Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vibration testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Technology Transferred to the Kirby Company

NASA Lewis Research Center's Propulsion Systems Branch, evaluated the structural and vibration characteristics of the Kirby Model G-4 fan. Modes of vibration and resonance potential were evaluated in the Holography Test Lab at Lewis. As a result of the Lewis tests and rotor structural evaluation, Kirby engineers gained new insights into their existing design, enabling them to develop a more robust fan for use in their vacuum cleaners.

Source record↗

Fiber-Optic Continuous Liquid Sensor for Cryogenic Propellant Gauging

An innovative fiber-optic sensor has been developed for low-thrust-level settled mass gauging with measurement uncertainty <0.5 percent over cryogenic propellant tank fill levels from 2 to 98 percent. The proposed sensor uses a single optical fiber to measure liquid level and liquid distribution of cryogenic propellants. Every point of the sensing fiber is a point sensor that not only distinguishes liquid and vapor, but also measures temperature. This sensor is able to determine the physical location of each point sensor with 1-mm spatial resolution. Acting as a continuous array of numerous liquid/vapor point sensors, the truly distributed optical sensing fiber can be installed in a propellant tank in the same manner as silicon diode point sensor stripes using only a single feedthrough to connect to an optical signal interrogation unit outside the tank. Either water or liquid nitrogen levels can be measured within 1-mm spatial resolution up to a distance of 70 meters from the optical interrogation unit. This liquid-level sensing technique was also compared to the pressure gauge measurement technique in water and liquid nitrogen contained in a vertical copper pipe with a reasonable degree of accuracy. It has been demonstrated that the sensor can measure liquid levels in multiple containers containing water or liquid nitrogen with one signal interrogation unit. The liquid levels measured by the multiple fiber sensors were consistent with those virtually measured by a ruler. The sensing performance of various optical fibers has been measured, and has demonstrated that they can survive after immersion at cryogenic temperatures. The fiber strength in liquid nitrogen has also been measured. Multiple water level tests were also conducted under various actual and theoretical vibration conditions, and demonstrated that the signal-to-noise ratio under these vibration conditions, insofar as it affects measurement accuracy, is manageable and robust enough for a wide variety of spacecraft applications. A simple solution has been developed to absorb optical energy at the termination of the optical sensor, thereby avoiding any feedback to the optical interrogation unit

Xu. Wei↗

NASA Tech Briefs, January 2003

Topics covered include: Optoelectronic Tool Adds Scale Marks to Photographic Images; Compact Interconnection Networks Based on Quantum Dots; Laterally Coupled Quantum-Dot Distributed-Feedback Lasers; Bit-Serial Adder Based on Quantum Dots; Stabilized Fiber-Optic Distribution of Reference Frequency; Delay/Doppler-Mapping GPS-Reflection Remote-Sensing System; Ladar System Identifies Obstacles Partly Hidden by Grass; Survivable Failure Data Recorders for Spacecraft; Fiber-Optic Ammonia Sensors; Silicon Membrane Mirrors with Electrostatic Shape Actuators; Nanoscale Hot-Wire Probes for Boundary-Layer Flows; Theodolite with CCD Camera for Safe Measurement of Laser-Beam Pointing; Efficient Coupling of Lasers to Telescopes with Obscuration; Aligning Three Off-Axis Mirrors with Help of a DOE; Calibrating Laser Gas Measurements by Use of Natural CO2; Laser Ranging Simulation Program; Micro-Ball-Lens Optical Switch Driven by SMA Actuator; Evaluation of Charge Storage and Decay in Spacecraft Insulators; Alkaline Capacitors Based on Nitride Nanoparticles; Low-EC-Content Electrolytes for Low-Temperature Li-Ion Cells; Software for a GPS-Reflection Remote-Sensing System; Software for Building Models of 3D Objects via the Internet; "Virtual Cockpit Window" for a Windowless Aerospacecraft; CLARAty Functional-Layer Software; Java Library for Input and Output of Image Data and Metadata; Software for Estimating Costs of Testing Rocket Engines; Energy-Absorbing, Lightweight Wheels; Viscoelastic Vibration Dampers for Turbomachine Blades; Soft Landing of Spacecraft on Energy-Absorbing Self-Deployable Cushions; Pneumatically Actuated Miniature Peristaltic Vacuum Pumps; Miniature Gas-Turbine Power Generator; Pressure-Sensor Assembly Technique; Wafer-Level Membrane-Transfer Process for Fabricating MEMS; A Reactive-Ion Etch for Patterning Piezoelectric Thin Film; Wavelet-Based Real-Time Diagnosis of Complex Systems; Quantum Search in Hilbert Space; Analytic Method for Computing Instrument Pointing Jitter; and Semiselective Optoelectronic Sensors for Monitoring Microbes.

