Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thickness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Measurement of thermal noise in multilayer coatings with optimized layer thickness

A standard quarter-wavelength multilayer optical coating will produce the highest reflectivity for a given number of coating layers, but in general it will not yield the lowest thermal noise for a prescribed reflectivity. Coatings with the layer thicknesses optimized to minimize thermal noise could be useful in future generation interferometric gravitational wave detectors where coating thermal noise is expected to limit the sensitivity of the instrument. We present the results of direct measurements of the thermal noise of a standard quarter-wavelength coating and a low noise optimized coating. The measurements indicate a reduction in thermal noise in line with modeling predictions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of brane thickness on microscopic tidal-charged black holes

We study the phenomenological implications stemming from the dependence of the tidal charge on the brane thickness L for the evaporation and decay of microscopic black holes. In general, the larger L, the longer are the black hole lifetimes and the greater their maximum mass for those cases in which the black hole can grow. In particular, we again find that tidal-charged black holes might live long enough to escape the detectors and even the gravitational field of the Earth, thus resulting in large amounts of missing energy. However, under no circumstances could TeV-scale black holes grow enough to enter the regime of Bondi accretion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Influence of dosing sequence and film thickness on structure and resistivity of Al-ZnO films grown by atomic layer deposition

Aluminum-doped zinc oxide (AZO) films were deposited onto amorphous silica substrates using an atomic layer deposition process with diethyl zinc (DEZ), trimethyl aluminum (TMA), and deionized water at 200 °C. Three different Al doping sequences were used at a ZnO:Al ratio of 11:1 within the films. A minimum film resistivity of 1.6 × 10{sup −3} Ω cm was produced using sequential dosing of DEZ, TMA, DEZ, followed by H{sub 2}O for the Al doping step. This “ZAZW” sequence yielded an AZO film resistivity that is independent of film thickness, crystallographic texture, and grain size, as determined by high resolution x-ray diffraction (XRD). A pseudo-Voigt analysis method yields values for grain sizes that are smaller than those calculated using other XRD methods. Anisotropic grain sizes or variations in crystallographic texture have minimal influence on film resistivity, which suggests that factors other than film texture, such as intragrain scattering, may be important in influencing film resistivity.

36 MATERIALS SCIENCE↗

Stoichiometry and thickness dependence of superconducting properties of niobium nitride thin films

The current technology used in linear particle accelerators is based on superconducting radio frequency (SRF) cavities fabricated from bulk niobium (Nb), which have smaller surface resistance and therefore dissipate less energy than traditional nonsuperconducting copper cavities. Using bulk Nb for the cavities has several advantages, which are discussed elsewhere; however, such SRF cavities have a material-dependent accelerating gradient limit. In order to overcome this fundamental limit, a multilayered coating has been proposed using layers of insulating and superconducting material applied to the interior surface of the cavity. The key to this multilayered model is to use superconducting thin films to exploit the potential field enhancement when these films are thinner than their London penetration depth. Such field enhancement has been demonstrated in MgB{sub 2} thin films; here, the authors consider films of another type-II superconductor, niobium nitride (NbN). The authors present their work correlating stoichiometry and superconducting properties in NbN thin films and discuss the thickness dependence of their superconducting properties, which is important for their potential use in the proposed multilayer structure. While there are some previous studies on the relationship between stoichiometry and critical temperature T{sub C}, the authors are the first to report on the correlation between stoichiometry and the lower critical field H{sub C1}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Narrow thermal hysteresis of NiTi shape memory alloy thin films with submicrometer thickness

NiTi shape memory alloy (SMA) thin films were fabricated using biased target ion beam deposition (BTIBD), which is a new technique for fabricating submicrometer-thick SMA thin films, and the capacity to exhibit shape memory behavior was investigated. The thermally induced shape memory effect (SME) was studied using the wafer curvature method to report the stress-temperature response. The films exhibited the SME in a temperature range above room temperature and a narrow thermal hysteresis with respect to previous reports. To confirm the underlying phase transformation, in situ x-ray diffraction was carried out in the corresponding phase transformation temperature range. The B2 to R-phase martensitic transformation occurs, and the R-phase transformation is stable with respect to the expected conversion to the B19′ martensite phase. The narrow hysteresis and stable R-phase are rationalized in terms of the unique properties of the BTIBD technique.

