Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Development of CCD Cameras for Soft X-ray Imaging at the National Ignition Facility

The Static X-Ray Imager (SXI) is a National Ignition Facility (NIF) diagnostic that uses a CCD camera to record time-integrated X-ray images of target features such as the laser entrance hole of hohlraums. SXI has two dedicated positioners on the NIF target chamber for viewing the target from above and below, and the X-ray energies of interest are 870 eV for the “soft” channel and 3 – 5 keV for the “hard” channels. The original cameras utilize a large format back-illuminated 2048 x 2048 CCD sensor with 24 micron pixels. Since the original sensor is no longer available, an effort was recently undertaken to build replacement cameras with suitable new sensors. Three of the new cameras use a commercially available front-illuminated CCD of similar size to the original, which has adequate sensitivity for the hard X-ray channels but not for the soft. For sensitivity below 1 keV, Lawrence Livermore National Laboratory (LLNL) had additional CCDs back-thinned and converted to back-illumination for use in the other two new cameras. In this paper we describe the characteristics of the new cameras and present performance data (quantum efficiency, flat field, and dynamic range) for the front- and back-illuminated cameras, with comparisons to the original cameras.

National Ignition Facility, X-ray diagnostic, X-ra↗

Method of rotation angle measurement in machine vision based on calibration pattern with spot array

We propose a method of rotation angle measurement with high precision in machine vision. An area scan CCD camera, imaging lens, and calibration pattern with a spot array make up the measurement device for measuring the rotation angle. The calibration pattern with a spot array is installed at the rotation part, and the CCD camera is set at a certain distance from the rotation components. The coordinates of the spots on the calibration pattern is acquired through the vision image of the calibration pattern captured by the CCD camera. At the initial position of the calibration pattern, the camera is calibrated with the spot array; the mathematical model of distortion error of the CCD camera is built. With the equation of coordinate rotation measurement, the rotation angle of the spot array is detected. In the theoretic simulation, noise of different levels is added to the coordinates of the spot array. The experiment results show that the measurement device can measure the rotation angle precisely with a noncontact method. The standard deviation of rotation angle measurement is smaller than 3 arc sec. The measurement device can measure both microangles and large angles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DENSITY EFFECT OF SOLIDIFIED HYDROGEN ISOTOPE PARTICLES ON PARTICLE IMAGE VELOCIMETRY MEASUREMENTS OF HE II FLOW

Solid H{sub 2}, D{sub 2} and H{sub 2}/D{sub 2} particles can be generated in He II by solidifying directly from the gas phase. Here we compare these three different particles as tracers for tracking He II forced flow in a horizontal channel using the Particle Image Velocimetry (PIV) technique. Slip velocity measurements show that all generated particles are in the micron size range. Steady state velocity fields of the forced flow of He II within a square cross-section channel are measured. By comparing the results obtained from different tracers, we show that the slip velocity caused by non-neutral buoyancy of these particles does not affect the measured velocity profiles of He II forced flow.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlating the WFC and the IBIS hard X-ray surveys

During the operational life of BeppoSax, the Wide Field Camera observations covered almost the full sky at different epochs. The energy coverage, wide field of view and imaging capabilities share many commonalities with IBIS, the gamma-ray telescope onboard INTEGRAL satellite. We mosaicked all the available single pointing WFC observation images and then we searched the map for persistent and transient sources as has been done for the IBIS survey. This work represents the first unbiased source list compilation produced in this way from the overall WFC data set.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo simulation of a novel water-equivalent electronic portal imaging device using plastic scintillating fibers

