address these challenges, we developed a new integrated positron emission tomography (PET) - microcomputed tomography (CT) imaging platform that enables the first 4D (spatial 3D and time), non-invasive, quantitative imaging of carbon allocation and rhizosphere structural dynamics in living plants and intact soils. The system combines: • Rhizo-PET (R-PET): a high-resolution positron emission tomography scanner optimized for 11 CO 2 tracing in plant roots. • a-Se micro-CT: a high-contrast, high-spatial resolution CT system based on amorphous selenium (a-Se) direct conversion technology, enabling micron-scale visualization of soil structure and root–soil interfaces. Together, these advances allow us to quantify how carbon exudates move, transform, and stabilize within the rhizosphere, directly informing missing processes in BER-relevant carbon cycle models.

42 ENGINEERING↗

Aerial Captured Data and Processed Models in Beaumont-Port Arthur Region in Feb and Oct, 2023

Our Co-design team is from the University of Texas, working on a Department of Energy-funded project focused on the Beaumont-Port Arthur area. As part of this project, we will be developing climate-resilient design solutions for areas of the region. More on www.caee.utexas.edu.We used a DJI Mavic 2 Pro to capture aerial photos in Beaumont-Port Arthur, TX, in February 2023, including:I. Beaumont Soccer ClubII. Corps’ Port Arthur Resident OfficeIII. Halbouty Pump Station comprises its vicinityIV. Lamar University (Including Exxon Power Plants close to Lamar Univ.)V. MLK Boulevard for aerial images of the industry and the ship channelVI. Salt Water Barrier (include some aerial images about the Big Thicket)Aerial photos taken were through DroneDeploy autonomous flight, and models were processed through the DroneDeploy engine as well. All aerial photos are in .JPG format and contained in zipped files for each location.The processed data package including 3D models, geospatial data, mappings, point clouds, and the animation video of Halbouty Pump Station has various file types:- The Adobe Suite gives you great software to open .Tif files.- You can use LASUtility (Windows), ESRI ArcGIS Pro (Windows), or Blaze3D (Windows, Linux) to open a LAS file and view the data it contains.- Open an .OBJ file with a large number of free and commercial applications. Some examples include Microsoft 3D Builder, Apple Preview, Blender, and Autodesk.- You may use ArcGIS, Merkaartor, Blender (with the Google Earth Importer plug-in), Global Mapper, and Marble to open .KML files.- The .tfw world file is a text file used to georeference the GeoTIFF raster images, like the orthomosaic and the DSM. You need suitable software like ArcView to open a .TFW file.This dataset provides researchers with sufficient geometric data and the status quo of the land surface at the locations mentioned above. This dataset could streamline researchers' decision-making processes and enhance the design as well.In October 2023, we had our follow-up data collection, including:I. Beaumont Soccer ClubII. Shipping and Receiving Center at Lamar UniversityAfter the aerial collection, we obtained aerial photos of those two locations mentioned above, as well as processed data (such as point clouds and models).

2D mapping↗

Pixel multiplexing technique for real-time three-dimensional-imaging laser detection and ranging system using four linear-mode avalanche photodiodes

The avalanche-photodiode-array (APD-array) laser detection and ranging (LADAR) system has been continually developed owing to its superiority of nonscanning, large field of view, high sensitivity, and high precision. However, how to achieve higher-efficient detection and better integration of the LADAR system for real-time three-dimensional (3D) imaging continues to be a problem. In this study, a novel LADAR system using four linear mode APDs (LmAPDs) is developed for high-efficient detection by adopting a modulation and multiplexing technique. Furthermore, an automatic control system for the array LADAR system is proposed and designed by applying the virtual instrumentation technique. The control system aims to achieve four functions: synchronization of laser emission and rotating platform, multi-channel synchronous data acquisition, real-time Ethernet upper monitoring, and real-time signal processing and 3D visualization. The structure and principle of the complete system are described in the paper. The experimental results demonstrate that the LADAR system is capable of achieving real-time 3D imaging on an omnidirectional rotating platform under the control of the virtual instrumentation system. The automatic imaging LADAR system utilized only 4 LmAPDs to achieve 256-pixel-per-frame detection with by employing 64-bit demodulator. Moreover, the lateral resolution is ∼15 cm and range accuracy is ∼4 cm root-mean-square error at a distance of ∼40 m.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An advanced joint inversion system for CO 2 storage modeling with large date sets for characterization and real-time monitoring-enhancing storage performance and reducing failure risks under uncertainties

