Lab Scale Study of Energetic Gas Stimulation in Engineered Materials.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
Abstract not provided.
2022 Carbon Management Project Review Meeting, Pittsburgh, PA, August 15-19, 2022
A cylindrical microelectrode array having an elongated cylindrical core, and a multilayer structure conformally folded around and affixed to the cylindrical core so as to extend between opposite ends of the core. The multilayer structure has integrated sections including an electrode section with electrodes exposed through electrically insulating layers, a connector section with conductive bond pads for interfacing with external electronics, and a cable section with conductive traces encapsulated in electrically insulating layers and which connect between the electrodes and their corresponding bond pads. The array may be fabricated using a planar multilayer structure having the electrode, connector, and cable sections, and conformally folding the multilayer structure around and affixing to the cylindrical core. The cable section in particular may be conformally coiled around and affixed to the cylindrical core so that the electrical conduits helically extend between the connector and electrode sections.
The present invention provides a family of non-naturally occurring polypeptides having cholesterol efflux activity that parallels that of full-length apolipoproteins (e.g., Apo AI and Apo E), and having high selectivity for ABCA1 that parallels that of full-length apolipoproteins. Further, the peptides of the invention have little or no toxicity when administered at therapeutic and higher doses. The invention also provides compositions comprising such polypeptides, methods of identifying, screening and synthesizing such polypeptides, and methods of treating, preventing or diagnosing diseases and disorders associated with dyslipidemia, hypercholesterolemia, or inflammation; or diseases involving abnormal glucose metabolism, e.g., diabetes, metabolic syndrome; or Alzheimer's Disease or frontotemporal dementia.
Explore the source record for details and available documents.
We describe a device and method that uses elevated electron emission rates to identify surface defects in fine wires. The device is a gas-tight cylinder with fine wires strung across it. The wire to be tested is positioned on the axis of the device. Eighteen field forming and six sensor wires surround the wire to be tested. Special algorithms control the wire voltages to independently vary the surface electric field of the test wire, while keeping the sensor wire's gains consistent. Good surface-quality wires show a constant electron emission rate as a function of the surface electric field strength up to values of ~80 kV/cm (depending on wire radius) while bad-quality wire shows the emergence of high emission rates at significantly lower electric fields.
Abstract not provided.
For presentation at the Geologic Society of America Annual Meeting, Pittsburgh, PA, October 15-18, 2023.
The dismantling of the former German fuel reprocessing research center Wiederaufbeitungsanlage Karlsruhe requires extensive investigations of contamination and dose rate inside of the shielded areas. Particularly for first the exploration of radiation field existing thermo-element pipes may offer access to the tanks and to other interesting points without the risk of contamination. Because of their small dimension, almost no active dosimetry systems are able to measure inside the pipes. New mm-scale luminescence dosimeters in combination with a packing and transport technique are presented. The dosimeters could measure doses from 0.1 mGy up to more than 100 Gy. Hence, over the possible exposure time durations, dose rates from μGyh{sup -1} up to 1000 Gyh{sup -1} are ascertainable. For potential users the system opens the opportunity for investigation of dose rates inside of shielding and in contaminated environments. Particularly in constricted environments the technique is a unique solution for dose and dose rate measurement tasks. Within the linear dose range up to several ten Gy, the uncertainty of the results is less than 5%. 100 Gy-doses can be specified within 20%, with individual high dose calibration of the detectors even better. For WAK and other potential users the system offers the opportunity to investigate dose rates inside of shieldings and in contaminated environments. Particularly in constricted environments the technique is an unique solution for dose and dose rate measurements. (authors)
Explore the source record for details and available documents.
Explore the source record for details and available documents.
core and drilling data, hydraulic fracturing
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
No abstract prepared.
Refine your search to explore more results.