Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Efficient Simulation and Abuse Modeling of Mechanical-Electrochemical-Thermal Phenomena in Lithium-Ion Batteries

NREL's Energy Storage team is exploring the effect of mechanical crush of lithium ion cells on their thermal and electrical safety. PHEV cells, fresh as well as ones aged over 8 months under different temperatures, voltage windows, and charging rates, were subjected to destructive physical analysis. Constitutive relationship and failure criteria were developed for the electrodes, separator as well as packaging material. The mechanical models capture well, the various modes of failure across different cell components. Cell level validation is being conducted by Sandia National Laboratories.

25 ENERGY STORAGE↗

Improved thermoelectric performance of (Fe,Co)Sb{sub 3}-type skutterudites from first-principles

Skutterudite materials have been considered as promising thermoelectric candidates due to intrinsically good electrical conductivity and tailorable thermal conductivity. Options for improving thermal-to-electrical conversion efficiency include identifying novel materials, adding filler atoms, and substitutional dopants. Incorporating filler or substitutional dopant atoms in the skutterudite compounds can enhance phonon scattering, resulting in reduction of thermal conductivity, as well as improving electrical conductivity. The structures, electronic properties, and thermal properties of double-filled Ca{sub 0.5}Ce{sub 0.5}Fe{sub 4}Sb{sub 12} and Co{sub 4}Sb{sub 12−2x}Te{sub x}Ge{sub x} compounds (x = 0, 0.5, 1, 2, 3, and 6) have been studied using density functional theory-based calculations. Both Ca/Ce filler atoms in FeSb{sub 3} and Te/Ge substitution in CoSb{sub 3} cause a decrease in lattice constant for the compounds. As Te/Ge substitution concentration increases, lattice constant decreases and structural distortion of pnictogen rings in the compounds occurs. This indicates a break in cubic symmetry of the structure. The presence of fillers and substitutions cause an increase in electrical conductivity and a gradual decrease in electronic band gap. A transition from direct to indirect band-gap semiconducting behavior is found at x = 3. Phonon density of states for both compounds indicate phonon band broadening by the incorporation of fillers and substitutional atoms. Both systems are also assumed to have acoustic-mode-dominated lattice thermal conductivity. For the Co{sub 4}Sb{sub 12−2x}Te{sub x}Ge{sub x} compounds, x = 3 has the lowest phonon dispersion gradient and lattice thermal conductivity, agreeing well with experimental measurements. Our results exhibit the improvement of thermoelectric properties of skutterudite compounds through fillers and substitutional doping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High performance terahertz metasurface quantum-cascade VECSEL with an intra-cryostat cavity

A terahertz quantum-cascade (QC) vertical-external-cavity surface-emitting-laser (VECSEL) is demonstrated with over 5 mW power in continuous-wave and single-mode operation above 77 K, in combination with a near-Gaussian beam pattern with full-width half-max divergence as narrow as ~5° × 5°, with no evidence of thermal lensing. This is realized by creating an intra-cryostat VECSEL cavity to reduce the cavity loss and designing an active focusing metasurface reflector with low power dissipation for efficient heat removal. Compared with a conventional quantumcascade laser based on a metal-metal waveguide, the intra-cryostat QC-VECSEL exhibits significant improvements in both output power level and beam pattern. Also, the intra-cryostat configuration newly allows evaluation of QC-VECSEL operation vs. temperature, showing a maximum pulsed mode operating temperature of 129 K. While the threshold current density in the QC-VECSEL is worse in comparison to a conventional edge-emitting metal-metal waveguide QClaser, the beam quality, slope efficiency, maximum power, and thermal resistance are all significantly improved.

47 OTHER INSTRUMENTATION↗

Grid Interactive Micro-Distributed Display Case

The goal of this project is to design, fabricate and validate the performance of an economically viable next-generation self-contained, refrigerated open vertical display case with integrated thermal storage that improves energy efficiency, enhances demand flexibility, uses an environmentally friendly refrigerant, improves human comfort

25 ENERGY STORAGE↗

Energy to Communities Program Short Introduction: Evaluation of Enhanced Geothermal System for Cornell District Heating [Slides]

Through the U.S. Department of Energy's Energy to Communities (E2C) program, NLR, other national laboratory experts, and select organizations provide Expert Match - free, short-term technical assistance to address near-term energy challenges and questions. Expert Match is for community stakeholders who have decision-making power or influence in their community but need access to additional energy expertise to inform key upcoming decisions. This Expert Match request supported Cornell University (Itaca, NY) community efforts in developing Enhanced Geothermal System (EGS) reservoir performance, by simulating fracture flow to estimate pressure drop, flow distribution, and heat extraction efficiency in fractured rock. Thermal drawdown modeling was used to assess long-term resource sustainability, while system optimization studies refined key parameters such as well configuration and flow rate to improve overall reservoir efficiency.

