Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system planning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

External Validation and Optimization of International Consensus Clinical Target Volumes for Adjuvant Radiation Therapy in Bladder Cancer

Purpose: International consensus (IC) clinical target volumes (CTVs) have been proposed to standardize radiation field design in the treatment of patients at high risk of locoregional failure (LRF) after radical cystectomy. The purpose of this study was to externally validate the IC CTVs in a cohort of postsurgical patients followed up for LRF and identify revisions that might improve the IC CTVs' performance. Methods and Materials: Among 334 patients with pT3 to pT4 bladder cancer treated with radical cystectomy, LRF developed in 58 (17%), of whom 52 had computed tomography scans available for review. Images with LRF were exported into a treatment planning system, and IC CTVs were contoured and evaluated for adequacy of coverage of each LRF with respect to both the patient and each of 6 pelvic subsites: common iliac (CI) region, obturator region (OR), external and internal iliac region, presacral region, cystectomy bed, or other pelvic site. Revisions to the IC contours were proposed based on the findings. Results: Of the 52 patients with documented LRF, 13 (25%) had LRFs that were outside of the IC CTV involving 17 pelvic subsites: 5 near the CI CTV, 5 near the OR CTV, 1 near the external and internal iliac region, and 6 near the cystectomy bed. The 5 CI failures were located superior to the CTV, and the 5 OR failures were located medial to the CTV. Increasing the superior boundary of the CI to a vessel-based definition of the aortic bifurcation, as well as increasing the medial extension of the OR by an additional 9 mm, decreased the number of patients with LRF outside of the IC CTV to 7 (13%). Conclusions: Modified IC CTVs inclusive of a slight adjustment superiorly for the CI region and medially for the OR may reduce the risk of pelvic failure in patients treated with adjuvant radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Hypothermia as a Radioprotector of the Rectal Wall During Prostate Stereotactic Body Radiation Therapy

Purpose: To compare the single-fraction dose-related incidence of rectal obstruction and/or bleeding in normothermic and hypothermic rectums of a rat model. Methods and Materials: A 1.9-cm length of rectum was irradiated with a single fraction in 57 Sprague-Dawley rats using a dedicated image-guided small animal irradiator and Monte Carlo–based treatment planning system. All rats had a rectal temperature control apparatus placed during irradiation and were stratified to achieve either a normothermic (37°C) or hypothermic (15°C) rectal wall temperature. Radiation was delivered to a 1-cm-diameter cylindrical volume about the cooling device and rectal wall. The radiation dose was escalated from 16 Gy up to 37 Gy to assess the dose response in each arm. The primary endpoint of this study was rectal obstruction and/or bleeding during a follow-up of 180 to 186 days. Histologic scoring was performed on all study rats. Results: Probit analysis showed a dose associated with a 50% incidence of rectal obstruction of 24.6 Gy and 40.8 Gy for normothermic and hypothermic arms, respectively. The occurrence of obstruction and/or bleeding correlated with the posttreatment histologic score for normothermic rats; however, there was no difference in histologic score between normothermic and hypothermic rats at the highest dose levels evaluated. Conclusions: A significant radioprotective effect was observed using local hypothermia during a single large dose of radiation for the functional endpoint of rectal obstruction and/or bleeding. A confirmatory study in a large animal model with anatomic and physiologic similarities to humans is suggested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Four Volume-Based Image Registration Algorithms

We evaluated 4 volume-based automatic image registration algorithms from 2 commercially available treatment planning systems (Philips Syntegra and BrainScan). The algorithms based on cross correlation (CC), local correlation (LC), normalized mutual information (NMI), and BrainScan mutual information (BSMI) were evaluated with: (1) the synthetic computed tomography (CT) images, (2) the CT and magnetic resonance (MR) phantom images, and (3) the CT and MR head image pairs from 12 patients with brain tumors. For the synthetic images, the registration results were compared with known transformation parameters, and all algorithms achieved accuracy of submillimeter in translation and subdegree in rotation. For the phantom images, the registration results were compared with those provided by frame and marker-based manual registration. For the patient images, the results were compared with anatomical landmark-based manual registration to qualitatively determine how the results were close to a clinically acceptable registration. NMI and LC outperformed CC and BSMI, with the sense of being closer to a clinically acceptable result. As for the robustness, NMI and BSMI outperformed CC and LC. A guideline of image registration in our institution was given, and final visual assessment is necessary to guarantee reasonable results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy and Larynx Sparing in Advanced Oropharyngeal Carcinoma: A Dosimetric Study

