Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Analysis of Underground Storage Tanks System Materials to Increased Leak Potential Associated with E15 Fuel

The Energy Independence and Security Act (EISA) of 2007 was enacted by Congress to move the nation toward increased energy independence by increasing the production of renewable fuels to meet its transportation energy needs. The law establishes a new renewable fuel standard (RFS) that requires the nation to use 36 billion gallons annually (2.3 million barrels per day) of renewable fuel in its vehicles by 2022. Ethanol is the most widely used renewable fuel in the US, and its production has grown dramatically over the past decade. According to EISA and RFS, ethanol (produced from corn as well as cellulosic feedstocks) will make up the vast majority of the new renewable fuel requirements. However, ethanol use limited to E10 and E85 (in the case of flex fuel vehicles or FFVs) will not meet this target. Even if all of the E0 gasoline dispensers in the country were converted to E10, such sales would represent only about 15 billion gallons per year. If 15% ethanol, rather than 10% were used, the potential would be up to 22 billion gallons. The vast majority of ethanol used in the United States is blended with gasoline to create E10, that is, gasoline with up to 10% ethanol. The remaining ethanol is sold in the form of E85, a gasoline blend with as much as 85% ethanol that can only be used in FFVs. Although DOE remains committed to expanding the E85 infrastructure, that market will not be able to absorb projected volumes of ethanol in the near term. Given this reality, DOE and others have begun assessing the viability of using intermediate ethanol blends as one way to transition to higher volumes of ethanol. In October of 2010, the EPA granted a partial waiver to the Clean Air Act allowing the use of fuel that contains up to 15% ethanol for the model year 2007 and newer light-duty motor vehicles. This waiver represents the first of a number of actions that are needed to move toward the commercialization of E15 gasoline blends. On January 2011, this waiver was expanded to include model year 2001 light-duty vehicles, but specifically prohibited use in motorcycles and off-road vehicles and equipment. UST stakeholders generally consider fueling infrastructure materials designed for use with E0 to be adequate for use with E10, and there are no known instances of major leaks or failures directly attributable to ethanol use. It is conceivable that many compatibility issues, including accelerated corrosion, do arise and are corrected onsite and, therefore do not lead to a release. However, there is some concern that higher ethanol concentrations, such as E15 or E20, may be incompatible with current materials used in standard gasoline fueling hardware. In the summer of 2008, DOE recognized the need to assess the impact of intermediate blends of ethanol on the fueling infrastructure, specifically located at the fueling station. This includes the dispenser and hanging hardware, the underground storage tank, and associated piping. The DOE program has been co-led and funded by the Office of the Biomass Program and Vehicle Technologies Program with technical expertise from the Oak Ridge National Laboratory (ORNL) and the National Renewable Energy Laboratory (NREL). The infrastructure material compatibility work has been supported through strong collaborations and testing at Underwriters Laboratories (UL). ORNL performed a compatibility study investigating the compatibility of fuel infrastructure materials to gasoline containing intermediate levels of ethanol. These results can be found in the ORNL report entitled Intermediate Ethanol Blends Infrastructure Materials Compatibility Study: Elastomers, Metals and Sealants (hereafter referred to as the ORNL intermediate blends material compatibility study). These materials included elastomers, plastics, metals and sealants typically found in fuel dispenser infrastructure. The test fuels evaluated in the ORNL study were SAE standard test fuel formulations used to assess material-fuel compatibility within a relatively short timeframe. Initially, these material studies included test fuels of Fuel C, CE10a, CE17a, and CE25a. The CE17a test fuel was selected to represent E15 since surveys have shown that the actual ethanol upper limit can be as high as 17%. Later, CE50a and CE85a test fuels were added to the investigation and these results are being compiled for a follow-on report to be published in 2012. Fuel C was used as the baseline reference and is a 50:50 blend of isooctane and toluene. This particular composition was used to represent premium-grade gasoline and was also used as the base fuel for the ethanol blends, where it is denoted by 'C' in the fuel name. The level of ethanol is represented by the number following the letter E. Therefore a 10% blend of ethanol in Fuel C is written as CE10a, where 'a' represents an aggressive formulation of the ethanol that contains water, NaCl, acetic and sulfuric acids per the SAE J1681 protocol.