36 MATERIALS SCIENCE↗

SU-F-I-75: Half-Value Layer Thicknesses and Homogeneity Coefficients for Fluoroscopic X-Ray Beam Spectra Incorporating Spectral Filtration

Purpose: The purpose of this investigation is to quantify various first half-value-layers (HVLs), second HVLs and homogeneity coefficients (HCs) for a state-of-the-art fluoroscope utilizing spectral (copper) filtration. Methods: A Radcal (Monrovia, Ca) AccuPro dosimeter with a 10×6-6 calibrated ionization chamber was used to measure air kerma for radiographic x-ray exposures made on a Siemens (Erlangen, Germany) Artis ZeeGo fluoroscope operated in the service mode. The ionization chamber was centered in the x-ray beam at 72 cm from the focal spot with a source-to-image-distance of 120 cm. The collimators were introduced to limit the x-ray field to approximately 5 cm × 5 cm at the ionization chamber plane. Type-1100 aluminum filters, in 0.5 mm increments, were used to determine the HVL. Two HVL calculation methods were used, log-linear interpolation and Lambert-W interpolation as described by Mathieu [Med Phys, 38(8), 4546 (2011)]. Multiple measurements were made at 60, 80, 100, 120 kVp at spectral filtration thicknesses of 0, 0.1, 0.3, 0.6 and 0.9 mm. Results: First HVL, second HVL, and HCs are presented for the fluoroscopic x-ray beam spectra indicated above, with nearly identical results from the two interpolation methods. Accuracy of the set kVp was also determined and deviated less than 2%. First HVLs for fluoroscopic x-ray beam spectra without spectral filtration determined in our study were 7%–16% greater than previously published data by Fetterly et al. [Med Phys, 28, 205 (2001)]. However, the FDA minimum HVL requirements changed since that publication, requiring larger HVLs as of 2006. Additionally, x-ray tube and generator architecture have substantially changed over the last 15 years providing different beam spectra. Conclusion: X-ray beam quality characteristics for state-of-the-art fluoroscopes with spectral filtration have not been published. This study provides reference data which will be useful for defining beam qualities encountered on fluoroscopes using spectral filtration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-192: A Quick and Effective Method to Validate Patient’s Daily Setup and Geometry Changes Prior to Proton Treatment Delivery Based On Water Equivalent Thickness Projection Imaging (WETPI) for Head Neck Cancer (HNC) Patient

Purpose: With the implementation of Cone-beam Computed-Tomography (CBCT) in proton treatment, we introduces a quick and effective tool to verify the patient’s daily setup and geometry changes based on the Water-Equivalent-Thickness Projection-Image(WETPI) from individual beam angle. Methods: A bilateral head neck cancer(HNC) patient previously treated via VMAT was used in this study. The patient received 35 daily CBCT during the whole treatment and there is no significant weight change. The CT numbers of daily CBCTs were corrected by mapping the CT numbers from simulation CT via Deformable Image Registration(DIR). IMPT plan was generated using 4-field IMPT robust optimization (3.5% range and 3mm setup uncertainties) with beam angle 60, 135, 300, 225 degree. WETPI within CTV through all beam directions were calculated. 3%/3mm gamma index(GI) were used to provide a quantitative comparison between initial sim-CT and mapped daily CBCT. To simulate an extreme case where human error is involved, a couch bar was manually inserted in front of beam angle 225 degree of one CBCT. WETPI was compared in this scenario. Results: The average of GI passing rate of this patient from different beam angles throughout the treatment course is 91.5 ± 8.6. In the cases with low passing rate, it was found that the difference between shoulder and neck angle as well as the head rest often causes major deviation. This indicates that the most challenge in treating HNC is the setup around neck area. In the extreme case where a couch bar is accidently inserted in the beam line, GI passing rate drops to 52 from 95. Conclusion: WETPI and quantitative gamma analysis give clinicians, therapists and physicists a quick feedback of the patient’s setup accuracy or geometry changes. The tool could effectively avoid some human errors. Furthermore, this tool could be used potentially as an initial signal to trigger plan adaptation.

60 APPLIED LIFE SCIENCES↗

Dependence of the surface topology and raman scattering spectra of Ge{sub x}Si{sub 1-x}/Si films on the composition variation over the layer thickness

The surface topology and Raman scattering spectra of Ge{sub x}Si{sub 1-x}/Si(100) films are investigated in dependence of the composition variation over the film thickness. It is shown that the character of the Ge content variation in the Ge{sub x}Si{sub 1-x} alloy at the constant cumulative Ge fraction in the film (x{sub int} = 0.5) affects the surface morphology of the grown Ge{sub x}Si{sub 1-x}/Si layer. The heterostructures were grown by molecular-beam epitaxy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Amorphization of biperiodic domain structures in quasi-uniaxial magnetic films with a critical thickness

The behavior of biperiodic stripe domain structures in quasi-uniaxial magnetic films with a near-critical thickness is studied by scanning magnetic force microscopy and magnetooptical diffraction. In these films, antiphase and hybrid biperiodic domain structures are found to be absent, and the phase transitions between monoperiodic and in-phase biperiodic domain structures are shown to proceed through two-dimensional domain arrays that are amorphized in the arrangement of near-surface distortions in the domain-wall profile.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical Spectra of GaSe and GaS Crystals of Different Thicknesses

