Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Guide to using Multiple Regression in Excel (MRCX v.1.1) for Removal of River Stage Effects from Well Water Levels

A software tool was created in Fiscal Year 2010 (FY11) that enables multiple-regression correction of well water levels for river-stage effects. This task was conducted as part of the Remediation Science and Technology project of CH2MHILL Plateau Remediation Company (CHPRC). This document contains an overview of the correction methodology and a user’s manual for Multiple Regression in Excel (MRCX) v.1.1. It also contains a step-by-step tutorial that shows users how to use MRCX to correct river effects in two different wells. This report is accompanied by an enclosed CD that contains the MRCX installer application and files used in the tutorial exercises.

99 GENERAL AND MISCELLANEOUS↗

Instability Control in a Staged Z-pinch

A \Staged Z-Pinch is a fusion-energy concept in which stored-electric energy is first converted into plasma-liner-kinetic energy, and then transferred to a coaxialtarget plasma [H. U. Rahman, F. J. Wessel, and N. Rostoker, Phys. Rev. Lett. 74, p. 714(1996)]. Proper choice of the liner and target materials, and their initial radii and mass densities, leads to dynamic stabilization, current amplification, and shock heating of the target. Simulations suggest that this configuration has merit as a alternative inertial-confinement-fusion concept, and may provide an energy release exceeding thermonuclear break-even, if tested on one of many newer pulsed power systems, for example those located at Sandia National Laboratories.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Staged, High-Pressure Oxy-Combustion Technology: Development and Scale-Up

The immediate need for a high efficiency, low cost carbon capture process has prompted the recent development of pressurized oxy-combustion. With a greater combustion pressure the dew point of the flue gas is increased, allowing for effective integration of the latent heat of flue gas moisture into the Rankine cycle. This increases the net plant efficiency and reduces costs. A novel, transformational process, named Staged, Pressurized Oxy-Combustion (SPOC), achieves additional step changes in efficiency and cost reduction by significantly reducing the recycle of flue gas. The research and development activities conducted under Phases I and II of this project (FE0009702) include: SPOC power plant cost and performance modeling, CFD-assisted design of pressurized SPOC boilers, theoretical analysis of radiant heat transfer and ash deposition, boiler materials corrosion testing, construction of a 100 kWth POC test facility, and experimental testing. The results of this project have advanced the technology readiness level (TRL) of the SPOC technology from 1 to 5.

01 COAL, LIGNITE, AND PEAT↗

High Temperature, High AN2 Last Stage Blade for 65% Efficiency Phase I (Final Report)

GE Power (GEP), in partnership with GE Global Research (GEGR)(GEP and GEGR are divisions of General Electric Company) developed hot and large Last Stage Blade (LSB) technologies necessary for state-of-the art gas turbines to successfully realize ~3100°F turbine inlet temperatures (TIT), an essential element to reaching the DOE goal of 65% combined cycle efficiency (CCeff). The objective of this project was to develop conceptual LSB designs and advance the technological understanding of synchronous vibrations (SV), nonsynchronous vibrations (NSV), and damping that limit the current state-of-the-art LSB designs and applications. In the Phase I project GE Power leveraged existing design and analysis knowledge and techniques for LSB design and performed extensive analytical evaluations to identify and characterize conceptual design concepts.

20 FOSSIL-FUELED POWER PLANTS↗

The Integrity of ACSR Full Tension Single-Stage Splice Connector at Higher Operation Temperature

Due to increases in power demand and limited investment in new infrastructure, existing overhead power transmission lines often need to operate at temperatures higher than those used for the original design criteria. This has led to the accelerated aging and degradation of splice connectors. It is manifested by the formation of hot-spots that have been revealed by infrared imaging during inspection. The implications of connector aging is two-fold: (1) significant increases in resistivity of the splice connector (i.e., less efficient transmission of electricity) and (2) significant reductions in the connector clamping strength, which could ultimately result in separation of the power transmission line at the joint. Therefore, the splice connector appears to be the weakest link in electric power transmission lines. This report presents a protocol for integrating analytical and experimental approaches to evaluate the integrity of full tension single-stage splice connector assemblies and the associated effective lifetime at high operating temperature.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Refine your search to explore more results.