Purpose: Most electronic portal imaging devices (EPIDs) developed so far use a thin Cu plate/phosphor screen to convert x-ray energies into light photons, while maintaining a high spatial resolution. This results in a low x-ray absorption and thus a low quantum efficiency (QE) of approximately 2-4% for megavoltage (MV) x-rays. A significant increase of QE is desirable for applications such as MV cone-beam computed tomography (MV-CBCT). Furthermore, the Cu plate/phosphor screen contains high atomic number (high-Z) materials, resulting in an undesirable over-response to low energy x-rays (due to photoelectric effect) as well as high energy x-rays (due to pair production) when used for dosimetric verification. Our goal is to develop a new MV x-ray detector that has a high QE and uses low-Z materials to overcome the obstacles faced by current MV x-ray imaging technologies. Methods: A new high QE and low-Z EPID is proposed. It consists of a matrix of plastic scintillating fibers embedded in a water-equivalent medium and coupled to an optically sensitive 2D active matrix flat panel imager (AMFPI) for image readout. It differs from the previous approach that uses segmented crystalline scintillators made of higher density and higher atomic number materials to detect MV x-rays. The plastic scintillating fibers are focused toward the x-ray source to avoid image blurring due to oblique incidence of off-axis x-rays. When MV x-rays interact with the scintillating fibers in the detector, scintillation light will be produced. The light photons produced in a fiber core and emitted within the acceptance angle of the fiber will be guided toward the AMFPI by total internal reflection. A Monte Carlo simulation has been used to investigate imaging and dosimetric characteristics of the proposed detector under irradiation of MV x-rays. Results: Properties, such as detection efficiency, modulation transfer function, detective quantum efficiency (DQE), energy dependence of detector response, and water-equivalence of dose response have been investigated. It has been found that the zero frequency DQE of the proposed detector can be up to 37% at 6 MV. The detector, also, is water-equivalent with a relatively uniform response to different energy x-rays as compared to current EPIDs. Conclusions: The results of our simulations show that, using plastic scintillating fibers, it is possible to construct a water-equivalent EPID that has a better energy response and a higher detection efficiency than current flat panel based EPIDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub‐Diffraction Correlation of Quantum Emitters and Local Strain Fields in Strain‐Engineered WSe 2 Monolayers

Strain-engineering in atomically thin metal dichalcogenides is a useful method for realizing single-photon emitters (SPEs) for quantum technologies. Correlating SPE position with local strain topography is challenging due to localization inaccuracies from the diffraction limit. Currently, SPEs are assumed to be positioned at the highest strained location and are typically identified by randomly screening narrow-linewidth emitters, of which only a few are spectrally pure. In this work, hyperspectral quantum emitter localization microscopy is used to locate 33 SPEs in nanoparticle-strained WSe 2 monolayers with sub-diffraction-limit resolution (≈30 nm) and correlate their positions with the underlying strain field via image registration. In this system, spectrally pure emitters are not concentrated at the highest strain location due to spectral contamination; instead, isolable SPEs are distributed away from points of peak strain with an average displacement of 240 nm. These observations point toward a need for a change in the design rules for strain-engineered SPEs and constitute a key step toward realizing next-generation quantum optical architectures.

2D material↗

Speckle suppression using a liquid-crystal cell

A simple method for suppressing speckles in images produced by laser projectors is proposed. The coherence of the laser beam and, therefore, speckles can be destroyed when the beam passes through an electrooptical cell in which a special ferroelectric liquid crystal is used as a modulating medium. The effect is achieved due to the spatially inhomogeneous phase modulation of light when specially shaped bipolar electric pulses are applied to the cell. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single shot cathode transverse momentum imaging in high brightness photoinjectors

In state of the art photoinjector electron sources, thermal emittance from photoemission dominates the final injector emittance. Therefore, low thermal emittance cathode developments and diagnostics are very important. Conventional thermal emittance measurements for the high gradient gun are time-consuming and thus thermal emittance is not measured as frequently as quantum efficiency during the lifetime of photocathodes, although both are important properties for the photoinjector optimizations. In this paper, a single shot measurement of photoemission transverse momentum, i.e., thermal emittance per rms laser spot size, is proposed for photocathode rf guns. By tuning the gun solenoid focusing, the electrons’ transverse momenta at the cathode are imaged to a downstream screen, which enables a single shot measurement of both the rms value and the detailed spectra of the photoelectrons’ transverse momenta. Both simulations and proof of principle experiments are reported.

43 PARTICLE ACCELERATORS↗

Performance studies of atomic layer deposited microchannel plate electron multipliers

Microchannel plate (MCP) photon counting, event timing, imaging detectors have found wide use in astronomical, remote sensing, and biological imaging applications. Novel MCP technology using borosilicate glass microcapillary array substrates functionalized by the application of resistive and secondary emissive layers using atomic layer deposition (ALD) techniques has the potential to outperform traditional MCP technology. Using ALD techniques to functionalize the MCPs allow customization of parameters like gain and resistance independently from the glass substrate. Borosilicate substrates have many advantages over traditional micro-capillary arrays, including low radioactive content, higher open area ratios, low outgassing, and high operational stability. These ALD MCPs can be manufactured in large areas (400 cm 2 ) providing a unique solution for many timing/imaging applications. ALD MCPs can withstand the processing temperatures required for high temperature deposition of III-V materials, such as Gallium Nitride, for UV photocathodes with high quantum efficiencies (QE) in the Near-UV (similar to 100-380 nm). We present the effects of different ALD configurations on the gain (magnitude and uniformity), resistance, imaging, background and detection efficiency, and how these parameters change during lifetime testing. Here, we also present the QE of ALD MCPs and various QE enhancement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Circular orientation fluorescence emitter imaging (COFEI) of rotational motion of motor proteins

