Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Kepler Mission Development Challenges and Early Results

Kepler is NASA s first mission capable of detecting Earth-size planets orbiting in the habitable zone of stars other than the Sun. Kepler comprises a space telescope designed to continuously monitor the brightnesses of more than 100,000 target stars, and a ground segment to analyze the measured stellar light curves and detect the signatures of orbiting planets. In order to detect Earth-size planets orbiting Sun-like stars Kepler was designed to provide unprecedented photometric sensitivity and stability. This paper addresses some of the technical challenges encountered during the development of the Kepler mission and the measures taken to overcome them. Early scientific results are summarized.

exo-planets↗

Kepler Mission Development Challenges and Early Results

Kepler is NASA`s first mission capable of detecting Earth-size planets orbiting in the habitable zone of stars other than the sun. Kepler comprises a space telescope designed to continuously monitor the brightnesses of more than 100,000 target stars, and a ground segment to analyze the measured stellar light curves and detect the signatures of orbiting planets. In order to detect Earth-size planets orbiting Sun-like stars Kepler was designed to provide unprecedented photometric sensitivity and stability. This paper addresses some of the technical challenges encountered during the development of the Kepler mission and the measures taken to overcome them. Early scientific results are summarized.

habitable zones↗

DETECTABILITY OF EXOPLANETS IN THE {beta} PIC MOVING GROUP WITH THE GEMINI PLANET IMAGER

We model the detectability of exoplanets around stars in the {beta} Pic Moving Group (BPMG) using the Gemini Planet Imager (GPI), a coronagraphic instrument designed to detect companions by imaging. Members of the BPMG are considered promising targets for exoplanet searches because of their youth ({approx}12 Myr) and proximity (median distance {approx}35 pc). We wrote a modeling procedure to generate hypothetical companions of given mass, age, eccentricity, and semi-major axis, and place them around BPMG members that fall within the V-band range of the GPI. We count companions lying within the GPI's field of view and H-band fluxes that have a host-companion flux ratio placing them within its sensitivity as possible detections. The fraction of companions that could be detected depends on their brightness at 12 Myr, and hence formation mechanism, and on their distribution of semi-major axes. We used brightness models for formation by disk instability and core-accretion. We considered the two extreme cases of the semi-major axis distribution-the log-normal distribution of the nearby F- and G-type stars and a power-law distribution indicated by the exoplanets detected by the radial velocity technique. We find that the GPI could detect exoplanets of all the F and G spectral type stars in the BPMG sample with a probability that depends on the brightness model and semi-major axis distribution. At spectral type K-M1, exoplanet detectability depends on brightness and hence distance of the host star. GPI will be able to detect the companions of M stars later than M1 only if they are closer than 10 pc. Of the four A stars in the BPMG sample, only one has a V-band brightness in the range of GPI; the others are too bright.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-113: Dose Distribution Using Respiratory Signals and Machine Parameters During Treatment

Purpose: Volumetric modulated arc therapy (VMAT) is a rotational intensity-modulated radiotherapy (IMRT) technique capable of acquiring projection images during treatment. Treatment plans for lung tumors using stereotactic body radiotherapy (SBRT) are calculated with planning computed tomography (CT) images only exhale phase. Purpose of this study is to evaluate dose distribution by reconstructing from only the data such as respiratory signals and machine parameters acquired during treatment. Methods: Phantom and three patients with lung tumor underwent CT scans for treatment planning. They were treated by VMAT while acquiring projection images to derive their respiratory signals and machine parameters including positions of multi leaf collimators, dose rates and integrated monitor units. The respiratory signals were divided into 4 and 10 phases and machine parameters were correlated with the divided respiratory signals based on the gantry angle. Dose distributions of each respiratory phase were calculated from plans which were reconstructed from the respiratory signals and the machine parameters during treatment. The doses at isocenter, maximum point and the centroid of target were evaluated. Results and Discussion: Dose distributions during treatment were calculated using the machine parameters and the respiratory signals detected from projection images. Maximum dose difference between plan and in treatment distribution was −1.8±0.4% at centroid of target and dose differences of evaluated points between 4 and 10 phases were no significant. Conclusion: The present method successfully evaluated dose distribution using respiratory signals and machine parameters during treatment. This method is feasible to verify the actual dose for moving target.

60 APPLIED LIFE SCIENCES↗

Motion-sensitive optical correlator using a VanderLugt correlator

A new type of optical correlator is presented. The correlator performs motion detection or background clutter suppression and correlation simultaneously in a single photorefractive crystal. Additionally, the device is useful for moving target identification and tracking and for stationary clutter rejection. The correlation is of the VanderLugt type, and the motion detection or background clutter suppression is based on the erasing property of photorefractive crystals.

