Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Efficient Quantum Gate Discovery with Optimal Control

Optimal control theory provides a framework for numerical discovery of device controls that implement quantum logic gates, but common objective functions used for optimization often assign arbitrarily high costs to otherwise useful controls. We propose a framework for designing objective functions that permit novel gate designs such as echo pulses or locally-equivalent gates. We use numerical simulations to demonstrate the efficacy of the new objective functions by designing microwave-only pulses that act as entangling gates for superconducting transmon architectures. We observe that the proposed objective functions lead to higher fidelity controls in fewer optimization iterations than obtainable by traditional objective functions.

Kairys, Paul↗

International Space Station Bipropellant Plume Contamination Model Update for Short Thruster Pulse Widths

The International Space Station (ISS) Bipropellant Plume Contamination Model has been a vital tool for characterizing the thruster plume-induced contamination environment at the ISS but was not intended to be used for very short thruster pulse widths. This paper presents an updated model that ensures full start-up and shut-down phases are modeled for each thruster firing, when the majority of liquid phase contaminant mass is released. The updated ISS Bipropellant Plume Contamination Model prevents potential under-prediction of thruster plume-induced contamination due to visiting vehicle proximity operations and provides a way to take advantage of thruster start-up and shut-down data performance data gathered during thruster test programs, if available. The International Space Station (ISS) Bipropellant Plume Contamination Model developed by Boeing Space Environments is a semi-empirical model anchored in flight experiment data and has been a vital tool for characterizing the thruster plume-induced contamination environment at the ISS.[1] The current model utilizes flight experiment data from the Plume Impingement Contamination (PIC) and Shuttle Plume Impingement Flight Experiment (SPIFEX) studies, which include Orbiter 3870 N Primary Reaction Control System (PRCS) and Russian 130 N thrusters operating in pulse mode with 80-100 ms.[2] As the next generation of crew and cargo visiting vehicles are developed and arrive at ISS, minimum pulse widths of vehicle thrusters used for ISS proximity operations have decreased significantly below 80 ms. An update to the ISS Bipropellant Contamination Model is needed to prevent potential under-prediction of thruster plume-induced contamination for these very short pulse widths. Contamination due to thruster plumes occurs in the liquid phase (i.e., unburned or partially burned propellant in the plume). Liquid phase releases primarily occur during thruster start-up and shut-down phases, with the steady state phase contributing a small amount to the total contaminant mass released. The current ISS Bipropellant Plume Contamination Model includes functional dependencies on thruster parameters (thrust, mass flow rate, specific impulse (Isp)), distance to receiver surface, and angle off plume centerline. For modeling purposes, contaminant mass released scales linearly with pulse width. This is a conservative approach for pulse widths greater than 80 ms but could under-predict contamination for very short pulse widths (i.e., with little or no steady state phase). This paper presents a model update to add a functional dependency on commanded pulse width to ensure the portion of the pulse spent in start-up and shut-down phases is appropriately modeled, when the majority of liquid phase contaminant mass is released. The updated model prevents potential under-prediction of thruster plume-induced contamination due to visiting vehicle proximity operations while providing a way to take advantage of thruster start-up and shut-down data gathered during test programs, if available. Developing the plume model for a specific thruster using the ISS Bipropellant Plume Contamination Model must be done in consideration of all available thruster performance data. Example thruster data will be used to illustrate this point and options for implementing the model update with existing ISS Bipropellant Plume Contamination Model code will be discussed.

plume contamination↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Stereoselective isomerization of an ensemble of adsorbed molecules with multiple orientations: Stochastic laser pulse optimization for selective switching between achiral and chiral atropisomers