Single-molecule fluorescence polarization technique has been utilized to detect structural changes in biomolecules and intermolecular interactions. Here we developed a single-molecule fluorescence polarization measurement system, named circular orientation fluorescence emitter imaging (COFEI), in which a ring pattern of an acquired fluorescent image (COFEI image) represents an orientation of a polarization and a polarization factor. Rotation and pattern change of the COFEI image allow us to find changes in the polarization by eye and further values of the parameters of a polarization are determined by simple image analysis with high accuracy. We validated its potential applications of COFEI by three assays: 1) Detection of stepwise rotation of F{sub 1}-ATPase via single quantum nanorod attached to the rotary shaft γ; 2) Visualization of binding of fluorescent ATP analog to the catalytic subunit in F{sub 1}-ATPase; and 3) Association and dissociation of one head of dimeric kinesin-1 on the microtubule during its processive movement through single bifunctional fluorescent probes attached to the head. These results indicate that the COFEI provides us the advantages of the user-friendly measurement system and persuasive data presentations.

60 APPLIED LIFE SCIENCES↗

Volumetric quantification of lung nodules in CT with iterative reconstruction (ASiR and MBIR)

Purpose: Volume quantifications of lung nodules with multidetector computed tomography (CT) images provide useful information for monitoring nodule developments. The accuracy and precision of the volume quantification, however, can be impacted by imaging and reconstruction parameters. This study aimed to investigate the impact of iterative reconstruction algorithms on the accuracy and precision of volume quantification with dose and slice thickness as additional variables.Methods: Repeated CT images were acquired from an anthropomorphic chest phantom with synthetic nodules (9.5 and 4.8 mm) at six dose levels, and reconstructed with three reconstruction algorithms [filtered backprojection (FBP), adaptive statistical iterative reconstruction (ASiR), and model based iterative reconstruction (MBIR)] into three slice thicknesses. The nodule volumes were measured with two clinical software (A: Lung VCAR, B: iNtuition), and analyzed for accuracy and precision.Results: Precision was found to be generally comparable between FBP and iterative reconstruction with no statistically significant difference noted for different dose levels, slice thickness, and segmentation software. Accuracy was found to be more variable. For large nodules, the accuracy was significantly different between ASiR and FBP for all slice thicknesses with both software, and significantly different between MBIR and FBP for 0.625 mm slice thickness with Software A and for all slice thicknesses with Software B. For small nodules, the accuracy was more similar between FBP and iterative reconstruction, with the exception of ASIR vs FBP at 1.25 mm with Software A and MBIR vs FBP at 0.625 mm with Software A.Conclusions: The systematic difference between the accuracy of FBP and iterative reconstructions highlights the importance of extending current segmentation software to accommodate the image characteristics of iterative reconstructions. In addition, a calibration process may help reduce the dependency of accuracy on reconstruction algorithms, such that volumes quantified from scans of different reconstruction algorithms can be compared. The little difference found between the precision of FBP and iterative reconstructions could be a result of both iterative reconstruction's diminished noise reduction at the edge of the nodules as well as the loss of resolution at high noise levels with iterative reconstruction. The findings do not rule out potential advantage of IR that might be evident in a study that uses a larger number of nodules or repeated scans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method

Purpose: To generalize and experimentally validate a novel algorithm for reconstructing the 3D pose (position and orientation) of implanted brachytherapy seeds from a set of a few measured 2D cone-beam CT (CBCT) x-ray projections. Methods: The iterative forward projection matching (IFPM) algorithm was generalized to reconstruct the 3D pose, as well as the centroid, of brachytherapy seeds from three to ten measured 2D projections. The gIFPM algorithm finds the set of seed poses that minimizes the sum-of-squared-difference of the pixel-by-pixel intensities between computed and measured autosegmented radiographic projections of the implant. Numerical simulations of clinically realistic brachytherapy seed configurations were performed to demonstrate the proof of principle. An in-house machined brachytherapy phantom, which supports precise specification of seed position and orientation at known values for simulated implant geometries, was used to experimentally validate this algorithm. The phantom was scanned on an ACUITY CBCT digital simulator over a full 660 sinogram projections. Three to ten x-ray images were selected from the full set of CBCT sinogram projections and postprocessed to create binary seed-only images. Results: In the numerical simulations, seed reconstruction position and orientation errors were approximately 0.6 mm and 5 deg., respectively. The physical phantom measurements demonstrated an absolute positional accuracy of (0.78{+-}0.57) mm or less. The {theta} and {phi} angle errors were found to be (5.7{+-}4.9) deg. and (6.0{+-}4.1) deg., respectively, or less when using three projections; with six projections, results were slightly better. The mean registration error was better than 1 mm/6 deg. compared to the measured seed projections. Each test trial converged in 10-20 iterations with computation time of 12-18 min/iteration on a 1 GHz processor. Conclusions: This work describes a novel, accurate, and completely automatic method for reconstructing seed orientations, as well as centroids, from a small number of radiographic projections, in support of intraoperative planning and adaptive replanning. Unlike standard back-projection methods, gIFPM avoids the need to match corresponding seed images on the projections. This algorithm also successfully reconstructs overlapping clustered and highly migrated seeds in the implant. The accuracy of better than 1 mm and 6 deg. demonstrates that gIFPM has the potential to support 2D Task Group 43 calculations in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Gradient Projection Approach for Fourier-Based Image Restoration

