Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “wind_speed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Synthesis of Post-fire Monitoring Activities in the Great Basin Desert, Mojave Desert, and Transition Zones

In the deserts of the American Southwest, fire return intervals of centuries to millennia are being replaced by fire return intervals of decades. This increased burn frequency has implications for post-closure management and long-term stewardship for Soils Corrective Action Units (CAUs) and Corrective Action Sites (CASs) on the Nevada National Security Site (NNSS), Tonopah Test Range, and Nevada Test and Training Range for which the U.S. Department of Energy (DOE), Environmental Management-Nevada (EM-NV) is responsible. For many CAUs and CASs, where closure-in-place alternatives were implemented or are being considered, there is a chance that these sites could burn over while they still pose a risk to the environment or human health given the long half-lives of some of the radionuclide contaminants of concern (COCs) (Shafer et al., 2007; Shafer and Gomes, 2009). Although it would have been ideal to conduct a fire-related study at a radionuclide contaminated site on the NNSS to determine how contaminated soils are transported post-fire, it was more practical to examine fires in environments analogous to where Soils Activity CAUs and CASs exist. Therefore, a series of studies were initiated at three radiologically uncontaminated analog sites to better understand the possible effects of wildfire on erosion and sediment transport by wind and water should vegetation at contaminated sites burn at the NNSS. The studies took place at the sites of the Gleason Fire, a prescribed burn that occurred near Ely, Nevada, which is in the Great Basin ecoregion; the White Rock Fire that occurred near Mesquite, Nevada, which is in the Mojave Desert ecoregion; and the Jacob Fire that occurred near Hiko, Nevada, in the transitional zone between the Great Basin Desert and the Mojave Desert. Each site was representative of one of the three ecoregions found on the NNSS. Erosion and vegetation characteristics were measured multiple times post-fire on both burned and unburned test plots at these study sites to compare and monitor the effects of fire over time. However, at the Mojave Desert site, there was an additional burn from nearly 25 years ago that was also compared with the more recent burned areas from 2013. Also, the time elapsed after the fire and the time when sampling began differed among the ecoregions. For example, at the Great Basin site, samples were collected prior to the fire and less than one month after the fire, whereas data collected at the Mojave Desert site did not occur until 22 months after the fire. The differences between the sample measurements and the time that elapsed after the fire may contribute to the variability in the data and the interpretations of the data. Runoff and water erosion were quantified through a series of rainfall and runoff simulation tests in which controlled amounts of water were delivered to the soil surface. Runoff data were collected from different microhabitats (e.g., undercanopies, interspace soils, ridges, and drainage areas). The data showed soil hydrophobicity (i.e., water repellency) on the Great Basin site for up to 12 months after the fire. The soil structure remained changed and weaker on the burned areas compared with the unburned areas for the three-year study period. Although runoff data at both the Great Basin site and transition zone site were highly variable, the post-fire runoff potential did not generally increase at either location after three years of monitoring. Mojave runoff did not differ much between fire ages or between burned and unburned areas, possibly because of the amount of vegetation growing on all three surfaces and because the fire intensity was likely lower relative to other ecoregions due to the amount of space between plants. Additionally, the measurements conducted on the Mojave fire occurred several years after the fire had burned and not within several months of the burn, which may also account for the lack of differences in runoff between burned and unburned locations. Wind erosion was assessed and quantified with a Portable In-Situ Wind ERosion Lab (PI-SWERL) on both the burned and unburned soils of different microhabitats (e.g., ridges, drainages, interspaces between plants, and plant undercanopies). Estimates of emissions (e.g., particulate matter with aerodynamic diameters less than or equal to 10 micrometers, or PM10) at different wind speeds were collected and filter samples were analyzed for chemical composition. The measurements among the fires were similar and the results of the wind erosion measurements indicate that there were seasonal influences on many parameters, but the potential for PM10 windblown dust emissions was higher on burned areas compared with unburned areas. Among the burned areas, drainages produced the most dust emissions, whereas burned ridges were the least emissive. Emissions at the Mojave site and transition zone site were similar between burned and unburned areas approximately three years after the respective fires. Emissions remained much greater on burned soils at the Great Basin site. However, site selection may have also contributed to the differences of emissions among the three study locations. Post-fire vegetation responses were documented for three years following each fire in different microhabitats (e.g., ridge, drainage, undercanopy, and interspace) at the Great Basin and transition zone sites. In 2013, at the Mojave fire site, random permanent plots were established in newly burned areas, areas that burned approximately 25 years ago, and an unburned control area. At each fire site, the regeneration of native plant species dominated the burned areas, but invasive annual grasses were present at each fire site. During the course of each three-year study, the invasive annual grasses increased in density or percentage at both the Great Basin and transition fire sites but not at the Mojave site, where annual invasive grasses remained high throughout the study period. However, the chronosequence data from the Mojave site indicate a transition to different invasive grass species with time. The post-burn vegetation at all three ecoregions is still in the early stages of succession, and shrub size should increase over time and shrub density should decrease over time. However, the recovery of the plant communities to pre-burn compositions may not occur for decades or centuries, or may not occur because of changes in climate and the presence of invasive annual grasses. Results from the three study locations suggested that contaminated soils on the NNSS that experienced wildfire had the potential for soil erosion and transport of contaminated soils. Both wind and soil runoff studies indicated that locations in the Great Basin and transition zone ecoregions were more susceptible to erosion than the Mojave Desert ecoregion, but the highest levels of erosion occurred during the early portions of the study (the first 24 months) and the Mojave Desert was not measured until 22 months after the burn. Additionally, data from the Great Basin indicated deeper soils may increase susceptibility to wind erosion. Historically, the Great Basin and transition zone ecoregions burned more frequently than the Mojave Desert because of fuel abundance and connectivity—and they continue to burn more frequently, particularly after the introduction of invasive grasses (Davies and Nafus, 2013). However, both ecoregions and the transition zone have burned with extensive, high-severity fires when certain weather and fuel conditions are met. For example, the high abundance and productivity of annual grasses and forbs—which are usually produced by above average winter precipitation—combined with early spring and summer warm, dry conditions. Future climate scenarios predict increased temperatures, variable to reduced precipitation, and larger, more extreme wildfires throughout western North America. These predictions suggest that future fires on the NNSS could increase in frequency, intensity, and severity similar to their analog ecosystems throughout the Great Basin and Mojave Desert (Dennison et al., 2014; Abatzoglou andWilliams, 2016; Westerling, 2016).

