At least 1,801 records · Page 100

Microwave cavity search for paraphotons

In this proceeding we report the first results of a microwave cavity search for hidden sector photons. Using a pair of isolated resonant cavities we look for 'light shining through a wall' from photon--hidden sector photon oscillations. Our prototype experiment consists of two cylindrical, copper cavities stacked axially inside a single vacuum chamber. At a hidden sector photon mass of 39.58 mueV we place an upper limit on the kinetic mixing parameter chi at 7.8x10{sup -6}. Whilst this result is inside already established limits our experiment has great scope for improvement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of a linear device developed for research on advanced plasma imaging and dynamics

Within the scope of long term research on imaging diagnostics for steady-state plasmas and understanding of edge plasma physics through diagnostics with conventional spectroscopic methods, we have constructed a linear electron cyclotron resonance (ECR) plasma device named Research on Advanced Plasma Imaging and Dynamics (RAPID). It has a variety of axial magnetic field profiles provided by eight water-cooled magnetic coils and two dc power supplies. The positions of the magnetic coils are freely adjustable along the axial direction and the power supplies can be operated with many combinations of electrical wiring to the coils. Here, a 6 kW 2.45 GHz magnetron is used to produce steady-state hydrogen, helium, and argon plasmas with central magnetic fields of 875 and/or 437.5 G (second harmonic). In order to achieve the highest possible plasma performance within the limited input parameters, wall conditioning experiments were carried out. Chamber bake-out was achieved with heating coils that were wound covering the vessel, and long-pulse electron cyclotron heating discharge cleaning was also followed after 4 days of bake-out. A uniform bake-out temperature (150 deg. C) was achieved by wrapping the vessel in high temperature thermal insulation textile and by controlling the heating coil current using a digital control system. The partial pressure changes were observed using a residual gas analyzer, and a total system pressure of 5x10{sup -8} Torr was finally reached. Diagnostic systems including a millimeter-wave interferometer, a high resolution survey spectrometer, a Langmuir probe, and an ultrasoft x-ray detector were used to provide the evidence that the plasma performance was improved as we desired. In this work, we present characterization of the RAPID device for various system conditions and configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ID-SERS Based Reference Method for Quantification of Large Biomolecules on a Single Chip

Accuracy and precision of quantitative SERS results have been significantly increased by applying a method based on the so-called isotope-dilution (ID) principle. In this ID-SERS approach, an isotopically labeled analogue of the target molecule (isotopologue) is spiked to the sample at a known concentration. Due to the slight difference in their molar masses, some Raman bands of the heavier isotopologue are red-shifted with respect to the same signals resulting from the unlabelled compound. As a result, spectra evaluation is reduced to the determination of intensity ratios rather than absolute intensities, and the unknown quantity of the analyte can be calculated from the known quantity of the standard. This procedure is of particular interest in the development of highly accurate reference procedures for metrology in chemistry. Because the sample is spiked prior to any further treatment, potential loss of material or matrix effects would equally affect both isotopologues, without influencing the final result. The method has been successfully applied for quantifying small diagnostic marker molecules like creatinine at their relevant serum concentration levels using silver colloids as SERS substrates. Now, the ID-SERS approach has been realized as a 'one-chip' approach using 'Bio-chips' made of intrinsically grown spherical silver nanoparticles with gaps less than 10 nm in between (Fig. 1). In addition, the scope of the method has been extended to larger biomolecules like peptides which will be shown using the example of the human growth-hormone (hGH) peptide T12 at physiologically relevant serum concentration levels (Fig. 2). Further developments towards the quantification of full proteins will also be reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Modeling CO{sub 2} Laser Ablative Impulse with Polymers

Laser ablation vaporization models have usually ignored the spatial dependence of the laser beam. Here, we consider effects from modeling using a Gaussian beam for both photochemical and photothermal conditions. The modeling results are compared to experimental and literature data for CO{sub 2} laser ablation of the polymer polyoxymethylene under vacuum, and discussed in terms of the ablated mass areal density and momentum coupling coefficient. Extending the scope of discussion, laser ablative impulse generation research has lacked a cohesive strategy for linking the vaporization and plasma regimes. Existing models, mostly formulated for ultraviolet laser systems or metal targets, appear to be inappropriate or impractical for applications requiring CO{sub 2} laser ablation of polymers. A recently proposed method for linking the vaporization and plasma regimes for analytical modeling is addressed here along with the implications of its use. Key control parameters are considered, along with the major propulsion parameters needed for laser ablation propulsion modeling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Refactoring and Its Benefits

