Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

High-Penetration PV Deployment in the Arizona Public Service System, Phase 1 Update: Preprint

In an effort to better understand the impacts of high penetrations of photovoltaic generators on distribution systems, Arizona Public Service and its partners have begun work on a multi-year project to develop the tools and knowledge base needed to safely and reliably integrate high penetrations of utility- and residential-scale photovoltaics (PV). Building upon the APS Community Power Project --Flagstaff Pilot, this project will analyze the impact of PV on a representative feeder in northeast Flagstaff. To quantify and catalog the effects of the estimated 1.3 MW of PV that will be installed on the feeder (both smaller units at homes as well as large, centrally located systems), high-speed weather and electrical data acquisition systems and digital 'smart' meters are being designed andinstalled to facilitate monitoring and to build and validate comprehensive, high-resolution models of the distribution system. These models will be used to analyze the impacts of the PV on distribution circuit protection systems (including anti-islanding), predict voltage regulation and phase balance issues, and develop volt/var control schemes. This paper continues from a paper presented at the2011 IEEE PVSC conference that introduces the project and describes some of the preliminary consideration, as well as project plans and early results. This paper gives a status update of the project and presents selected results from Phase 2 of the project. It discusses baseline feeder modeling, load allocation, data acquisition, utility-scale PV integration, preliminary model validation, andplans for future phases.

14 SOLAR ENERGY↗

Sensor enabled data-driven predictive analytics for modeling and control with high penetration of DERs in distribution systems

The electric power grid is undergoing a tremendous transformation due to the increasing penetration of renewable energy resources beginning with wind and more recently with the distributed energy resources (DERs) such as solar and battery storage. DERs have dramatically changed the role of the distribution systems in the overall power grid, and they are expected to contribute a significant portion of power generation in the future. If current trends for DERs continue, system operation and control will need to change dramatically for improved grid reliability and resiliency. As renewable resources increase in penetration, new and challenging operational, planning, and design problems are expected to emerge. Some of the key challenges that arise in the planning and operation of the future grid are: 1) Quantifying the impact of high DER penetration in distribution systems on bulk grid behavior over multiple time scales. 2) Identifying whether a particular DER configuration/settings have a large impact on the overall grid behavior. These challenges can be addressed in an offline manner using detailed T&D grid models and they can also be addressed in an online manner using sensor measurements. In particular, the advancement and planned growth in sensor technology in power grid over various voltage levels provide us with a unique opportunity to tackle these challenges from a data analytic perspective without needing detailed T&D grid models. A few questions that naturally arise when addressing the challenges from DERs using sensor data are: 1) How can we use limited sensor measurements to monitor & control voltage stability and small signal stability of the bulk system? 2) How can we ensure that the developed data analytic methods are robust to data availability and quality issues? 3) How can we compute the developed analytics in a scalable manner using streaming measurements? In this project, we addressed the aforementioned challenges arising from DERs and answered the questions raised above on how to effectively use the sensor measurements to enhance the reliability and performance of the electric grid. Thus, the overarching goal of this project is to develop effective reduced/representative system models from data that make the computational complexity sufficiently manageable so as to be useful to simulate, analyze, and even control complex non-linear power systems dynamics with large penetrations of DERs. In order to achieve the objective, the project team established a four-fold technical approach 1) Formulated a combined transmission-distribution co-simulation framework for data generation and validation, 2) Derived reduced/representative models of power systems based on data-driven methods for efficient computation and appropriate representation of system behavior, 3) Developed data driven characterization of power system behavior based on transfer operator theory, machine learning and optimization for model estimation, 4) Incorporated a scalable data management and processing architecture using distributed Kafka streaming applications that coordinate input data streams to the developed data analytics. The key accomplishments of the project are: 1) Development of a scalable multi-timescale T&D co-simulation framework (both for steady state and for dynamic co-simulation) using commercial solvers (PSSE and GridLAB-D). The steady-state T&D co-simulation interface is shared with our industry partner (PJM). 2) A structured reduced order dynamic model of distribution systems that can represent partial motor stalling along with a systematic procedure to derive the model parameters. 3) A PMU based online method to monitor, localize and mitigate fault-induced delayed voltage recovery using DER reactive support and load control in distribution systems. 4) Development of linear operator based robust methodologies for dynamic state estimation, uncertainty quantification, system identification and trajectory prediction for power system dynamics. 5) An adaptive damping control for utilizing wind energy resources to provide oscillation damping and system stability. 6) Implementation of Kafka-based framework for efficient processing of streaming data using Linux-based local virtual environment.

