Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “submillimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Sensors and detectors in NASA's future missions

Advances in electronics are responsible for major improvements in NASA's sensing and detection capabilities for future space missions. Technologies such as charge-transfer devices, tunable diode lasers, millimeter and submillimeter wave solid-state receiver components, large-scale circuit integration, new electronic materials and processing techniques, and novel detector electronics are contributing to the goal of a tenfold increase in the capacity of data collection from future platforms and will be used for space exploration and utilization.

Rubin, B.↗

Space-based radio telescopes and an orbiting deep-space relay station

Foremost among the candidates for early utilization of the Shuttle-launched self-deployable structures are the space-based radio telescopes. Several space-based telescopes are examined including an orbiting VLBI terminal, an orbiting submillimeter telescope, and a large ambient deployable IR telescope. Particular consideration is given to the high-gain Orbiting Deep-Space Relay Station for communication with deep-space probes. Details of deployable antenna technology are discussed.

Powell, R. V.↗

Far-infrared lasing in ruby

The feasibility of submillimeter wavelength (870 GHz) lasing in Al2O3 is discussed. The proposed scheme is based on the pumping of the 2A level of ruby via a ruby laser operating on its R2 line. Lasing is expected on the 2A to E transition of the split E-2 level.

Lawandy, N. M.↗

Far infrared heterodyne systems

Three far infrared detectors, the InSb hot electron bolometer, the GaAs Schottky diode and the Josephson point contact junction, were incorporated as mixers into sensitive heterodyne systems. The performances of existing heterodyne receivers/radiometers using these detectors are described and compared. Other applications of submillimeter heterodyne techniques are discussed.

Tannenwald, P. E.↗

Sub mm laser local oscillators: Design criteria and results

Diagnostic results are given of the spectral features and the power conversion efficiency of submillimeter (SMM) laser local oscillators. Several criteria are obtained for the design of frequency stable and efficient smm lasers for local oscillator applications. Finally, a design is described and results on the power output and power and frequency stability are given. The mode pattern is very close to a Gaussian profile so that efficient coupling to a quasioptical mixer is possible. The laser provides sufficient output power at a large number of lines to drive the mixer into the low conversion loss regime. Radiometric integration times of several minutes with a spectral resolution of 1 MHz will be possible. With present state-of-the-art Schottky mixers and low noise preamplifiers a radiometric temperature resolution of a few K can be expected over a spectral range from 500to 900 GHz.

Koepf, G. A.↗

Large Deployable Reflector (LDR)

The feasibility and costs were determined for a 1 m to 30 m diameter ambient temperature, infrared to submillimeter orbiting astronomical telescope which is to be shuttle-deployed, free-flying, and have a 10 year orbital life. Baseline concepts, constraints on delivery and deployment, and the sunshield required are examined. Reflector concepts, the optical configuration, alignment and pointing, and materials are also discussed. Technology studies show that a 10 m to 30 m diameter system which is background and diffraction limited at 30 micron m is feasible within the stated time frame. A 10 m system is feasible with current mirror technology, while a 30 m system requires technology still in development.

Alff, W. H.↗

Distortions of the cosmic microwave background spectrum by dust

The effects of dust in the early universe on the spectrum of the cosmic microwave background are considered, taking into account the effects of a pregalactic generation of stars. It is shown that observed distortions of the background spectrum from that of a black body at 3 K could be due to emission by silicate dust grains at a metal abundance of 0.00001 by mass and with a substantial energy input, which represent the remnants of population III stars. Attempts to fit the microwave background spectrum to the model of Rees (1978) in which the entire cosmic background is accounted for by grain emission are shown to require an implausible value for the metal abundance at early epochs, and not to agree with the millimeter and submillimeter spectrum observed by Woody and Richards (1979).

Rowan-Robinson, M.↗

Fourier spectroscopy of the stratospheric emission

Stratospheric emission spectra in the submillimeter range have been recorded with a resolution of 0.0033/cm with a balloon-borne interferometer. Several minor atmospheric constituents have been identified in a preliminary analysis of the spectra; these are water vapor, oxygen, ozone isotopes, nitric acid, nitrous oxide, hydrofluoric and hydrochloric acids, and carbon monoxide.

Carli, B.↗

Far-infrared observations of the globule B335

Far-infrared and submillimeter continuum emission from the dark globule B335 was observed. The spectrum is that of optically thin thermal emission from dust with temperature 13-16 K. The estimated dust mass is 0.07-0.17 solar masses. The observed luminosity, 5 solar luminosities, can be supplied by the interstellar radiation field.

Keene, J.↗

Brightness temperatures of Saturn's disk and rings at 400 and 700 micrometers

Observations at wavelengths longer than 300 microns provide temperature measurements at deeper layers in the atmosphere of giant planets because opacities are reduced. Submillimeter observations of Saturn were made in November 1979 when the inclination angle of the rings was 1.2 degrees. A 55 sec focal plane aperture was used along with two filters with spectral passbands of 300 to 800 microns (mean wavelength approximately 400 microns) and 500 to 850 microns (mean wavelength approximately 700). Mean brightness temperatures of 121 + or - 12 K at 400 microns and 139 + or - 15 K at 700 microns are reported. The brightness temperatures fall below predictions of atmospheric models at shorter wavelengths, requiring an opacity source besides the pressure-broadened hydrogen lines. In combination with measurements at larger inclination angles, the results yield a 400 micrometer brightness temperature for the rings of approximately 75 K.

