Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vessel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Quantifying Platelet Margination in Diabetic Blood Flow

According to this article, patients with type 2 diabetes mellitus (T2DM) develop thrombotic abnormalities strongly associated with cardiovascular diseases. In addition to the changes of numerous coagulation factors such as elevated levels of thrombin and fibrinogen, the abnormal rheological effects of red blood cells (RBCs) and platelets flowing in blood are crucial in platelet adhesion and thrombus formation in T2DM. An important process contributing to the latter is the platelet margination. We employ the dissipative particle dynamics method to seamlessly model cells, plasma, and vessel walls. We perform a systematic study on RBC and platelet transport in cylindrical vessels by considering different cell shapes, sizes, and RBC deformabilities in healthy and T2DM blood, as well as variable flowrates and hematocrit. In particular, we use cellular-level RBC and platelet models with parameters derived from patient-specific data and present a sensitivity study. We find T2DM RBCs, which are less deformable compared to normal RBCs, lower the transport of platelets toward the vessel walls, whereas platelets with higher mean volume (often observed in T2DM) lead to enhanced margination. Furthermore, increasing the flowrate or hematocrit enhances platelet margination. We also investigated the effect of platelet shape and observed a nonmonotonic variation with the highest near-wall concentration corresponding to platelets with a moderate aspect ratio of 0.38. We examine the role of white blood cells (WBCs), whose count is increased notably in T2DM patients. We find that WBC rolling or WBC adhesion tends to decrease platelet margination due to hydrodynamic effects. To the best of our knowledge, such simulations of blood including all blood cells have not been performed before, and our quantitative findings can help separate the effects of hydrodynamic interactions from adhesive interactions and potentially shed light on the associated pathological processes in T2DM such as increased inflammatory response, platelet activation and adhesion, and ultimately thrombus formation.

Biophysics↗

Effect of cylindrical confinement on the determination of laminar flame speeds using outwardly propagating flames

The effect of nonspherical (i.e. cylindrical) bomb geometry on the evolution of outwardly propagating flames and the determination of laminar flame speeds using the conventional constant-pressure technique is investigated experimentally and theoretically. The cylindrical chamber boundary modifies the propagation rate through the interaction of the wall with the flow induced by thermal expansion across the flame (even with constant pressure), which leads to significant distortion of the flame surface for large flame radii. These departures from the unconfined case, especially the resulting nonzero burned gas velocities, can lead to significant errors in flame speeds calculated using the conventional assumptions, especially for large flame radii. For example, at a flame radius of 0.5 times the wall radius, the flame speed calculated neglecting confinement effects can be low by {proportional_to}15% (even with constant pressure). A methodology to estimate the effect of nonzero burned gas velocities on the measured flame speed in cylindrical chambers is presented. Modeling and experiments indicate that the effect of confinement can be neglected for flame radii less than 0.3 times the wall radius while still achieving acceptable accuracy (within 3%). The methodology is applied to correct the flame speed for nonzero burned gas speeds, in order to extend the range of flame radii useful for flame speed measurements. Under the proposed scaling, the burned gas speed can be well approximated as a function of only flame radius for a given chamber geometry - i.e. the correction function need only be determined once for an apparatus and then it can be used for any mixture. Results indicate that the flow correction can be used to extract flame speeds for flame radii up to 0.5 times the wall radius with somewhat larger, yet still acceptable uncertainties for the cases studied. Flow-corrected burning velocities are measured for hydrogen and syngas mixtures at atmospheric and elevated pressures. Flow-corrected flame speeds in the small cylindrical chamber used here agree well with previously reported flame speeds from large spherical chambers. Previous papers presenting burning velocities from cylindrical chambers report performing data analysis on flame radii less than 0.5 or 0.6 times the wall radius, where the flame speed calculated neglecting confinement effects may be low by {proportional_to}15 or 20%, respectively. For cylindrical chambers, data analysis should be restricted to flame radii less than 0.3 times the wall radius or a flow correction should be employed to account for the burned gas motions. With regard to the design of future vessels, larger vessels that minimize the flow aberrations for the same flame radius are preferred. Larger vessels maximize the relatively unaffected region of data allowing for a more straightforward approach to interpret the experimental data. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 1 – Steady state modeling and speed ratio selection