Refactoring is a disciplined technique for restructuring an existing body of code, altering its internal structure without changing its external behavior. It improves internal code structure without altering its external functionality by transforming functions and rethinking algorithms. It is an iterative process. Refactoring include reducing scope, replacing complex instructions with simpler or built-in instructions, and combining multiple statements into one statement. By transforming the code with refactoring techniques it will be faster to change, execute, and download. It is an excellent best practice to adopt for programmers wanting to improve their productivity. Refactoring is similar to things like performance optimizations, which are also behavior- preserving transformations. It also helps us find bugs when we are trying to fix a bug in difficult-to-understand code. By cleaning things up, we make it easier to expose the bug. Refactoring improves the quality of application design and implementation. In general, three cases concerning refactoring. Iterative refactoring, Refactoring when is necessary, Not refactor.Mr. Martin Fowler identifies four key reasons to refractor. Refactoring improves the design of software, makes software easier to understand, helps us find bugs and also helps in executing the program faster. There is an additional benefit of refactoring. It changes the way a developer thinks about the implementation when not refactoring. There are the three types of refactorings. 1) Code refactoring: It often referred to simply as refactoring. This is the refactoring of programming source code. 2) Database refactoring: It is a simple change to a database schema that improves its design while retaining both its behavioral and informational semantics. 3) User interface (UI) refactoring: It is a simple change to the UI which retains its semantics. Finally, we conclude the benefits of Refactoring are: Improves the design of software, Makes software easier to understand, Software gets cleaned up and Helps us to find bugs and Helps us to program faster.

99 GENERAL AND MISCELLANEOUS↗

Preface to ISIF 2009 special issue of Journal of Applied Physics : science and technology of integrated functionalities.

The science and technology of ferroelectric thin films and their applications have attracted many researchers and experienced tremendous progress in the past 20 years. The recent worldwide increase in commercial applications of ferroelectric devices such as smart cards based on nonvolatile ferroelectric random access memories is a symbol of both the maturity and the acceptance of the technology. The 21st International Symposium on Integrated Ferroelectrics (ISIF 2009), held on September 22 to October 2, 2009 in Colorado Springs, CO, provided a forum for the academic and national laboratories research community and industry to present and share their new findings, achievements, and opinions on integrated ferroelectrics and their applications. The International Symposium on Integrated Ferroelectrics hosted the ISIF 2009. This was the first year where the ISIF held the conference in its new format under the name of International Symposium on Integrated Functionalities. The General Chairs of the ISIF in consultation with the Advisory Board and the ISIF community decided to revise the focus of the conference in order to broaden the scope to the science and technology of multifunctional materials and devices. This decision was taken in view that a new paradigm in materials, materials integration, and devices is emerging with a view to the development of a new generation of micro- and nanoscale multifunctional devices. The program included three plenary presentations on diverse topics such as 'The Role of Nonvolatile Memory in Ubiquitous Computing,' 'Ferroelectrics and High Density Memory Technology,' 'Nanoscale Ferroelectrics and Interfaces: Size Effects,' four tutorial lectures on diverse topics, such as 'Magnetic Memory Applications,' 'Ferroelectrics and Ferroelectric Devices,' 'Challenges for High-K Dielectrics on High Mobility Channels,' 'Solar Cell Materials,' one poster session, and eight oral sessions. Thanks to the great efforts made by the ISIF organization committee and the session chairs, the conference successfully achieved its objectives and the work presented reflected very well the most recent advances of integrated ferroelectrics and their applications, as well as advances in other areas related to the new theme of Integrated Functionalities. Many aspects of ferroelectric, piezoelectric, high-K dielectric, magnetic, and phase change materials, including the science and technology of these materials in thin film form, integration with other thin film materials (metals or oxide electrodes), and fabrication of micro- and nanostructures based on these heterostructure layers, and device architecture and physics, were addressed from the experimental point of view. Work on theory and computer simulations of the mentioned materials and devices were discussed also with a view to the promising applications to multifunctional devices. In addition, the ISIF 2009 featured discussions of alternative nonvolatile memory concepts and materials, such as phase change memories, research on multiferroics and magnetoelectric materials, ferroelectric photovoltaics, and new directions on the science of perovskites such as biomolecular/polarizable interfaces, and bio-ferroelectric and other oxide interfaces. Following the standard submission and peer review process of Journal of Applied Physics, the selected papers presented in ISIF 2009 in Colorado Springs are published in this special issue. We believe that the papers in this special issue represent the forefront contributions to ISIF 2009 in the various areas of fundamental and applied science of integrated ferroelectrics and functionalities and their applications. We would like to take this opportunity to thank the following organizations and companies for their support and sponsorship for ISIF 2009, namely: Aixact Systems GMBH, Radiant Technologies, Symetrix Corporation, and Taylor and Francis Publishers. We would also like to thank the conference and session chairs, advisory and organizing committee members for their hard work that resulted in a very successful ISIF 2009, now in its new future-looking modality of Integrated Functionalities.