DER integration↗

Decentralized Voltage optimization Method for Distribution Networks with Distributed PVs

In order to solve the voltage violations caused by high penetration distributed photovoltaics (PVs), this paper proposes a decentralized voltage optimization method for distribution networks. Through the optimal dispatch of distributed PVs and reactive power resources, it realizes the voltage security and economic operation of distribution systems and facilitates the integration of massive distributed PVs. The proposed method is inspired by the idea of locational marginal price (LMP) and feasible cutting plane. It separates the optimization of boundary bus voltage and power flow in adjacent regions and uses the interaction of boundary variables’ marginal prices to obtain the optimal solution. The effectiveness and accuracy of the proposed method are demonstrated via simulation test on a practical l0kV feeder in China.

Xue, Yaosuo↗

The North American Josephson Voltage Interlaboratory Comparison

The ninth North American Josephson voltage standard (JVS) interlaboratory comparison (ILC) at 10 V was completed in 2011. An on-site comparison was conducted between the National Institute of Standards and Technology compact JVS and the pivot laboratory system. A set of four traveling Zener voltage standards was then shipped from the pivot laboratory to the other participants. Here, we give the results from the 2011 ILC and review recent comparisons which have used the same traveling standards and similar procedures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feedback lock-in: A versatile multi-terminal measurement system for electrical transport devices

Here, we present the design and implementation of a measurement system that enables parallel drive and detection of small currents and voltages at numerous electrical contacts to a multi-terminal electrical device. This system, which we term a feedback lock-in, combines digital control-loop feedback with software-defined lock-in measurements to dynamically source currents and measure small, pre-amplified potentials. The effective input impedance of each current/voltage probe can be set via software, permitting any given contact to behave as an open-circuit voltage lead or as a virtually grounded current source/sink. This enables programmatic switching of measurement configurations and permits measurement of currents at multiple drain contacts without the use of current preamplifiers. Our 32-channel implementation relies on commercially available digital input/output boards, home-built voltage preamplifiers, and custom open-source software. With our feedback lock-in, we demonstrate differential measurement sensitivity comparable to a widely used commercially available lock-in amplifier and perform efficient multi-terminal electrical transport measurements on twisted bilayer graphene and SrTiO 3 quantum point contacts. The feedback lock-in also enables a new style of measurement using multiple current probes, which we demonstrate on a ballistic graphene device.

47 OTHER INSTRUMENTATION↗

PEM Degradation Investigation Final Technical Report

The objectives of this paper are: (1) Develop a system capable of measuring current and voltage performance for each membrane in a Polymer Electrolyte Membranes (PEM) fuel cell stack and record the performance of each individual cell; (2) Develop a single cell PEM FC to allow in situ synchrotron x-ray measurements of the cell in operation and to perform spatially resolved x-ray measurements on fuel cell elements before and after degradation; and (3) Perform initial magnetic resonance microimaging experiments on membrane materials. The Montana State University PEM Membrane Degradation program is geared towards determining how and why membranes in fuel cells degrade and fail. By monitoring every individual membrane in a fuel cell 2000 times/sec while the cell is subjected to real-world type use, we hope to: (1) cause the types of degradation users see, but in a controlled environment; (2) determine an electrical signature that will identify what causes failure, or at least warns of impending failure; (3) allows us to perform advanced x-ray and MRI characterization of the degraded membranes to provide information that may result in improvements of the membrane material; and (4) perhaps allow design of electronic control systems that will prevent fuel cells from operating under conditions where damage is likely to occur.