Helium cryogenic systems which can provide cooling below the normal boiling point of helium (approximately 4.2 K) are often required by superconducting radio-frequency niobium resonators utilized in modern high-energy particle accelerators. Achieving temperatures below 4.2 K generally involves operating a cryogenic vessel with liquid helium under sub-atmospheric conditions, thereby lowering the saturation pressure and corresponding saturation temperature. Over the last several decades, multi-stage cryogenic centrifugal compressor trains (CC’s) have been operated efficiently and reliably within large-scale cryogenic systems to continuously evacuate helium vapor generated by a device within the vessel, maintaining sub-atmospheric conditions in the vessel while pressurizing the return vapor to above atmospheric conditions. Traditionally, these CC systems have been operated using empirically derived control philosophies and insight gathered from previous operational experience. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have been aimed at the development of a theoretical basis to characterize the operation of multi-stage cryogenic centrifugal compressor train and utilizing predictive model results to generate control parameters. The objective of this research was identifying operational points which adequately balance cryogenic system efficiency, stability, and overall ease of operation. Furthermore, this manuscript provides an overview of the predictive model development, characterization of the FRIB cryogenic centrifugal compressors and implementation of the predicted performance results during steady-state system operation.

Compressor train control↗

Design update of the ITER upper wide angle viewing system

One of the diagnostic systems being provided by the US is the Upper Wide Angle Viewing System (UWAVS) which provides real-time, simultaneous visible and infrared (IR) images of the ITER divertor regions via optical systems located in five upper ports. UWAVS is designed in three main sections: in-vessel, interspace and port cell assemblies. Each assembly utilizes multiple steering and relay mirrors to direct the in-vessel light out of the tokamak to the port cell camera sensors. The primary design challenge of the in-vessel assembly is maximizing performance of the overall system while surviving the severe electromagnetic and nuclear ITER environment. A first mirror material study was conducted and determined that single crystal molybdenum was the best choice for the first two mirrors in the optical train. A fail open, bellows actuated shutter with cross pivot flexure design was determined to be the most reliable mechanism to protect the first mirror. A geometrically representative glow discharge mirror cleaning system is being created and will be tested to maximize cleaning effectiveness while minimizing optical degradation of the molybdenum mirrors adjacent to the plasma. The shutter and first mirror assemblies were packaged and designed for replacement via remote handling methods to minimize radiation waste and cost associated with eventual component replacement. The preliminary optical and structural design provides a robust and reliable system while maximizing the field of view. The R&D efforts, the technical challenges and issues, and the design and analysis results are introduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tritium permeability measurement in hydrogen-tritium system

Fusion power promises to provide electricity generation with outstanding safety and environmental performance. Safety plays a crucial role in fusion material selection since tritium behavior in materials determines two key safety evaluation source terms: in-vessel inventory source term and ex-vessel release term, which are used in reactor safety assessments for licensing fusion facilities. Tritium permeation through materials at elevated temperature during long pulse operation expected in a burning plasma environment will become a major safety issue and development of tritium permeation barrier materials is required to minimize ex-vessel release to the environment [1]. Extensive work on hydrogen and deuterium behavior in fusion materials has been conducted, but very little database is available for tritium, the radioactive fuel for future reactors, due to the cost and difficulty associated with handling tritium [2]. A majority of the experiments were carried out at high hydrogen/deuterium partial pressure (> 100 Pa), but the expected tritium partial pressure in the blanket system is at low tritium partial pressure (< 100 Pa), where the tritium behavior deviates from diffusion-limited to surface-limited permeation. At these pressures the behavior of tritium is suspected to deviate from diffusion-limited to surface-limited permeation or isotope-limited [3]. The use of tritium enables us to investigate hydrogen isotope behavior in low partial pressure range with beta radiation detection. The physics of two-component hydrogen (H+T) permeation through metal in the surface-limited regime and through liquid breeding material are still too poorly understood to confidently design environmentally benign and safe fusion systems. In this paper, we discuss development of tritium permeation system for low tritium partial pressure [4], and discuss the results from two-component hydrogen (H+T) permeation in 20 mm disc samples of pure alpha-iron at H2 partial pressure of 100 Pa, wide T2 partial pressure range from 10-12 to 10 Pa, and sample temperature up to 600 °C to uncover the basic scientific understanding of tritium permeation behavior at realistic blanket conditions for DEMO. [1] FESAC report on “Opportunities for Fusion Materials Science and Technology Research Now and During the ITER Era” (2012) DOE/SC-0149 [2] R.A. Causey, R.A. Karnesky, and C. San Marchi, “4.16 Tritium Barriers and Tritium Diffusion in Fusion Reactors”, Comprehensive Nuclear Materials (2012) Chapter 4.16. [3] P. Humrickhouse “Permeation of Tritium and Hydrogen in the Diffusion-Limited and Surface–Limited Regimes”, submitted to Journal of Nuclear Materials. [4] R.J. Pawelko, M. Shimada, K. Katayama, S. Fukada, P.W. Humrickhouse, and T. Terai, “Low tritium partial pressure permeation system for mass transport measurement in lead lithium eutectic”, Fusion Engineering and Design 102 (2016) 8