15 GEOTHERMAL ENERGY↗

Performance Evaluation for Modular, Scalable Overhead Cooling Systems In Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants' input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 1. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable overhead cooling system. The system was tested in a hot/cold aisle environment without separation, or containment or the hot or cold aisles. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Cooling Systems with Hot Aisle Containment in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. Naturally, the trend toward higher power density resulting from current and future generations of servers has, in the meanwhile, created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 2. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable pair of chilled water cooling modules that were tested in a hot/cold aisle environment with hot aisle containment. The scope of this report is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures. The information generated from this testing when combined with a concurrent research study to document the energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for Modular, Scalable Liquid-Rack Cooling Systems in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling suppliers to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected modular localized cooling solution provided by vendor 3. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a modular, scalable liquid-rack cooling system in this study. The scope is to quantify energy performance of the modular cooling unit in operation as it corresponds to a combination of varied server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation for a Modular, Scalable Passive Cooling System in Data Centers

Scientific and enterprise data centers, IT equipment product development, and research data center laboratories typically require continuous cooling to control inlet air temperatures within recommended operating levels for the IT equipment. The consolidation and higher density aggregation of slim computing, storage and networking hardware has resulted in higher power density than what the raised-floor system design, coupled with commonly used computer rack air conditioning (CRAC) units, was originally conceived to handle. Many existing data centers and newly constructed data centers adopt CRAC units, which inherently handle heat transfer within data centers via air as the heat transfer media. This results in energy performance of the ventilation and cooling systems being less than optimal. Understanding the current trends toward higher power density in IT computing, more and more IT equipment manufacturers are designing their equipment to operate in 'conventional' data center environments, while considering provisions of alternative cooling solutions to either their equipment or supplemental cooling in rack or row systems. In the meanwhile, the trend toward higher power density resulting from current and future generations of servers has created significant opportunities for precision cooling to engineer and manufacture packaged modular and scalable systems. The modular and scalable cooling systems aim at significantly improving efficiency while addressing the thermal challenges, improving reliability, and allowing for future needs and growth. Such pre-engineered and manufactured systems may be a significant improvement over current design; however, without an energy efficiency focus, their applications could also lead to even lower energy efficiencies in the overall data center infrastructure. The overall goal of the project supported by California Energy Commission was to characterize four commercially available, modular cooling systems installed in a data center. Such modular cooling systems are all scalable localized units, and will be evaluated in terms of their operating energy efficiency in a real data center, respectively, as compared to the energy efficiency of traditional legacy data center cooling systems. The technical objective of this project was to evaluate the energy performance of one of the four commercially available modular cooling systems installed in a data center in Sun Microsystems, Inc. This report is the result of a test plan that was developed with the industrial participants input, including specific design and operating characteristics of the selected passive, modular localized cooling solution provided by vendor 4. The technical evaluation included monitoring and measurement of selected parameters, and establishing and calculating energy efficiency metrics for the selected cooling product, which is a passive, modular, scalable liquid cooling system in this study. The scope is to quantify energy performance of the modular cooling unit corresponding to various server loads and inlet air temperatures, under various chilled-water supply temperatures. The information generated from this testing when combined with documented energy efficiency of the host data center's central chilled water cooling plant can be used to estimate potential energy savings from implementing modular cooling compared to conventional cooling in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel multifunctional energy system (MES) for CO{sub 2} removal with zero energy penalty - article no. 021401

This paper proposes a novel, multifunctional energy system (MES), in which hydrogen and electricity are cogenerated and about 90% of CO{sub 2} is removed. By integrating the methane steam reforming reaction and combustion of coal, the natural gas and coal are utilized synthetically, and coal is burned to provide high-temperature thermal energy to the methane steam reforming reaction. Afterwards, the resulting syngas enters a pressure swing adsorption (PSA) unit to separate about 70% of hydrogen, thereby significantly increasing the concentration of carbon dioxide from nearly 20% to 43% in the PSA tail gas. As a result, the overall efficiency of the new system becomes 63.2%. Compared to a conventional natural gas-based hydrogen plant and a coal-firing steam power plant without CO{sub 2} removal (the overall efficiency of the two systems is 63.0%), the energy penalty for CO{sub 2} removal in the new system is almost totally avoided. Based on the graphical exergy analysis, we propose that the integration of synthetic utilization of fossil fuel (natural gas and coal) and the CO{sub 2} removal process plays a significant role in zero energy penalty for CO{sub 2} removal and its liquefaction in the MES. The result obtained here provides a new approach for CO{sub 2} removal with zero or low thermal efficiency reduction (energy penalty) within an energy system.