54 ENVIRONMENTAL SCIENCES↗

An Update to the SWiFT V27 Reference Model

A revised Sandia V27 reference model is provided for use with the wind turbine analysis code, FAST, incorporating refined parameters based on blade geometry measurements and performance data collected during the 2017 wake steering campaign at the Scaled Wind Farm Technology (SWiFT) site. The chord, twist, and airfoil section shapes were measured at five span locations on the blades of wind turbine WTGb1. The V27 AeroDyn file was updated with values equal to the measured chord and twist. The measured airfoil shapes deviated over the aft half of the chord compared to the original blade model NACA profiles. Differences in trailing edge camber were converted to an equivalent trailing edge flap effect calculated with thin airfoil theory. These mod- ified airfoil polars were updated in the V27 FAST model. The tip-speed-ratio and root bending moment were measured experimentally in the wake steering campaign at SWiFT on wind turbine WTGa1. The torque constant and collective pitch of the model were tuned so that the model output tip-speed-ratio and thrust, root bending moment matched the experiment across all wind speeds in region 2 operation with minimum error.

17 WIND ENERGY↗

SPE6 Atmospheric Lidar Data User Guide

The Wind Cube v2 is a vertically-profiling, remote sensing instrument based on pulsed Light Detection and Ranging (Lidar) technology that provideshigh quality wind measurements on par with an IEC calibrated meteorological mast. The instrument uses four radial laser beams (0, 90, 180, 270° in the azimuth, scan angle 28° from zenith) and one vertically (V) orientated beam to measure flow characteristics from 40 m up to 290 m above ground level at 12 user-programmable heights (Figure 1). Lidar creates a “virtual” meteorological tower whereby the characteristics of the wind in the lower part of the planetary boundary layer are sampled. It takes roughly 4 seconds to complete a full conical scan, followed by the 5thbeam (V) pointed in the vertical position. The underlying principle of pulsed lidar measurements of wind is the use of optical heterodyne (coherent) detection, in which laser pulses are transmitted into the atmosphere and scattered off of naturally-occurring small dust particles or aerosols entrained in the ambient flow field (Figure 2). Radial velocity is proportional to Doppler frequency shift. In simple to moderately complex terrain wind speed accuracy is 0.1 m/s, wind direction accuracy is 1.5°.