Whitcomb, S. E.↗

A technology development program for large space antennas

Recent studies sponsored by NASA and United States industry indicate a need for technology to handle large space-based antenna systems. These systems will require apertures of up to 100 m and more in order to be capable of radio frequency operation up to Ku-band for communications, earth observations, and radio astronomy applications. They must also be cost-effective and compatible with the Space Transportation System. Selection criteria for the antennas which include such considerations as surface precision in the intended service environment and mechanical packaging efficiency, are enumerated. Space testing of the antennas will be carried out as part of NASA's Large Space Systems Technology (LSST) Program, which will be continued through fiscal year 1984. Deployable antennas have been selected for development by the LSST Program. The maturity of this class of antennas is such that a significant number of near-term space based applications will be satisfied (mobile communications, submillimeter radio astronomy, orbiting deep space relay station ODSRS, orbiting VLBI, earth-looking radiometry). Two antenna concepts selected for development are the offset wrap-rib configuration and the maypole (hoop/column) configuration with details for these concepts presented.

Russell, R. A.↗

Detection of the J = 6 - 5 transition of carbon monoxide

The J = 6 - 5 rotational transition of carbon monoxide has been detected in emission from the KL 'plateau source' in the Orion molecular cloud. The corrected peak antenna temperature is 100 K, and the FWHM line width is 26 km/sec. These observations were carried out using the 3 m telescope of the NASA IRTF (Infrared Telescope Facility) on Mauna Kea, Hawaii, and constitute the first astronomical data obtained at submillimeter wavelengths with a heterodyne system using a laser local oscillator. The data support the idea that the high-velocity dispersion CO in Orion is optically thin and set a lower limit to its temperature of approximately 180 K.

Goldsmith, P. F.↗

Properties of an imaging gas scintillation proportional counter

An instrument which combines the improved energy resolution offered by the gas scintillation proportional counter (GSPC) with the submillimeter imaging capabilities of the multiwire proportional counter (MWPC) is described. The imaging gas scintillation proportional counter detects the centroid of the UV light excited by X-ray photons interacting in the noble gas of the GSPC with a UV sensitive gas in the MWPC. The prototype counter yields a measured performance of 9% (FWHM) energy resolution and 0.9 mm (FWHM) spatial resolution at 6 keV. Further design refinements should achieve 18% (FWHM) energy resolution and 0.6 mm (FWHM) spatial resolution at 1 keV.

Ku, W. H.-M.↗

Imaging X-ray spectrophotometers

A new instrument which combines the good energy resolution of the gas scintillation proportional counter with the high position resolution of the microchannel plate is proposed. A study of the factors which determine the combined energy and position resolution of the new instrument is discussed. Submillimeter position resolution along with good energy resolution (8% fwhm at 6 keV) should be achievable.

Hailey, C. J.↗

Far-infrared measurements of trace gases

A better detector system was developed for far infrared spectroscopy by usng cryogenic technology to cool bolometric detectors to approximately 0.4K. Technical assistance was provided to two submillimeter infrared balloon experiment (SIBEX) flights which demonstrated the diagnostic capability of far IR emission spectroscopy. It is estimated that more than a hundred spectral emission features were detected which are not due to the main emitting gases O3, O2, and H2O. The trace species sources for many features still remain unidentified and the spectra obtained during the SIBEX flights present a new source of information on stratospheric composition.

Nolt, I. G.↗

Bulk and integrated acousto-optic spectrometers for radio astronomy

The development of sensitive heterodyne receivers (front end) in the centimeter and millimeter range, and the construction of sensitive RF spectrometers (back end) enable the spectral lines of interstellar molecules to be detected and identified. A technique was developed which combines acoustic bending of a collimated coherent light beam by a Bragg cell followed by detection by a sensitive array of photodetectors (thus forming an RF acousto-optic spectrometer (AOS). An AOS has wide bandwidth, large number of channels, and high resolution, and is compact, lightweight, and energy efficient. The thrust of receiver development is towards high frequency heterodyne systems, particularly in the millimeter, submillimeter, far infrared, and 10 micron spectral ranges.

Chin, G.↗

Microwave rotational spectroscopy

The region of planetary atmospheres upward of 1 millimeter is considered. The applications of this region, how microwave, millimeter, and submillimeter spectra (the so called rotational spectra) can fruitfully interact with infrared spectral measurements are described. Both the rotational bands and vibrational bands of molecules are considered. A typical rotational absorption coefficient for a linear molecule in a low J state with a dipole moment of about one Debye is plotted and evaluated. A vibrational case was chosen similarly: the transition dipole moment used for the vibrational case is typical of CO at the peak of its rotational distribution. Information on high altitude parameters that often cannot be obtained from higher frequency spectra, which can be provided by rotational spectra is discussed.

Pickett, H.↗

Spectral response from blackbody measurements

Far-infrared and submillimeter detector responsivity and spectral response measurements can be performed simultaneously by sweeping the temperature of a cooled blackbody. Such measurements yield n simultaneous linear equations for n blackbody temperatures. Matrix inversion solutions are observed to fail due to a matrix ill-conditioned for inversion. However, an unconditionally convergent iterative solution can be performed. Results for a gallium-doped germanium detector are described.

Moore, W. J.↗

Refine your search to explore more results.