Source record↗

Metrology of Large Parts

As discussed in the first chapter of this book, there are many different methods to measure a part using optical technology. Chapter 2 discussed the use of machine vision to measure macroscopic features such as length and position, which was extended to the use of interferometry as a linear measurement tool in chapter 3, and laser or other trackers to find the relation of key points on large parts in chapter 4. This chapter looks at measuring large parts to optical tolerances in the sub-micron range using interferometry, ranging, and optical tools discussed in the previous chapters. The purpose of this chapter is not to discuss specific metrology tools (such as interferometers or gauges), but to describe a systems engineering approach to testing large parts. Issues such as material warpage and temperature drifts that may be insignificant when measuring a part to micron levels under a microscope, as will be discussed in later chapters, can prove to be very important when making the same measurement over a larger part. In this chapter, we will define a set of guiding principles for successfully overcoming these challenges and illustrate the application of these principles with real world examples. While these examples are drawn from specific large optical testing applications, they inform the problems associated with testing any large part to optical tolerances. Manufacturing today relies on micrometer level part performance. Fields such as energy and transportation are demanding higher tolerances to provide increased efficiencies and fuel savings. By looking at how the optics industry approaches sub-micrometer metrology, one can gain a better understanding of the metrology challenges for any larger part specified to micrometer tolerances. Testing large parts, whether optical components or precision structures, to optical tolerances is just like testing small parts, only harder. Identical with what one does for small parts, a metrologist tests large parts and optics in particular to quantify their mechanical properties (such as dimensions, mass, etc); their optical prescription or design (i.e. radius of curvature, conic constant, vertex location, size); and their full part shape. And, just as with small parts, a metrologist accomplishes these tests using distance measuring instruments such as tape measures, inside micrometers, coordinate measuring machines, distance measuring interferometers; angle measuring instruments such as theodolites, autocollimators; and surface measuring instruments including interferometers, stylus profilers, interference microscopes, photogrammetric cameras, or other tools. However, while the methodology may be similar, it is more difficult to test a large object for the simple reason that most metrologists do not have the necessary intuition. The skills used to test small parts or optics in a laboratory do not extrapolate to testing large parts in an industrial setting any more than a backyard gardener might successfully operate a farm. But first, what is a large part? A simple definition might be the part's size or diameter. For optics and diffuse surface parts alike, the driving constraint is ability to illuminate the part's surface. For reflective convex mirrors, large is typically anything greater than 1 meter. But, for refractive optics, flats or convex mirrors, large is typically greater than 0.5 meter. While a size definition is simple, it may be less than universal. A more nuanced definition might be that a large part is any component which cannot be easily tested in a standard laboratory environment, on a standard vibration isolated table using standard laboratory infrastructure. A micro-switch or a precision lens might be easily measured to nanometer levels under a microscope in a lab, but a power turbine spline or a larger telescope mirror will not fit under that microscope and may not even fit on the table.

