VALIDATION OF FITNESS FOR DUTY STANDARDS USING PRE- AND POST-FLIGHT CAPSULE EGRESS AND SUITED FUNCTIONAL PERFORMANCE TASKS IN SIMULATED REDUCED GRAVITY
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
As NASA prepares for exploration missions, it will be critical to understand and build upon known crew capabilities. Specifically, we need to know the functional capacities of crew at different stages of a mission and characterize these profiles so that the appropriate vehicle requirements and mission concepts of operations (ConOps) can be developed. One of the most complex phases of any missions is when there is a transition between gravity environments. For instance, both physiological adaptation to microgravity and subsequent re-entry into a gravity environment result in reduced functional capacity, even with rigorous adherence to inflight countermeasures. Quantification of the astronauts’ post-landing functional performance is necessary to design ConOps for exploration missions. Specifically, these two high-risk tasks may have to be performed soon after gravity transitions: •Unassisted capsule egress task after return to Earth •Planetary extravehicular activity (EVA) soon after landing on Mars or the Moon This study has been broken down into two phases. A pilot phase to assess the overall feasibility and demonstrate the capability to do these tasks shortly after landing and the full Egress Fitness study, which will be part of the CIPHER complement. This study uses a functional task approach to characterize performance of these high-risk tasks in long-duration ISS crewmembers before flight and shortly after return to Earth. Prior to any testing, each astronaut subject completes a suit fit check to ensure adequate sizing and mobility to be able to complete the EVA tasks. Pilot Egress Fitness pre-flight and post-flight testing includes an Earth based emergency egress out of a functional capsule mockup, and a short Mars gravity EVA simulation including suit donning, hatch egress, ladder descent, task board cable operations, baggage transfer over sand/rocky regolith, alignment with a rear entry port, and suit egress. Pre-flight testing can occur almost anytime pre-flight, but post-flight scheduling is much more critical with the capsule egress test occurring 1-4 hours after landing and the planetary EVA approximately 18-36 hours after landing. Data collected for both tasks includes task completion time, photo, and video. The EVA portion also includes collection of metabolic and heart rate. Pilot Egress Fitness study has completed baseline pre-flight testing on 3 astronaut subjects. Post-flight testing of the first two subjects will be completed in November 2021 and the final subject around March 2022. Results and lessons learned from this pilot study will inform the full Egress Fitness study, which will incorporate additional pre-flight sessions, longer EVA tasks, and post-flight testing on R+1, 4, and 7 to characterize the timeframe of recovery
The transition between gravity environments will involve one of the most complex, high-risk phases of any mission. For example, the reduced functional capacity caused by physiological deconditioning adaptations in microgravity coupled with the stressors of re-entry into partial gravity environments will increase risks to crew, even with rigorous adherence to inflight countermeasures. Quantification of the astronauts’ post-landing functional performance is necessary to design ConOps for exploration missions. Specifically, these two high-risk scenarios may be required to be performed soon after gravity transitions: • Nominal and/or emergency unassisted capsule egress task after return to Earth • Planetary extravehicular activity (EVA) soon after landing on Mars or the Moon This study is broken down into two phases. Phase 1: A feasibility study that will assess the overall feasibility and demonstrate the capability to do these tasks shortly after landing. Phase 2: the full Egress Fitness study, which is part of the CIPHER complement. This study uses a task-based approach to characterize functional performance of these high-risk scenarios in long-duration ISS crewmembers before flight and shortly after return to Earth. Prior to any testing, each astronaut subject completes a suit fit check to ensure adequate sizing and a mobility assessment to confirm completion of the EVA tasks. Pilot Egress Fitness pre-flight and post-flight testing includes an Earth-based emergency egress out of a functional capsule mockup and a short Mars gravity EVA simulation including suit donning, hatch egress, ladder descent, task board cable operations, baggage transfer over sand/rocky regolith, alignment with a rear entry port, and suit egress. Pre-flight testing will occur at any time point prior to flight. Post-flight assessment is much more critical with the capsule egress test that will occur 1–4 hours after landing and the planetary EVA approximately 18–36 hours after landing. The CIPHER study will incorporate additional pre-flight sessions, longer EVA tasks that include traverse and geology sampling, and post-flight sessions on R+1, 4, and 8 to characterize the timeframe of recovery. Data collected for both tasks include task completion time, photo, and video. The EVA portion also includes collection of metabolic and heart rate. Pilot Egress Fitness study has completed both baseline and post-flight testing on four astronaut subjects, with all four able to complete post-flight EVA testing and three able to complete postflight capsule egress testing. Preliminary results observe individual physiological variations, which were to be expected but also suggest the need to carefully track the timeline from undock to landing to testing. Furthermore, some task performance instructions and equipment may need to be adjusted to ensure results are primarily physiological. These and other lessons learned will be addressed with minor protocol changes in the full CIPHER Egress Fitness study.