We present quantum dynamical simulations for the laser driven isomerization of an ensemble of surface mounted stereoisomers with multiple orientations. The model system 1-(2-cis-fluoroethenyl)-2-fluorobenzene supports two chiral and one achiral atropisomers upon torsion around the C-C single bond connecting phenyl ring and ethylene group. An infrared picosecond pulse is used to excite the internal rotation around the chiral axis, thereby controlling the chirality of the molecule. In order to selectively switch the molecules--independent of their orientation on a surface--from their achiral to either their left- or right-handed form, a stochastic pulse optimization algorithm is applied. The stochastic pulse optimization is performed for different sets of defined orientations of adsorbates corresponding to the rotational symmetry of the surface. The obtained nonlinearly polarized laser pulses are highly enantioselective for each orientation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Functionality and operation of fluoroscopic automatic brightness control/automatic dose rate control logic in modern cardiovascular and interventional angiography systems: A Report of Task Group 125 Radiography/Fluoroscopy Subcommittee, Imaging Physics Committee, Science Council

Task Group 125 (TG 125) was charged with investigating the functionality of fluoroscopic automatic dose rate and image quality control logic in modern angiographic systems, paying specific attention to the spectral shaping filters and variations in the selected radiologic imaging parameters. The task group was also charged with describing the operational aspects of the imaging equipment for the purpose of assisting the clinical medical physicist with clinical set-up and performance evaluation. Although there are clear distinctions between the fluoroscopic operation of an angiographic system and its acquisition modes (digital cine, digital angiography, digital subtraction angiography, etc.), the scope of this work was limited to the fluoroscopic operation of the systems studied. The use of spectral shaping filters in cardiovascular and interventional angiography equipment has been shown to reduce patient dose. If the imaging control algorithm were programmed to work in conjunction with the selected spectral filter, and if the generator parameters were optimized for the selected filter, then image quality could also be improved. Although assessment of image quality was not included as part of this report, it was recognized that for fluoroscopic imaging the parameters that influence radiation output, differential absorption, and patient dose are also the same parameters that influence image quality. Therefore, this report will utilize the terminology ''automatic dose rate and image quality'' (ADRIQ) when describing the control logic in modern interventional angiographic systems and, where relevant, will describe the influence of controlled parameters on the subsequent image quality. A total of 22 angiography units were investigated by the task group and of these one each was chosen as representative of the equipment manufactured by GE Healthcare, Philips Medical Systems, Shimadzu Medical USA, and Siemens Medical Systems. All equipment, for which measurement data were included in this report, was manufactured within the three year period from 2006 to 2008. Using polymethylmethacrylate (PMMA) plastic to simulate patient attenuation, each angiographic imaging system was evaluated by recording the following parameters: tube potential in units of kilovolts peak (kVp), tube current in units of milliamperes (mA), pulse width (PW) in units of milliseconds (ms), spectral filtration setting, and patient air kerma rate (PAKR) as a function of the attenuator thickness. Data were graphically plotted to reveal the manner in which the ADRIQ control logic responded to changes in object attenuation. There were similarities in the manner in which the ADRIQ control logic operated that allowed the four chosen devices to be divided into two groups, with two of the systems in each group. There were also unique approaches to the ADRIQ control logic that were associated with some of the systems, and these are described in the report. The evaluation revealed relevant information about the testing procedure and also about the manner in which different manufacturers approach the utilization of spectral filtration, pulsed fluoroscopy, and maximum PAKR limitation. This information should be particularly valuable to the clinical medical physicist charged with acceptance testing and performance evaluation of modern angiographic systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Generation of fast photoelectrons in strong-field emission from metal nanoparticles

We investigated the generation and control of fast photoelectrons (PEs) by exposing plasmonic nanoparticles (NPs) to short infrared (IR) laser pulses with peak intensities between 10 12 and 3 × 10 13 W/cm 2 . Our measured and numerically simulated PE momentum distributions demonstrate the extent to which PE yields and cutoff energies are controlled by the NP size, material, and laser peak intensity. For strong-field photoemission from spherical silver, gold, and platinum NPs with diameters between 10 and 100 nm our results confirm and surpass extremely high PEs cutoff energies, up to several hundred times the incident laser-pulse ponderomotive energy, found recently for gold nanospheres [Saydanzad et al., Nanophotonics 12, 1931 (2023)]. As reported previously for dielectric NPs [Rupp et al., J. Mod. Opt. 64, 995 (2017)], at higher intensities the cutoff energies we deduce from measured and simulated PE spectra tend to converge to a metal-independent limit. We expect these characteristics of light-induced electron emission from prototypical plasmonic metallic nanospheres to promote the understanding of the electronic dynamics in more complex plasmonic nanostructures and the design of nanoscale light-controlled plasmonic electron sources for photoelectronic devices of applied interest.

