Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “techniques: image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

TU-EF-204-02: Hiigh Quality and Sub-MSv Cerebral CT Perfusion Imaging

Purpose: CT Perfusion (CTP) imaging is of great importance in acute ischemic stroke management due to its potential to detect hypoperfused yet salvageable tissue and distinguish it from definitely unsalvageable tissue. However, current CTP imaging suffers from poor image quality and high radiation dose (up to 5 mSv). The purpose of this work was to demonstrate that technical innovations such as Prior Image Constrained Compressed Sensing (PICCS) have the potential to address these challenges and achieve high quality and sub-mSv CTP imaging. Methods: (1) A spatial-temporal 4D cascaded system model was developed to indentify the bottlenecks in the current CTP technology; (2) A task-based framework was developed to optimize the CTP system parameters; (3) Guided by (1) and (2), PICCS was customized for the reconstruction of CTP source images. Digital anthropomorphic perfusion phantoms, animal studies, and preliminary human subject studies were used to validate and evaluate the potentials of using these innovations to advance the CTP technology. Results: The 4D cascaded model was validated in both phantom and canine stroke models. Based upon this cascaded model, it has been discovered that, as long as the spatial resolution and noise properties of the 4D source CT images are given, the 3D MTF and NPS of the final CTP maps can be analytically derived for a given set of processing methods and parameters. The cascaded model analysis also identified that the most critical technical factor in CTP is how to acquire and reconstruct high quality source images; it has very little to do with the denoising techniques often used after parametric perfusion calculations. This explained why PICCS resulted in a five-fold dose reduction or substantial improvement in image quality. Conclusion: Technical innovations generated promising results towards achieving high quality and sub-mSv CTP imaging for reliable and safe assessment of acute ischemic strokes. K. Li, K. Niu, Y. Wu: Nothing to disclose. G.-H. Chen: Research funded, GE Healthcare; Research funded, Siemens AX.

60 APPLIED LIFE SCIENCES↗

Monovision techniques for telerobots

The primary task of the vision sensor in a telerobotic system is to provide information about the position of the system's effector relative to objects of interest in its environment. The subtasks required to perform the primary task include image segmentation, object recognition, and object location and orientation in some coordinate system. The accomplishment of the vision task requires the appropriate processing tools and the system methodology to effectively apply the tools to the subtasks. This paper describes the functional structure of the telerobotic vision system used in the Langley Research Center's (LaRC) Intelligent Systems Research Laboratory (ISRL) and discusses two monovision techniques for accomplishing the vision subtasks.

Goode, Plesent W.↗

Parametric Analysis and Modeling for the Porosity Prediction in Suspension Plasma-Sprayed Coatings

The porous architecture of suspension plasma-sprayed coatings has a significant influence on the coating performances and thus should be properly designed for the intended applications. In this study, YSZ coatings were manufactured by suspension plasma spray (SPS), and a parametric study was performed with five different process parameters: suspension mass load, original powder particle size, substrate surface topology, spray distance, and spray step. Afterward, the porosity of the as-prepared coatings was investigated by imaging and x-ray transmission technique. A multivariate analysis on the collected experimental data was carried out. We report the results indicated that: (1) The total porosity of SPS coatings increases with the decrease in suspension mass load, while it shows the opposite trend by decreasing the spray distance, original powder particle size, substrate roughness, and spray step; (2) The main factor affecting coating total porosity is spray distance. Finally, a predictive model for coating total porosity was developed and was verified by experiments. Control of total porosity by using the predictive model was presented and explained as well.

47 OTHER INSTRUMENTATION↗

SPECKLE NOISE SUBTRACTION AND SUPPRESSION WITH ADAPTIVE OPTICS CORONAGRAPHIC IMAGING

Future ground-based direct imaging of exoplanets depends critically on high-contrast coronagraph and wave-front manipulation. A coronagraph is designed to remove most of the unaberrated starlight. Because of the wave-front error, which is inherit from the atmospheric turbulence from ground observations, a coronagraph cannot deliver its theoretical performance, and speckle noise will limit the high-contrast imaging performance. Recently, extreme adaptive optics, which can deliver an extremely high Strehl ratio, is being developed for such a challenging mission. In this publication, we show that barely taking a long-exposure image does not provide much gain for coronagraphic imaging with adaptive optics. We further discuss a speckle subtraction and suppression technique that fully takes advantage of the high contrast provided by the coronagraph, as well as the wave front corrected by the adaptive optics. This technique works well for coronagraphic imaging with conventional adaptive optics with a moderate Strehl ratio, as well as for extreme adaptive optics with a high Strehl ratio. We show how to substrate and suppress speckle noise efficiently up to the third order, which is critical for future ground-based high-contrast imaging. Numerical simulations are conducted to fully demonstrate this technique.