Stahl, H. Philip↗

Ocean Color Instrument Integration and Testing

This paper describes the plans, flows, key facilities, components and equipment necessary to fully integrate, functionally test, qualify and calibrate the Ocean Color Instrument (OCI) on the Plankton, Aerosols, Clouds, and oceans Ecosystem (PACE) observatory. PACE is currently in the design phase of mission development. It is scheduled to launch in 2022, extending and improving NASA's twenty-year record of satellite observations of global ocean biology, aerosols and clouds. PACE will advance the assessment of ocean health by measuring the distribution of phytoplankton, which are small plants and algae that sustain the marine food web. It will also continue systematic records of key atmospheric variables associated with air quality and the Earth's climate. PACE's primary sensor, the OCI, is a highly advanced optical spectrometer that will be used to measure properties of light over portions of the electromagnetic spectrum. It will enable continuous measurement of light at finer wavelength resolution than previous NASA satellite sensors, extending key system ocean color data records for climate studies. The color of the ocean is determined by the interaction of sunlight with substances or particles present in seawater such as chlorophyll. By monitoring global phytoplankton distribution and abundance with unprecedented detail, the OCI will contribute to a better understanding of the complex systems that drive ocean ecology and it's impacts on global fisheries. This paper will focus on the Integration and Test (I&T) activities for OCI while it is at the NASA Goddard Space Flight Center. The OCI integration consists of assembly and alignment of the rotating telescope, electronics box integration, fixed deck assembly integration, thermal systems integration and the final assembly and testing. This I&T phase will be followed by the OCI calibration and characterization, environmental tests which include electromagnetic interference (EMI)/electromagnetic compatibility (EMC), vibration with sine sweep, acoustics, shock, thermal balance, thermal vacuum, mass properties and center of gravity. This paper will briefly discuss OCI shipment and delivery to the spacecraft vendor for observatory level I&T as well as some launch preparation activities.

Petro, Susanna↗

Orion Capsule Parachute Assembly System (CPAS) Main and Drogue Canopy Instrumentation

Reefing systems are often used in parachute systems to control loading and inflation of the canopies. These systems typically use pyrotechnic cutters to sever lines to progress through the staging. Existing cutters have been used for more than 50 years and have been proven adequate through countless demands. These cutters must survive and operate through severe environments that include a large snatch load at deployment and random vibration through the stage. In lieu of extensive drop test campaigns, future cutters will need to be ground tested to environments which are representative of the flight environments. The Capsule Parachute Assembly System (CPAS) developed sensors that capture accelerations and rates in three axes at approximately 1500 Hertz (Hz) during parachute deployment and operation. These sensors have mass properties, size, and an attachment method similar to existing reefing line cutter assemblies, maximizing the usability of the data. Various risk reduction steps were taken to minimize any negative effects to the qualification parachute system and to increase the likelihood of collecting usable data. 24 sensors were flown on 12 qualification parachutes, successfully collecting sufficient data to characterize the deployment and operational environment of the reefing line cutters.

Daum, Jared S.↗

Transformational Solar Array Option I Final Report

This report summarizes the work performed under NASA contract NNC16CA19C from May 2, 2017 through April 2, 2018. This work is directed toward meeting the goals of the associated NASA NRA and, of course, the requirements of the contract. In brief, the goals are: (1) Over 47% beginning of life cell efficiency at 5 AU and -125 °C (2) Over 32% end of life efficiency at the blanket level at 50 W m-2, -125 °C and 4E15 1 MeV e cm-2 (3) Over 8 W kg-1 at EOL for the entire array including structure, deployment, and pointing mechanisms using beginning of life performance. (4) A stowed packaging density of greater than 66 kW m-3 (5) An ability to survive launch and numerous deploy retract cycles without degradation (6) An output higher than 300 V (7) An ability to operate in a plasma generated by xenon thrusters, typically 1E8 cm-3 ions with an average energy of 2 eV (8) A design compatible with electrostatic and magnetic cleanliness (9) Record breaking inverted metamorphic (IMM) 6 junction solar cells (10) IMM solar cells that have no anomalous flat spot behavior at low irradiance and low temperature (11) A mock-up production line for the low-cost manufacture of spacecraft blanket arrays. The Option I phase of the project continued efforts, started in the base-phase, to eliminate or reduce to very low levels the flat spots that reduce power to an unacceptable value in a significant percentage of cells and to reduce outgassing contamination of the concentrators to acceptable levels. Option I adds tasks to increase the efficiency of IMM cells from those produced in the Base Phase, to eliminate delamination of the coatings that were present in previous versions of the concentrator mirrors, to evaluate pressure sensitive adhesive as a method of fixing solar cell assemblies to blankets, to design a magnetically clean brake for ROSA, to test the robustness of a sample blanket in deploy and retract, to test for the adequate performance of a blanket in vibration and thermal environments, and to define the capital equipment needed to optimize production of the Transformational Array. 5 Work for this Final Report showed that the greatest likely improvement in the solar cells would be by emphasizing the effort for the IMM4 solar cells and stopping work on other IMM cells. For this phase, the solar cell work was primarily on the IMM4 cells with little work on IMM5 and none on IMM6 cells.