As large-scale, commercial storage projects become operational, the problem of utilizing information from diverse sources becomes more critically important. In this project, we developed, tested, and applied an advanced joint data inversion system for CO 2 storage modeling with large data sets for use in site characterization and real-time monitoring. Emphasis was on the development of advanced and efficient computational algorithms for joint inversion of hydro-geophysical data, coupled with state-of-the-art forward process simulations. The developed system consists of (1) inversion tools using characterization data, such as 3D seismic survey (amplitude images), borehole log and core data, as well as hydraulic, tracer and thermal tests before CO 2 injection, (2) joint inversion tools for updating the geologic model with the distribution of rock properties, thus reducing uncertainty, using hydro-geophysical monitoring data, and (3) highly efficient algorithms for directly solving the dense or sparse linear algebra systems derived from the joint inversion. The system combines methods from stochastic analysis, fast linear algebra, and high performance computing. The developed joint inversion tools have been tested through synthetic CO 2 storage examples.

01 COAL, LIGNITE, AND PEAT↗

Final Technical Report: Application of in situ Neutron Diffraction to Understand the Mechanism of Phase Transitions

In this research, phase transitions in the bulk electrodes for Li-ion batteries were investigated using neutron diffraction (ND) as well as neutron imaging techniques. The objectives of this research is to design of a novel in situ electrochemical cell to obtain Rietveld refinable neutron diffraction experiments using small volume electrodes of various laboratory/research-scale electrodes intended for Li-ion batteries. This cell is also to be used to investigate the complexity of phase transitions in Li(Mg) alloy electrodes, either by diffraction or by neutron imaging, which occur under electrochemical lithiation and delithiation, and to determine aspects of phase transition that enable/limit energy storage capacity. Additional objective is to investigate the phase transitions in electrodes made of etched micro-columns of silicon and investigate the effect of particle/column size on phase transitions and nonequilibrium structures. An in situ electrochemical cell was designed successfully and was used to study the phase transitions under in-situ neutron diffraction in both the electrodes (anode/cathode) simultaneously in graphite/LiCoO 2 and in graphite/LiMn 2 O 4 cells each with two cells. The diffraction patterns fully validated the working of the in situ cell. Additional experimental were performed using the Si micro-columnar electrodes. The results revealed new lithiation phenomena, as evidenced by mosaicity formation in silicon electrode. These experiments were performed in Vulcan diffractometer at SNS, Oak Ridge National Laboratory. In parallel, the spatial distribution of Li during lithiation and delithiation processes in Li-battery electrodes were investigated. For this purpose, neutron tomographic imaging technique has been used for 3D mapping of Li distribution in bulk Li(Mg) alloy electrodes. It was possible to observe the phase boundary of Li(Mg) alloy indicating phase transition from Li-rich BCC β-phase to Li-lean α-phase. These experiments have been performed at CG-1D Neutron Imaging Prototype Station at SNS.

25 ENERGY STORAGE↗

Mesh Generation for Microstructures

A parallel, adaptive overlay grid procedure is proposed for use in generating all-hex meshes for stochastic (SVE) and representative (RVE) volume elements in computational materials modeling. The mesh generation process is outlined including several new advancements such as data filtering to improve mesh quality from voxelated and 3D image sources, improvements to the primal contouring method for constructing material interfaces and pillowing to improve mesh quality at boundaries. We show specific examples in crystal plasticity and syntactic foam modeling that have benefitted from the proposed mesh generation procedure and illustrate results of the procedure with several practical mesh examples.

36 MATERIALS SCIENCE↗

Attention-based 3D – convolutional neural network model for mechanical property predictions using visible light images in metal additive manufacturing

Additive manufacturing (AM), while commonly used for rapid prototyping and creating components with complex geometries, has not been widely adopted for critical applications across the aerospace, automotive, defense, energy, and medical industries. This is, in part, due to the challenges of controlling flaws and uncertainty in the mechanical behavior of additively manufactured components. In recent years, there has been an increase in research aimed at predicting the final mechanical properties of additively manufactured components during the printing process. To address these issues, a 3D-CNN model was trained using low-cost in situ visible-light camera data, anomaly classifications, and the chosen process parameters to predict the ultimate tensile strength (UTS), yield strength (YS), total elongation (TE), and uniform elongation (UE). The 3D-CNN layers of the model employed attention mechanisms to prioritize features in the data, thereby improving prediction accuracy. Furthermore, the effect of each process parameter and anomaly class is investigated using attention-based dynamic sigmoid weighted gates to interpret the influence each class has on the final prediction. Different combinations of the in situ data were fed into the 3D-CNN, with varying amounts of image layers, to determine the ideal combination for predicting mechanical properties in situ. Here, the 3D-CNN model achieved mean absolute percentage errors (MAPE) below 5% for both UTS and YS while using only a single camera input and under half of the available image layers.

36 MATERIALS SCIENCE↗