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exact solutions of burst pressure for thick-walled cylinders in power-law strain hardening steels

Exact solutions of burst pressure for defect-free, thick-walled cylindrical pressure vessels with capped ends are developed using the flow theory of plasticity in terms of the Tresca, von Mises, and Zhu-Leis yield criteria. The material is assumed to obey a power-law strain hardening rule, and the finite strain theory is adopted to describe large plastic deformation. On this basis, internal pressure is obtained as a complex polynomial function of effective strains on the inside and outside surfaces of the pressure vessel with the use of the Bernoulli numbers. At burst failure, the effective strains and stresses on the inside and outside surfaces are first determined, and then three flow solutions of burst pressure are obtained as a power series function of the diameter ratio (D o /D i ), strain hardening exponent (n), and ultimate tensile strength (UTS). The power series solution is confirmed to agree well with the exact flow solution of burst pressure in a closed-form for each yield criterion, and the results show that the von Mises flow solution is an upper bound prediction, the Tresca flow solution is a lower bound prediction, and the Zhu-Leis flow solution is an intermediate prediction of burst pressure. In conclusion, two sets of full-scale burst test data are then utilized to evaluate and validate the proposed flow solutions of burst pressure for both thin-walled pipes and thick-walled cylindrical pressure vessels.

36 MATERIALS SCIENCE↗

Total Microvessel Perimeter Per Tumor Area Is a Predictor of Radiosensitivity in Early-Stage Glottic Carcinoma

Purpose: To confirm that total number of microvessels per tumor area (TN/TA) and total microvessel perimeter per tumor area (TP/TA) are predictors for radiosensitivity in early-stage glottic carcinoma. Methods and Materials: One hundred twenty consecutive patients with T1-2N0M0 glottic cancer who were treated with radical radiotherapy in three different hospitals in Japan were included in this study. Biopsy specimens from patients were immunostained with anti-CD31 antibody. The TN/TA and TP/TA of each sample were analyzed using a computer-assisted image analysis system. Patients were stratified into high and low groups according to the cut-off values derived from receiver operating characteristic curve analysis. Progression-free survival rates of the different groups were compared. The relationship of microvessel perimeter to vessel maturation was also discussed. Results: Survival analysis showed higher TP/TA to be associated significantly with longer progression-free survival, as compared with the lower-level group (p = 0.031). In multivariate analysis, both TP/TA (p = 0.037) and T stage (p < 0.001) proved to be independent predictive factors. Microvessel perimeter correlated closely with vessel maturity, which suggests that a tumor with high TP/TA contains more functional vessels and as a result contains more oxygenated and radiosensitive cells. Conclusion: Assessment of TP/TA in biopsy specimens, using a computer-assisted analysis system, can predict the radiosensitivity of early-stage glottic carcinoma. High TP/TA may be a better indication for radiotherapy than for partial laryngectomy or laser excision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vasculatures in Tumors Growing From Preirradiated Tissues: Formed by Vasculogenesis and Resistant to Radiation and Antiangiogenic Therapy