58 GEOSCIENCES↗

Multi-Physics Signature Field Experiment at LLNL's Site 300 (S300 FE): Atmospheric Sampling Technical Report

As a part of LLNL’s Local Venture’s field experiment (S300 FE), Site 300 was instrumented to determine the feasibility and methodology needed to detect an “atmospheric chemical signature” from an explosion. This objective was just one within a broader field campaign to collect multi-physics data for the Local Venture. LLNL leveraged two planned, above-ground shot events at B851’s open firing table in April 2017 which served as the explosive devices. Gas samples were taken using continuous in situ sensors and timed bag collection sampling. In situ collection of carbon monoxide (at the ppm level) was done with a Miran SapphIRe portable ambient air analyzer. The bag samples were taken using a “blue box” gas sampler. Collected bags were analyzed for multiple species using LLNL laboratory facilities. Observations of wind speed, direction, air pressure, air temperature, and relative humidity were taken at the Site 300 52 m tall meteorological tower.

54 ENVIRONMENTAL SCIENCES↗

Aerosol Observing System Surface Meteorology (AOSMET) Instrument Handbook

The aerosol observing system (AOS) surface meteorology instrument is an ancillary sensor that provides temperature, relative humidity, pressure, wind speed and direction, and precipitation data relevant to the AOS. It consists of a Vaisala weather transmitter (WXT520 or WXT530) mounted on top of the AOS aerosol inlet, at a height of approximately 10 meters.

54 ENVIRONMENTAL SCIENCES↗

Description and Analysis of the Hardware Safety Systems for the DOE/SNL SWiFT Wind Turbines

This report covers the design and analysis of the hardware safety systems of the DOE/SNL Scaled Wind Farm Technology facility wind turbines. An analysis of the stopping capability of the turbines in multiple scenarios is presented. Included are calculations of braking torque, simulations of high wind speed emergency stops including multiple fault scenarios, and comparisons of predicted turbine performance to the relevant design standards.

17 WIND ENERGY↗

Air Dispersion Modeling of Radioactive Releases During Proposed 236Z Rubble Pile Removal Activities

This report is part of the planning process for the removal of the 236Z rubble remaining as of January 1, 2018, at the Plutonium Finishing Plant (PFP) on the Hanford Site. This report documents an analysis considering standard techniques for the removal of demolition rubble. It does not document any decisions about the removal approaches. This document is intended to guide the establishment of a boundary for the application of an air monitoring regime. Atmospheric dispersion modeling using estimated release rates has been conducted to provide information on the location and levels of radioactive contamination that may be expected as the result of rubble removal activities. Hourly meteorological data collected over a 6-year period (2004–2009) were used to examine the effects of wind speed, direction, and stability on projected concentrations of contaminants in air and deposited on nearby surfaces. The source terms modeled in this report were based on the residual transuranic contamination levels that are anticipated to remain in the 236Z rubble following building demolition. The potential airborne concentrations were established using the five-factor formula from DOE-HDBK-3010 (DOE 1994) considering material-at-risk, damage ratio, airborne release fraction, respirable fraction, and leak path factor. Radioactive contamination emissions were calculated by release mechanism and rubble pile area for on-shift and off-shift activities. The emissions from the applicable sources were combined to provide emissions estimates for each day from each cleanup area. The U.S. Environmental Protection Agency’s (EPA’s) AERMOD computer code was used to estimate atmospheric dispersion and deposition of the released radioactive materials in the immediate vicinity of the planned rubble removal activities Both airborne and surface concentrations were modeled with AERMOD. Hourly derived air concentrations (DAC) were modeled for an array of receptors covering the rubble pile site and surrounding area. Peak (95th and 99th percentile) values of time-integrated air concentrations at these receptor points are derived from these hourly values, with modeling results reported as total incremental air concentrations in DAC-hours occurring over the selected time period. Total accumulated deposition amounts were also evaluated with AERMOD using the same array of receptors, with results reported as disintegrations per minute (dpm) per 100 cm2. Each rubble pile was considered in terms of its size, location, and estimated contamination levels. The modeling was based on the assumed sequence of the rubble removal activities. The results in this report are based on cleanup schedules and methods proposed by CHPRC. As of January 1, 2018, there are broadly three large rubble piles (west, footprint, and east) remaining of the 236Z Building process cell. It is assumed that the overall cleanup will require either 1) 30 days over a 6-week period, or 2) 60 days over a 12-week period. Work was assumed to be performed during 10-hour day shifts. The analysis shows that some releases of radioactive material are to be anticipated during the cleanup of the 236Z rubble piles. The modeling results presented here are closely tied to the details of how the rubble removal is to be conducted. The results indicate that for the rubble removal, the radiological exposures from the planned activities are predicted to be well below the designated limits for air and soil exposures. The cleanup of the 236Z main process cell rubble is expected to release some alpha-emitting radionuclides. However, results based on 6 years of hourly climatological data, two representative cleanup periods, realistic mitigating actions, and a bounding source term indicate that concentrations at the fence line of the PFP facilities should remain well below 12 DAC-hours/week. The results presented in this report are a reevaluation of a subset of the results presented in PNNL-20173 Rev. 4.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