electron source↗

All-electrical time-resolved spin generation and spin manipulation in n-InGaAs

We demonstrate all-electrical spin generation and subsequent manipulation by two successive electric field pulses in an n-InGaAs heterostructure in a time-resolved experiment at zero external magnetic field. The first electric field pulse along the [11{sup ¯}0] crystal axis creates a current-induced spin polarization (CISP) which is oriented in the plane of the sample. The subsequent electric field pulse along [110] generates a perpendicular magnetic field pulse leading to a coherent precession of this spin polarization with 2-dimensional electrical control over the final spin orientation. Spin precession is probed by time-resolved Faraday rotation. We determine the build-up time of CISP during the first field pulse and extract the spin dephasing time and internal magnetic field strength during the spin manipulation pulse.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rapid Laser Induced Crystallization of Amorphous NiTi Films Observed by Nanosecond Dynamic Transmission Electron Microscopy (DTEM)

The crystallization processes of the as-deposited, amorphous NiTi thin films have been studied in detail using techniques such as differential scanning calorimetry and, in-situ TEM. The kinetic data have been analyzed in terms of Johnson-Mehl-Avrami-Kolomogrov (JMAK) semi-empirical formula. The kinetic parameters determined from this analysis have been useful in defining process control parameters for tailoring microstructural features and shape memory properties. Due to the commercial push to shrink thin film-based devices, unique processing techniques have been developed using laser-based annealing to spatially control the microstructure evolution down to sub-micron levels. Nanosecond, pulse laser annealing is particularly attractive since it limits the amount of peripheral heating and unwanted microstructural changes to underlying or surrounding material. However, crystallization under pulsed laser irradiation can differ significantly from conventional thermal annealing, e.g., slow heating in a furnace. This is especially true for amorphous NiTi materials and relevant for shape memory thin film based microelectromechanical systems (MEMS) applications. There is little to no data on the crystallization kinetics of NiTi under pulsed laser irradiation, primarily due to the high crystallization rates intrinsic to high temperature annealing and the spatial and temporal resolution limits of standard techniques. However, with the high time and spatial resolution capabilities of the dynamic transmission electron microscope (DTEM) constructed at Lawrence Livermore National Laboratory, the rapid nucleation events occurring from pulsed laser irradiation can be directly observed and nucleation rates can be quantified. This paper briefly explains the DTEM approach and how it used to investigate the pulsed laser induced crystallization processes in NiTi and to determine kinetic parameters.

36 MATERIALS SCIENCE↗

Cusps enable line attractors for neural computation

Here, line attractors in neuronal networks have been suggested to be the basis of many brain functions, such as working memory, oculomotor control, head movement, locomotion, and sensory processing. In this paper, we make the connection between line attractors and pulse gating in feed-forward neuronal networks. In this context, because of their neutral stability along a one-dimensional manifold, line attractors are associated with a time-translational invariance that allows graded information to be propagated from one neuronal population to the next. To understand how pulse-gating manifests itself in a high-dimensional, nonlinear, feedforward integrate-and-fire network, we use a Fokker-Planck approach to analyze system dynamics. We make a connection between pulse-gated propagation in the Fokker-Planck and population-averaged mean-field (firing rate) models, and then identify an approximate line attractor in state space as the essential structure underlying graded information propagation. An analysis of the line attractor shows that it consists of three fixed points: a central saddle with an unstable manifold along the line and stable manifolds orthogonal to the line, which is surrounded on either side by stable fixed points. Along the manifold defined by the fixed points, slow dynamics give rise to a ghost. We show that this line attractor arises at a cusp catastrophe, where a fold bifurcation develops as a function of synaptic noise; and that the ghost dynamics near the fold of the cusp underly the robustness of the line attractor. Understanding the dynamical aspects of this cusp catastrophe allows us to show how line attractors can persist in biologically realistic neuronal networks and how the interplay of pulse gating, synaptic coupling, and neuronal stochasticity can be used to enable attracting one-dimensional manifolds and, thus, dynamically control the processing of graded information.