Purpose: To investigate vasculatures and microenvironment in tumors growing from preirradiated tissues (pre-IR tumors) and study the vascular responses of pre-IR tumors to radiation and antiangiogenic therapy. Methods and Materials: Transgenic adenocarcinoma of the mouse prostate C1 tumors were implanted into unirradiated or preirradiated tissues and examined for vascularity, hypoxia, and tumor-associated macrophage (TAM) infiltrates by immunohistochemistry. The origin of tumor endothelial cells was studied by green fluorescent protein-tagged bone marrow (GFP-BM) transplantation. The response of tumor endothelial cells to radiation and antiangiogenic agent was evaluated by apoptotic assay. Results: The pre-IR tumors had obvious tumor bed effects (TBE), with slower growth rate, lower microvascular density (MVD), and more necrotic and hypoxic fraction compared with control tumors. The vessels were dilated, tightly adhered with pericytes, and incorporated with transplanted GFP-BM cells. In addition, hypoxic regions became aggregated with TAM. As pre-IR tumors developed, the TBE was overcome at the tumor edge where the MVD increased, TAM did not aggregate, and the GFP-BM cells did not incorporate into the vessels. The vessels at tumor edge were more sensitive to the following ionizing radiation and antiangiogenic agent than those in the central low MVD regions. Conclusions: This study demonstrates that vasculatures in regions with TBE are mainly formed by vasculogenesis and resistant to radiation and antiangiogenic therapy. Tumor bed effects could be overcome at the edge of larger tumors, but where vasculatures are formed by angiogenesis and sensitive to both treatments. Vasculatures formed by vasculogenesis should be the crucial target for the treatment of recurrent tumors after radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Delineation of Internal Mammary Nodal Target Volumes in Breast Cancer Radiation Therapy

Purpose: The optimal clinical target volume for internal mammary (IM) node irradiation is uncertain in an era of increasingly conformal volume-based treatment planning for breast cancer. We mapped the location of gross internal mammary lymph node (IMN) metastases to identify areas at highest risk of harboring occult disease. Methods and Materials: Patients with axial imaging of IMN disease were identified from a breast cancer registry. The IMN location was transferred onto the corresponding anatomic position on representative axial computed tomography images of a patient in the treatment position and compared with consensus group guidelines of IMN target delineation. Results: The IMN location in 67 patients with 130 IMN metastases was mapped. The location was in the first 3 intercostal spaces in 102 of 130 nodal metastases (78%), whereas 18 of 130 IMNs (14%) were located caudal to the third intercostal space and 10 of 130 IMNs (8%) were located cranial to the first intercostal space. Of the 102 nodal metastases within the first 3 intercostal spaces, 54 (53%) were located within the Radiation Therapy Oncology Group consensus volume. Relative to the IM vessels, 19 nodal metastases (19%) were located medially with a mean distance of 2.2 mm (SD, 2.9 mm) whereas 29 (28%) were located laterally with a mean distance of 3.6 mm (SD, 2.5 mm). Ninety percent of lymph nodes within the first 3 intercostal spaces would have been encompassed within a 4-mm medial and lateral expansion on the IM vessels. Conclusions: In women with indications for elective IMN irradiation, a 4-mm medial and lateral expansion on the IM vessels may be appropriate. In women with known IMN involvement, cranial extension to the confluence of the IM vein with the brachiocephalic vein with or without caudal extension to the fourth or fifth interspace may be considered provided that normal tissue constraints are met.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptively remeshed multiphysical modeling of resistance forge welding with experimental validation of residual stress fields and measurement processes

Welding processes used in the production of pressure vessels impart residual stresses in the manufactured component. Computational modeling is critical to predicting these residual stress fields and understanding how they interact with notches and flaws to impact pressure vessel durability. Here, in this work, we present a finite element model for a resistance forge weld and validate it using laboratory measurements. Extensive microstructural changes, near-melt temperatures, and large localized deformations along the weld interface pose significant challenges to Lagrangian finite element modeling. The proposed modeling approach overcomes these roadblocks in order to provide a high-fidelity simulation that can predict the residual stress state in the manufactured pressure vessel; a rich microstructural constitutive model accounts for material recrystallization dynamics, a frictional-to-tied contact model is coordinated with the constitutive model to represent interfacial bonding, and adaptive remeshing is employed to alleviate severe mesh distortion. An interrupted-weld approach is applied to the simulation to facilitate comparison to displacement measures. Several techniques are employed for residual stress measurement in order to validate the finite element model: neutron diffraction, the contour method, and the slitting method. Model-measurement comparisons are supplemented with detailed simulations that reflect the configurations of the residual-stress measurement processes themselves. The model results show general agreement with experimental measurements, and we observe some similarities in the features around the weld region. Factors that contribute to model-measurement differences are identified. Finally, we conclude with some discussion of the model development and residual stress measurement strategies, including how to best leverage the efforts put forth here for other weld problems.