Characterization of oceanic post-cold frontal clouds and their model representation. Final report

Low-level clouds are ubiquitous over the oceans, and their impact on the Earth’ radiative budget is important. However, general circulation models (GCMs) that are used to represent our climate and its evolution still experience problems to represent their correct amount and radiative impact. In the extratropical latitudes (~30-60 N/S), cloud properties are strongly modulated by the occurrence of anti-cyclones (high pressure systems) and cyclones (low pressure systems). While deep clouds dominate in cyclones near the center and along the cold and warm fronts, low-level clouds populate the colder regions of the cyclones, and more specifically the region in the wake of the cold fronts, the post-cold frontal region (PCF). The GCMs mentioned above were found to underestimate the amount of these PCF clouds, and this caused errors in their representation of the amount of solar radiation at the surface of the southern hemisphere oceans, causing an excess in absorption and errors in long-term predictions. To better understand which processes are ill-represented in the GCMs to cause such issues, we used ground-based observations from the Eastern North Atlantic (ENA) ARM site and a high resolution regional model (called WRF) to examine the properties of PCF clouds. With the WRF model, we simulated the passage of a cold front at the ENA site using theoretically distinct representations of convection and the physics of the boundary layer. While these physical representations had little impact on the timing, structure and circulation of the cold front, we found a high sensitivity to how the large scale information was fed into the model. Errors rapidly developed if the incoming flow information was injected too far from the site, but 1000 km was found to be an optimal distance between the outer boundary and the ENA site for a realistic cold front passage. With this model, we then conducted a series of experiment where convection and boundary layer schemes were changed, and revealed that 1) the clouds were more sensitive to the convection than boundary layer schemes and 2) the interaction between the two has a large impact. Furthermore, changing the representation of the physics in the model had greater impacts on PCF clouds than changing the initial conditions. As large-scale models increase their spatial resolution, convection will eventually be resolved but it remains that their representation of the physics of the boundary layer will matter for the correct representation of shallow (low-level) clouds. Observations were used to find which large-scale information had a clear relationship with PCF cloud and precipitation properties, in view of helping with GCM parameterizations and evaluation. Both lower troposphere stability and surface forcing were found to be important for PCF clouds that experience more vigorous dynamics than their tropical or subtropical counterparts. For cloud base and top heights, a simple measure of the change in potential temperature between the surface and the 800 hPa was found to be a good predictor. This relationship was found to hold as well when using data from campaigns recently conducted in the southern ocean south of Tasmania. A recent GCM was found to succeed in representing similar relations. For cloud depth, water content, and different characteristics of precipitation both the temperature contrast between the surface and near-air and the near-surface wind speed had a strong relationship. To summarize, through observational constraints and regional model experiments, the project has provided guidance to evaluate GCMs and tools to improve their representation of low-level clouds in the extratropics. It has also highlighted differences in behavior between these clouds and those typically found in the subtropics, thus opening new avenues of research for shallow clouds in general.

