Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pixel detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

SU-D-BRF-03: Improvement of TomoTherapy Megavoltage Topogram Image Quality for Automatic Registration During Patient Localization

Purpose: To improve the quality of mega-voltage orthogonal scout images (MV topograms) for a fast and low-dose alternative technique for patient localization on the TomoTherapy HiART system. Methods: Digitally reconstructed radiographs (DRR) of anthropomorphic head and pelvis phantoms were synthesized from kVCT under TomoTherapy geometry (kV-DRR). Lateral (LAT) and anterior-posterior (AP) aligned topograms were acquired with couch speeds of 1cm/s, 2cm/s, and 3cm/s. The phantoms were rigidly translated in all spatial directions with known offsets in increments of 5mm, 10mm, and 15mm to simulate daily positioning errors. The contrast of the MV topograms was automatically adjusted based on the image intensity characteristics. A low-pass fast Fourier transform filter removed high-frequency noise and a Weiner filter reduced stochastic noise caused by scattered radiation to the detector array. An intensity-based image registration algorithm was used to register the MV topograms to a corresponding kV-DRR by minimizing the mean square error between corresponding pixel intensities. The registration accuracy was assessed by comparing the normalized cross correlation coefficients (NCC) between the registered topograms and the kV-DRR. The applied phantom offsets were determined by registering the MV topograms with the kV-DRR and recovering the spatial translation of the MV topograms. Results: The automatic registration technique provided millimeter accuracy and was robust for the deformed MV topograms for three tested couch speeds. The lowest average NCC for all AP and LAT MV topograms was 0.96 for the head phantom and 0.93 for the pelvis phantom. The offsets were recovered to within 1.6mm and 6.5mm for the processed and the original MV topograms respectively. Conclusion: Automatic registration of the processed MV topograms to a corresponding kV-DRR recovered simulated daily positioning errors that were accurate to the order of a millimeter. These results suggest the clinical use of MV topograms as a promising alternative to MVCT patient alignment.

60 APPLIED LIFE SCIENCES↗

Development of processing algorithms to enable high-rate microcalorimeter array operation

The millisecond-scale decay constants of microcalorimeter gamma-ray pulses present challenges for operation at high count rates needed to compete with semiconductor HPGe detectors. If using conventional optimal filtering methods, pulse records with pileup events are simply discarded, leading to a large fraction of data unused when count rates are large. For single pixel rates exceeding 1-2 Hz, improved pulse processing algorithms are needed to better deal with pileup and increase the filter throughput. A 256-pixel array operating at 10 Hz per pixel would provide a total counting rate of 2.5 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of 3-D Gamma-camera

BNL and Gamma Medical Technologies (GMT) will jointly develop a compact three-dimensional (3-D) gamma camera capable of localizing cancerous tumors within the prostate gland. The new gamma-ray camera will consist of pixilated cadmium-zinc-telluride (CZT) detector arrays, which will be flip-chip bonded to a suitable substrate. Application specific integrated circuits (ASIC) will also be developed to read out the electronic signals from the pixels. The detector/ASIC coupled to a multi-view collimator would be integrated into a small probe capable of imaging shaped radioactive phantoms to simulate the presence of cancerous tumors within the prostate gland.

99 GENERAL AND MISCELLANEOUS↗

A dual charge-coupled device /CCD/, astronomical spectrometer and direct imaging camera. I - Optical and detector systems

The MASCOT (MIT Astronomical Spectrometer/Camera for Optical Telescopes), an instrument capable of simultaneously performing both direct imaging and spectrometry of faint objects, is examined. An optical layout is given of the instrument which uses two CCD's mounted on the same temperature regulated detector block. Two sources of noise on the signal are discussed: (1) the CCD readout noise, which results in a constant uncertainty in the number of electrons collected from each pixel; and (2) the photon counting noise. The sensitivity of the device is limited by the sky brightness, the overall quantum efficiency, the resolution, and the readout noise of the CCD. Therefore, total system efficiency is calculated at about 15%.