Liu, Tsuen-Hsi↗

The Electromagnetic Counterpart of the Binary Neutron Star Merger LIGO/Virgo GW170817. VI. Radio Constraints on a Relativistic Jet and Predictions for Late-time Emission from the Kilonova Ejecta

We present Very Large Array (VLA) and Atacama Large Millimeter/submillimeter Array (ALMA) radio observations of GW170817, the first Laser Interferometer Gravitational-wave Observatory (LIGO)/Virgo gravitational wave (GW) event from a binary neutron star merger and the first GW event with an electromagnetic (EM) counterpart. Our data include the first observations following the discovery of the optical transient at both the centimeter (13.7 hr post-merger) and millimeter (2.41 days post-merger) bands. We detect faint emission at 6 GHz at 19.47 and 39.23 days after the merger, but not in an earlier observation at 2.46 days. We do not detect cm/mm emission at the position of the optical counterpart at frequencies of 10–97.5 GHz at times ranging from 0.6 to 30 days post-merger, ruling out an on-axis short gamma-ray burst (SGRB) for energies ≳10{sup 48} erg. For fiducial SGRB parameters, our limits require an observer viewer angle of ≳20°. The radio and X-ray data can be jointly explained as the afterglow emission from an SGRB with a jet energy of ∼10{sup 49}--10{sup 50} erg that exploded in a uniform density environment with n∼10{sup −4}--10{sup −2} cm{sup −3}, viewed at an angle of ∼20°–40° from the jet axis. Using the results of our light curve and spectral modeling, in conjunction with the inference of the circumbinary density, we predict the emergence of late-time radio emission from the deceleration of the kilonova (KN) ejecta on a timescale of ∼5–10 years that will remain detectable for decades with next-generation radio facilities, making GW170817 a compelling target for long-term radio monitoring.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of Technology for Compact Coherent Lidar

In view of the recent advances in the area of solid state and semiconductor lasers has created new possibilities for the development of compact and reliable coherent lidars for a wide range of applications. These applications include: Automated Rendezvous and Capture, wind shear and clear air turbulence detection, aircraft wake vortex detection, and automobile collision avoidance. The work performed by the UAH personnel under this Delivery Order, concentrated on design and analyses of a compact coherent lidar system capable of measuring range and velocity of hard targets, and providing air mass velocity data. The following is the scope of this work. a. Investigate various laser sources and optical signal detection configurations in support of a compact and lightweight coherent laser radar to be developed for precision range and velocity measurements of hard and fuzzy targets. Through interaction with MSFC engineers, the most suitable laser source and signal detection technique that can provide a reliable compact and lightweight laser radar design will be selected. b. Analyze and specify the coherent laser radar system configuration and assist with its optical and electronic design efforts. Develop a system design including its optical layout design. Specify all optical components and provide the general requirements of the electronic subsystems including laser beam modulator and demodulator drivers, detector electronic interface, and the signal processor. c. Perform a thorough performance analysis to predict the system measurement range and accuracy. This analysis will utilize various coherent laser radar sensitivity formulations and different target models.

Amzajerdian, Farzin↗

Use of Longitudinal Serum Analysis and Machine Learning to Develop a Classifier for Cancer Early Detection

Early detection of solid tumors through a simple screening process, such as the proteomic analysis of biofluids, has the potential to significantly alter the management and outcomes of cancers. The application of advanced targeted proteomics measurements and data analysis strategies to uniformly collected serum or plasma samples would enable longitudinal studies of cancer risk, progression, and response to therapy that have the potential to significantly reduce cancer burden in general. In this article, we describe a generalizable workflow combining robust, multiplexed targeted proteomics measurements applied to longitudinal samples from the Department of Defense Serum Repository with a Random Forest machine learning method for developing and initially evaluating the performance of candidate biomarker panels for early detection of cancers. The effectiveness of this approach was demonstrated in a cohort of 175 head and neck squamous cell carcinoma patients. The outlined protocols include methods for sample preparation, instrument analysis, and data analysis and interpretation using this workflow.