54 ENVIRONMENTAL SCIENCES↗

WSF B696R Calcs

This calculation is applied to the accident analysis scenario of a limited combustibles fire breaching eight SWBs in B696R R1010. For a fire in a building with no breaches, there is only a ground release. The source term (ST) of the deflagration is determined by the Waste Storage Facilities Documented Safety Analysis (Ref. 1). The doses from the release are calculated by using MACCS2 (Ref. 2). This software take hourly meteorological data for a year as input. There are 8760 hours in a year. MACCS2 calculates a dose for each of the 8760 hours, taking into account the associated source term from Reference 1, the wind speed, the stability class (i.e., A through F), the directional sector of the wind (with associated distance to the site boundary). For each directional sector (i.e., 1 through 16) a MACCS2 run was performed. From the total collection of MACCS2 output files, Microsoft Excel is used to extract the dose that correspond to the meteorological conditions of each hour in the year. Note: although MACCS2 inputs a single year of meteorological data, five years are used (2010 through 2014) by performing multiple runs. This is discussed in Section 2.2. Conclusions: The final 95th percentile dose at the collocated worker used for accident analysis of a limited combustibles fire breaching eight SWBs in B696R R1010 is 18.4 rem.

99 GENERAL AND MISCELLANEOUS↗

General Analysis of Data Collected from DOE Lidar Buoy Deployments Off Virginia and New Jersey

Pacific Northwest National Laboratory (PNNL) operates two AXYS WindSentinel lidar buoys for the U.S. Department of Energy’s Wind Energy Technologies. The purpose of these buoys is to collect hub-height winds and supporting meteorological and oceanographic information to facilitate the development of offshore wind energy in the U.S. In general, each buoy is deployed for a year or more at a given location in order to capture at least a full annual cycle of weather conditions. The initial deployment for one buoy was off the coast of Virginia beginning in 2015, and the other buoy was first deployed off the coast of New Jersey beginning in 2016. Over the last two years, PNNL has had an opportunity to analyze the data collected during these first two deployments. This report describes a substantial analysis of data collected by the two lidar buoys operated off the coasts of Virginia and New Jersey. The centerpiece instrument for each buoy as deployed off Virginia and New Jersey is a lidar system, which is designed to measure the horizontal wind vector from approximately 40 m to 200 m above the sea surface with vertical resolution of 40 m. Since the initial deployments, the original lidars have been replaced with more powerful Leosphere 866 v2 systems. The analyses in this report will apply to the original Vindicator systems. In addition to the wind profiles from the lidars, the buoys collect near-surface measurements of wind speed and direction, air temperature, relative humidity, barometric pressure, and solar irradiance. Oceanographic variables measured include the two-dimensional wave spectrum, water temperature and conductivity, and ocean current vectors to a depth of 90 m. An assessment of overall data recovery and a basic analysis of the data collected was provided in a previous report This report substantially extends that analysis. The various sections describe the development and application of an inertial measurement unit (IMU) data recovery scheme for the New Jersey deployment; a climatological analysis of winds at hub height and at the surface together with thermodynamic variables measured at the surface for the full deployment periods; an analysis of oceanographic observations describe sea state; the development of a refinement for NOAA’s WaveWatch III model to allow its application to near-shore areas; a basic climatology of ocean currents observed from the buoys; an analysis of observed winds in the framework of Monin-Obukhov Similarity Theory; and the development and evaluation of techniques to extract turbulence intensity and turbulence kinetic energy from the lidars. The analyses contained in this report provide a great deal of new information about offshore conditions on the U.S. East Coast. In addition, the experience gained will inform both configurations and analysis of data from future deployments of these lidar buoy systems.

17 WIND ENERGY↗

Dial-A-Cluster User Manual

The Dial-A-Cluster (DAC) model allows interactive visualization of multivariate time series data. A multivariate time series dataset consists of an ensemble of data points, where each data point consists of a set of time series curves. The example of a DAC dataset used in this guide is a collection of 100 cities in the United States, where each city collects a year's worth of weather data, including daily temperature, humidity, and wind speed measurements.