Gaddy, Edward↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S. Faragalla↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S Faragalla↗

Piezoelectric pushers for active vibration control of rotating machinery

The active control of rotordynamic vibrations and stability by magnetic bearings and electromagnetic shakers was discussed extensively in the literature. These devices, though effective, are usually large in volume and add significant weight to the stator. The use of piezoelectric pushers may provide similar degrees of effectiveness in light, compact packages. Analyses are contained which extend quadratic regulator, pole placement and derivative feedback control methods to the prescribed displacement character of piezoelectric pushers. The structural stiffness of the pusher is also included in the theory. Tests are currently being conducted at NASA Lewis Research Center with piezoelectric pusher-based active vibration control. Results performed on the NASA test rig as preliminary verification of the related theory are presented.

Palazzolo, A. B.↗

Flow Sensor Test Article (F-STAr) - Water Testing and Commissioning Report for FY2024

Argonne National Laboratory’s Mechanism Engineering Test Loop (METL) facility is developing new experimental testing capabilities with the Flow Sensor Test Article (F-STAr). F-STAr’s mission is to provide high flowrate, sodium submersible testing capabilities to support the development of sodium cooled nuclear fission reactors. Figure 1 shows a model of F-STAr (left) and a photo of the partially assembled test article (right) with several of the main components labeled. The system currently includes a large pump with desired flowrates of up to 100 GPM; an immersion heater with a maximum power of 5 kW; an immersion cooler with an estimated maximum cooling power of 2 kW; and an experimental test section to support sub-test articles. Initially, F-STAr will be setup for testing flow sensors, specifically Eddy Current Flow Sensors (ECFS). However, the system can be reconfigured to support a wide range of testing needs. For example, F-STAr could be setup to complete testing of hydraulic components, heat exchangers, hydrodynamic bearings, seals, and more. This report will provide an update on the development of F-STAr with a focus on the water testing and commissioning activities during Fiscal Year 2024 (FY24). First, the report will focus on describing the pump development. Specifically, updates will be provided on troubleshooting the pump’s excessive vibrational issues. In addition to updates on the pump, pressure-flowrate performance testing in water will be described. Furthermore, updates will be provided on a pump shaft bushing development as well as rigging procedures. Future work and paths forward for F-STAr will be described. Finally, a short summary on the ECFS development will be described at the end of the report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NASA's Robotic Lunar Lander Development Project

Since early 2005, NASA's Robotic Lunar Lander Development (RLLD) office at NASA MSFC, in partnership with the Applied Physics Laboratory (APL), has developed mission concepts and preformed risk-reduction activities to address planetary science and exploration objectives uniquely met with landed missions. The RLLD team developed several concepts for lunar human-exploration precursor missions to demonstrate precision landing and in-situ resource utilization, a multi-node lunar geophysical network mission, either as a stand-alone mission, or as part of the International Lunar Network (ILN), a Lunar Polar Volatiles Explorer and a Mercury lander mission for the Planetary Science decadal survey, and an asteroid rendezvous and landing mission for the Exploration Precursor Robotics Mission (xPRM) office. The RLLD team has conducted an extensive number of risk-reduction activities in areas common to all lander concepts, including thruster testing, propulsion thermal control demonstration, composite deck design and fabrication, and landing leg stability and vibration. In parallel, the team has developed two robotic lander testbeds providing closed-loop, autonomous hover and descent activities for integration and testing of flight-like components and algorithms. A compressed-air test article had its first flight in September 2009 and completed over 150 successful flights. This small test article (107 kg dry/146 kg wet) uses a central throttleable thruster to offset gravity, plus 3 descent thrusters (~37lbf ea) and 6 attitude-control thrusters (~12lbf ea) to emulate the flight system with pulsed operation over approximately 10s of flight time. The test article uses carbon composite honeycomb decks, custom avionics (COTS components assembled in-house), and custom flight and ground software. A larger (206 kg dry/322 kg wet), hydrogen peroxide-propelled vehicle began flight tests in spring 2011 and fly over 30 successful flights to a maximum altitude of 30m. The monoprop testbed also uses a central gravity-canceling thruster and 3 descent thrusters, but has 12 attitude-control thrusters and a maximum flight time of over a minute. The testbed uses aluminum ortho-grid decks, an LN200-1 IMU, Roke Manor Radar Altimeter, Illunis optical cameras, Novatel Pro-Pak GPS truth data system, Pressure transducers & thermocouples for housekeeping, "In-Control" ground system software, and the core Flight Executive (cFE) modular software environment. The peroxide lander testbed is able to accept other sensors and algorithms for testing, both from within NASA and from other customers. Through these activities, the RLLD team has significantly reduced technical risks for all small and medium class robotic landers for the Moon and other airless planetary bodies.