Longitudinal analysis, machine learning, cancer, e↗

ON THE COMPLEMENTARITY OF PULSAR TIMING AND SPACE LASER INTERFEROMETRY FOR THE INDIVIDUAL DETECTION OF SUPERMASSIVE BLACK HOLE BINARIES

Gravitational waves coming from supermassive black hole binaries (SMBHBs) are targeted by both the Pulsar Timing Array (PTA) and Space Laser Interferometry (SLI). The possibility of a single SMBHB being tracked first by PTA, through inspiral, and later by SLI, up to merger and ring-down, has been previously suggested. Although the bounding parameters are drawn by the current PTA or the upcoming Square Kilometer Array (SKA), and by the New Gravitational Observatory (NGO), derived from the Laser Interferometer Space Antenna (LISA), this paper also addresses sequential detection beyond specific project constraints. We consider PTA-SKA, which is sensitive from 10{sup -9} to p Multiplication-Sign 10{sup -7} Hz (p = 4, 8), and SLI, which operates from s Multiplication-Sign 10{sup -5} up to 1 Hz (s = 1, 3). An SMBHB in the range of 2 Multiplication-Sign 10{sup 8}-2 Multiplication-Sign 10{sup 9} M {sub Sun} (the masses are normalized to a (1 + z) factor, the redshift lying between z = 0.2 and z = 1.5) moves from the PTA-SKA to the SLI band over a period ranging from two months to fifty years. By combining three supermassive black hole (SMBH)-host relations with three accretion prescriptions, nine astrophysical scenarios are formed. They are then related to three levels of pulsar timing residuals (50, 5, 1 ns), generating 27 cases. For residuals of 1 ns, sequential detection probability will never be better than 4.7 Multiplication-Sign 10{sup -4} yr{sup -2} or 3.3 Multiplication-Sign 10{sup -6} yr{sup -2} (per year to merger and per year of survey), according to the best and worst astrophysical scenarios, respectively; put differently this means one sequential detection every 46 or 550 years for an equivalent maximum time to merger and duration of the survey. The chances of sequential detection are further reduced by increasing values of the s parameter (they vanish for s = 10) and of the SLI noise, and by decreasing values of the remnant spin. The spread in the predictions diminishes when timing precision is improved or the SLI low-frequency cutoff is lowered. So while transit times and the SLI signal-to-noise ratio (S/N) may be adequate, the likelihood of sequential detection is severely hampered by the current estimates on the number-just a handful-of individual inspirals observable by PTA-SKA, and to a lesser extent by the wide gap between the pulsar timing and space interferometry bands, and by the severe requirements on pulsar timing residuals. Optimization of future operational scenarios for SKA and SLI is briefly dealt with, since a detection of even a single event would be of paramount importance for the understanding of SMBHBs and of the astrophysical processes connected to their formation and evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Hubble Asteroid Hunter

Context: The Hubble Space Telescope (HST) archives constitute a rich dataset of high-resolution images to mine for strong gravitational lenses. While many HST programmes specifically target strong lenses, they can also be present by coincidence in other HST observations. Aims: Our aim is to identify non-targeted strong gravitational lenses, without any prior selection on the lens properties, in almost two decades of images from the ESA HST archive (eHST). Methods: We used crowdsourcing on the Hubble Asteroid Hunter (HAH) citizen science project to identify strong lenses, along with asteroid trails, in publicly available large field-of-view HST images. We visually inspected 2354 objects tagged by citizen scientists as strong lenses to clean the sample and identify the genuine lenses. Results: We report the detection of 252 strong gravitational lens candidates, which were not the primary targets of the HST observations. A total of 198 of them are new, not previously reported by other studies, consisting of 45 A grades, 74 B grades and 79 C grades. The majority are galaxy-galaxy configurations. The newly detected lenses are, on average, 1.3 magnitudes fainter than previous HST searches. This sample of strong lenses with high-resolution HST imaging is ideal to follow up with spectroscopy for lens modelling and scientific analyses. Conclusions: This paper presents the unbiased search of lenses that enabled us to find a wide variety of lens configurations, including exotic lenses. We demonstrate the power of crowdsourcing in visually identifying strong lenses and the benefits of exploring large archival datasets. This study shows the potential of using crowdsourcing in combination with artificial intelligence for the detection and validation of strong lenses in future large-scale surveys such as ESA’s Euclid mission or in James Webb Space Telescope (JWST) archival images.