Explore the source record for details and available documents.
The transition between gravity environments will involve one of the most complex, high-risk phases of exploration missions. The reduced functional capacity caused by physiological deconditioning adaptations in microgravity coupled with the stressors of re-entry into partial gravity environments will increase risks to crew, even with rigorous adherence to inflight countermeasures. Specifically, two high-risk scenarios may be required to be performed soon after gravity transitions: 1) nominal and/or emergency unassisted capsule egress task after return to Earth, and 2) planetary extravehicular activity (EVA) soon after landing on Mars or the Moon. Quantification of crewmember’s functional performance after long-duration spaceflight is necessary to inform concepts of operations for future exploration missions. The overarching aim of this study is to quantify post-landing functional performance with deconditioning after long-duration ISS missions. This study is broken down into two phases. Phase 1 includes a pilot study to assess the overall feasibility and demonstrate the capability to perform mission-like tasks shortly after landing. Phase 2, the Egress Fitness study, which is part of the Complement of Integrated Protocols for Human Exploration Research (CIPHER), uses a task-based approach to characterize functional performance in long-duration ISS crewmembers before flight and shortly after return to Earth. The pilot and full Egress Fitness study includes pre-flight and post-flight testing of simulated emergency egress out of a functional capsule mockup and a Mars gravity EVA simulation at the Active Response Gravity Offload System (ARGOS) facility. The EVA simulation tasks include suit donning, hatch egress, ladder descent, task board cable operations, baggage transfer over sand/rocky regolith, alignment with a rear entry port, and suit egress. The post-flight simulated capsule egress test occurs 1–4 h after landing and the planetary EVA simulation occurs 18–36 h after landing. The full CIPHER Egress Fitness study has additional pre-flight sessions, longer EVA tasks that include traverse and geology sampling, and post-flight sessions on R+1, 4, and 8 to characterize the timeframe of recovery. The Pilot Egress Fitness study has completed baseline and post-flight testing on four crewmembers. All subjects were able to complete the post-flight simulated planetary EVA; three subjects were able to complete the postflight capsule egress simulation. CIPHER study data collection is ongoing. This study will quantify post-landing functional performance in operationally relevant simulations to help inform future planetary concepts of operations shortly after landing.
Explore the source record for details and available documents.
Improvements to the quality of measurements in the assaying of High Specific Activity (HSA) cobalt 60 produced at the Advanced Test Reactor at the Idaho National Laboratory are presented. Such assays are conducted regularly between cycles at the ATR, and due to the radiological safety concerns, they are performed within the ATR canal. A standard ion chamber detector was placed in a collimated assay tube within the canal. Another tube, parallel to the detector, was used to position various cobalt 60 standards and targets. The collimated port between these tubes allows for the targets to be pulled across via a winch system. Previous measurements were performed at discrete 1.5-inch steps using a hand-cranked winch system. Charge was collected and integrated for 10 seconds at each discrete step during a scan. Two substantial improvements to the assay include an electronically controlled, motor-driven winch system and a software controlled continuous charge collection. Combined, these changes improved the quality of measurements as well as streamline the assay process. Further examination of these charge profiles indicated a reasonable amount of photon scattering, or shine, before a line-of-sight is established. This created inaccuracies in the reported activity of the cobalt targets. A series of MCNP-6.3 calculations were performed in an effort to quantify and correct for this shine effect. The results of the calculations and how they were employed to a create shine correction factor for the in-canal cobalt assay at the ATR are presented. The overall bias showed an overestimation of the HSA cobalt 60 activity by around 7-8%.