30 DIRECT ENERGY CONVERSION↗

Sensitivity analysis of a layered piezoelectric system using ZFEM

The complex variable finite element method (ZFEM) is a numerical technique which aims to find the partial derivatives of the independent variables with respect to variation in dependent parameters declared in the physics. This is done by combining the complex Taylor series expansion within the weak formulation of the governing equation in a coupled system of linear equations forming a complex valued block matrix given by the Cauchy–Riemann matrix representation. In this work, two-dimensional linear first-order elements have been implemented in ZFEM to predict the design derivatives of the mechanical displacement field and the voltage potential field for a layered piezoelectric system in a steady-state study with Dirichlet boundary condition applied at the top and bottom edges of the geometry. This approach allows the standard FEM solution to quantify the sensitivity of the mechanical displacement and voltage potential fields with respect to small variations in the material properties through the information obtained from the computation of the derivatives. The domain is formed by a layered body with PZT-4 and PZT-5 stacked together. For result verification, the numerical solution obtained with ZFEM was compared to results from a commercial FEM package and the solution from the imaginary part was compared to the exact solution of a well-known benchmark problem. In conclusion, comparison of the results showed good agreement for both the real and imaginary parts of the solution and the largest sensitivities were found in PZT-5 specifically in C 13 , C 33 , and ε 33 .

42 ENGINEERING↗

The effects of nonlinear loading upon the Space Station Freedom 20 kHz power system

The Space Station Freedom power distribution system, which consists of dual redundant 20-kHz, 440-V RMS, single-phase power systems, is discussed. The effect of a typical space station nonlinear load on the measurement of RMS current and voltage at various points in the space station power system has been investigated using the Electromagnetic Transients Program (EMTP). The load current distortion at the user interface, its effect on the distribution system, and its relationship to power factor have been studied. Modeling results are compared to test data. The differences under nonlinear loading are evaluated and presented as a measure of distribution voltage distortion and current measurement accuracy.

Leskovich, R. Thomas↗

Accelerated Voltage Regulation in Multi-Phase Distribution Networks Based on Hierarchical Distributed Algorithm

Here, we introduce a hierarchical distributed algorithm to solve optimal power flow (OPF) problems that aim at dispatching controllable distributed energy resources (DERs) for voltage regulation at minimum cost. The proposed algorithm highlights unprecedented scalability to large multi-phase distribution networks by jointly exploring the tree/subtrees structure of a large radial distribution network and the structure of the linearized distribution power flow (LinDistFlow) model to derive a hierarchical, distributed implementation of the primal-dual gradient algorithm that solves OPF. The proposed implementation significantly reduces the computation loads compared to the centrally coordinated implementation of the same primal-dual algorithm without compromising optimality. Numerical findings on a 4,521-node test feeder show that the designed algorithm achieves more than 10-fold acceleration in the speed of convergence compared to the centrally coordinated primal-dual algorithm through reducing and distributing computational loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A CW radiofrequency ion source for production of negative hydrogen ion beams for cyclotrons

A CW 13.56 MHz radiofrequency-driven ion source RADIS for production of H{sup −} and D{sup −} beams is under development for replacing the filament-driven ion source of the MCC30/15 cyclotron. The RF ion source has a 16-pole multicusp plasma chamber, an electromagnet-based magnetic filter and an external planar spiral RF antenna behind an AlN window. The extraction is a 5-electrode system with an adjustable puller electrode voltage for optimizing the beam formation, a water-cooled electron dump electrode and an accelerating einzel lens. At 2650 W of RF power, the source produces 1 mA of H{sup −} (2.6 mA/cm{sup 2}), which is the intensity needed at injection for production of 200 µA H{sup +} with the filament-driven ion source. A simple pepperpot device has been developed for characterizing the beam emittance. Plans for improving the power efficiency with the use of a new permanent magnet front plate is discussed.