Meyer, S. S.↗

A Near-Infrared Mapping Spectrometer for investigation of Jupiter and its satellites

The Near-Infrared-Mapping Spectrometer (NIMS) is one of the science instruments in the Galileo mission, which will explore Jupiter and its satellites in the mid-1990's. The NIMS experiment will map geological units on the surfaces of the Jovian satellites and characterize their mineral content; and, for the atmosphere of Jupiter, investigate cloud properties and the spatial and temporal variability of molecular abundances. The optics are gold-coated reflective and consist of a telescope and a grating spectrometer. The balance of the instrument includes a 17-detector (silicon and indium antimonide) focal plane array, a tuning fork chopper, microprocessor-controlled electronics, and a passive radiative cooler. A wobbling secondary mirror in the telescope provides 20 pixels in one dimension of spatial scanning in a pushbroom mode with 0.5 mr x 0.5 mr instantaneous field of view. The spectral range is 0.7-5.2 microns; resolution is 0.025 micron. NIMS is the first infrared experiment to combine both spatial and spectral mapping capability in one instrument.

Aptaker, Irving M.↗

Search for soft X-ray emission from SN 1987A with a CCD X-ray imaging spectrometer

The results of soft X-ray observations of SN 1987A over the energy band 0.65-2.0 keV are reported. The upper limits on the soft X-ray flux are inconsistent with an extrapolation of the spectrum measured by the Ginga Satellite to the energy band and require a turnover in the X-ray spectrum between 2 and 4 keV. If this turnover is due to absorption by intervening material, a neutral column density associated with the supernova of at least 2.8 x 10 to the 21st/sq cm is required. The background rate for the Texas Instruments 800 x 800 pixel CCD, measured between 150 and 285 km altitude, was 1.1 counts/sq cm s. The background spectrum has a broad peak at 350 electrons, corresponding to charge deposited in the detector by minimally ionizing particles.

Burrows, D. N.↗

The South Pole Imaging Fabry Perot Interferometer (SPIFI)

The design and construction of the South Pole imaging Fabry-Perot interferometer (SPIFI) is reported. The SPIFI is a direct detection imaging spectrometer for use in the far infrared and submillimeter bands accessible to the 1.7 m telescope at the South Pole, and in the submillimeter bands accessible to the 15 m James Clerk Maxwell Telescope (JCMT), HI. It employs a 5 x 5 silicon bolometer array and three cryogenic Fabry Perot interferometers in series in order to achieve velocity resolutions of between 300 km/s and 30 km/s over the entire field of view with a resolution of up to 1 km/s at the center pixel. The scientific justification for the instrument is discussed, considering the spectral lines available to SPIFI. The optical path, the cryogenic Fabry-Perot, the adiabatic demagnetization refrigerator and the detector array are described. The instrument's sensitivity is presented and compared with coherent systems.

Stacey, G. J.↗

Elemental X-ray Imaging Using the Maia Detector Array: The Benefits and Challenges of Large Solid-Angle

The fundamental parameter method for quantitative SXRF and PIXE analysis and imaging using the dynamic analysis method is extended to model the changing X-ray yields and detector sensitivity with angle across large detector arrays. The method is implemented in the GeoPIXE software and applied to cope with the large solid-angle of the new Maia 384 detector array and its 96 detector prototype developed by CSIRO and BNL for SXRF imaging applications at the Australian and NSLS synchrotrons. Peak-to-background is controlled by mitigating charge-sharing between detectors through careful optimization of a patterned molybdenum absorber mask. A geological application demonstrates the capability of the method to produce high definition elemental images up to {approx}100 M pixels in size.

43 PARTICLE ACCELERATORS↗

WE-EF-207-06: Dedicated Cone-Beam Breast CT with Laterally-Shifted Detector: Monte Carlo Evaluation of X-Ray Scatter Distribution and Scatter-To-Primary Ratio