97 MATHEMATICS AND COMPUTING↗

Vertical Axis Wind Turbine (VAWT) with Thermoplastic Composite Blades

Rising concerns about global climate change, planet pollution and increasing use of energy have accelerated wider utilization of renewable energy sources. A recent trend in energy system development is decentralization of power generation systems. The opportunity for individuals or organizations to generate electricity locally decreases losses and part of the electricity price caused by the long-distance power transmission. Vertical axis wind turbines (VAWTs) cannot compete with traditional horizontal axis wind turbines (HAWTs) on the basis of aerodynamic performance or maximum power output generated for a given footprint. However, their ability to perform at a wide range of wind speeds, indifference to wind direction, simplicity of fabrication, transportability and maintainability make them ideal candidates for decentralized installations in urban and residential areas. The project team including Steelhead Composites (SHC), Colorado State University (CSU), National Renewable Energy Laboratory (NREL) and Arkema Inc. designed and fabricated a VAWT rotor assembly with thermoplastic composite blades using novel infusion and fabrication techniques. This full-scale VAWT rotor assembly was designed for a rated power output of 0.5-1 kW, as estimated through analytical computational fluid dynamics (CFD) methods. Those CFD simulations were combined with structural finite element analysis (FEA) to optimize the shape and composite layup of the wind blades. Much of the emphasis of this program was to characterize the recyclable thermoplastic material and composite structural design, in order to take full advantage of the material properties of such composites. Additionally, this project examined the potential of thermoplastic resin systems to transform the way VAWT rotor assemblies are joined both in the factory in in the field, by utilizing thermally welded joints to minimize field failure. The infused composite blades manufactured during this program are an excellent example of these benefits made possible by the Arkema thermoplastic resin system. This prototype blade manufacturing also provided the groundwork to inform decisions for larger scale manufacturing techniques applicable to a commercialization strategy. There is specific commercial interest for small scale VAWT’s that are competitively priced, perform to expectations, and have environmentally conscious end-of-life characteristics. Economic analysis was also conducted to compare designs and material usage, providing an estimated levelized cost of energy (LCOE) for the VAWT. The next steps for commercialization would include testing of the rotor assembly to verify predicted performance, specification of the balance of plant components (generator, inverter, etc.), and identification of a manufacturing partner with capability to scale-up production. This program has showed the potential for a commercially viable product through detailed analysis, material characterization and prototype fabrication.

17 WIND ENERGY↗

Least-Cost Pathways for India's Electric Power Sector

The Government of India has a target of deploying 175 GW from renewable energy by 2022 and 40% of electricity capacity from renewable energy by 2030 and has indicated that ambitions for 2030 could be higher. Rapid changes in technology costs and performance could drive further deployment of wind and solar capacity beyond these policy targets. Increased deployment of variable renewable energy (VRE) raises new questions for power system planning regarding the optimal siting of generation capacity, trade-offs between generation and transmission infrastructure, and system flexibility needs. This study aims to evaluate least-cost pathways for India's electric power system over the period 2017-2047. Uniquely, this work considers an expanded planning horizon and range of scenarios not previously analyzed in national planning studies in India. The data collection and model design processes undertaken for this study provides a framework for recurring planning studies. This study finds anticipated changes in electricity demand and component costs can drive a significant shift in India's future electricity supply and how this system will be operated. In the Base scenario, the share of generation from VRE reaches 54% by 2047. Reducing the capital cost of wind has a larger impact on VRE penetration than reducing the capital cost of solar PV or battery storage. In the lowest wind cost scenario (40% capital cost decline by 2047 relative to the Base scenario), the penetration of VRE in the generation mix reaches 722%, exceeding the penetration levels achieved when the cost of battery storage or solar PV are reduced by an even greater 50%. In a future system with high penetrations of RE, capacity additions are driven by the coincidence of demand and RE generation rather than peak demand alone. This study finds the system could have surplus capacity during the peak demand months of July–September because this period corresponds to periods with high wind speeds and more wind generation available to meet peak demand. By contrast, new capacity is needed to meet demand during moderate demand months of October–November when output from wind plants falls more than 75% nationally compared to the previous two months. Finally, the success for gas for electricity production may depend on cost competitiveness rather than fuel availability. Increasing the amount of gas available for electricity production had no significant impact on the capacity or generation mix by 2047, as determined from a scenario that significantly increases fuel availability throughout the planning horizon. In fact, over 80% of new gas fuel available for the power sector remains unused. This suggests the high cost of gas plant operations relative to other technologies may constrain the expansion of gas generation in India more than fuel availability.