The International Electrotechnical Commission (IEC) is the leading and oldest global organization with over 100 years history of developing and publishing international standards for all electrical, electronic and related technologies, including radiation detection instrumentation. Subcommittee 45B 'Radiation Protection Instrumentation' of the IEC has recently started the development of two standards on radiation-generating devices. IEC 62463 'Radiation protection instrumentation--X-ray Systems for the Screening of Persons for Security and the Carrying of Illicit Items' is applicable to X-ray systems designed for screening people to detect if they are carrying objects such as weapons, explosives, chemical and biological agents and other concealed items that could be used for criminal purposes, e.g. terrorist use, drug smuggling, etc. IEC 62523 'Radiation protection instrumentation--Cargo/Vehicle radiographic inspection systems' applies to cargo/vehicle imaging inspection systems using accelerator produced X-ray or gamma radiation to obtain images of the screened objects (e.g. cargo containers, transport and passenger vehicles and railroad cars). The objective of both standards is to specify standard requirements and general characteristics and test procedures, as well as, radiation, electrical, environmental, mechanical, and safety requirements and to provide examples of acceptable methods to test these requirements. In particular the standards address the design requirements as they relate to the radiation protection of the people being screened, people who are in the vicinity of the equipment and the operators. The standard IEC 62463 does not deal with the performance requirements for the quality of the object detection. Compliance with the standards requirements will provide the manufacturers with internationally acceptable specifications and the device users with assurance of the rigorous quality and accuracy of the measurements in relation to the radiological safety of the equipment. The main characteristics of IEC 62463 and IEC 62523 standards are presented and as well as the IEC methodology of standard development and approval.
The purpose of this Cooperative Research and Development Agreement (CRADA) project is to provide the critical test data needed to qualify CF8C-Plus cast stainless steel for commercial production and use for turbocharger housings with upgraded performance and durability relative to standard commercial cast irons or stainless steels. The turbocharger technologies include, but are not limited to, heavy-duty highway diesel engines, and passenger vehicle diesel and gasoline engines. This CRADA provides additional critical high-temperature mechanical properties testing and data analysis needed to quality the new CF8C-Plus steels for turbocharger housing applications.
The Risk of Performance and Behavioral Health Decrements Due to Inadequate Cooperation, Coordination, Communication, and Psychosocial Adaptation within a Team (the Team Risk) is primarily performance-focused, with a secondary emphasis on behavioral health outcomes resulting from team performance and interpersonal interactions. Monitoring tools, measures, and countermeasures are aimed at enhancing team processes and team composition configurations to optimize team performance and functioning. Long-duration exploration missions (LDEMs) will include major challenges that could affect team performance, including social isolation, physical confinement, a small and diverse crew, communication delays between crew and ground, limited or no crew rotation or evacuation options, limited or no resupply, and a high-consequence environment. Each of these conditions will affect the crew’s coordination, cooperation, psychological well-being, and performance. Although the International Space Station (ISS) remains important for studies that require spaceflight testing and validation, the current conditions on the ISS do not adequately mimic the exploration environment that is required for National Aeronautics and Space Administration (NASA) teams research, and thus access to terrestrial or ground-based analogs of LDEM conditions is paramount. The emphasis on analogs for research is reflected in this updated evidence review of the Team Risk, and includes data from studies conducted at isolated, confined, extreme (ICE) environments (e.g., Antarctic stations), and from several mission simulation analogs such as the Human Exploration Research Analog (HERA) (HERA Experiment Information Package, 2014), also known as isolated, confined, controlled (ICC) environments. These studies have characterized many team factors regarding LDEMs, and the Team Risk has now matured from risk characterization to focusing more on countermeasure development. Because spaceflight evidence for team-level research is lacking, no reliable data is available to quantify the impact of team-level variables on individual and team-level outcomes during spaceflight missions. Until recently, no systematic attempt had been undertaken to measure