Cohen, Barbara A.↗

Shuttle payload vibroacoustic test plan evaluation. Free flyer payload applications and sortie payload parametric variations

A preliminary assessment of vibroacoustic test plan optimization for free flyer STS payloads is presented and the effects on alternate test plans for Spacelab sortie payloads number of missions are also examined. The component vibration failure probability and the number of components in the housekeeping subassemblies are provided. Decision models are used to evaluate the cost effectiveness of seven alternate test plans using protoflight hardware.

Stahle, C. V.↗

An Investigation into the Potential Application of Wavelets to Modal Testing and Analysis

The analysis of transient data of the type found in vibrating mechanical systems has been greatly improved through the use of modern techniques such as Fourier analysis. This is especially true when considered in conjunction with the development of the so-called Fast Fourier Transform algorithm by Cooley and the tremendous strides in computational power of the last several decades. The usefulness of the discrete Fourier Transform is its ability to transform sampled data from the "time-domain" to the "frequency domain," thereby allowing the analyst to decompose a signal into its frequency content. More recent developments have led to the wavelet transform. The strength of wavelet analysis is its ability to maintain both time and frequency information, thus making it an attractive candidate for the analysis of non-stationary signals. This report is an overview of wavelet theory and the potential use of the wavelet transform as an alternative to Fourier analysis in modal identification.

A. Fort Gwinn, Jr.↗

Explainable AI (XAI)-driven vibration sensing scheme for surface quality monitoring in a smart surface grinding process

Local Interpretable and Model-agnostic Explanation (LIME), an explainable artificial intelligence (XAI) approach is adapted to identify the globally important time-frequency bands for predicting average surface roughness (Ra) in a smart grinding process. The smart grinding setup consisted of a Supertech CNC precision surface grinding machine, instrumented with a Dytran piezoelectric accelerometer attached to the tailstock quill along the tangential direction (Y-axis). For every grinding pass, vibration signatures were captured, and the ground truth surface roughness values were recorded using a Mahr Marsurf M300C portable surface roughness profilometer. The roughness values ranged from 0.06 to 0.14 microns over the complete set of experiments. Time-frequency domain spectrogram frames were extracted for each of the vibration signals collected during the grinding process. Convolutional Neural Networks (CNNs) were modeled to predict the surface roughness based on these spectrogram frames and their image augmentations. The best CNN model was able to predict the roughness values with an overall R2-score of 0.95, training R2-score of 0.99, and testing R2-score of 0.81 with only 80 sets of vibration signals corresponding to 4 experiments with 20 trials each. Although the data size is not large enough to guarantee such performance metrics in real-world scenarios, one can extract statistically consistent explanations underlying the relationships these complex deep learning models capture. Further, the LIME methodology was implemented on the developed surface roughness CNN model to identify the important time-frequency bands (i.e., the superpixels of a spectrogram) influencing the predictions. Based on the identified important regions on the spectrogram frames, the corresponding frequency characteristics were determined that influence the surface roughness predictions. The important frequency range based on LIME results was approximately 11.7 to 19.1 kHz. The power of XAI was demonstrated by cutting down the sampling rate from 160 kHz to 30, 20, 10, and 5 kHz based on the important frequency range and considering Nyquist criteria. Separate CNN models were developed for these ranges by only extracting time-frequency contents below their corresponding Nyquist cut-offs. A proper data acquisition strategy is proposed by comparing the model performances to argue the selection of a sufficient sampling rate to capture the grinding process successfully and robustly.