36 MATERIALS SCIENCE↗

Atomic Data and Modelling for Fusion: the ADAS Project

The paper is an update on the Atomic Data and Analysis Structure, ADAS, since ICAM-DATA06 and a forward look to its evolution in the next five years. ADAS is an international project supporting principally magnetic confinement fusion research. It has participant laboratories throughout the world, including ITER and all its partner countries. In parallel with ADAS, the ADAS-EU Project provides enhanced support for fusion research at Associated Laboratories and Universities in Europe and ITER. OPEN-ADAS, sponsored jointly by the ADAS Project and IAEA, is the mechanism for open access to principal ADAS atomic data classes and facilitating software for their use. EXTENDED-ADAS comprises a variety of special, integrated application software, beyond the purely atomic bounds of ADAS, tuned closely to specific diagnostic analyses and plasma models.The current scientific content and scope of these various ADAS and ADAS related activities are briefly reviewed. These span a number of themes including heavy element spectroscopy and models, charge exchange spectroscopy, beam emission spectroscopy and special features which provide a broad baseline of atomic modelling and support. Emphasis will be placed on 'lifting the fundamental data baseline'--a principal ADAS task for the next few years. This will include discussion of ADAS and ADAS-EU coordinated and shared activities and some of the methods being exploited.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Atomic and Molecular Data Needs for Radiation Damage Modeling: Multiscale Approach

We present a brief overview of the multiscale approach towards understanding of the processes responsible for the radiation damage caused by energetic ions. This knowledge is very important, because it can be utilized in the ion-beam cancer therapy, which is one of the most advanced modern techniques to cure certain type of cancer. The central element of the multiscale approach is the theoretical evaluation and quantification of the DNA damage within cell environment. To achieve this goal one needs a significant amount of data on various atomic and molecular processes involved into the cascade of events starting with the ion entering and propagation in the biological medium and resulting in the DNA damage. The discussion of the follow up biological processes are beyond the scope of this brief overview. We consider different paths of the DNA damage and focus on the the illustration of the thermo-mechanical effects caused by the propagation of ions through the biological environment and in particular on the possibility of the creation of the shock waves in the vicinity of the ion tracks. We demonstrate that at the initial stages after ion's passage the shock wave is so strong that it can contribute to the DNA damage due to large pressure gradients developed at the distances of a few nanometers from the ionic tracks. This novel mechanism of the DNA damage provides an important contribution to the cumulative biodamage caused by low-energy secondary electrons, holes and free radicals.

36 MATERIALS SCIENCE↗

X-Rays Compton Detectors For Biomedical Application

Collimators are usually needed to image sources emitting X-rays that cannot be focused. Alternately, one may employ a Compton Camera (CC) and measure the direction of the incident X-ray by letting it interact with a thin solid, liquid or gaseous material (Tracker) and determine the scattering angle. With respect to collimated cameras, CCs allow higher gamma-ray efficiency in spite of lighter geometry, and may feature comparable spatial resolution. CCs are better when the X-ray energy is high and small setups are required. We review current applications of CCs to Gamma Ray Astronomy and Biomedical systems stressing advantages and drawbacks. As an example, we focus on a particular CC we are developing, which is designed to image small animals administered with marked pharmaceuticals, and assess the bio-distribution and targeting capability of these latter. This camera has to address some requirements: relatively high activity of the imaged objects; detection of gamma-rays of different energies that may range from 140 keV (Tc99m) to 511 keV; presence of gamma and beta radiation with energies up to 2 MeV in case of 188Re. The camera consists of a thin position-sensitive Silicon Drift Detector as Tracker, and a further downstream position-sensitive system employing scintillating crystals and a multi-anode photo-multiplier (Calorimeter). The choice of crystal, pixel size, and detector geometry has been driven by measurements and simulations with the tracking code GEANT4. Spatial resolution, efficiency and scope are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research into Oil-based Colloidal-Graphite Lubricants for Forging of Al-based Alloys

The presented paper describes the topical problem in metal forging production. It deals with the choice of an optimal lubricant for forging of Al-based alloys. Within the scope of the paper, the properties of several oil-based colloidal-graphite lubricants were investigated. The physicochemical and technological properties of these lubricants are presented. It was found that physicochemical properties of lubricant compositions have an influence on friction coefficient value and quality of forgings.The ring compression method was used to estimate the friction coefficient value. Hydraulic press was used for the test. The comparative analysis of the investigated lubricants was carried out. The forging quality was estimated on the basis of production test. The practical recommendations were given to choose an optimal oil-based colloidal-graphite lubricant for isothermal forging of Al-based alloy.