the performance effects of team cohesion, team composition, team training, or team-related psychosocial adaptation during spaceflight. The Team Risk is a relatively young research area for NASA, with substantial growth only since the 2000s, and with limited access to spaceflight performance data. As a result, spaceflight evidence is lacking to identify specifically what team composition, level of training, amount of cohesion, or quality of psychosocial adaptation is necessary to reduce the risk of performance errors in space. However, astronaut journals and interviews and reports from spaceflight subject matter experts (SMEs) provide testimonies that team performance during spaceflight is important for mission success and to maintain crew health. Team spaceflight data is now being collected as part of the Spaceflight Standard Measures task (Clement, 2021)—a set of core measurements related to many human spaceflight risks that are collected from astronauts before, during, and after long-duration missions. The team-related standard measures focus on team cohesion, team performance, group living, team climate, and team processes. Collection of standard measures data is ongoing and published data is not yet available. Finally, although spaceflight evidence is lacking, evidence gleaned from ground studies and spaceflight analog studies will help close the gaps outlined in the Team Risk. Ground-based studies provide quantitative evidence for team functioning in ICE environments. Academic research on teams has produced dozens of meta-analyses that can be used to understand the general relationships among team inputs (e.g., team member characteristics and skills, job context), team processes, and emergent states (e.g., coordination, communication, cooperation, cohesion, trust, shared cognition), and team outcomes (e.g., effectiveness, errors, adaptation). Teams are complex, incorporating individual characteristics of team members, but also existing at a level that is greater than the sum of its parts. Therefore, the Team Risk must be integrated with other individual-focused NASA Human Research Program (HRP) risks, including Behavioral Medicine (BMed), Sleep, and Human-Systems Integration Architecture (HSIA), and emerging research indicates more integration may needed between the Team Risk and the physiologically oriented risks. Much of this integration occurs through the Human Systems Risk Board (HSRB). A lack of team functioning may be a stressor in some circumstances, but the team often acts as a countermeasure. For example, support for team leaders and teammates can facilitate individual functioning and encourage psychological and physically healthy behaviors and attitudes. However, more research is needed regarding teams during LDEMs and the remaining gaps in the research are described in the current report.
This design guideline describes the design criteria, calculation methods, and applicable standards recommended for use in performance and life analyses of ball and roller (rolling) bearings for yaw and pitch motion support in wind turbine applications. The formulae presented here for rolling bearing analytical methods and bearing-life ratings are consistent with methods currently used by wind turbine designers and rolling bearing manufacturers. The original yaw and pitch bearing design guideline was first drafted in 1999 by industry members and finally published in 2009 by the National Renewable Energy Laboratory. It was conceived as the third in a series of design guidelines, but it was the only one actually published by NREL and since has been known by the name "DG03." Other design guidelines were started, but instead of being published by NREL, they eventually became some of the International Electrotechnical Commission wind turbine standards in use today. This updated design guideline includes advances in research and field experiences made between 2009 and 2023. A better understanding of the operating conditions and damage mechanisms, advances in computational design, and publicly available test results facilitate more reliable yaw and pitch bearing designs.
The stark difference in clinical outcome for patients with ovarian cancer diagnosed at early stages (95% at 5 years) versus late stages (27.6% at 5 years) has driven a decades-long quest for effective biomarkers that will enable earlier detection of ovarian cancer. Yet despite intense efforts, including the application of modern high throughput technologies such as transcriptomics and proteomics, there has been little improvement in performance compared to the gold standard of quantifying serum CA125 immunoreactivity paired with transvaginal ultrasound. This review describes the strategies that have been used for identification of ovarian cancer biomarkers, including the recent introduction of novel bioinformatic approaches. Results obtained using high throughput-based vs. biologically rational approaches for the discovery of diagnostic early detection biomarkers are compared and analyzed for functional enrichment.