Intensity-modulated radiation therapy (IMRT) is gaining acceptance as a standard treatment technique for advanced squamous cell carcinoma (SCC) of the oropharynx. Dose to the uninvolved larynx and surrounding structures can pose a problem in patients with significant neck disease, potentially compromising laryngeal function and quality of life. Tomotherapy may allow greater laryngeal sparing. Seven patients with stage IV SCC of the oropharynx were replanned using Tomotherapy version 3.1. All contours/planning target volumes (PTVs) from the original plans were preserved, with the exception of the larynx, which was drawn to include all soft tissue encompassed by the thyroid/cricoid cartilage. A simultaneous integrated boost technique was used with PTV 1, 2, and 3 receiving 69.96, 59.40, and 54.00 Gy, respectively in 33 fractions. Dosimetry was evaluated via the Pinnacle treatment planning system (TPS). Equivalent uniform dose (EUD) was calculated from the dose volume histogram (DVH) using the general method with 'a' = 5.0. Mean larynx dose for all patients was 24.4 Gy. Mean EUD to the larynx was 34.2 Gy. Homogeneity was adequate; average maximum dose was 109.7% of the highest prescription. All other organs at risk (OAR) were adequately spared. Tomotherapy can spare the uninvolved larynx in the setting of advanced SCC of the oropharynx to levels that are similar to or better than those reported with other techniques. Sparing is achieved without compromising target coverage or other OAR sparing. The clinical benefit of this sparing remains to be determined in a prospective study.

61 RADIATION PROTECTION AND DOSIMETRY↗

On Comparing the Quality of Head and Neck Imrt Plans Delivered with Two Different Linear Accelerator Manufacturers

The purpose of this work was to determine whether 2 different types of linear accelerators manufacturers with similar MLC leaf widths deliver equivalent IMRT distributions for head and neck radiotherapy patients. In this study, plans delivered with Siemens linacs were re-optimized with an Elekta linac and vice versa. To test for significance, paired t-tests were computed to examine differences in target and normal tissue doses and monitor units. Dose distributions, dose-volume histograms, and dose to targets and normal tissues were found to be equivalent irrespective of the linac type. However, approximately 15% more monitor units were delivered when planned on the Elekta machine (p < 0.002). Both linear accelerators provide plans of comparable dosimetric quality; however, Elekta machines deliver slightly more monitor units than Siemens machines. This increase is likely due differences in geometric properties of the machine head designs, as modeled in the treatment planning system.

61 RADIATION PROTECTION AND DOSIMETRY↗

Midline Dose Verification with Diode In Vivo Dosimetry for External Photon Therapy of Head and Neck and Pelvis Cancers During Initial Large-Field Treatments

During radiotherapy treatments, quality assurance/control is essential, particularly dose delivery to patients. This study was designed to verify midline doses with diode in vivo dosimetry. Dosimetry was studied for 6-MV bilateral fields in head and neck cancer treatments and 10-MV bilateral and anteroposterior/posteroanterior (AP/PA) fields in pelvic cancer treatments. Calibrations with corrections of diodes were performed using plastic water phantoms; 190 and 100 portals were studied for head and neck and pelvis treatments, respectively. Calculations of midline doses were made using the midline transmission, arithmetic mean, and geometric mean algorithms. These midline doses were compared with the treatment planning system target doses for lateral or AP (PA) portals and paired opposed portals. For head and neck treatments, all 3 algorithms were satisfactory, although the geometric mean algorithm was less accurate and more uncertain. For pelvis treatments, the arithmetic mean algorithm seemed unacceptable, whereas the other algorithms were satisfactory. The random error was reduced by using averaged midline doses of paired opposed portals because the asymmetric effect was averaged out. Considering the simplicity of in vivo dosimetry, the arithmetic mean and geometric mean algorithm should be adopted for head/neck and pelvis treatments, respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Pelvic Phantom for Modeling Internal Organ Motions