02 PETROLEUM↗

Fabrication and testing of sealed silver-zinc cells

A number of Type HS40-7 sealed silver-zinc cells and experimental 40AH sealed silver-zinc cells were fabricated. Cells of each experimental group contained one variation from the standard configuration (HS40-7) cell. Cells from each of five experimental cell groups and cells of the standard configuration were tested to characterize voltage and capacity performance at various discharge rates. The test cells were then subjected to 100 percent DOD Cycle Life Testing at 22 C. Results indicate that material and/or process variations are available which will improve both performance and cycle life of the existing 40 ampere-hour sealed silver-zinc cell configurations. The average cycle life to 50 percent loss of nominal capacity in cells from two (2) of the experimental groups was 150 - 165 cycles. A series of 12 ampere-hour cells was fabricated and tested as part of a program to incorporate the 40AH sealed silver-zinc cell fabrication technology into a cell of smaller size. Base-line configuration cells and experimental variations were produced using the HS40-7 cell fabrication and processing methods adapted to the smaller cell size.

Donnel, C. P., III↗

NESHAP Annual Report for CY 2015 Sandia National Laboratories Tonopah Test Range

This National Emission Standards for Hazardous Air Pollutants (NESHAP) Annual Report has been prepared in a format to comply with the reporting requirements of 40 CFR 61.94 and the April 5, 1995 Memorandum of Agreement (MOA) between the Department of Energy (DOE) and the Environmental Protection Agency (EPA). According to the EPA approved NESHAP Monitoring Plan for the Tonopah Test Range (TTR), 40 CFR 61, subpart H, and the MOA, no additional monitoring or measurements are required at TTR in order to demonstrate compliance with the NESHAP regulation.

54 ENVIRONMENTAL SCIENCES↗

Spacecraft signal sources portable test system

There is a frequent need to measure the frequency stability and phase noise levels of very high performance signal sources that are required for certain spacecraft missions. These measurements need to be done at different locations as the spacecraft subsystems progress through the various stages of development, assembly, test, and integration. Allan Deviation and Phase Noise of high performance sources are generally measured by comparing the unit under test to a reference standard. Five basic requirements are associated with making these kind of measurements: (1) the reference standard performance needs to be equal or better than the unit under test; (2) the measurement system needs to accommodate odd, nonstandard measurement frequencies that can range from 4 MHz to 35 GHz; (3) warm-up frequency drift and aging can corrupt a measurement and must be dealt with; (4) test equipment generated noise must be understood and prevented from limiting the measurements; (5) test equipment noise performance must be verifiable in the field as needed. A portable measurement system that was built by JPL and used in the field is described. The methods of addressing the above requirements are outlined and some measurement noise floor values are given. This test set was recently used to measure state of the art crystal oscillator frequency standards on the TOPEX and MARS OBSERVER spacecraft during several stages of acceptance tests.

Kirk, Albert↗

The novel Mechanical Ventilator Milano for the COVID-19 pandemic

This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Furthermore, following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world

60 APPLIED LIFE SCIENCES↗

How the Recent BaBar Data for P to Gamma Gamma* Affect the Standard Model Predictions for the Rare Decays P to L+ L-

Measuring the lepton anomalous magnetic moments (g-2) and the rare decays of light pseudoscalar mesons into lepton pairs P {yields} l{sup +}l{sup -}, serve as important tests of the Standard Model. To reduce the theoretical uncertainty in the standard model predictions, the data on the charge and transition form factors of the light pseudoscalar mesons play a significant role. Recently, new data on the behavior of the transition form factors P {yields} {gamma}{gamma}* at large momentum transfer were supplied by the BABAR collaboration. There are several problems with the theoretical interpretation of these data: (1) An unexpectedly slow decrease of the pion transition form factor at high momenta, (2) the qualitative difference in the behavior of the pion form factor and the {eta} and {eta}' form factors at high momenta, (3) the inconsistency of the measured ratio of the {eta} and {eta}' form factors with the predicted one. We comment on the influence of the new BABAR data on the rare decay branchings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reproducibility and Repeatability of Tensile and Low-Cycle Fatigue Properties in Propulsion Grade Hydrogen