A search for the standard model Higgs boson is performed in 5.2 fb -1 of p$\bar{p}$ collisions at p √s = 1.96 TeV, collected with the DØ detector at the Fermilab Tevatron. The final state considered is a pair of b jets with large missing transverse energy, as expected from p$\bar{p}$→ ZH → v$\bar{v}$b$\bar{b}$ production. The search is also sensitive to the WH → ℓvb$\bar{b}$ channel, where the charged lepton is not identified. Boosted decision trees are used to discriminate signal from background. Good agreement is observed between data and expected backgrounds, and, for a Higgs-boson mass of 115 GeV, a limit is set at 95% C.L. on the cross section multiplied by branching fraction of (p$\bar{p}$ → (Z/W)H) × (H → b$\bar{b}$) that is a factor 4.57 expected and 3.73 observed larger than the value expected from the standard model.
A search for the standard model Higgs boson is performed in 6.4 fb -1 of p$\bar{p}$ collisions at √s = 1.96 TeV, collected with the DØ detector during Run II of the Fermilab Tevatron. The final state considered is a pair of jets originating from b quarks and missing transverse energy, as expected from p$\bar{p}$ → ZH → v$\bar{v}$b$\bar{b}$ production. The search is also sensitive to the WH → ℓvb$\bar{b}$ channel, where the charged lepton is not identified. Boosted decision trees are used to discriminate signal from background. Good agreement is observed between data and expected backgrounds, and a limit is set at 95% C.L. on the section multiplied by branching fraction of (p$\bar{p}$ → (Z/W)H) x (H → b$\bar{b}$). For a Higgs boson mass of 115 GeV, the observed limit is a factor of 3.5 larger than the value expected from the standard model.
Experience gained during the Apollo program demonstrated the need for extensive testing of surface systems in relevant environments, including regolith materials similar to those encountered on the lunar surface. As NASA embarks on a return to the Moon, it is clear that the current lunar sample inventory is not only insufficient to support lunar surface technology and system development, but its scientific value is too great to be consumed by destructive studies. Every effort must be made to utilize standard simulant materials, which will allow developers to reduce the cost, development, and operational risks to surface systems. The Lunar Regolith Simulant Materials Workshop held in Huntsville, AL, on January 24 26, 2005, identified the need for widely accepted standard reference lunar simulant materials to perform research and development of technologies required for lunar operations. The workshop also established a need for a common, traceable, and repeatable process regarding the standardization, characterization, and distribution of lunar simulants. This document presents recommendations for the standardization, production and usage of lunar regolith simulant materials.
Determining Confounding Sensitivities In Eddy Current Thin Film Measurements Ethan Gros, Lalita Udpa, Electrical Engineering, Michigan State University, East Lansing MI 48824 James A. Smith, Experiment Analysis, Idaho National Laboratory, Idaho Falls ID 83415 Eddy current (EC) techniques are widely used in industry to measure the thickness of non-conductive films on a metal substrate. This is done using a system whereby a coil carrying a high-frequency alternating current is used to create an alternating magnetic field at the surface of the instrument's probe. When the probe is brought near a conductive surface, the alternating magnetic field will induce ECs in the conductor. The substrate characteristics and the distance of the probe from the substrate (the coating thickness) affect the magnitude of the ECs. The induced currents load the probe coil affecting the terminal impedance of the coil. The measured probe impedance is related to the lift off between coil and conductor as well as conductivity of the test sample. For a known conductivity sample, the probe impedance can be converted into an equivalent film thickness value. The EC measurement can be confounded by a number of measurement parameters. It is the goal of this research to determine which physical properties of the measurement set-up and sample can adversely affect the thickness measurement. The eddy current testing is performed using a commercially available, hand held eddy current probe (ETA3.3H spring loaded eddy probe running at 8 MHz) that comes with a stand to hold the probe. The stand holds the probe and adjusts the probe on the z-axis to help position the probe in the correct area as well as make precise measurements. The signal from the probe is sent to a hand held readout, where the results are recorded directly in terms of liftoff or film thickness. Understanding the effect of certain factors on the measurements of film thickness, will help to evaluate how accurate the ETA3.3H spring loaded eddy probe is at measuring film thickness under varying experimental conditions. This research will study the effects of a number of factors such as i) calibration, ii) conductivity, iii) edge effect, iv) surface finish of base material and v) cable condition and compare with the long term reproducibility of a standard measurement. This work was performed with support from the Department of Energy under the United States National Nuclear Security Administration (NNSA) at the Idaho National Laboratory.