Purpose: To determine the spatial distribution of x-ray scatter and scatter-to-primary ratio (SPR) in projections during cone-beam breast CT (CBBCT) with laterally-shifted detector that results in coronal (fan-angle) truncation. Methods: We hypothesized that CBBCT with coronal truncation would lower SPR due to reduction in irradiated breast volume, and that the location of maximum x-ray scatter fluence (scatter-peak) in the detector plane can be determined from the ratio of irradiated-to-total breast volume, breast dimensions and system geometry. Monte Carlo simulations (GEANT4) reflecting a prototype CBBCT system were used to record the position-dependent primary and scatter x-ray photon fluence incident on the detector without coronal truncation (full fan-angle, 2f=24-degrees) and with coronal truncation (fan-angle, f+ f=12+2.7-degrees). Semi-ellipsoidal breasts (10/14/18-cm diameter, chest-wall to nipple length: 0.75xdiameter, 2%/14%/100% fibroglandular content) aligned with the axis-of-rotation (AOR) were modeled. Mono-energy photons were simulated and weighted for 2 spectra (49kVp, 1.4-mm Al HVL; 60kVp, 3.76-mm Al HVL). In addition to SPR, the scatter maps were analyzed to identify the location of the scatter-peak. Results: For CBBCT without fan-angle truncation, the scatter-peaks were aligned with the projection of the AOR onto the detector for all breasts. With truncated fan-beam, the scatter-peaks were laterally-shifted from the projection of the AOR along the fan-angle direction by 14/38/70-pixels for 10/14/18-cm diameter breasts. The corresponding theoretical shifts were 14.8/39.7/68-pixels (p=0.47, 2-tailed paired-ratio t-test). Along the cone-angle, the shift in scatter-peaks between truncated and full-fan angle CBBCT were 2/2/4 -pixels for 10/14/18-cm diameter breasts. CBBCT with fan-angle truncation reduced SPR by 14/22/28% for 10/14/18-cm diameter breasts. 60kVp reduced SPR by 21–25% compared to 49kVp. Peak SPR for CBBCT with fan-angle truncation (60kVp) were 0.09/0.25/0.73 for 10/14/18-cm diameter breasts. Conclusion: CBBCT with laterally-shifted detector geometry and with appropriate kVp/beam quality reduces SPR. If residual scatter needs correction, the location corresponding to scatter-peak can be analytically computed. This work was supported in part by NIH R01 CA128906. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or NCI.

60 APPLIED LIFE SCIENCES↗

Detection of atomic and molecular mega-electron-volt projectiles using an x-ray charged coupled device camera

We show that an x-ray charge coupled device (CCD) may be used as a particle detector for atomic and molecular mega-electron-volt (MeV) projectiles of around a few hundred keV per atomic mass unit. For atomic species, spectroscopic properties in kinetic energy measurements (i.e., linearity and energy resolution) are found to be close to those currently obtained with implanted or surface barrier silicon particle detectors. For molecular species, in order to increase the maximum kinetic energy detection limit, we propose to put a thin foil in front of the CCD. This foil breaks up the molecules into atoms and spreads the charges over many CCD pixels and therefore avoiding saturation effects. This opens new perspectives in high velocity molecular dissociation studies with accelerator facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared Camera System for Visualization of IR-Absorbing Gas Leaks

Leak detection and location remain a common problem in NASA and industry, where gas leaks can create hazardous conditions if not quickly detected and corrected. In order to help rectify this problem, this design equips an infrared (IR) camera with the means to make gas leaks of IR-absorbing gases more visible for leak detection and location. By comparing the output of two IR cameras (or two pictures from the same camera under essentially identical conditions and very closely spaced in time) on a pixel-by-pixel basis, one can cancel out all but the desired variations that correspond to the IR absorption of the gas of interest. This can be simply done by absorbing the IR lines that correspond to the gas of interest from the radiation received by one of the cameras by the intervention of a filter that removes the particular wavelength of interest from the "reference" picture. This can be done most sensitively with a gas filter (filled with the gas of interest) placed in front of the IR detector array, or (less sensitively) by use of a suitable line filter in the same location. This arrangement would then be balanced against the unfiltered "measurement" picture, which will have variations from IR absorption from the gas of interest. By suitable processing of the signals from each pixel in the two IR pictures, the user can display only the differences in the signals. Either a difference or a ratio output of the two signals is feasible. From a gas concentration viewpoint, the ratio could be processed to show the column depth of the gas leak. If a variation in the background IR light intensity is present in the field of view, then large changes in the difference signal will occur for the same gas column concentration between the background and the camera. By ratioing the outputs, the same signal ratio is obtained for both high- and low-background signals, even though the low-signal areas may have greater noise content due to their smaller signal strength. Thus, one embodiment would use a ratioed output signal to better represent the gas column concentration. An alternative approach uses a simpler multiplication of the filtered signal to make the filtered signal equal to the unfiltered signal at most locations, followed by a subtraction to remove all but the wavelength-specific absorption in the unfiltered sample. This signal processing can also reveal the net difference signal representing the leaking gas absorption, and allow rapid leak location, but signal intensity would not relate solely to gas absorption, as raw signal intensity would also affect the displayed signal. A second design choice is whether to use one camera with two images closely spaced in time, or two cameras with essentially the same view and time. The figure shows the two-camera version. This choice involves many tradeoffs that are not apparent until some detailed testing is done. In short, the tradeoffs involve the temporal changes in the field picture versus the pixel sensitivity curves and frame alignment differences with two cameras, and which system would lead to the smaller variations from the uncontrolled variables.