Hydrogen has the potential of increased use in the future as an environmentally friendly fuel. It has, however, shown a tendency to embrittle some materials. To be used in a safe manner and to exploit its full potential, it will be necessary to develop a database of material properties in hydrogen environment. The tests needed to produce this data are costly to perform (tensile test cost 25 times more and low cycle fatigue test are 55 times as expensive). Moreover, there is presently a lack of universal test methods to ensure standardized data within the hydrogen community. Each of the industries that work with hydrogen (aerospace, petroleum, fuel cells, etc.) performs tests by their own laboratory-developed methods, thus rendering cross- comparisons of material property data highly questionable. It is extremely important that data generated in a hydrogen environment be done to a standard that reduces variance to a minimum and allows direct comparison of test results from different laboratories. Doing so will assure that all data generated can be used to further our understanding of the hydrogen effects and to make sure components/products designed for hydrogen are the safest and most reliable possible. This paper reviews the results of two 'round-robin' programs conducted by NASA-MSFC. These two programs examined the reproducibility and repeatability of tensile and low-cycle fatigue test results in high-pressure hydrogen environments. The studies indicated that even with the tightest controls available from current commercial standards, the reproducibility (between different laboratories) and repeatability (within a laboratory) results of the tensile tests exhibited five times the variance as in standard ambient air tests. The variance with the LCF tests were on the same order as with air tests, but that was due to the large variation present in the last Interlaboratory air program. The paper concludes with a recommendation for a program that would allow the development of improved test methods, leading to lower variance in the generation of mechanical property data in the future.

Vesely, E. J.↗

Evaluating the Performance of Island Kitchen Range Hoods

A key aspect of achieving acceptable indoor air quality is source control. Cooking has been recognized as a significant source of pollutants for health impacts (e.g., PM2.5 and NO2) as well as moisture and odour. A common method of controlling this pollutant source is by using a range (or cooker) hood that vents to outside. However, field and laboratory experiments have shown highly variable performance for these devices. We use the capture efficiency metric (the fraction of the pollutants that are exhausted to outside at steady state) to characterize the range hood performance. To address this issue and provide useful information for builders, contractors, designers and home occupants, a laboratory rating method for range hood capture efficiency has recently been developed by LBNL and ASTM. The test method uses standardized emitters to create a heated plume and seed it with tracer gas. The tracer gas measurements in the room, the range hood exhaust and in the ambient air are used to estimate capture efficiency. However, this test method only applies to wall-mounted range hoods. Some range hoods are not wall-mounted: island range hoods are designed to operate over a cooktop in the middle of a room rather than against a wall and downdraft hoods draw air from near the cooktop rather than overhead. This paper discusses the development of a new test apparatus for island and downdraft hoods and presents measured capture efficiency data from example hoods. The results of this work will be used in future revisions to the ASTM standard.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of ANSI N42.34 – American National Standard Performance Criteria for Hand-Held Instruments for the Detection and Identification of Radionuclides