79 ASTRONOMY AND ASTROPHYSICS↗

A Two-Tier Convolutional Neural Network for Combined Detection and Segmentation in Biological Imagery

Deep learning techniques have been useful for modern microscopy imaging techniques to further study and analyze biological structures and organs. Convolutional neural networks (CNN) have improved 2D object detection, localization, and segmentation. For imagery containing biological structures with depth, it is especially desirable to perform these tasks in 3D. Traditionally, performing these tasks simultaneously in 3D has proven to be computationally expensive. Currently available methodologies thus largely work to segment 3D objects from 2D images (without context from captured 3D volumes). In this work, we present a novel approach to perform fast and accurate localization, detection, and segmentation of volumes containing cells. Specifically, in our method, we modify and tune two state-of-the-art CNNs, namely 2D YOLOv2 and 3D U-Net, and combine them with a new fusion and image processing algorithms. Annotated volumes in this space are limited, and we have created synthetic data that mimics actual structures for training and testing our proposed approach. Promising results on this test data demonstrate the value of the technique and offers a methodology for 3D cell analysis in real microscopy imagery.

Ziabari, Amir↗

Structural analysis techniqes for remote sensing

The structural analysis of remotely sensed imagery is defined and basic techniques for implementing the process are described. Structural analysis uses knowledge of the properties of an entity, its parts and their relationships, and the relationships in which it participates at a higher level to locate and recognize objects in a visual scene. The representation of structural knowledge, the development of algorithms for using the knowledge to help analyze an image, and techniques for storage and retrieval of relational models are addressed.

Shapiro, L. G.↗

Principal components technique analysis for vegetation and land use discrimination

Automatic pre-processing technique called Principal Components (PRINCO) in analyzing LANDSAT digitized data, for land use and vegetation cover, on the Brazilian cerrados was evaluated. The chosen pilot area, 223/67 of MSS/LANDSAT 3, was classified on a GE Image-100 System, through a maximum-likehood algorithm (MAXVER). The same procedure was applied to the PRINCO treated image. PRINCO consists of a linear transformation performed on the original bands, in order to eliminate the information redundancy of the LANDSAT channels. After PRINCO only two channels were used thus reducing computer effort. The original channels and the PRINCO channels grey levels for the five identified classes (grassland, "cerrado", burned areas, anthropic areas, and gallery forest) were obtained through the MAXVER algorithm. This algorithm also presented the average performance for both cases. In order to evaluate the results, the Jeffreys-Matusita distance (JM-distance) between classes was computed. The classification matrix, obtained through MAXVER, after a PRINCO pre-processing, showed approximately the same average performance in the classes separability.

Parada, N. D. J.↗

Studies on image compression and image reconstruction

During this six month period our works concentrated on three, somewhat different areas. We looked at and developed a number of error concealment schemes for use in a variety of video coding environments. This work is described in an accompanying (draft) Masters thesis. In the thesis we describe application of this techniques to the MPEG video coding scheme. We felt that the unique frame ordering approach used in the MPEG scheme would be a challenge to any error concealment/error recovery technique. We continued with our work in the vector quantization area. We have also developed a new type of vector quantizer, which we call a scan predictive vector quantization. The scan predictive VQ was tested on data processed at Goddard to approximate Landsat 7 HRMSI resolution and compared favorably with existing VQ techniques. A paper describing this work is included. The third area is concerned more with reconstruction than compression. While there is a variety of efficient lossless image compression schemes, they all have a common property that they use past data to encode future data. This is done either via taking differences, context modeling, or by building dictionaries. When encoding large images, this common property becomes a common flaw. When the user wishes to decode just a portion of the image, the requirement that the past history be available forces the decoding of a significantly larger portion of the image than desired by the user. Even with intelligent partitioning of the image dataset, the number of pixels decoded may be four times the number of pixels requested. We have developed an adaptive scanning strategy which can be used with any lossless compression scheme and which lowers the additional number of pixels to be decoded to about 7 percent of the number of pixels requested! A paper describing these results is included.