14 SOLAR ENERGY↗

Using the CAP88 Plume Model & Dose Assessment Code for the FTWC Project

The Environmental Protection & Compliance Division (EPC) uses the Clean Air Act Assessment Package – 1988 (CAP88) plume model and dose assessment code to evaluate measured emissions or projected emissions of airborne radionuclides from Los Alamos National Laboratory (LANL) facilities. This software package will use facility data (e.g., stack height and exit velocity), emissions parameters (chemical form and quantity), and environmental data (wind speed and direction) to predict downwind concentrations of radioactive material and subsequent dose to a member of the public at that location. The United States Environmental Protection Agency (EPA) has approved CAP88 for use in demonstrating compliance with the Radionuclide NESHAP2, that portion of the Clean Air Act addressing emissions of airborne radioactive material from Department of Energy facilities. EPC Division has two procedures which discuss the use of CAP88.

61 RADIATION PROTECTION AND DOSIMETRY↗

Geophysical and Planetary Acoustics on Balloons

Natural events and human activity often generate acoustic waves capable of traveling tens to tens of thousands of kilometers across the globe. Ground-based acoustic sensors are limited to dry land and often suffer from wind noise. In contrast, balloon borne acoustic sensors can cross oceans, polar ice caps, and other inhospitable areas, greatly expanding sensor coverage. Since they move with the mean wind speed, their background noise levels are exceptionally low. In the last six years, such sensors have recorded sounds from colliding ocean waves, surface and buried chemical explosions, thunder, wind/mountain interactions, wind turbines, aircraft, and possibly meteors and the aurora. These results have led to new insights on acoustic heating of the upper atmosphere, the detectability of underground explosions, and directional sound fields generated by ocean waves.

47 OTHER INSTRUMENTATION↗

Macro-physical Properties of Shallow Cumulus from Integrated ARM Observations (Final Report)

Fair-weather shallow cumuli (ShCu) play an important role in many climate-related processes. Irregular geometry of ShCu and their strong temporal and spatial variability make it challenging to observe ShCu holistically and to represent them correctly in climate models. To improve ShCu parameterizations, information on both vertically and horizontally resolved cloud properties is required. Commonly, the vertically resolved cloud properties are provided by zenith pointing lidar-radar observations with a very narrow field of view (FOV). Thus, these “pencil-beam” properties may not be representative of a larger surrounding area. Limited number of areal-averaged cloud properties, such as fractional sky cover (FSC), are offered typically by wide-FOV observations. The main goal of our project was to integrate advantages of the narrow-FOV (vertical structure of clouds) and wide-FOV (spatial arrangement of clouds) observations for an improved characterization of single-layer ShCu observed at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site for an 18-yr period (2000-2017). There are four major accomplishments of our project, First, an updated operational cloud classification for days with ShCu has been suggested and evaluated through a detailed comparison with the manually curated records. Our classification extends successfully the latest ARM cloud type Value Added Product (VAP) based on the Active Remote Sensing of Clouds (ARSCL) cloud product by incorporating both cloud fraction (CF) provided by narrow-FOV ceilometer data and FSC from wide-FOV images offered by a Total Sky Imager (TSI). Moreover, our classification allows one to identify impact of instrumentation changes at the SGP site, namely the transition to KAZRARSCL with the updated cloud radar, on the identification of periods with single-layer ShCu. Second, a new approach that resolves cloud area distributions for a given region (up to 4x4 km 2 ) has been suggested and cloud equivalent diameters (CEDs) have been estimated for the first time. These estimations have been performed over a wide range of cloud sizes (about 0.01–3.5 km) with high temporal resolution (30s) using wide-FOV TSI images and cloud base height (CBH) provided by complementary narrow-FOV lidar measurements. Our simple and computationally inexpensive approach offers a previously unavailable dataset for process studies in the convective boundary layer and evaluation of ShCu parameterizations in cloud-resolving models. Third, a long-term integrated record of ShCu macrophysical properties has been developed. The developed record represents the longest available compilation of events with ShCu and includes (i) a novel visualization of the spatial variability in cloud cover both along- and across-wind directions, (ii) updated estimates of narrow-FOV CF and wide-FOV FSC, (iii) updated narrow-FOV CBH, and (iv) complementary data, such as wind speed and direction from the 915-MHz Radar Wind Profiler (RWP) data. The developed record has been used successfully to assess conventional observational estimates of cloud cover and their sensitivity to the following two factors: (i) instrument-dependent cloud detection and data merging criteria and (ii) FOV configuration. Fourth, co-variability of the ShCu macrophysical properties and environmental parameters has been analyzed for a 3-yr period (2016-2018). Our initial analysis includes diurnal changes of FSCs obtained for clouds with small, moderate and large CEDs and several environmental parameters, such as lifted condensation level (LCL) and mixed layer height (zi). Preliminary results of our analysis suggest that the horizontal extent of ShCu is controlled substantially by the sign and magnitude of difference between these two parameters (zi-LCL): the CED tends to grow with increase of this difference (zi exceeds LCL). We have initiated relationships between the ShCu and key atmospheric parameters that control both the development and evolution of ShCu using our new data product, which combines effectively the advantages of narrow-FOV data offered by zenith pointing cloud radars and lidars and wide-FOV TSI images. While the latest instrumentation at the ARM sites may address these challenging relationships in the future, we believe that the historical ARM data at the SGP site has not yet been fully utilized. Overall, our data product can be used by researchers working on a wide range of climate-related projects. These projects may include (i) a comprehensive evaluation of outputs from the Large-Eddy Simulation (LES) and single-column models for their future improvement, (ii) the representativeness of “short-period” results obtained from the previous model and observational studies and (iii) the planning of future field campaigns with focus on improved understanding of the diurnal cycle of cumulus convection.