Occupant concern about indoor air quality (IAQ) issues has led to the increased use of more effective air filters in residential heating and cooling systems. This study performed measurements in ten California houses to determine the effects of changing filter performance and related characteristics on the energy use of the heating and cooling systems. Multiple filters were evaluated covering a wide range of filter effectiveness from simple low filtration fiberglass filters up to high efficiency filters that might be used by occupants concerned about IAQ. Sophisticated analysis and simulation tools used the field-testing results to determine filter impacts for a wide range of parameters and California climates. The results indicate that for MERV 10/11/13 filters the effects on energy use are moderate (<5%) over a wide range of performance conditions and climates. Using higher MERV 16 filters can lead to significantly increased energy use (>5%). The high airflow resistance of MERV 16 filters led to excess noise in some test houses from air bypassing the filter and the blower motor. Filter loading rates varied more from house to house than by MERV rating and overall were quite low in many of the homes. Filter related energy use does not need to be addressed for filters of MERV 10/11/13 and MERV 16 filters should only be used with low leakage tested ducts unless the filter is mounted at the blower compartment. MERV 16 filters should only be used if the filter area is sufficient to prevent noise issues and if the duct system has low air flow resistance and low leakage. Filters should be labeled for their air flow resistance, or static pressure at a particular flow rate, that would allow codes and standards to reference a particular performance specification and allow contractors and homeowners to make informed purchases.
Rectangular-waveguide inserts that are made of non-ferromagnetic metals and are sized and shaped to function as notch filters have been conceived as reference standards for use in the rectangular- waveguide method of characterizing materials with respect to such constitutive electromagnetic properties as permittivity and permeability. Such standards are needed for determining the accuracy of measurements used in the method, as described below. In this method, a specimen of a material to be characterized is cut to a prescribed size and shape and inserted in a rectangular- waveguide test fixture, wherein the specimen is irradiated with a known source signal and detectors are used to measure the signals reflected by, and transmitted through, the specimen. Scattering parameters [also known as "S" parameters (S11, S12, S21, and S22)] are computed from ratios between the transmitted and reflected signals and the source signal. Then the permeability and permittivity of the specimen material are derived from the scattering parameters. Theoretically, the technique for calculating the permeability and permittivity from the scattering parameters is exact, but the accuracy of the results depends on the accuracy of the measurements from which the scattering parameters are obtained. To determine whether the measurements are accurate, it is necessary to perform comparable measurements on reference standards, which are essentially specimens that have known scattering parameters. To be most useful, reference standards should provide the full range of scattering-parameter values that can be obtained from material specimens. Specifically, measurements of the backscattering parameter (S11) from no reflection to total reflection and of the forward-transmission parameter (S21) from no transmission to total transmission are needed. A reference standard that functions as a notch (band-stop) filter can satisfy this need because as the signal frequency is varied across the frequency range for which the filter is designed, the scattering parameters vary over the ranges of values between the extremes of total reflection and total transmission. A notch-filter reference standard in the form of a rectangular-waveguide insert that has a size and shape similar to that of a material specimen is advantageous because the measurement configuration used for the reference standard can be the same as that for a material specimen. Typically a specimen is a block of material that fills a waveguide cross-section but occupies only a small fraction of the length of the waveguide. A reference standard of the present type (see figure) is a metal block that fills part of a waveguide cross section and contains a slot, the long dimension of which can be chosen to tailor the notch frequency to a desired value. The scattering parameters and notch frequency can be estimated with high accuracy by use of commercially available electromagnetic-field-simulating software. The block can be fabricated to the requisite precision by wire electrical-discharge machining. In use, the accuracy of measurements is determined by comparison of (1) the scattering parameters calculated from the measurements with (2) the scattering parameters calculated by the aforementioned software.
Refine your search to explore more results.