A pelvic phantom was developed for use in testing image-guided radiation therapy (IGRT) and adaptive applications in radiation therapy (ART) with simulating the anterior-posterior internal organ motions during prostate radiotherapy. Measurements could be done with an ionization chamber (IC) in the simulated prostate. The rectum was simulated by air-equivalent material (AEM). The volume superior to the IC placement was considered as the bladder. The extension of AEM volume could be varied. The vertical position of the IC placement could be shifted by {+-}1 cm to simulate the prostate motion parallel to the changes in bladder volume. The reality of the simulation was inspected. Three-millimeter-slice-increment computed tomography (CT) scans were taken for irradiation planning. The structure set was adapted to the phantom from a treated patient. Planning target volume was delineated according to the RTOG 0126 study. IMRT and 3D conformal radiation therapy (3D-CRT) plans were made. Prostate motion and rectum volume changes were simulated in the phantom. IC displacement was corrected by phantom shifting. The delivered dose was measured with IC in 7 cases using intensity-modulated radiation therapy (IMRT) and 3D-CRT fractions, and single square-shaped beams: anteroposterior (AP), posteroanterior (PA), and lateral (LAT). Variations from the calculated doses were slightly below 1% at IMRT and around 1% at 3D-CRT; below 4.5% at square AP beam; up to 9% at square PA beam; and around 0.5% at square LAT beam. Other authors have already shown that by using planning systems and ultrasonic and cone beam CT guidance, correction of organ motions in a real patient during prostate cancer IGRT does not have a significant dosimetric effect. The inspection of our phantom-as described here-ended with similar results. Our team suggested that our model is sufficiently realistic and can be used for IGRT and ART testing.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric Comparison of Manual and Beam Angle Optimization of Gantry Angles in IMRT

Dosimetric comparison of manual beam angle selection (MBS) and beam angle optimization (BAO) for IMRT plans is investigated retrospectively for 15 head and neck and prostate patients. The head and neck and prostate had planning target volumes (PTVs) ranging between 96.0 and 319.9 cm{sup 3} and 153.6 and 321.3 cm{sup 3}, whereas OAR ranged between 8.3 and 47.8 cm{sup 3} and 68.3 and 469.2 cm{sup 3}, respectively. In MBS, a standard coplanar 7-9 fields equally spaced gantry angles were used. In BAO, the selection of gantry angle was optimized by the algorithm for the same number of beams. The optimization and dose-volume constraints were kept the same for both techniques. Treatment planning was performed on the Eclipse treatment planning system. Our results showed that the dose-volume histogram for PTV are nearly identical in both techniques but BAO provided superior sparing of the organs at risk compared with the MBS. Also, MBS produced statistically significant higher monitor units (MU) and segments than the BAO; 13.1 {+-} 6.6% (p = 0.012) and 10.4 {+-} 13.6% (p = 0.140), and 14.6 {+-} 5.6% (p = 1.003E-5) and 12.6 {+-} 7.4% (p = 0.76E-3) for head and neck and prostate cases, respectively. The reduction in MU translates into the reduction in total body and integral dose. It is concluded that BAO provides advantage over MBS for most intenisty-modulated radiation therapy cases.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric comparison between model 9011 and 6711 sources in prostate implants

The purpose of this work is to evaluate the model 9011 iodine-125 ({sup 125}I) in prostate implants by comparing dosimetric coverage provided by the 6711 vs 9011 source implants. Postimplant dosimetry was performed in 18 consecutively implanted patients with prostate cancer. Two were implanted with the 9011 source and 16 with the 6711 source. For purposes of comparison, each implant was then recalculated assuming use of the other source. The same commercially available planning system was used and the specific source data for both 6711 and 9011 products were entered. The results of these calculations are compared side by side in the terms of the isodose values covering 100% (D100) and 90% (D90) of prostate volume, and the percentages of volumes of prostate, bladder, rectum, and urethra covered by 200% (V200), 150% (V150), 100% (V100), 50% (V50), and 20% (V20) of the prescribed dose as well. The 6711 source data overestimate coverage by 6.4% (ranging from 4.9% to 6.9%; median 6.6%) at D100 and by 6.6% (ranging from 6.2% to 6.8%; median 6.6%) at D90 compared with actual 9011 data. Greater discrepancies of up to 67% are seen at higher dose levels: average reduction for V100 is 2.7% (ranging from 0.6% to 7.7%; median 2.3%), for V150 is 14.6% (ranging from 6.1% to 20.5%; median 15.3%), for V200 is 14.9% (ranging from 4.8% to 19.1%; median 16%); similarly seen in bladder, rectal, and urethral coverage. This work demonstrates a clear difference in dosimetric behavior between the 9011 and 6711 sources. Using the 6711 source data for 9011 source implants would create a pronounced error in dose calculation. This study provides evidence that the 9011 source can provide the same dosimetric quality as the 6711 source, if properly used; however, the 6711 source data should not be considered as a surrogate for the 9011 source implants.