59 BASIC BIOLOGICAL SCIENCES↗

Filamentation of long-wave infrared pulses in the atmosphere

Filamentation of a high-power laser beam in air opens possibility of the diffraction-compensated propagation of a laser beam over long distances and as such is being considered for remote stand-off detection, lightning control, free-space communications, and long-range projection of high-energy pulses. Switching to long-wave infrared (LWIR) range for filamentation, as shown in recent experiments, allows for generation of a single centimeter-diameter channel in air that, in comparison with a short-wavelength laser filament, has four orders of magnitude larger cross-section and guides many Joules of pulse energy over multiple Rayleigh distances at a clamped intensity of ~10 12 W/cm 2 . Self-guiding of LWIR pulses in air arises from the balance between self-focusing, diffraction and defocusing caused by free carriers generated via many-body Coulomb induced ionization which effectively decrease the molecular polarizability during the long-wavelength laser pulse. Understanding where this new ionization regime plays a role, below the threshold of the well adopted single-atom tunnel ionization in gases, could became a new frontier in strong-field interactions. Here, this paper offers an overview of the atmospheric filamentation research at long-wave infrared wavelengths.

43 PARTICLE ACCELERATORS↗

Development and Testing of Pulse Guns for Combustion Instability Testing

To test liquid rocket engines (LREs) for combustion instabilities, devices such as bombs are often used to create pressure wave disturbances. Bombs, while effective, are inherently dangerous, expensive, and difficult to procure. Over the years, pulse guns have been used as a safer and more cost-effective way to generate controlled pressure disturbances in engine chambers. In anticipation of the need for stability testing of prototype LREs at NASA Marshall Space Flight Center (MSFC), a set of pulse guns have been designed, fabricated, tested, and characterized. The pulse gun program is funded by the RS-25 Engine Program managed out of MSFC and funded by NASA’s Space Launch System (SLS) through the MSFC Liquid Engines Office (LEO). A pulse gun is a simple device – like a traditional gun, it has a breech and barrel section. However, unlike a traditional gun, there is no bullet, as the purpose of the pulse gun is strictly to fire a high pressure pulse. Instead of a firing pin and primer that would normally be used in a traditional gun, an initiator is used to activate the gun powder. The initiator is a highly reliable pyrotechnic initiator. For this study, clone versions of the NASA Standard Initiator (NSI) were used. The initiator is used to ignite a pre-measured amount of gun powder loaded into the breech. When the pressure of the burnt gun powder exceeds the set point of a downstream burst disk, the disk ruptures, allowing the high pressure pulse to travel downstream through the barrel section. A ballistic pressure transducer located in the breech section is used to measure the short duration, high pressure pulse. Some configurations of the pulse gun have barrel sections that include one or more additional ballistic pressure transducers. These additional pressure measurements help track the degradation and damping of the pulse as it travels out of the barrel section. The measurements may also be used to determine the velocity of pulse. The objective of this paper is to present the different variants of this newly-developed pulse gun and characterize performance over a range of parameters. The parameters include breech diameter, barrel length, amount of gun powder used, the way the gun powder is packed, and the pressure setting of the burst disk. There are a total of six pulse guns: three with the 0.25 inch breech and three different length barrels, and three with the 0.40 inch breech and three different length barrels. For both breech sizes, the associated barrels are referred to as standard, one-port, and two-port barrels. The standard barrel has no instrumentation and is likely the barrel that will be used for engine stability testing. The one- and two-port barrels were designed specifically for pulse gun component testing to allow measurements of the magnitude and timing of the high pressure pulse as it makes its way through the pulse gun. The burst disks tested were commercially-available burst disks designed to rupture at 8,000, 16,000, and 24,000 psid. Testing was accomplished by firing the pulse gun into a test chamber