A nanoscale soft-ionization membrane: a novel ionizer for ion mobility spectrometers for space applications
In this paper we focus our attention on ion mobility spectrometers (IMSs) as a potential candidate to be incorporated with SIM.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
In this paper we focus our attention on ion mobility spectrometers (IMSs) as a potential candidate to be incorporated with SIM.
A miniature quadrupole mass spectrometer array and gas chromatograph have been designed and built for NASA flight missions.
Two simple and compact pushbroom spectrometer forms are described that can satisfy stringent spectral and spatial uniformity requirements in terms of minimizing distortion as well as the variation of the pixel spectral and spatial response functions.
The computed-tomography imaging spectrometer (CTIS) captures a scene's spatial and spectral information without any type of scanning.
A single optical element capable of both wavelength dispersion and imaging would be useful for implementing compact imaging spectrometers.
The status of the Airborne Visible and Infrared Imaging Spectrometer (AVIRIS) is reported at the beginning of the current flight season. Sensor performance based on laboratory measurements and trend data as well as a review of end of 1995 season performance is given as a measure of expected performance during the 1996 season which began in March of 1996. Recent improvements to the sensor's internal calibration source and measurements of instrument parameters are described. The effects of these enhancements on the reported data are also discussed along with and update onflight schedules and plans for 1996 flight operations.
The Mars Pathfinder mission promises to reap a harvest of geological information about Mars. One of the nearly half dozen instruments making this science data possible is the alpha proton X ray spectrometer (APXS). Using a curium source and backscattering techniques, the APXS will determine the elemental composition of rocks and the soil around the landing site. To ensure information of high fidelity, the APXS sensor face must be aligned to within 20° to the surface of each rock and soil sampling location and be held there for up to 10 hours. This is accomplished through the anthropomorphic deployment mechanism (ADM). The ADM mounts on the back of the Mars rover. Working with the rover, the ADM both actively and passively positions the APXS sensor head against a chosen target. The ADM is an amalgamation of unique solutions to some very challenging design problems. The resulting design is light, flexible, and nearly autonomous. Its straightforward operation rivals that of the human arm in simplicity and elegance.
From the Introduction: AVIRIS is a NASA-sponsored Earth-looking imaging spectrometer designed, built and operated by the Jet Propulsion Laboratory. Improvements to AVIRIS prior to 1992 have been described previously. In this paper we describe recent and planned improvements to AVIRIS in the sensor task.
In this paper, we describe an experiment to calibrate the Optical Sensor on board the Japanese Earth Resources Satellite-1 with data acquired by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS). This experiment establishes the suitability of AVIRIS for the calibration of spaceborne sensors in the 400 to 2500 nm spectral region.
The Planetary Integrated Camera-Spectrometer (PICS)is an highly integrated sensor system which performs the functions of three optical instruments:...
A miniature quadrupole mass spectrometer array has been designed and tested. It consists of 16 rods in a 4x4 array.
CMOS Charged Particle Spectrometer chips [1], designated CPS32, have been developed for an experiment on the STRV-2 spacecraft. These chips, which are a form of Active Pixel Sensor (APS), were designed for proton and electron energy spectrometry.
A first-generation CMOS Charged Particle Spectrometer chip [1] was designed at JPL for flight on the STRV-2 spacecraft. These devices will collect electron and proton spectra in low Earth orbit as part of an experiment to demonstrate Active Pixel Sensor (APS) technology in space. This paper presents the results of total dose testing on these chips and, where possible, attempts to extend the results to other Active Pixel Sensors.
In 1996 and 1997 the Galileo Ultraviolet Spectrometer (UVS) obtained the first measurements of Jupiter's nightside midultraviolet (MUV) polar auroral spectrum from 1620 to 3231 A at 13 A resolution.
A fine resolution chopper spectrometer (SEQUOIA) recently received first neutronsat the SNS. The commissioning phase of the instrument is underway. SEQUOIA is designedto utilize neutrons of an incident energy (Ei) between 10-2000 meV. A monochromatic beamis provided on a sample, 20 m from the decoupled ambient temperature H2O moderator, byfiltering the white beam with a Fermi chopper located 18 m from the source. After interactingwith the sample, neutrons are detected by an array of 3He linear position sensitive tubes locatedon a vertical cylinder with a radius of 5.5 m. This contribution presents current results from thecommissioning experiments and compares SEQUOIA’s actual and predicted performance. Thesecommissioning experiments include characterization of the beam by monitors, determination ofthe chopper phase offsets, and runs with V and C4H2I2S. The predicted performance is providedby analytical calculations and Monte Carlo simulations.
A significant part of the experimental program in Hall-B of the Jefferson Lab is dedicated to the studies of the structure of baryons. CEBAF Large Acceptance Spectrometer (CLAS), availability of circularly and linearly polarized photon beams and recent addition of polarized targets provides remarkable opportunity for single, double and in some cases triple polarization measurements in photoproduction. An overview of the experiments will be presented.
A Lead Slowing Down Spectrometer (LSDS) provides a high neutron flux environment that enables measurements of small samples ({approx}{mu}g) or samples with small cross sections (tens of {mu}b). The LSDS at Rensselaer Polytechnic Institute (RPI) was previously used for fission cross section measurements and for studies of methods for assay of used nuclear fuel. The effective energy range for the LSDS is 0.1 eV to 10 keV with energy resolution of about 35%. Two new LSDS applications were recently developed at RPI; the first enables simultaneous measurements of the fission cross section and fission fragment mass and energy distributions as a function of the incident neutron energy. The second enables measurements of the (n,{alpha}) and (n; p) cross sections for materials with a positive Q value for these reactions. Fission measurements of {sup 252}Cf, {sup 235}U, and {sup 239}Pu were completed and provide information on fission fragment and energy distributions in resonance clusters. Measurements of the (n,{alpha}) cross section for {sup 147,149}Sm were completed and compared to previously measured data. The new data indicate that the existing evaluations need to be adjusted.
We discuss current progress and future plans for the general antiparticle spectrometer experiment (GAPS). GAPS detects antideuterons through the X-rays and pions emitted during the deexcitation of exotic atoms formed when the antideuterons are slowed down and stopped in targets. GAPS provides an exceptionally sensitive means to detect cosmic-ray antideuterons. Cosmic-ray antideuterons can provide indirect evidence for the existence of dark matter in such form as neutralinos or Kaluza-Klein particles. We describe results of accelerator testing of GAPS prototypes, tentative design concepts for a flight GAPS detector, and near-term plans for flying a GAPS prototype on a balloon.
Refine your search to explore more results.