61 RADIATION PROTECTION AND DOSIMETRY↗

Use of proton beams with breast prostheses and tissue expanders

Since the early 2000s, a small but rapidly increasing number of patients with breast cancer have been treated with proton beams. Some of these patients have had breast prostheses or tissue expanders in place during their courses of treatment. Procedures must be implemented to plan the treatments of these patients. The density, kilovoltage x-ray computed tomography numbers (kVXCTNs), and proton relative linear stopping powers (pRLSPs) were calculated and measured for several test sample devices. The calculated and measured kVXCTNs of saline were 1% and 2.4% higher than the values for distilled water while the calculated RLSP for saline was within 0.2% of the value for distilled water. The measured kVXCTN and pRLSP of the silicone filling material for the test samples were approximately 1120 and 0.935, respectively. The conversion of kVXCTNs to pRLSPs by the treatment planning system standard tissue conversion function is adequate for saline-filled devices but for silicone-filled devices manual reassignment of the pRLSPs is required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Environmental trade-offs of direct air capture technologies in climate change mitigation toward 2100

Abstract Direct air capture (DAC) is critical for achieving stringent climate targets, yet the environmental implications of its large-scale deployment have not been evaluated in this context. Performing a prospective life cycle assessment for two promising technologies in a series of climate change mitigation scenarios, we find that electricity sector decarbonization and DAC technology improvements are both indispensable to avoid environmental problem-shifting. Decarbonizing the electricity sector improves the sequestration efficiency, but also increases the terrestrial ecotoxicity and metal depletion levels per tonne of CO 2 sequestered via DAC. These increases can be reduced by improvements in DAC material and energy use efficiencies. DAC exhibits regional environmental impact variations, highlighting the importance of smart siting related to energy system planning and integration. DAC deployment aids the achievement of long-term climate targets, its environmental and climate performance however depend on sectoral mitigation actions, and thus should not suggest a relaxation of sectoral decarbonization targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Land-use and atmospheric shifts jointly amplify U.S. drought-driven crop losses

Agricultural drought (AD) poses a major threat to food security, yet its future risk remains uncertain under co-evolving atmospheric conditions and land-use trajectories. Using an integrated, multi-sector modeling framework, we project AD risks for major crops across the contiguous United States (CONUS) through 2055 under a range of plausible futures that capture thermodynamic changes and land-use and land-cover change (LULCC) trajectories. Model projections reveal that drought-driven crop production losses increase sharply by nearly 60% for corn, 250% for wheat, and 135% for soybean relative to historical levels. The primary drivers of these increases, which include atmospheric shifts and LULCC, vary by region and crop type. LULCC acting as an important risk amplifier in regions experiencing cropland expansion into drought-prone regions, such as the Great Plains and northwestern U.S. Wheat exhibits the largest projected loss increases, a result that remains robust across scenarios. These findings highlight that interactions between atmospheric conditions and land-use trajectories shape future agricultural drought risk and should be jointly considered to support effective adaptation and food-system planning.

Yao, Lili↗

Single crystal chemical vapor deposited diamond detectors for intensity-modulated radiation therapy applications

We report here on first intensity-modulated radiation therapy (IMRT) clinical tests performed at the Gustave Roussy Institute in France using one small (0.117 mm{sup 3}) synthetic single crystal diamond detector (SCDD). We report the comparison between the point doses evaluated with our detector, with a PTW semiflex air ionization chamber (0.125 cm{sup 3}) and calculated with the treatment planning system (TPS), respectively. The obtained results show a maximum difference of 2.3% for the diamond detector and of 4.6% for the ionization chamber, as compared with the TPS calculations. These very promising results show the potentiality of chemical vapor deposited SCDD for dosimetry of IMRT fields and opens up the field for diamond dosimeters toward novel applications such as very small beam monitoring.