Sayood, Khalid↗

Multimodal Imaging of Autofluorescent Sites Reveals Varied Chemical Speciation in SSZ-13 Crystals

In this report a multimodal imaging study of chabazite is used to analyse emissive deposits. A notable difference is seen in the morphology of agglomerated surface deposits and larger subsurface deposits. Comparison of the distribution of organic residue throughout the crystal volume and XRF mapping is demonstrating that a fluorescence-based technique can also be used to indirectly comment on the compositional chemistry of the inorganic framework. A multimodal imaging study of chabazite is used to show the distribution of and discriminate between different emissive deposits arising as a result of the detemplation process. Confocal imaging, 3D fluorescence lifetime imaging, 3D multispectral fluorescence imaging, and Raman mapping are used to show three different types of emissive behaviours each characterised by different spatial distributions, trends in lifetime, spectral signals, and Raman signatures. A notable difference is seen in the morphology of agglomerated surface deposits and larger subsurface deposits, which experience lifetime augmentation due to spatial confinement. The distribution of organic residue throughout the crystal volume is comparable to XRF mapping that shows Si enrichment on the outer edges and higher Al content through the centre, demonstrating that a fluorescence-based technique can also be used to indirectly comment on the compositional chemistry of the inorganic framework.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and evaluation of a portable CZT coded aperture gamma-camera

We present the design and the evaluation of a CdZnTe (CZT) based gamma camera using a coded aperture mask. This camera, based on a 8 cm{sup 3} detection module, is small enough to be portable and battery-powered (4 kg weight and 4 W power dissipation). As the detector has spectral capabilities, the gamma camera allows isotope identification and colored imaging, by affecting one color channel to each identified isotope. As all data processing is done at real time, the user can directly observe the outcome of an acquisition and can immediately react to what he sees. We first present the architecture of the system, how the detector works, and its performances. After, we focus on the imaging technique used and its strengths and limitations. Finally, results concerning sensitivity, spatial resolution, field of view and multi-isotope imaging are shown and discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-calibration of a cone-beam micro-CT system

Use of cone-beam computed tomography (CBCT) is becoming more frequent. For proper reconstruction, the geometry of the CBCT systems must be known. While the system can be designed to reduce errors in the geometry, calibration measurements must still be performed and corrections applied. Investigators have proposed techniques using calibration objects for system calibration. In this study, the authors present methods to calibrate a rotary-stage CB micro-CT (CB{mu}CT) system using only the images acquired of the object to be reconstructed, i.e., without the use of calibration objects. Projection images are acquired using a CB{mu}CT system constructed in the authors' laboratories. Dark- and flat-field corrections are performed. Exposure variations are detected and quantified using analysis of image regions with an unobstructed view of the x-ray source. Translations that occur during the acquisition in the horizontal direction are detected, quantified, and corrected based on sinogram analysis. The axis of rotation is determined using registration of antiposed projection images. These techniques were evaluated using data obtained with calibration objects and phantoms. The physical geometric axis of rotation is determined and aligned with the rotational axis (assumed to be the center of the detector plane) used in the reconstruction process. The parameters describing this axis agree to within 0.1 mm and 0.3 deg with those determined using other techniques. Blurring due to residual calibration errors has a point-spread function in the reconstructed planes with a full-width-at-half-maximum of less than 125 {mu}m in a tangential direction and essentially zero in the radial direction for the rotating object. The authors have used this approach on over 100 acquisitions over the past 2 years and have regularly obtained high-quality reconstructions, i.e., without artifacts and no detectable blurring of the reconstructed objects. This self-calibrating approach not only obviates calibration runs, but it also provides quality control data for each data set.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A large expert-curated cryo-EM image dataset for machine learning protein particle picking

Cryo-electron microscopy (cryo-EM) is a powerful technique for determining the structures of biological macromolecular complexes. Picking single-protein particles from cryo-EM micrographs is a crucial step in reconstructing protein structures. However, the widely used template-based particle picking process is labor-intensive and time-consuming. Though machine learning and artificial intelligence (AI) based particle picking can potentially automate the process, its development is hindered by lack of large, high-quality labelled training data. To address this bottleneck, we present CryoPPP, a large, diverse, expert-curated cryo-EM image dataset for protein particle picking and analysis. It consists of labelled cryo-EM micrographs (images) of 34 representative protein datasets selected from the Electron Microscopy Public Image Archive (EMPIAR). The dataset is 2.6 terabytes and includes 9,893 high-resolution micrographs with labelled protein particle coordinates. The labelling process was rigorously validated through 2D particle class validation and 3D density map validation with the gold standard. The dataset is expected to greatly facilitate the development of both AI and classical methods for automated cryo-EM protein particle picking.

42 ENGINEERING↗

Care, feeding, and use of charge-coupled device /CCD/ imagers at Palomar observatory

The paper describes the optical, mechanical, and electronic properties of the TI and RCA CCDs which have been applied to two-dimensional photometry and spectroscopy at Palomar. The drive, processing, and recording techniques are also discussed, and consideration is given to a focal conversion optical system, the Prime Focus Universal Extragalactic Instrument (PFUEI), which is used to more optimally match the Hale 5 meter plate scale. Calibration and data analysis are also examined.

Gunn, J. E.↗

Fourier analysis and synthesis tomography.