36 MATERIALS SCIENCE↗

Cold atmospheric pressure plasma jets as sources of singlet delta oxygen for biomedical applications

Absolute densities of singlet delta oxygen (SDO) molecules were measured using infrared optical emission spectroscopy in the flowing effluents of two different atmospheric-pressure plasma jets (APPJs): a capacitively coupled radio-frequency-driven jet (rf-APPJ) and a lower frequency kilohertz-driven dielectric barrier discharge jet. The plasma jets were operated in helium, with small admixtures of molecular oxygen (O{sub 2} < 2%). High absolute SDO densities of up to 6.2 x 10{sup 15} cm{sup -3} were measured at approximately 10 cm downstream. The rf-APPJ seems to be much more efficient in producing SDO. The influence of different parameters, such as gas flows and mixtures and power coupled to the plasmas, on the production of SDO by the two APPJs has been investigated. Despite the considerable differences between the two plasma jets (excitation frequency, electric field direction, inter-electrode distance, plasma propagation), similar dependencies on the oxygen admixture and on the dissipated power were found in both APPJs. However, opposite trends were observed for the gas flow dependence. The results presented in this paper show that the control of the external operating conditions of each APPJ enables the tailoring of the SDO composition of both plasma effluents. This provides scope to tune the plasma jets for desired applications, e.g., in biomedicine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A spectroscopic ellispometric study of the tunability of the optical constants and thickness of GeO{sub x} films with swift heavy ions

Sub-stoichiometric GeO{sub x} films were fabricated by electron-beam evaporation method. The films were irradiated with 100 MeV Ag{sup 7+} ions at fluences between 1 x 10{sup 12} and 1 x 10{sup 14} ions-cm{sup -2}. Spectroscopic ellipsometric measurements were performed in air at room temperature. The values of the layer thickness and refractive index were extracted from ellipsometry using a multilayer analysis and the Tauc Lorentz model. The refractive index (at 633 nm) of the as-deposited GeO{sub x} film was estimated to be 1.860 and decreased to 1.823 for films irradiated at an ion fluence of 1 x 10{sup 14} ions-cm{sup -2}. The thickness of the films also decreased after irradiation and is due to a sputtering induced by the ion beam. The change in the refractive index with ion fluence is attributed to a stoichiometric change and structural transformation represented by GeO{sub x}{yields} Ge + GeO{sub y} (y > x) occurring due to a thermal spike induced by ion irradiation. Swift heavy ions thus provide a scope for modulating the refractive index of GeO{sub x} films. The thickness and stoichiometric changes are supported by Rutherford backscattering measurements.

36 MATERIALS SCIENCE↗

Effect of Sintering Temperature on Dielectric Properties of Iron Deficient Nickel-Ferrite

Nickel Ferrite among all the magneto ceramic materials have been studied very much due to its large number of applications. But there is a large scope of modification of its properties. Thus people still working on it for improvisation of its properties via compositional and structural modifications. Present paper reporting the preparation and characterization of iron deficient Nickel ferrite for different sintering temperature. Ferrite samples having the general formula NiFe1.98O{sub 4} were prepared using the standard ceramic method. The phase formation was confirmed by X-ray diffraction technique. The effect of sintering temperature on the electrical properties and resistivity was studied. The data shows that dielectric properties are highly dependent on the sintering temperature.

36 MATERIALS SCIENCE↗

A review of ion sources for medical accelerators (invited)

There are two major medical applications of ion accelerators. One is a production of short-lived isotopes for radionuclide imaging with positron emission tomography and single photon emission computer tomography. Generally, a combination of a source for negative ions (usually H- and/or D-) and a cyclotron is used; this system is well established and distributed over the world. Other important medical application is charged-particle radiotherapy, where the accelerated ion beam itself is being used for patient treatment. Two distinctly different methods are being applied: either with protons or with heavy-ions (mostly carbon ions). Proton radiotherapy for deep-seated tumors has become widespread since the 1990s. The energy and intensity are typically over 200 MeV and several 10{sup 10} pps, respectively. Cyclotrons as well as synchrotrons are utilized. The ion source for the cyclotron is generally similar to the type for production of radioisotopes. For a synchrotron, one applies a positive ion source in combination with an injector linac. Carbon ion radiotherapy awakens a worldwide interest. About 6000 cancer patients have already been treated with carbon beams from the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan. These clinical results have clearly verified the advantages of carbon ions. Heidelberg Ion Therapy Center and Gunma University Heavy Ion Medical Center have been successfully launched. Several new facilities are under commissioning or construction. The beam energy is adjusted to the depth of tumors. It is usually between 140 and 430 MeV/u. Although the beam intensity depends on the irradiation method, it is typically several 10{sup 8} or 10{sup 9} pps. Synchrotrons are only utilized for carbon ion radiotherapy. An ECR ion source supplies multi-charged carbon ions for this requirement. Some other medical applications with ion beams attract developer's interests. For example, the several types of accelerators are under development for the boron neutron capture therapy. This treatment is conventionally demonstrated by a nuclear reactor, but it is strongly expected to replace the reactor by the accelerator. We report status of ion source for medical application and such scope for further developments.