79 ASTRONOMY AND ASTROPHYSICS↗

E1 and E2 cross sections of the {sup 12}C({alpha},{gamma}){sup 16}O reaction at E{sub cm}{approx}1.4 Mev using pulsed {alpha} beams

We have installed a new system to measure the {gamma}-ray angular distribution of the {sup 12}C({alpha},{gamma}){sup 16}O reaction at the 3.2 MV Pelletron accelerator laboratory at Tokyo Institute of Technology to accurately determine the E1 and E2 cross sections. In this experiment, we used high efficiency anti-Compton NaI(T1) spectrometers to detect a {gamma}-ray from the reaction with a large S/N ratio, intense pulsed {alpha} beams to discriminate true events from neutron induced background with a time-of-flight (TOF) method, and the monitoring system of target thickness. We succeeded in removing a background due to neutrons and could clearly detect the {gamma}-ray from the {sup 12}C({alpha},{gamma}){sup l6}O reaction with high statistics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preconcentrator with high volume chiller for high vapor pressure particle detection

Apparatus and method for collecting particles of both high and low vapor pressure target materials entrained in a large volume sample gas stream. Large volume active cooling provides a cold air supply which is mixed with the sample gas stream to reduce the vapor pressure of the particles. In embodiments, a chiller cools air from ambient conditions to 0-15.degree. C. with the volumetric flow rate of the cold air supply being at least equal to the volumetric flow rate of the sample gas stream. In further embodiments an adsorption media is heated in at least two stages, a first of which is below a threshold temperature at which decomposition products of the high vapor pressure particle are generated.

47 OTHER INSTRUMENTATION↗

Efficient track-before detect algorithm with minimal prior knowledge

Apparatus, system and method for tracking an image target in a system, wherein a system receives an image comprising a plurality of pixels. The received image is processed via a plurality of different recursive motion model kernels in parallel to provide a plurality of kernel outputs, wherein each of the motion model kernels may include a respective pixel mask. Per-pixel energy is estimated of at least some of the plurality of kernel outputs. Velocity of at least one of the image pixels may also be estimated by generating a directional energy vector for each motion model kernel. The per-pixel energy and velocity estimates are fused to produce a fused estimate representing at least some of the motion model kernels for the image.

42 ENGINEERING↗

RESULTS FOR THE THIRD QUARTER 2009 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

This report details the chemical and radionuclide contaminant results for the characterization of the 2009 Third Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Liquid Waste Operations (LWO) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. Recently, a review of the radionuclide inventory in Saltstone Vaults 1 and 4 identified several additional radionuclides, not currently in the WAC, which require quantification ({sup 40}K, {sup 108m}Ag, {sup 133}Ba, {sup 207}Bi, {sup 227}Ac, {sup 228}Ra, {sup 228}Th, {sup 231}Pa, {sup 247}Cm, {sup 249}Cf, {sup 251}Cf). In addition, several of the radionuclides previously reported with minimum detection limits below the requirements listed in the WAC required analysis with reduced detection limits to support future inventory reporting requirements ({sup 22}Na, {sup 26}Al, {sup 59}Ni, {sup 94}Nb, {sup 106}Ru, {sup 144}Ce, {sup 152}Eu, {sup 155}Eu, {sup 226}Ra). This added scope was formally requested in a revision to the standing Technical Task Request for CY2009 Saltstone support and is further discussed in several supporting documents. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants are less than their respective WAC targets or limits unless noted in this section. (2) The reported detection limits for {sup 59}Ni, {sup 94}Nb, {sup 247}Cm, and {sup 249}Cf are above the limits requested by LWO; however, they are below the achievable limits established by Analytical Development (AD). (3) The reported detection limit of isopropanol is lower than its WAC Limit for accident analysis in Appendix 8.1, but higher than its WAC concentration given in Table 4 for vault flammability. The higher detection limit is expected based on current analytical capabilities and is documented in the Task Technical and Quality Assurance Plan (TTQAP). (4) The reported detection limit for Isopar L is lower than its WAC limit for accident analysis in Appendix 8.1 but higher than its WAC concentration given in Table 3 in reference to vault flammability. (5) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the GC/MS; however, the results may not accurately represent the concentrations of these analytes in the Tank 50 sample received by SRNL.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An experimental study of energy dependence of saturation thickness of multiply scattered gamma rays in binary alloys

The present measurements are carried out to investigate the multiple scattering of 662 keV gamma photons emerging from targets of binary alloys (brass and soldering material). The scattered photons are detected by 51 mm × 51 mm NaI(Tl) scintillation detector whose response unscrambling converting the observed pulse–height distribution to a true photon energy spectrum, is obtained with the help of 10 × 10 inverse response matrix. The numbers of multiply scattered events, having same energy as in the singly scattered distribution, first increases with target thickness and then saturate. The application of response function of scintillation detector does not result in any change of measured saturation thickness. Monte Carlo calculation supports the present experimental results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Artemis II Inertial Sensor Failure & Abort Condition Study