20 FOSSIL-FUELED POWER PLANTS↗

Performance of a 300-horsepower Hispano-Suiza airplane engine

The National Bureau of Standards tested a 300-horsepower Hispano-Suiza engine to determine the characteristic performance of the engine at various altitudes. The engine was operated at the ground, at 25,000 feet, and at intermediate altitudes, both at full loads similar to those that would be imposed upon the engine at various speeds by a propeller whose normal full-load speed was 1,800 r.p.m. Friction horsepower also was determined in order that the mechanical efficiency of the engine might be calculated. From the test data there were computed the brake horsepower, brake mean effective pressure, specific fuel consumption, mixture ratio, jacket loss, exhaust loss, and thermal, mechanical, and volumetric efficiencies. A record of jacket water temperatures, oil temperatures, manifold pressures, etc., shows the conditions under which the test was made.

Sparrow, S W↗

Electric Aircraft Thermal Management Using a Two-Phase Heat Transport System with Solid-State Thermal Switching Capability

Advanced Cooling Technologies, Inc. (ACT) is collaborating with NASA Glenn Research Center (GRC) to develop a heat pipe-based thermal delivery system to efficiently manage the waste heat generated onboard an electric aircraft. The heat pipe system will interface with NASA GRC’s thermoacoustic heat pump in order to recycle waste heat by transporting thermal energy to various end users onboard the aircraft. This paper discusses the layout of theoretical heat pipe networks for a MW-class commercial electric aircraft. This is followed by a discussion of progress made on the development of a novel two-phase heat transport system with solid-state thermal switching and control capabilities.

Exergy↗

Control over the resonance wavelength of fibre Bragg gratings using resistive coatings based on single-wall carbon nanotubes

We demonstrate that a thin resistive coating based on single-wall carbon nanotubes applied to the lateral surface of an optical fibre allows it to be uniformly heated up to a temperature of ∼400{sup ∘}C without damage to the coating. Using a fibre Bragg grating (FBG) as an example, we assess the efficiency of resonance wavelength thermal tuning and examine frequency characteristics that can be achieved using such coating. In particular, we show that the resonance wavelength of the FBG can be tuned over 3.2 nm with an efficiency of 8.7 nm W{sup −1} and time constant of ∼0.4 s. (paper)

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Asymmetric Dark Matter and Dark Radiation

Asymmetric Dark Matter (ADM) models invoke a particle-antiparticle asymmetry, similar to the one observed in the Baryon sector, to account for the Dark Matter (DM) abundance. Both asymmetries are usually generated by the same mechanism and generally related, thus predicting DM masses around 5 GeV in order to obtain the correct density. The main challenge for successful models is to ensure efficient annihilation of the thermally produced symmetric component of such a light DM candidate without violating constraints from collider or direct searches. A common way to overcome this involves a light mediator, into which DM can efficiently annihilate and which subsequently decays into Standard Model particles. Here we explore the scenario where the light mediator decays instead into lighter degrees of freedom in the dark sector that act as radiation in the early Universe. While this assumption makes indirect DM searches challenging, it leads to signals of extra radiation at BBN and CMB. Under certain conditions, precise measurements of the number of relativistic species, such as those expected from the Planck satellite, can provide information on the structure of the dark sector. We also discuss the constraints of the interactions between DM and Dark Radiation from their imprint in the matter power spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

Acceleration of interstellar pickup ions in the disturbed solar wind observed on Ulysses

Acceleration of interstellar pickup H(+) and He(+) as well as of solar wind protons and alpha particles has been observed on Ulysses during the passage of a corotating interaction region (CIR) at approximately 4.5 AU. Injection efficiencies for both the high thermal speed interstellar pickup ions (H(+) and He(+)) and the low thermal speed solar wind ions (H(+) and He(++) are derived using velocity distribution functions of protons, pickup He(+) and alpha particles from less than 1 to 60 keV/e and of ions (principally protons) above approximately 60 keV. The observed spatial variations of the few keV and the few hundred keV accelerated pickup protons across the forward shock of CIR indicate a two stage acceleration mechanism. Thermal ions are first accelerated to speeds of 3 to 4 times the solar wind speed inside the CIR, presumably by some statistical mechanism, before reaching higher energies by a shock acceleration process. Our results also indicate that (1) the injection efficiencies for pickup ions are almost 100 times higher than they are for solar wind ions, (2) pickup H(+) and He(+) are the two most abundant suprathermal ion species and they carry a large fraction of the particle thermal pressure, (3) the injection efficiency is highest for protons, lowest for He(+), and intermediate for alpha particles, (4) both H(+) and He(+) have identical spectral shapes above the cutoff speed for pickup ions, and (5) the solar wind frame velocity distribution function of protons has the form F(w) = F(sub o)w(sup -4) for 1 is less than w is less than approximately 5, where w is the ion speed divided by the solar wind speed. Above w approximately 5-10 the proton spectrum becomes steeper. These results have important implications concerning acceleration of ions by shocks and CIRs, acceleration of anomalous cosmic rays, and particle dynamics in the outer heliosphere.