pressurized with nitrogen at about 2300 psig. A total of four Model 113B23 High frequency ICP® pressure sensors (10k psi) were mounted in the test chamber, in the same plane as the pulse gun. Two of the sensors had “trimmed” adapters, and two did not. Given the symmetrical configuration of the sensors within the test chamber, different amplitudes of pressure measurements are attributed to the use of trimmed versus untrimmed adapters. The untrimmed adapters, with their narrower passages, tended to amplify the pressure amplitudes by as much as 50%. In total, 41 pulse gun tests have been conducted.Data are still being analyzed, but some trends are apparent. For example, measurements taken within the pulse gun are shown in Figures 3 and 4 for Hot-fires (HFs) # 11 and 39, respectively. Both tests were identical in that the 0.40 inch ID breech, two-port barrel, 8,000 psid burst disk, and same amount of gunpowder (6.639 grains for HF# 11, and 6.576 grains for HF# 39) were used, and the back pressure in the nitrogen test chamber was ~2300 psig. Despite keeping all these variables constant, the results from these two tests look quite different. For both tests, the first pressure peak shown in the P2111 trace within the breech is the firing of the initiator. The second peak and any subsequent peaks are from the combustion of the gunpowder. It should be noted that because the sensors are dynamic, the ~2300 psig baseline static pressure is not shown in the figures. For HF# 11, the burst disk clearly ruptured in a little over 0.1 ms from the time the initiator was fired. This is evident from the abrupt rise in pressure for P2112 followed by another abrupt rise in pressure for P2113. The sensors track the movement of the high pressure pulse through the pulse gun. For HF# 39, however, there was nearly 1 ms delay between the initiator firing and the burst disk rupturing. The only difference between these two tests was the way in which the gunpowder was packed within the breech. For HF# 11, the gunpowder was poured directly into the breech, atop the initiator, and held in place with a vegetable fiber wad appropriately sized for the barrel diameter. Once in place, the wad firmly held the gunpowder in place. For HF# 39, the gunpowder was rolled within cigarette paper with the ends of the paper twisted. The rolled gunpowder was gently pushed down into the breech, toward the initiator, and no wad was used. This method of loading the gunpowder consistently produced longer delays in the rupture of the burst disk, presumably because there was a steady, fuller burning of the gunpowder. The burst disk was rated for 8,000 psid, which means that the burst disk should not have opened until the pressure in the breech reached ~10,300 since there was ~2300 psig back pressure in the test chamber. In the case of HF# 11, the breech pressure only reached roughly 4200 psi before there was leakage either through or past the burst disk, but for HF#39, the breech pressure reached 10,600 psi prior to the burst disk opening. The temperature of the burst disk is certainly a factor in determining when the burst disk will rupture. A sharp rise in the burst disk temperature could weaken it and cause it to stray from the designed set point burst pressure. The burst disks are manufactured of Inconel to try to reduce their sensitivity to temperature, but how the burst disks perform above 900°F is not documented. All burst disks were engineered and tested by the manufacturer for ambient temperature conditions. One theory for why rolling the gunpowder in cigarette paper may produce better results is related to a more controlled temperature environment. The cigarette paper may act as a sheath that protects the burst disk from excessive temperatures during the rapid buildup of pressure in the breech. The ultimate benefit of not breeching the burst disk prematurely is shown in Figures 5 and 6, which graphs the resultant pressure pulse produced in the test chamber. For HF #11, the peak pressure on the P2123 trimmed adapter is about 270 psi, while for HF# 39 it is 343 psi, which is about 1.27 times greater in magnitude. In either case, the pressure pulse is ~20 μs in width once it reaches the test chamber. Another pressure rise about 100 μs later can be seen on the sensors located across from the pulse gun port, P2124 and P2121. These pressures are lower due to attenuation of the pressure wave as it moves across the test chamber. After the wave encounters the wall, it reflects back and forth within the chamber until it completely dissipates.