54 ENVIRONMENTAL SCIENCES↗

The Cost of Floating Offshore Wind Energy in California Between 2019 and 2032

California’s energy planning is centered around meeting the emissions reduction and renewable energy requirements of Senate Bill 350 by 2030. However, state power system planning is expected to eventually address California’s requirement to achieve 100% of total retail electricity sales from renewable energy and zero-carbon resources by 2045, as mandated by Senate Bill 100. To comply with these directives, California needs to investigate the further development of energy efficiency, storage, and a diverse range of renewable energy, zero-carbon emission, and transmission resources, including offshore wind. Wind resources off the coast of California have the potential to generate a significant portion of the state’s electric energy as it moves toward a zero-carbon economy and can help diversify its energy mix. Floating offshore wind technology, which is suitable for the deep waters along the California coast, is currently in a precommercial phase, with approximately 84 megawatts (MW) installed worldwide at the end of 2019. Globally there are over 7,000 MW in planning and permitting phases of development, with the first commercial-scale projects expected to be operational in 2024. This study provides site-specific cost and performance data for floating offshore wind to inform California’s long-term energy planning. The identification of new resources to meet California’s policy goals at least cost is part of the Integrated Resource Planning (IRP) process, which is coordinated by the California Public Utilities Commission (CPUC). In 2019–2020 IRP modeling, offshore wind was included for the first time as a candidate resource in some sensitivity cases (CPUC 2019). The data and information presented in this report can be used to update offshore wind inputs in future IRP cycles. The authors conducted a geospatial cost analysis over portions of the offshore wind resource area of California. The analyzed spatial domain includes sites with a mean wind speed of at least 7 meters per second and water depths between 40 meters (m) and 1,300 m. Costs and energy production vary across this analysis domain. We calculated these parameters on a grid layout with over 750 sites, with each site representing a 1,000-MW commercial offshore wind power plant. Levelized cost of energy (LCOE) was calculated at each site over the analysis domain. The resulting variation in LCOE across the analysis domain is illustrated through heat maps in this report. Five study areas were selected within the analysis domain where more detailed cost analysis was conducted and cost parameters, such as annual energy production, capital cost expenditures (CapEx), operational cost expenditures (OpEx), and net capacity factors are reported. These five study areas include Morro Bay, Diablo Canyon, Humboldt, Cape Mendocino and Del Norte.

17 WIND ENERGY↗

Refine your search to explore more results.