Given Artemis II as the first crewed lunar mission in decades, significant effort is directed towards understanding Space Launch System (SLS) response to failures of the three inertial sensors: two Ring-Laser Gyro Assemblies (RGAs) and the Redundant Inertial Navigation Unit (RINU). Parametric studies identify Loss of Mission (LOM) or Loss of Crew (LOC) sensitive mission phases. Fault Detection & Isolation (FDI) algorithms’ thresholds’ performance is assessed with respect to detecting LOM or LOC causing sensor failures. Monte Carlo studies are performed targeting specific trajectory phases for insight into re-optimizing FDI thresholds and improving knowledge of SLS sensor failure response statistics.

SLS↗

Millimeter-wave Detections of Symbiotic Stars in SPT and ACT Data

We present the results of a joint targeted search of candidate symbiotic stars at millimeter wavelengths using the South Pole Telescope (SPT) and the Atacama Cosmology Telescope (ACT). Candidates are selected from the New Online Database of Symbiotic Variables, restricting to objects that are within either the SPT-3G or ACT~DR6 footprint, covering most of the southern hemisphere and up to a declination of $+20^\circ$. Forced photometry on the 828 candidate symbiotic star locations in SPT and ACT data results in 31 unique objects detected with more than a $3σ$ significance using two frequency bands: 18 confirmed and 13 suspected symbiotic stars. We provide the SPT and ACT 95/98, 150, and 220~GHz light curves, along with optical and infrared light curves from 2016--2026, as well as spectral energy distributions, physical parameters from the literature, and brief summaries regarding the nature of each individual object. Using Herschel SPIRE data from 2013, we place upper limits on millimeter flux for CN Cha near the beginning of the optical rise in its 2012/2013 nova, which suggests a strong variability and lag at millimeter wavelengths and results in a rare observance of a Galactic millimeter slow transient. In addition, we provide coadded thumbnails and light curves for the remaining 797 candidate symbiotic stars that did not pass our detection thresholds. Millimeter-wave emission from symbiotic stars is primarily a combination of free-free emission of the ionization region and optically thick blackbody emission of the cooler dust components of the system. When combined with contemporaneous multi-wavelength observations, millimeter-wave observations can be used to test binary models of symbiotic stars and provide insight on the geometry and physical properties of these systems.

Tandoi, C. [Illinois U., Urbana, Astron. Dept.] (O↗

The use of microarrays in microbial ecology

Microarrays have proven to be a useful and high-throughput method to provide targeted DNA sequence information for up to many thousands of specific genetic regions in a single test. A microarray consists of multiple DNA oligonucleotide probes that, under high stringency conditions, hybridize only to specific complementary nucleic acid sequences (targets). A fluorescent signal indicates the presence and, in many cases, the abundance of genetic regions of interest. In this chapter we will look at how microarrays are used in microbial ecology, especially with the recent increase in microbial community DNA sequence data. Of particular interest to microbial ecologists, phylogenetic microarrays are used for the analysis of phylotypes in a community and functional gene arrays are used for the analysis of functional genes, and, by inference, phylotypes in environmental samples. A phylogenetic microarray that has been developed by the Andersen laboratory, the PhyloChip, will be discussed as an example of a microarray that targets the known diversity within the 16S rRNA gene to determine microbial community composition. Using multiple, confirmatory probes to increase the confidence of detection and a mismatch probe for every perfect match probe to minimize the effect of cross-hybridization by non-target regions, the PhyloChip is able to simultaneously identify any of thousands of taxa present in an environmental sample. The PhyloChip is shown to reveal greater diversity within a community than rRNA gene sequencing due to the placement of the entire gene product on the microarray compared with the analysis of up to thousands of individual molecules by traditional sequencing methods. A functional gene array that has been developed by the Zhou laboratory, the GeoChip, will be discussed as an example of a microarray that dynamically identifies functional activities of multiple members within a community. The recent version of GeoChip contains more than 24,000 50mer oligonucleotide probes and covers more than 10,000 gene sequences in 150 gene categories involved in carbon, nitrogen, sulfur, and phosphorus cycling, metal resistance and reduction, and organic contaminant degradation. GeoChip can be used as a generic tool for microbial community analysis, and also link microbial community structure to ecosystem functioning. Examples of the application of both arrays in different environmental samples will be described in the two subsequent sections.

54 ENVIRONMENTAL SCIENCES↗

Refine your search to explore more results.