43 PARTICLE ACCELERATORS↗

Monte Carlo simulation of the effects of anode surface roughness on x-ray spectra

Purpose: Spectral and angular distribution of the x-ray beam generated by medical x-ray tubes as a function of anode surface roughness was analyzed. Methods: Different sets of profiles such as ideal flat, regular profiles, and measured profiles adopted from the literature were analyzed by means of MCNPX Monte Carlo simulator. The geometry used was simplified to separate different physical effects. A sphere centered on the origin of the coordinate system was divided into two hemispheres filled with tungsten and a vacuum, respectively. The studied anode surfaces were placed at the center of the plane of the hemisphere. The profiles were realized by means of the general lattice structure of the MCNPX. The energy and angular distributions of the excited photons were recorded with energy and angular resolutions of 0.5 keV and 1 deg., respectively, by means of point detectors. The range of the studied anode surface roughness was 0-550 {mu}m R{sub a}. The emission angle dependencies of the following quantities were analyzed: Half value layer (HVL) value, intensity, and spectral photon flux. Results: The analysis of the HVL of the x-ray beam showed that around an emission angle of 5 deg., the hardness of the beam was practically independent of the surface roughness. The value of this emission angle depends on the filtration. Below this critical angle, the HVL value decreases, while at a higher emission angle, the beam becomes harder with increasing surface roughness. The intensity degradation saturates with increasing roughness. The position of the maximum spectral photon flux shifts to higher emission angles as the anode surface roughness increases. The surface roughness (R{sub a}) was found to be an inadequate quantity to describe the effect of anode surface roughness on x-ray spectra since no definite connection was found between the values of the intensity degradation and surface roughness. At 120 kVp tube voltage and at a 3.84 {mu}m R{sub a} roughness value, the effect of anode surface roughness introduces a 5% and 12% intensity degradation at a 5 deg. and 12 deg. emission angle, respectively. However, it has a higher impact at low tube voltages (<60 keV), e.g., in mammography systems where the intensity degradation could even be 25% at the ''newly'' polished anode surface. Conclusions: The effects of anode surface roughness on x-ray spectra were successfully simulated by a Monte Carlo method. It was proved that the effect of the anode surface roughness could not be modeled by simple filters made from the anode material. The surface roughness (R{sub a}) was found to be an inadequate quantity to describe the effect of anode surface roughness on x-ray spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bulk Power System Dynamics with Varying Levels of Synchronous Generators and Grid-Forming Power Inverters

Inverters using phase-locked loops for control depend on voltages generated by synchronous machines to operate. This might be problematic if much of the conventional generation fleet is displaced by inverters. To solve this problem, grid-forming control for inverters has been proposed as being capable of autonomously regulating grid voltages and frequency. Presently, the performance of bulk power systems with massive penetration of grid-forming inverters has not been thoroughly studied as to elucidate benefits. Hence, this paper presents inverter models with two grid-forming strategies: virtual oscillator control and droop control. The two models are specifically developed to be used in positive-sequence simulation packages and have been implemented in PSLF. The implementations are used to study the performance of bulk power grids incorporating inverters with gridforming capability. Specifically, simulations are conducted on a modified IEEE 39-bus test system and the microWECC test system with varying levels of synchronous and inverter-based generation. The dynamic performance of the tested systems with gridforming inverters during contingency events is better than cases with only synchronous generation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical safety for high voltage arrays

A number of key electrical safety requirements for the high voltage arrays of central station photovoltaic power systems are explored. The suitability of representative industrial DC power switchgear for control and fault protection was evaluated. Included were AC/DC circuit breakers, electromechanical contactors and relays, load interruptors, cold disconnect devices, sectionalizing switches, and high voltage DC fuses. As appropriate, steady state and transient characteristics were analyzed. Failure modes impacting upon operation and maintenance safety were also identified, as were the voltage withstand and current interruption levels.