36 MATERIALS SCIENCE↗

A flow-through, elevated-temperature and -pressure NMR apparatus for in-situ CO 2 sequestration studies

Here we report an apparatus for in-situ nuclear magnetic resonance (NMR) studies of chemical reactions of dissolved 13 CO 2 with minerals (rock or powder) under continuous flow. The operating range of the apparatus is 18–150 °C and 1–140 bar. A flow pump is used to circulate a CO 2 -water solution, with a heated mixing vessel where CO 2 gas equilibrates with a water solution. The NMR probe is built around a strong zirconia ceramic vessel, with o-ring sealed connections; the mineral is contained inside. The horizontal orientation of the zirconia vessels allows use of a radio frequency (rf) solenoid for improved spin sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The variable influence of anthropogenic noise on summer season coastal underwater soundscapes near a port and marine reserve

Monitoring soundscapes is essential for assessing environmental conditions for soniferous species, yet little is known about sound levels and contributors in Oregon coastal regions. From 2017-2021, during June-September, two hydrophones were deployed near Newport, Oregon to sample 10-13,000Hz underwater sound. One hydrophone was deployed near the Port of Newport in a high vessel activity area, and another 17km north within a protected Marine Reserve. Vessel noise and whale vocalizations were detected at both sites, but whales were recorded on more days at the Marine Reserve. Median sound levels in frequencies related to noise from various vessel types and sizes (50-4,000Hz) were up to 6dB higher at the Port of Newport, with greater diel variability compared to the Marine Reserve. In addition to documenting summer season conditions in Oregon waters, these results exemplify how underwater soundscapes can differ over short distances depending on anthropogenic activity.

54 ENVIRONMENTAL SCIENCES↗

Unraveling the surface chemistry processes in lithiated and boronized plasma material interfaces under extreme conditions

The review of recent theoretical and experimental research on the complex surface chemistry processes that evolve from low-Z material conditioning on plasma-facing materials under extreme fusion plasma conditions is presented. A combination of multi-scale computational physics and chemistry modeling with real-time diagnosis of the plasma-material interface in tokamak fusion plasma edge is complemented by ex-vessel in-situ single-effect experimental facilities to unravel the evolving characteristics of low-Z components under irradiation. Effects of the lithium and boron coatings at carbon surfaces to the retention of deuterium and chemical sputtering of the plasma-facing surfaces are discussed in detail. The critical role of oxygen in the surface chemistry during hydrogen-fuel irradiation is found to drive the kinetics and dynamics of these surfaces as they interact with fusion edge plasma that ultimately could have profound effects on fusion plasma confinement behavior. Computational studies also extend in spatio-temporal scales not accessible by empirical means and therefore open the opportunity for a strategic approach at irradiation surface science studies that combined these powerful computational tools with in-vessel and ex-vessel in-situ diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Innovative laser-based methods for monitoring fuel retention in ITER

This paper addresses the challenge of tritium inventory management in ITER and future fusion reactors, highlighting the importance of accurate tritium measurement and its spatial distribution within the vacuum vessel. Given ITER’s operational constraints, especially the limit on tritium retention, precise measurement is essential for both safety and regulatory compliance. To tackle these questions, the paper presents the T-monitor diagnostic system developed by Forschungszentrum Jülich, which uses Laser-Induced Desorption (LID) in combination with Diagnostic Residual Gas Analysis (DRGA) to measure hydrogen isotope concentrations on the surface of divertor tiles. The system integrates a high-power laser, advanced optical components, and a Fast Scanning Mirror Unit (FSMU) for accurate laser spot positioning with rapid response. Designed to measure in situ tritium retention, the diagnostic provides high-resolution spatial mapping, vital for evaluating detritiation strategies. The laser heating process increases the divertor surface temperature to 1600 K within the laser spot, promoting hydrogen isotope desorption. Accurate measurements require the precise control of laser parameters, including pulse duration and spot size, with a target relative accuracy of 20%. The optical design includes both in-vessel and ex-vessel components, such as durable high-reflectivity mirrors made of gold and copper, selected not only for their infrared performance but also for their transmission of visible wavelengths for observation purposes. To protect optical components from contamination, a pneumatic shutter is used.