42 ENGINEERING↗

Reprint of: Explainable AI (XAI)-driven vibration sensing scheme for surface quality monitoring in a smart surface grinding process

Local Interpretable and Model-agnostic Explanation (LIME), an explainable artificial intelligence (XAI) approach is adapted to identify the globally important time-frequency bands for predicting average surface roughness (Ra) in a smart grinding process. The smart grinding setup consisted of a Supertech CNC precision surface grinding machine, instrumented with a Dytran piezoelectric accelerometer attached to the tailstock quill along the tangential direction (Y-axis). For every grinding pass, vibration signatures were captured, and the ground truth surface roughness values were recorded using a Mahr Marsurf M300C portable surface roughness profilometer. The roughness values ranged from 0.06 to 0.14 microns over the complete set of experiments. Time-frequency domain spectrogram frames were extracted for each of the vibration signals collected during the grinding process. Convolutional Neural Networks (CNNs) were modeled to predict the surface roughness based on these spectrogram frames and their image augmentations. The best CNN model was able to predict the roughness values with an overall R2-score of 0.95, training R2-score of 0.99, and testing R2-score of 0.81 with only 80 sets of vibration signals corresponding to 4 experiments with 20 trials each. Although the data size is not large enough to guarantee such performance metrics in real-world scenarios, one can extract statistically consistent explanations underlying the relationships these complex deep learning models capture. Further, the LIME methodology was implemented on the developed surface roughness CNN model to identify the important time-frequency bands (i.e., the superpixels of a spectrogram) influencing the predictions. Based on the identified important regions on the spectrogram frames, the corresponding frequency characteristics were determined that influence the surface roughness predictions. The important frequency range based on LIME results was approximately 11.7 to 19.1 kHz. The power of XAI was demonstrated by cutting down the sampling rate from 160 kHz to 30, 20, 10, and 5 kHz based on the important frequency range and considering Nyquist criteria. Separate CNN models were developed for these ranges by only extracting time-frequency contents below their corresponding Nyquist cut-offs. A proper data acquisition strategy is proposed by comparing the model performances to argue the selection of a sufficient sampling rate to capture the grinding process successfully and robustly.

47 OTHER INSTRUMENTATION↗

Feed-forward control of gear mesh vibration using piezoelectric actuators

This paper presents a novel means for suppressing gear mesh-related vibrations. The key components in this approach are piezoelectric actuators and a high-frequency, analog feed-forward controller. Test results are presented and show up to a 70-percent reduction in gear mesh acceleration and vibration control up to 4500 Hz. The principle of the approach is explained by an analysis of a harmonically excited, general linear vibratory system.

Montague, Gerald T.↗

Monodomain Liquid‐Crystal Elastomer Lattices for Broad Strain‐Rate Mechanical Damping

Designing structures that effectively dissipate energy across a broad range of mechanical loading rates, including those from compression, shock, and vibration, poses a significant engineering challenge. In this study, liquid‐crystal elastomers (LCEs), which possess anisotropic properties due to the alignment of their polymer backbone, are explored. As a result, LCEs exhibit a soft elastic response under mechanical loading, making them ideal for energy dissipation. Advances in additive manufacturing (AM) enable simple fabrication of foamlike dissipative structures with complex lattice geometries. Herein, direct ink write 3D printing, an extrusion AM method, is used to fabricate aligned, monodomain LCE lattice structures for broad strain‐rate mechanical damping. In this work, it is shown that these structures can dissipate strain energy in quasi‐static environments, comparable to traditional elastomeric lattices, and provide improved damping under high strain‐rate drop testing due to LCE soft elasticity. Additionally, under dynamic mechanical vibration, monodomain LCE lattices enhance damping at structural natural frequencies and provide high‐frequency attenuation. Finally, in these findings, a promising method is presented for fabricating mechanical damping devices that effectively dissipate energy across a broad range of loading rates.

3D printings↗

Refine your search to explore more results.