Marshall, N. A.↗

Hybrid Ion-Detector/Data-Acquisition System for a TOF-MS

A modified ion-detector/data-acquisition system has been devised to increase the dynamic range of a time-of-flight mass spectrometer (TOF-MS) that, previously, included a microchannel-plate detector and a data-acquisition system based on counting pulses and time-tagging them by use of a time-to-digital converter (TDC). The dynamic range of the TOF-MS was limited by saturation of the microchannel plate detector, which can handle no more than a few million counts per second. The modified system includes (1) a combined microchannel plate/discrete ion multiplier and (2) a hybrid data-acquisition system that simultaneously performs analog current or voltage measurements and multianode single-ion-pulse-counting time-of-flight measurements to extend the dynamic range of a TDC into the regime in which a mass peak comprises multiple ions arriving simultaneously at the detector. The multianode data are used to determine, in real time, whether the detector is saturated. When saturation is detected, the data-acquisition system selectively enables circuitry that simultaneously determines the ion-peak intensity by measuring the time profile of the analog current or voltage detector-output signal.

Burton, William D., Jr.↗

Verification of a Modeling Toolkit for the Design of Building Electrical Distribution Systems

DC electrical distribution systems offer many potential advantages over their AC counterparts. They can facilitate easier integration with distributed energy resources, improve system energy efficiency by eliminating AC/DC converters at end-use devices (e.g., laptop chargers), and reduce installation material, time, and cost. However, DC electrical distribution systems present additional design considerations, largely resulting from potentially greater magnitude and variation in cable losses. Modeling and simulation are rarely used to design such systems. However, the greater dependency of DC system energy efficiency on design choices such as distribution voltages, architecture, and integration of PV and BESS suggests that modeling and simulation may be required. Such system performance analysis is currently not a standard practice, in part due to limited availability and validation of capable software tools. This paper characterizes the accuracy of a Modelica-based Building Electrical Efficiency Analysis Model (BEEAM) toolkit, as a precursor for validating its use to perform system performance analysis and inform design decisions. The study builds upon previous verification research by characterizing complete systems comprised of commercially available equipment, and providing a more detailed analysis of simulation results. Five lighting systems with varying electrical distribution architectures were designed using market-available equipment, installed in a laboratory environment, modeled using BEEAM, and simulated using three Modelica integrated development environments (IDEs). Simulated and measured results were compared to characterize toolkit accuracy. Initial results revealed that simulated performance was mostly within ±5% of measured system-level and device-level performance. While simulation results were not found to be dependent on the IDE, some Modelica compiler interoperability issues were identified. Although the BEEAM toolkit showed promise for the targeted use case, further work is needed to determine whether the demonstrated 5% accuracy is sufficient for making real-world design decisions, and for BEEAM to advance from an interesting research tool to one that can impact real-world building projects.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Verification of a novel method for tube voltage constancy measurement of orthovoltage x-ray irradiators

Purpose: For orthovoltage x-ray irradiators, the tube voltage is one of the most fundamental system parameters as this directly relates to the dosimetry in radiation biology studies; however, to the best of our knowledge, there is no commercial portable quality assurance (QA) tool to directly test the constancy of the tube voltage greater than 160 kV. The purpose of this study is to establish the Beam Quality Index (BQI), a quantity strongly correlated to the tube voltage, as an alternative parameter for the verification of the tube voltage as part of the QA program of orthovoltage x-ray irradiators. Methods: A multipurpose QA meter and its associated data acquisition software were used to customize the measurement parameters to measure the BQI and collect its time-plot. BQI measurements were performed at 320 kV with four filtration levels on three orthovoltage x-ray irradiators of the same model, one of which had been recently energy-calibrated at the factory. Results: For each of the four filtration levels, the measured BQI values were in good agreement (<5%) between the three irradiators. BQI showed filtration-specificity, possibly due to the difference in beam quality. Conclusions: The BQI has been verified as a feasible alternative for monitoring the constancy of the tube voltage for orthovoltage irradiators. The time-plot of BQI offers information on the behavior of beam energy at different phases of the irradiation time line. In addition, this would provide power supply performance characteristics from initial ramp-up to plateau, and finally, the sharp drop-off at the end of the exposure.

60 APPLIED LIFE SCIENCES↗

Refine your search to explore more results.