36 MATERIALS SCIENCE↗

'In vivo' Dose Measurements in High-Dose-Rate Brachytherapy Treatments for Cervical Cancer: A Project Proposal

The aim of this thesis project is to compare doses calculated from the treatment planning system using computed tomography images, with those measured 'in vivo' by using thermoluminescent dosimeters placed at different regions of the rectum and bladder of a patient during high-dose-rate intracavitary brachytherapy treatment of uterine cervical carcinoma. The experimental dosimeters characterisation and calibration have concluded and the protocol to carry out the 'in vivo' measurements has been established. In this work, the calibration curves of two types of thermoluminescent dosimeters (rods and chips) are presented, and the proposed protocol to measure the 'in vivo' dose is fully described.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-induced complications in prostate cancer patients treated with radiotherapy

The purpose of the study is to determine the relationship between radiation-induced complications with dosimetric and radiobiological parameters for prostate cancer patients that underwent the conformal radiotherapy treatment. 17 prostate cancer patients that have been treated with conformal radiotherapy were retrospectively analysed. The dosimetric data was retrieved in the form of dose-volume histogram (DVH) from Radiotherapy Treatment Planning System. The DVH was utilised to derived Normal Tissue Complication Probability (NTCP) in radiobiological data. Follow-up data from medical records were used to grade the occurrence of acute gastrointestinal (GI) and genitourinary (GU) complications using Radiation Therapy Oncology Group (RTOG) scoring system. The chi-square test was used to determine the relationship between radiation-induced complication with dosimetric and radiobiological parameters. 8 (47%) and 7 (41%) patients were having acute GI and GU complications respectively. The acute GI complication can be associated with V60{sub rectum}, rectal mean dose and NTCP{sub rectum} with p-value of 0.016, 0.038 and 0.049 respectively. There are no significant relationships of acute GU complication with dosimetric and radiobiological variables. Further study can be done by increase the sample size and follow up duration for deeper understanding of the factors that effecting the GU and GI complication in prostate cancer radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

What happens when spins meet for ionizing radiation dosimetry?

Electron spin resonance (ESR) and magnetic resonance imaging (MRI) can be used to measure radiation dose deposited in different milieu through its effects. Radiation can break chemical bonds and if they produce stable free radicals, ESR can measure their concentration through their spins and a dose can be inferred. Ionizing radiation can also promote polymerization and in this case proton relaxation times can be measured and an image weighed by T2 can be produced giving spatial information about dose. A review of the basics of these applications is presented concluding with an end-to-end test using a composite Gel-Alanine phantom to validate 3-dimensionally dose distribution delivered in a simulation of Volume Modulated Arch Therapy on the simultaneous treatment of multiple brain metastases. The results obtained with the gel and alanine dosimeters are consistent with the expected by the treatment planning system, showing the potential of this multidosimetric approach and validating dosimetrically the multiple brain metastases treatment using VMAT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cosmic Muon Veto for the mini-ICAL detector at IICHEP, Madurai

A 51-kiloton magnetised Iron Calorimeter (ICAL) detector, using Resistive Plate Chambers (RPCs) as active detector elements, aims to study atmospheric neutrinos. A prototype - 1/600 of the weight of ICAL, called mini-ICAL was installed in the INO transit campus at Madurai. A modest proof-of-principle cosmic muon veto detector of about 1 m × 1 m × 0.3 m dimensions was setup a few years ago, using scintillator paddles. The measured cosmic muon veto efficiency of 99.98% and simulation studies of muon-induced background events in the ICAL detector surrounded by an efficient veto detector were promising. This led to the idea of constructing a bigger cosmic muon veto around the mini-ICAL detector. Details of the design and construction of the detector including the electronics, trigger and DAQ systems planned will be briefly presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

River systems under peaked stress

The change in the global energy production mix towards variable renewable energy sources requires efficient utilization of regulated rivers to optimise hydropower operations meet the needs of a changing energy market. However, the flexible operation of hydropower plants causes non-natural, sub-daily fluctuating flows in the receiving water bodies, often referred to as ‘hydropeaking’. Drastic changes in sub-daily flow regimes undermine attempts to improve river system health. Environmental decision makers, including permitting authorities and river basin managers facing the intense and increasing pressure on river environments, should consider ecosystem services and biodiversity issues more thoroughly. The need for research innovations in hydropeaking operation design to fulfil both the water and energy security responsibilities of hydropower is highlighted. Our paper outlines optimized hydropeaking design as a future research direction to help researchers, managers, and decision-makers prioritize actions that could enable better integration of river science and energy system planning. The goal of this is to find a balanced hydropower operation strategy.

54 ENVIRONMENTAL SCIENCES↗

Refine your search to explore more results.