Most far-field optical imaging systems rely on a lens and spatially-resolved detection to probe distinct locations on the object. We describe and demonstrate a novel high-speed wide-field approach to imaging that instead measures the complex spatial Fourier transform of the object by detecting its spatially-integrated response to dynamic acousto-optically synthesized structured illumination. Tomographic filtered backprojection is applied to reconstruct the object in two or three dimensions. This technique decouples depth-of-field and working-distance from resolution, in contrast to conventional imaging, and can be used to image biological and synthetic structures in fluoresced or scattered light employing coherent or broadband illumination. We discuss the electronically programmable transfer function of the optical system and its implications for imaging dynamic processes. Finally, we present for the first time two-dimensional high-resolution image reconstructions demonstrating a three-orders-of-magnitude improvement in depth-of-field over conventional lens-based microscopy.

47 OTHER INSTRUMENTATION↗

A Model-Based Approach for the Measurement of Eye Movements Using Image Processing

This paper describes a video eye-tracking algorithm which searches for the best fit of the pupil modeled as a circular disk. The algorithm is robust to common image artifacts such as the droopy eyelids and light reflections while maintaining the measurement resolution available by the centroid algorithm. The presented algorithm is used to derive the pupil size and center coordinates, and can be combined with iris-tracking techniques to measure ocular torsion. A comparison search method of pupil candidates using pixel coordinate reference lookup tables optimizes the processing requirements for a least square fit of the circular disk model. This paper includes quantitative analyses and simulation results for the resolution and the robustness of the algorithm. The algorithm presented in this paper provides a platform for a noninvasive, multidimensional eye measurement system which can be used for clinical and research applications requiring the precise recording of eye movements in three-dimensional space.

Sung, Kwangjae↗

Developing stereo image based robot control system

Application of image processing is developed in various field and purposes. In the last decade, image based system increase rapidly with the increasing of hardware and microprocessor performance. Many fields of science and technology were used this methods especially in medicine and instrumentation. New technique on stereovision to give a 3-dimension image or movie is very interesting, but not many applications in control system. Stereo image has pixel disparity information that is not existed in single image. In this research, we proposed a new method in wheel robot control system using stereovision. The result shows robot automatically moves based on stereovision captures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stochastic nature of magnetic processes studied by full-field soft X-ray microscopy

In nanomagnetism, one of the crucial scientific questions is whether magnetic behaviors are deterministic or stochastic on a nanoscale. Apart from the exciting physical issue, this question is also of paramount highest relevance for using magnetic materials in a wealth of technological applications such as magnetic storage and sensor devices. In the past, the research on the stochasticity of a magnetic process has been mainly done by macroscopic measurements, which only offer ensemble-averaged information. To give more accurate answer for the question and to fully understand related underlying physics, the direct observation of statistical behaviors in magnetic structures and magnetic phenomena utilizing advanced characterization techniques is highly required. One of the ideal tools for such study is a full-field soft X-ray microscope since it enables imaging of magnetic structures on the large field of view within a few seconds. Here in this paper, we review the stochastic behaviors of various magnetic processes including magnetization reversal process in thin films, magnetic domain wall motions in nanowires, and magnetic vortex formations in nanodisks studied by full-field soft X-ray microscopy. The origin triggering the stochastic nature witnessed in each magnetic process and the way to control the intrinsic nature are also discussed.

36 MATERIALS SCIENCE↗

Optical and gas-sensing properties, and electronic structure of the mixed-phase CaCu{sub 3}Ti{sub 4}O{sub 12}/CaTiO{sub 3} composites

Highlights: • CCTO/CTO composites were synthesized by a solid-state reaction using various milling durations. • These composites have a broad PL emission band located at 450 nm. • CCTO/CTO material was deposited onto an alumina substrate using a screen-printing technique, and hence, could be structured for gas-sensing applications. • Our theoretical findings may further elucidate the electronic structure associated with the interfacial band alignment (type I-straddling gap). - Abstract: Combined experimental and theoretical investigations were conducted on the electronic structure, as well as the optical and gas-sensing properties of mixed-phase CaCu{sub 3}Ti{sub 4}O{sub 12}/CaTiO{sub 3} (CCTO/CTO) composites, which were synthesized by a solid-state reaction using various milling durations. Our results revealed that these CCTO/CTO composites have a broad photoluminescence (PL) emission band located at 450 nm, which is strongly influenced by the milling process duration. Scanning electron microscopy images confirmed that the use of longer milling durations favored the formation of pores and increased the active surface area of the CCTO/CTO thick films. The thick films were prepared using the screen-printing technique, and hence, could be structured for gas-sensing applications. Our theoretical findings may further elucidate the electronic structure associated with the interfacial band alignment (type I-straddling gap) of the CCTO/CTO composite systems.

36 MATERIALS SCIENCE↗

Refine your search to explore more results.