Pulse Gun↗

An ultra-wideband antenna for pulsed applications

A wideband feed is proposed to support wideband radiation, and a design process is presented for a slotline bowtie hybrid (SBH) antenna based on specified pattern characteristics. Measured results are presented to demonstrate the pattern control of the antenna over its bandwidth. Impulse response plots are used to illustrate the pulse performance of this antenna type. For the antenna discussed here, the bandwidth was measured to be 6 to 1 and actually is expected to be larger.

Darden, William H.↗

Flash radiotherapy accelerator

Methods, devices and systems for ultra-high dose radiotherapy are disclosed. The described techniques rely in-part on active switching control of a photoconductive switch during the time the accelerator is accelerating charged particles to produce the output radiation at the desired dose rates. One flash radiotherapy system includes an induction accelerator, and a controllable switch coupled to the induction accelerator. The switch is operable to produce a plurality of voltage pulses to drive the induction accelerator. The radiotherapy system also includes a radiation measurement device to measure output radiation produced by the radiotherapy system and provide feedback to the controllable switch. The controllable switch is operable to, based on the received feedback, modify an amplitude, shape, spacing, number or width of the voltage pulses that are supplied to the particle accelerator to deliver the desired output radiation.

Sampayan, Stephen E.↗

2010 MULTIPHOTON PROCESSES GORDON RESEARCH CONFERENCE, JUNE 6-11, 2010, TILTON, NH

The Gordon Research Conference on Multiphoton Processes will be held for the 15th time in 2010. The meeting continues to evolve as it embraces both the rapid technological and intellectual growth in the field as well as the multi-disciplinary expertise of the participants. This time the sessions will focus on: (1) Ultrafast coherent control; (2) Free-electron laser experiments and theory; (3) Generation of harmonics and attosecond pulses; (4) Ultrafast imaging; (5) Applications of very high intensity laser fields; (6) Strong-field processes in molecules and solids; (7) Attosecond science; and (8) Controlling light. The scientific program will blur traditional disciplinary boundaries as the presenters and discussion leaders involve chemists, physicists, and optical engineers, representing both experiment and theory. The broad range of expertise and different perspectives of attendees should provide a stimulating and unique environment for solving problems and developing new ideas in this rapidly evolving field.

42 ENGINEERING↗

Extended plasma channels created by UV laser in air and their application to control electric discharges

Results are presented from a series of experimental and theoretical studies on creating weakly ionized extended plasma channels in atmospheric air by 248-nm UV laser radiation and their application to control long high-voltage discharges. The main mechanisms of air ionization by UV laser pulses with durations from 100 fs to 25 ns and intensities in the ranges of 3×10{sup 11}–1.5×10{sup 13} and 3×10{sup 6}–3×10{sup 11} W/cm{sup 2}, respectively, which are below the threshold for optical gas breakdown, as well as the main relaxation processes in plasma with a density of 10{sup 9}–10{sup 17} cm{sup −3}, are considered. It is shown that plasma channels in air can be efficiently created by amplitude-modulated UV pulses consisting of a train of subpicosecond pulses producing primary photoelectrons and a long UV pulse suppressing electron attachment and sustaining the density of free electrons in plasma. Different modes of the generation and amplification of trains of subterawatt subpicosecond pulses and amplitude-modulated UV pulses with an energy of several tens of joules were implemented on the GARPUN-MTW hybrid Ti:sapphire-KrF laser facility. The filamentation of such UV laser beams during their propagation in air over distances of up to 100 m and the parameters of the corresponding plasma channels were studied experimentally and theoretically. Laser initiation of high-voltage electric discharges and control of their trajectories by means of amplitude-modulated UV pulses, as well as the spatiotemporal structure of breakdowns in air gaps with length of up to 80 cm, were studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tuning piezoelectric properties through epitaxy of La 2 Ti 2 O 7 and related thin films