Gloeckler, G.↗

Power Electronics Thermal Management

This project develops thermal management strategies to enable efficient and high-temperature wide-bandgap (WBG)-based power electronic systems (e.g., emerging inverter and DC-DC converter designs). The use of WBG-based devices in automotive power electronics will improve efficiency and increase driving range in electric-drive vehicles; however, the implementation of this technology is limited, in part, due to thermal issues. This project will develop system-level thermal models to determine the thermal limitations of current automotive power modules under elevated device temperature conditions. Additionally, novel cooling concepts and material selection will be evaluated to enable high-temperature silicon and WBG devices in power electronics components. WBG devices (silicon carbide [SiC], gallium nitride [GaN]) promise to increase efficiency, but will be driven as hard as possible. This creates challenges for thermal management and reliability. This project is a Vehicle Technologies Office, U.S. Department of Energy Office of Energy Efficiency and Renewable Energy funded project.

30 DIRECT ENERGY CONVERSION↗

3.6 and 4.5 μm Spitzer phase curves of the highly irradiated hot jupiters WASP-19b and HAT-P-7b

We analyze full-orbit phase curve observations of the transiting hot Jupiters WASP-19b and HAT-P-7b at 3.6 and 4.5 μm, obtained using the Spitzer Space Telescope. For WASP-19b, we measure secondary eclipse depths of 0.485%±0.024% and 0.584%±0.029% at 3.6 and 4.5 μm, which are consistent with a single blackbody with effective temperature 2372 ± 60 K. The measured 3.6 and 4.5 μm secondary eclipse depths for HAT-P-7b are 0.156%±0.009% and 0.190%±0.006%, which are well described by a single blackbody with effective temperature 2667 ± 57 K. Comparing the phase curves to the predictions of one-dimensional and three-dimensional atmospheric models, we find that WASP-19b’s dayside emission is consistent with a model atmosphere with no dayside thermal inversion and moderately efficient day–night circulation. We also detect an eastward-shifted hotspot, which suggests the presence of a superrotating equatorial jet. In contrast, HAT-P-7b’s dayside emission suggests a dayside thermal inversion and relatively inefficient day–night circulation; no hotspot shift is detected. For both planets, these same models do not agree with the measured nightside emission. The discrepancies in the model-data comparisons for WASP-19b might be explained by high-altitude silicate clouds on the nightside and/or high atmospheric metallicity, while the very low 3.6 μm nightside planetary brightness for HAT-P-7b may be indicative of an enhanced global C/O ratio. We compute Bond albedos of 0.38 ± 0.06 and 0 (<0.08 at 1σ) for WASP-19b and HAT-P-7b, respectively. In the context of other planets with thermal phase curve measurements, we show that WASP-19b and HAT-P-7b fit the general trend of decreasing day–night heat recirculation with increasing irradiation.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental Confirmation of Powerstick Concept

The results relating to the development and testing of the miniature Radioisotope Thermoelectric Generator (RTG)-like Powerstick (PS) device are presented. They confirm the earlier ideas and predictions regarding possible manufacturing of PS-devices. PS is based on a 238-Pu standard Radioactive Heating Unit (RHU) with thermal power 1.1 W developed and manufactured by DOE and successfully being used on spacecraft (Galileo, Cassini, e. g.). In the course of development, several design approaches were explored and achieving high PS efficiencies was considered. Better thermal insulation material (with thermal conductivity 0.02 W/mK) has been developed and used and different designs of PS were evaluated. Two types of PS were manufactured: PS-1, on the basis of one RHU and one thermoelectric battery/converter (TEB), and PS-2, on the basis of two RHU and one TEB. Two different sizes of TEB were used: first - with the legs of cross-section 0.45x0.45 sq-mm and height 35 mm, and second - with the legs of cross-section 0.6Ox0.60 sq-m and height 35 mm. In both cases, the number of legs was 400. The electrical power of the PS-1 was observed to deliver 22 mW at 2.5 V and for PS-2 - 53 mW at 4.1 V. The analysis of results showed that optimized version of PS-2 should be capable of more than 70 mW at 5 V, on the basis of TEB with legs of cross-section 0.67x0.67 sq-mm and height 40 mm with number of legs 324.

Pustovalov, A.↗

Refine your search to explore more results.