SRNL’s validation of ANSI N42.34-D6 for the Domestic Nuclear Detection Office (DNDO) was performed utilizing one hand-held instrument (or RID) – the FLIR identiFINDER 2. Each section of the standard was evaluated via a walk-through or test. NOTE: In Table 1, W = walk-through and T = test, as directed by the Domestic Nuclear Detection Office (DNDO). For a walk-through, the experiment was either setup or reviewed for setup; for a test, the N42.34-D6 procedures were followed with some exceptions and comments noted. SRNL is not fully able to evaluate a RID against Sections 7 (Environmental), 8 (Electromagnetic), and 9 (Mechanical) of N42.34, so those portions of this validation were done in collaboration with Qualtest, Inc. in Orlando, Florida. The walk-throughs and tests of Sections 7, 8, and 9 were performed in Qualtest, Inc. facilities with SRNL providing radiological sources as necessary. Where applicable, assessment results and findings of the walk-throughs and tests were recorded on datasheets and a validation summary is provided. A general comment pertained to test requirements found in another standard and referenced in N42.34-D6. For example, step 1 of the test method in section 8.1.2 states “RF test set up information can be found in IEC 61000-4-3.” It is recommended that any information from other standards necessary for conducting the tests within N42.34 should be posted in N42.34 for simplicity and to prevent the user from having to peruse other documents. Another general comment, as noted by Qualtest, is that a tolerance reference is not listed for each test in sections 7-9. Overall, the N42.34-D6 was proven to be practicable, but areas for improvement and recommendations were identified for consideration prior to final ballot submittal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modifications and testing of a 4-95 Stirling engine for solar applications

The modifications and testing of a standard Stirling engine, required for connection to a 25 kW induction alternator, for use with a solar thermal parabolic dish electric module is described. Power was absorbed by a GE induction alternator connected to the utility grid. Also included are the results from recent testing of another solar engine at the DOE-Georgia Tech solar site. It was done in parallel with the testing at Edwards for the purpose of comparing performance of two solar-only receivers, which were based on the standard 4-95 involute heat exchanger.

Nelving, H. G.↗

Measurement of the Proton's Weak Charge at the Qweak Experiment

The Qweak experiment at Jefferson Laboratory measures the parity violating asymmetry of polarized electrons scattering from a proton target at very low momentum transfer. In the Standard Model, this asymmetry reveals the proton's coupling to the neutral vector current, the weak charge. This value, measured directly for the first time, will provide a precision test of the Standard Model and will constrain the possibility of relevant physics beyond the Standard Model. The planned precision will probe certain classes of new physics at the ~2 TeV scale. In order to challenge the precise predictions, the asymmetry will be measured with a 2.5 percent accuracy. To achieve such a precision, great care has to be taken on many aspects of the experiment. The very low momentum transfer reduces the hadronic effects to the asymmetry and must be determined to half of a percent accuracy. Beam stability is controlled and monitored constantly and background events are carefully studied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NEPP Processor Enclave: Testing Artificial Intelligence & Machine Learning

Computational device families are converging and multiple EEE components are required for a complete HPC subsystem. The components of this “processor enclave” are sensitive to radiation effects and therefore must be characterized for mission assurance. NEPP’s standardized approach to testing the Processor Enclave includes math, graphics, and AI and Machine Learning test vectors and device hardware capable of these applications.

Radiation testing↗

Uptakes of Cs and Sr on San Joaquin soil measured following ASTM method C1733

Series of tests were conducted following ASTM Standard Procedure C1733 to evaluate the repeatability of the test and the effects of several test parameters, including the solution-to-soil mass ratio, test duration, pH, and the concentrations of contaminants in the solution. This standard procedure is recommended for measuring the distribution coefficient (K d ) of a contaminant in a specific soil/groundwater system. One objective of the current tests was to identify experimental conditions that can be used in future interlaboratory studies to determine the reproducibility of the test method. This includes the recommendation of a standard soil, the range of contaminant concentrations and solution matrix, and various test parameters. Quantifying the uncertainty in the distribution coefficient that can be attributed to the test procedure itself allows the differences in measured values to be associated with differences in the natural systems being studied.

54 ENVIRONMENTAL SCIENCES↗

Mechanical Behavior of MinK and FiberFrax Board Insulation Materials Under Battery Packaging Relevant Conditions

We present a new collection of data on the load-stress relaxation-unload behavior of MinK and FiberFrax Board (FF) insulation materials used as pellets in-line with thermal battery electrochemical stacks. Both materials were subjected to standard thermal preparations, and then tested at room temperature. Intermediate term stress relaxation tests are presented (order 104 minutes of relaxation) showing that FF relaxation is not significantly stress or deformation dependent, but MinK is moderately so. Moreover, stress-strain curves associated with specimen unloading, reloading, and unloading again are presented for both materials. FF and MinK are substantially different here. Acute material variability is observed though test conditions and material preparations are standardized. A modeling approach is presented to empirically estimate the amount of stress relaxation at room temperature, and from this state, represent the unloading stress-strain behavior of both materials. This effort provides a complete framework for representing (in an engineering sense) both materials in thermal battery performance simulations.