The transmission spectra of GaSe and GaS crystals of different thicknesses prepared by mechanical stratification of bulk crystals have been investigated. The quantum-size shifts of exciton resonances in thin GaSe samples are as high as 12 meV, which is close to the exciton binding energy. The high-energy interband transitions in GaSe and GaS are observed near 3.4 and 3.7 eV, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Influence of Film Thickness on Annealing-Induced Grain Growth in Pt Films

Pt films with thickness h = 20–100 nm deposited on oxidized с-Si(100) substrate have been subjected to vacuum annealing at 500°C for 1 h, which resulted in recrystallization and growth of grains. Simultaneously with the normal growth of grains, abnormal grain growth has been observed, as a result of which the grains have separated in normal and secondary grains. For h = 20–40 nm, the secondary grains become much larger than the normal ones and the grain lateral size distribution therefore becomes bimodal. It has been shown that the abnormal grain growth rate increases with decreasing h, whereas the normal grain growth rate is independent of h. From the Pt(111) and Pt(222) X-ray diffraction peaks analysis it follows that the mean size D of coherently diffracting domains increases as a result of annealing. In the annealed films, D sublinearly grows with h, whereas in the as-prepared films, D grows linearly.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonmonotonic Change in the Tunnel Conductivity of an MIS Structure with a Two-Layer Insulator with an Increase in Its Thickness (by the Example of the Metal/SiO{sub 2}/CaF{sub 2}/Si System)

The effect of increasing the tunnel current in a metal–calcium fluoride–silicon structure with addition of a silicon dioxide layer between fluoride and metal (which seems paradoxical at first glance) has been considered. This effect of nonmonotonic change in the tunnel conductivity with an increase in the insulator thickness may occur at a relatively high bias at the structure and is related to the tunnel-barrier deformation, at which electrons are tunneling through its part formed by the oxide. At low biases, the occurrence/ thickening of an additional layer leads to a natural decrease in the current. Similar behavior is possible in principle for some other combinations of materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessing the Thickness of Thin Films Based on Elemental Data Composition of Film Structures

Abstract—We demonstrate the possibility of a quantitative assessment of the thickness of thin films using to measurements of the cationic composition of film structures using the INCA Energy-350 energy dispersion spectrometer that is part of the JSM-6490 LV electron microscope (Japan). The use of this method is especially useful if it is impossible to provide sufficient contrast between the images of the film and substrate sections obtained with a scanning electron microscope on a transverse cleavage of the film structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Thick-Restart Lanczos Algorithm with Polynomial Filtering for Hermitian Eigenvalue Problems

Polynomial filtering can provide a highly effective means of computing all eigenvalues of a real symmetric (or complex Hermitian) matrix that are located in a given interval, anywhere in the spectrum. This paper describes a technique for tackling this problem by combining a thick-restart version of the Lanczos algorithm with deflation ("locking'') and a new type of polynomial filter obtained from a least-squares technique. Furthermore, the resulting algorithm can be utilized in a “spectrum-slicing” approach whereby a very large number of eigenvalues and associated eigenvectors of the matrix are computed by extracting eigenpairs located in different subintervals independently from one another.

97 MATHEMATICS AND COMPUTING↗

Spatial coherence effect on layer thickness determination in narrowband full-field optical coherence tomography

Longitudinal spatial coherence (LSC) is determined by the spatial frequency content of an optical beam. The use of lenses with a high numerical aperture (NA) in full-field optical coherence tomography and a narrowband light source makes the LSC length much shorter than the temporal coherence length, hence suggesting that high-resolution 3D images of biological and multilayered samples can be obtained based on the low LSC. A simplified model is derived, supported by experimental results, which describes the expected interference output signal of multilayered samples when high-NA lenses are used together with a narrowband light source. An expression for the correction factor for the layer thickness determination is found valid for high-NA objectives. Additionally, the method was applied to a strongly scattering layer, demonstrating the potential of this method for high-resolution imaging of scattering media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-accuracy thickness measurement of a transparent plate with the heterodyne central fringe identification technique

In a modified Twyman-Green interferometer, the optical path variation is measured with the heterodyne central fringe identification technique, as the light beam is focused by a displaced microscopic objective on the front/rear surface of the test transparent plate. The optical path length variation is then measured similarly after the test plate is removed. The geometrical thickness of the test plate can be calculated under the consideration of dispersion effect. This method has a wide measurable range and a high accuracy in the measurable range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

buffer Layer Growth, the Thickness Dependence of Jc in Coated Conductors, Local Identification of Current Limiting Mechanisms and Participation in the Wire Development Group

The primary thrusts of our work were to provide critical understanding of how best to enhance the current-carrying capacity of coated conductors. These include the deconstruction of Jc as a function of fim thickness, the growth of in situ films incorporating strong pinning centers and the use of a suite of position-sensitive tools that enable location and analysis of key areas where current-limiting occurs.

36 MATERIALS SCIENCE↗

Refine your search to explore more results.