Current piezoelectric sensors and actuators are limited to operating temperatures less than ~200ºC due to the low Curie temperature of the piezoelectric material. The strengthening the piezoelectric coupling of high-temperature piezoelectric materials, such as La 2 Ti 2 O 7 (LTO), would allow sensors to operate across a broad temperature range. The crystalline orientation and piezoelectric coupling direction of LTO thin films can be controlled by epitaxial matching to SrTiO 3 (001), SrTiO 3 (110), and rutile TiO 2 (110) substrates via pulsed laser deposition. The structure and phase purity of the films are investigated by x-ray diffraction and scanning transmission electron microscopy. Piezoresponse force microscopy is used to measure the in-plane and out-of-plane piezoelectric coupling in the films. The strength of the out-of-plane piezoelectric coupling can be increased when the piezoelectric direction is rotated partially out-of-plane via epitaxy. The strongest out-of-plane coupling is observed for LTO/STO(001). Deposition on TiO 2 (110) results in epitaxial La 2/3 TiO 3 , an orthorhombic perovskite of interest as a microwave dielectric material and an ion conductor. La 2/3 TiO 3 can be difficult to stabilize in bulk form, and epitaxial stabilization on TiO 2 (110) is a promising route to realize La 2/3 TiO 3 for both fundamental studies and device applications. Overall, these results confirm that control of the crystalline orientation of epitaxial LTO-based materials can govern the resulting functional properties.

36 MATERIALS SCIENCE↗

Time resolved mechanism of the isotope selectivity in the ultrafast light induced dissociation in N 2

The time evolution of a vacuum ultraviolet excited N2 molecule is followed all the way from an ultrafast excitation to dissociation by a quantum mechanical simulation. The primary aim is to discern the role of the excitation by a pulse short compared to the vibrational period, to discern the different coupling mechanisms between different electronic states, nonadiabatic, spin orbit, and to analyze the origin of any isotopic effect. We compare the picture in the time and energy domains. The initial ultrafast excitation pumps the molecule to a coherent electronic wave packet to which several singlet bound electronic states contribute. The total nonstationary wave function is given as a coherent sum of nuclear wave packets on each electronic state times the stationary electronic wave function. When the wave packets on different electronic states overlap, they are coupled in a mass-dependent manner whether one uses an adiabatic or a diabatic electronic basis. A weak spin-orbit coupling acts as a bottleneck between the bound singlet part of phase space and the triplet manifold of states in which dissociation takes place. To describe the spin-orbit perturbation that is ongoing in time, an energy-resolved eigenstate representation appears to be more intuitive. In the eigenstate basis, the singlet-to-triplet population transfer is large only between those vibronic eigenstates that are quasiresonant in energy. The states in resonance are different for different excitation energy ranges. Finally, the resonances are mass dependent, which explains the control of the isotope effect through the profile of the pulse.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic Manipulation of Single Erbium on GaAs(110): From Adatom Motion to Creation and Control of Bistable Substitutions

We demonstrate atomic-scale control over the position and configuration of single erbium (Er) atoms at the GaAs(110) surface using scanning tunneling microscopy (STM). By applying voltage pulses from the STM tip, we drive Er adatoms to move sequentially among three distinct adsorption sites and controllably substitute into Ga lattice sites. The resulting substitutional Er atoms exhibit two isoelectronic configurations that differ by less than one angstrom in lateral position and can be reversibly switched by additional voltage pulses. Differential conductance spectroscopy shows differences in the unoccupied local electronic states for the two substitutional configurations, and an absence of mid-gap states. Preliminary density functional theory (DFT) calculations support these findings, identifying the most stable adsorption and substitutional sites, their relative binding energies, charge states, and local density of states (LDOS) characteristics. Together, the experimental and theoretical results establish a method for precise, reversible manipulation of rare-earth dopants at semiconductor surfaces, opening a pathway to engineer atomic-scale quantum and optoelectronic functionalities.

Poche, Steven [Ohio State University]↗

Refine your search to explore more results.