36 MATERIALS SCIENCE↗

Magnetic Test Performance Capabilities at the Goddard Space Flight Center as Applied to the Global Geospace Science Initiative

Goddard Space Flight Center's (GSFC) Spacecraft Magnetic Test Facility (SMTF) is a historic test facility that has set the standard for all subsequent magnetic test facilities. The SMTF was constructed in the early 1960's for the purpose of simulating geomagnetic and interplanetary magnetic fields. Additionally, the facility provides the capability for measuring spacecraft generated magnetic fields as well as calibrating magnetic attitude control systems and science magnetometers. The SMTF was designed for large, spacecraft level tests and is currently the second largest spherical coil system in the world. The SMTF is a three-axis Braunbek system composed of four coils on each of three orthogonal axes. The largest coils are 12.7 meters (41.6 feet) in diameter. The three-axis Braunbek configuration provides a highly uniform cancellation of the geomagnetic field over the central 1.8 meter (6 foot) diameter primary test volume. Cancellation of the local geomagnetic field is to within +/-0.2 nanotesla with a uniformity of up to 0.001% within the 1.8 meter (6 foot) diameter primary test volume. Artificial magnetic field vectors from 0-60,000 nanotesla can be generated along any axis with a 0.1 nanotesla resolution. Oscillating or rotating field vectors can also be produced about any axis with a frequency of up to 100 radians/second. Since becoming fully operational in July of 1967, the SMTF has been the site of numerous spacecraft magnetics tests. Spacecraft tested at the SMTF include: the Solar Maximum Mission (SMM), Magsat, LANDSAT-D, the Fast Aurora] Snapshot (FAST) Explorer and the Sub-millimeter-Wave-Astronomy Satellite (SWAS) among others. This paper describes the methodology and sequencing used for the Global Geospace Science (GGS) initiative magnetic testing program in the Goddard Space Flight Center's SMTF. The GGS initiative provides an exemplary model of a strict and comprehensive magnetic control program.

Mitchell, Darryl R.↗

Method and Apparatus for Testing Microwave Devices and Circuits in a Controlled Environment

A test system is disclosed that enables the testing of microwave components in a controlled environment without disturbing that environment. The system includes a test fixture which holds the calibration standards and the component being tested, and environmental control chamber, and a microwave switching system. The system provides a coaxial connection to microwave testing equipment, such as an automatic network analyzer (ANA) and facilitates both calibration and testing while maintaining environmental integrity.

Miranda, Felix A.↗

Acoustic Test Results of Melamine Foam with Application to Payload Fairing Acoustic Attenuation Systems

A spacecraft at launch is subjected to a harsh acoustic and vibration environment resulting from the passage of acoustic energy, created during the liftoff of a launch vehicle, through the vehicle's payload fairing. In order to ensure the mission success of the spacecraft it is often necessary to reduce the resulting internal acoustic sound pressure levels through the usage of acoustic attenuation systems. Melamine foam, lining the interior walls of the payload fairing, is often utilized as the main component of such a system. In order to better understand the acoustic properties of melamine foam, with the goal of developing improved acoustic attenuation systems, NASA has recently performed panel level testing on numerous configurations of melamine foam acoustic treatments at the Riverbank Acoustical Laboratory. Parameters assessed included the foam's thickness and density, as well as the effects of a top outer cover sheet material and mass barriers embedded within the foam. This testing followed the ASTM C423 standard for absorption and the ASTM E90 standard for transmission loss. The acoustic test data obtained and subsequent conclusions are the subjects of this paper.

Acoustic Foam↗

Refine your search to explore more results.