43 PARTICLE ACCELERATORS↗

Modelling spectral emission from fusion plasmas

The paper is a tribute to Nicol Peacock and has a focus on interests and developments at Culham Laboratory from {approx} 1970 when Nicol led the UKAEA spectroscopy team. The paper charts a little of the evolution of these models and their data through the seventies and eighties on into this century at Culham. The paper concludes with the state of efforts to enable easy, universal access to spectral analysis across the scope of Culham activity, of which it is hoped Nicol would approve.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Possibility for ultra-bright electron beam acceleration in dielectric wakefield accelerators

We describe a conceptual proposal to combine the Dielectric Wakefield Accelerator (DWA) with the Emittance Exchanger (EEX) to demonstrate a high-brightness DWA with a gradient of above 100 MV/m and less than 0.1% induced energy spread in the accelerated beam. We currently evaluate the DWA concept as a performance upgrade for the future LANL signature facility MaRIE with the goal of significantly reducing the electron beam energy spread. The preconceptual design for MaRIE is underway at LANL, with the design of the electron linear accelerator being one of the main research goals. Although generally the baseline design needs to be conservative and rely on existing technology, any future upgrade would immediately call for looking into the advanced accelerator concepts capable of boosting the electron beam energy up by a few GeV in a very short distance without degrading the beam's quality. Scoping studies have identified large induced energy spreads as the major cause of beam quality degradation in high-gradient advanced accelerators for free-electron lasers. We describe simulations demonstrating that trapezoidal bunch shapes can be used in a DWA to greatly reduce the induced beam energy spread, and, in doing so, also preserve the beam brightness at levels never previously achieved. This concept has the potential to advance DWA technology to a level that would make it suitable for the upgrades of the proposed Los Alamos MaRIE signature facility.

43 PARTICLE ACCELERATORS↗

New International Program to Asses the Reliability of Emerging Nondestructive Techniques (PARENT)

The Nuclear Regulatory Commission (NRC) established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) to follow on from the successful Program for the Inspection of Nickel alloy Components (PINC). The goal of the PARENT is to conduct a confirmatory assessment of the reliability of nondestructive evaluation (NDE) techniques for detecting and sizing primary water stress corrosion cracks (PWSCC) and applying the lessons learned from PINC to a series of round-robin tests. These open and blind round-robin tests will comprise a new set of typical pressure boundary components including dissimilar metal welds (DMWs) and bottom-mounted instrumentation penetrations. Open round-robin tests will engage research and industry teams worldwide to investigate and demonstrate the reliability of emerging NDE techniques to detect and size flaws with a wide range of lengths, depths, orientations, and locations. Blind round-robin tests will utilize various testing organizations, whose inspectors and procedures are certified by the standards for the nuclear industry in their respective countries, to investigate the ability of established NDE techniques to detect and size flaws whose characteristics range from relatively easy to very difficult for detection and sizing. Blind and open round-robin testing started in late 2011 and early 2012, respectively. This paper will present the work scope with reports on progress, NDE methods evaluated, and project timeline for PARENT.

Bottom Mounted Instrumentation↗

Diagnostics for the optimization of an 11 keV inverse Compton scattering x-ray source

In a scope of a collaboration between Thales Communications and Security and CEA DAM DIF, 11 keV Xrays were produced by inverse Compton scattering on the ELSA facility. In this type of experiment, X-ray observation lies in the use of accurate electron and laser beam interaction diagnostics and on fitted X-ray detectors. The low interaction probability between < 100 {mu}m width, 12 ps [rms] length electron and photon pulses requires careful optimization of pulse spatial and temporal covering. Another issue was to observe 11 keV X-rays in the ambient radioactive noise of the linear accelerator. For that, we use a very sensitive detection scheme based on radio luminescent screens.

43 PARTICLE ACCELERATORS↗