Hydrogen isotopes↗

Material Interactions in Severe Accidents – Benchmarking the MELCOR V2.2 Eutectics Model for a BWR-3 MARK-I Station Blackout: Part I – Single Case Analysis

Here in this analysis, the two material interaction models available in the MELCOR code are benchmarked for a severe accident at a BWR under representative Fukushima Daiichi boundary conditions. This part of the benchmark investigates the impact of each material interaction model on accident progression through a detailed single case analysis. It is found that the eutectics model simulation exhibits more rapid accident progression for the duration of the accident. The slower accident progression exhibited by the interactive materials model simulation, however, allows for a greater degree of core material oxidation and hydrogen generation to occur, as well as elevated core temperatures during the ex-vessel accident phase. The eutectics model simulation exhibits more significant degradation of core components during the late in-vessel accident phase – more debris forms and relocates to the lower plenum before lower head failure. The larger debris bed observed in the eutectics model simulation also reaches higher temperatures, presenting a more significant thermal challenge to the lower head until its failure. At the end of the simulated accident scenario, however, core damage is comparable between both simulations due to significant core degradation that occurs during the ex-vessel phase in the interactive materials model simulation. A key difference between the two models’ performance is the maximum temperatures that can be reached in the core and therefore the maximum ΔT between any two components. When implementing the interactive materials model, users have the option to modify the liquefaction temperature of the ZrO 2 -interactive and UO 2 -interactive materials as a way to mimic early fuel rod failure due to material interactions. Through modification of the liquefaction of high melting point materials with significant mass, users may inadvertently limit maximum core temperatures for fuel, cladding, and debris components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The anti-ALS drug riluzole attenuates pericyte loss in the diabetic retinopathy of streptozotocin-treated mice

Loss of pericytes, considered an early hallmark of diabetic retinopathy, is thought to involve abnormal activation of protein kinase C (PKC). We previously showed that the anti-amyotrophic lateral sclerosis (ALS) drug riluzole functions as a PKC inhibitor. Here, we examined the effects of riluzole on pathological changes in diabetic retinopathy. Pathological endpoints examined in vivo included the number of pericytes and integrity of retinal vessels in streptozotocin (STZ)-induced diabetic mice. In addition, PKC activation and the induction of monocyte chemotactic protein (MCP1) were assessed in diabetic mice and in human retinal pericytes exposed to advanced glycation end product (AGE) or modified low-density lipoprotein (mLDL). The diameter of retinal vessels and the number of pericytes were severely reduced, and the levels of MCP1 and PKC were increased in STZ-induced diabetic mice. Administration of riluzole reversed all of these changes. Furthermore, the increased expression of MCP1 in AGE- or mLDL-treated cultured retinal pericytes was inhibited by treatment with riluzole or the PKC inhibitor GF109203X. In silico modeling showed that riluzole fits well within the catalytic pocket of PKC. Taken together, our results demonstrate that riluzole attenuates both MCP1 induction and pericyte loss in diabetic retinopathy, likely through its direct inhibitory effect on PKC. - Highlights: • The effects of riluzole were examined in streptozotocin-induced diabetic mice. • The diameter of retinal vessels and the number of pericytes were severely reduced. • The levels of MCP1 and PKC were increased, while riluzole reversed all changes. • Riluzole attenuated the level of MCP1 in AGE- or mLDL-treated retinal pericytes. • Riluzole attenuated both MCP1 induction and pericyte loss in diabetic retinopathy.

60 APPLIED LIFE SCIENCES↗

Quantifying the reduction in cavitation-induced erosion damage in the Spallation Neutron Source mercury target by means of small-bubble gas injection

Here, a model developed to represent the progress of erosion damage in liquid-metal spallation target vessels was modified to incorporate the effect of gas injection on the erosion rate. The liquid mercury target system for the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory now operates with helium gas injection to reduce target vessel fatigue stress and cavitation-induced erosion damage. Erosion damage is a primary degradation phenomenon affecting the service life of SNS target vessels, and cavitation mitigation techniques, such as small-bubble gas injection, have been implemented to reduce damage and extend target lifetimes. Erosion depths in samples removed from SNS targets after operation were measured using laser line scanning. These measurements confirmed that gas injection reduced erosion damage. However, quantifying the damage reduction due to gas injection was complicated by variations in lifetime, power, and gas injection rates between different targets. In this study, the operating power and gas injection rate of targets were incorporated into an erosion damage prediction model to quantify their effects on erosion damage reduction. Values of a power scaling factor, β, were calculated by comparing modeled with measured erosion damage. These values indicate that the use of gas injection at the SNS reduced damage to a level equivalent to operating targets without gas injection at 35–47% of the actual beam power. To account for the gas injection effect on the cavitation damage, a simple exponential form based on analysis of the scaling factor β was developed to incorporate the gas rate history with a scaling factor γ in the erosion damage modeling.

47 OTHER INSTRUMENTATION↗

Refine your search to explore more results.