This work deals with the ill-posed inverse problem of reconstructing a two-dimensional image of an unknown object starting from sparse and nonuniform measurements of its Fourier Transform. In particular, if we consider a priori information about the target image (e.g., the nonnegativity of the pixels), this inverse problem can be reformulated as a constrained optimization problem, in which the stationary points of the objective function can be viewed as the solutions of a deconvolution problem with a suitable kernel. We propose a fast and effective gradient-projection iterative algorithm to provide regularized solutions of such a deconvolution problem by early stopping the iterations. Preliminary results on a real-world application in astronomy are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pressure–Modulated Luminescence Enhancement and Quenching in a Hydrogen–Bonded Organic Framework

Light emission in the solid state is central for illumination, sensing, and imaging applications. Unlike luminescence in dilute solutions, where the excited states are unimolecular in nature, intermolecular interaction plays a significant role in the quantum yield of solid-state luminophores, manifested as competing aggregation-caused quenching (ACQ) and aggregation-induced enhancement (AIE). Both effects are extensively studied in various systems; however, it remains unclear how their competition depends on molecular conformation and intermolecular stacking. Here the direct observation of pressure-modulated AIE-ACQ competition in a crystalline hydrogen-bonded organic framework (HOF) is reported. Using in situ spectroscopies and computational modeling, the intramolecular vibration and intermolecular π–π stacking directly responsible for the non-radiative decay of the excited state are identified. The extent of these two contributions is modulated by hydrostatic pressure and guest molecules in the HOF pores. Furthermore, this work demonstrates a physically neat model system to understand and control solid-state luminescence, and a potential material platform for piezoluminescent sensing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Annealing Temperature on Structure and Magnetic Properties of Zn{sub 0.94}Mg{sub 0.01}Mn{sub 0.05}O Nanoparticles

Structural and magnetic characteristics of Zn{sub 0.94}Mg{sub 0.01}Mn{sub 0.05}O (ZnMgMnO) nanoparticles synthesized by Sol-Gel preparation technique in a wide temperature range were reported. The influence of annealing temperature on the crystal structure of ZnMgMnO nanoparticles was figured out by X-ray diffraction technique (XRD). To optimize the annealing temperature and reveal the particle formation and size, Scanning Electron Microscope (SEM) imaging technique was performed. The required stoichiometry of the synthesized samples was obtained by an energy dispersive X-ray analysis technique (EDX). Quantum Design Vibrating Sample Magnetometer (QDVSM) tool was used for the magnetic characterizations of Zn{sub 0.94}Mg{sub 0.01}Mn{sub 0.05}O composition. Magnetization measurements as a function of magnetic field (M-H) were performed in the magnetic field up to 10 kOe. Temperature dependence of magnetization measurements (M-T) was taken between 10 and 320 K temperature ranges.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Energy Funneling in a Noninteger Two-Dimensional Perovskite

Energy funneling is a phenomenon that has been exploited in optoelectronic devices based on low-dimensional materials to improve their performance. Here, we introduce a new class of two-dimensional semiconductor, characterized by multiple regions of varying thickness in a single confined nanostructure with homogeneous composition. This "noninteger 2D semiconductor" was prepared via the structural transformation of two-octahedron-layer-thick (n = 2) 2D cesium lead bromide perovskite nanosheets; it consisted of a central n = 2 region surrounded by edge-lying n = 3 regions, as imaged by electron microscopy. Thicker noninteger 2D CsPbBr 3 nanostructures were obtained as well. Finally, these noninteger 2D perovskites formed a laterally coupled quantum well band alignment with virtually no strain at the interface and no dielectric barrier, across which unprecedented intramaterial funneling of the photoexcitation energy was observed from the thin to the thick regions using time-resolved absorption and photoluminescence spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Refine your search to explore more results.