Youngquist, Robert↗

SU-F-I-08: CT Image Ring Artifact Reduction Based On Prior Image

Purpose: In computed tomography (CT) system, CT images with ring artifacts will be reconstructed when some adjacent bins of detector don’t work. The ring artifacts severely degrade CT image quality. We present a useful CT ring artifacts reduction based on projection data correction, aiming at estimating the missing data of projection data accurately, thus removing the ring artifacts of CT images. Methods: The method consists of ten steps: 1) Identification of abnormal pixel line in projection sinogram; 2) Linear interpolation within the pixel line of projection sinogram; 3) FBP reconstruction using interpolated projection data; 4) Filtering FBP image using mean filter; 5) Forwarding projection of filtered FBP image; 6) Subtraction forwarded projection from original projection; 7) Linear interpolation of abnormal pixel line area in the subtraction projection; 8) Adding the interpolated subtraction projection on the forwarded projection; 9) FBP reconstruction using corrected projection data; 10) Return to step 4 until the pre-set iteration number is reached. The method is validated on simulated and real data to restore missing projection data and reconstruct ring artifact-free CT images. Results: We have studied impact of amount of dead bins of CT detector on the accuracy of missing data estimation in projection sinogram. For the simulated case with a resolution of 256 by 256 Shepp-Logan phantom, three iterations are sufficient to restore projection data and reconstruct ring artifact-free images when the dead bins rating is under 30%. The dead-bin-induced artifacts are substantially reduced. More iteration number is needed to reconstruct satisfactory images while the rating of dead bins increases. Similar results were found for a real head phantom case. Conclusion: A practical CT image ring artifact correction scheme based on projection data is developed. This method can produce ring artifact-free CT images feasibly and effectively.

60 APPLIED LIFE SCIENCES↗

A Performance Comparison for Two Versions of the Vulcan Photometer

Analysis of the images produced by the first version (V1) of the Vulcan photometer indicated that two major sources of noise were sky brightness and image motion. To reduce the effect of the sky brightness, a second version (V2) with a longer focal length and a larger format detector was developed and tested. The first version consisted of 15-centimeter (cm) focal length, F/1.5 Aerojet Delft reconnaissance lens, and a 2048 x 2048 format front-illuminated charged coupled device (CCD) with 9 microns micropixels (Mpixels). The second version used a 30-cm focal length, F/2.5 Kodak AeroEktar lens, and a 4096 x 4096 format CCD with 9 micro pixels. Both have a 49-square-degree field of view (FOV) but the area of the sky subtended by each pixel in the V2 version is one-fourth that of the V1 version. This modification substantially reduces the shot noise due to the sky background and allows fainter stars to be monitored for planetary transits. To remove the data gap and consequent signal-level change caused by flipping the photometer around the declination axis and to reduce image movement on the detector, several other modifications were incorporated. These include modifying the mount and stiffening the photometer and autoguider structures to reduce flexure. This paper compares the performance characteristics of each photometer and discusses tests to identify sources of systematic noise.

Borucki, W. J.↗

Neutron Detection in the DUNE liquid argon near Detector

DUNE is a next-generation long baseline neutrino experiment [1] to perform precision measurements of neutrino oscillations. The Liquid Argon Time Projection Chamber (LArTPC) of the DUNE near detector (ND-LAr) characterizes the beam before oscillations occur and is essential to constrain the systematic uncertainties of most DUNE measurements. ND-LAr will be a modular LArTPC with pixelated charge and high-coverage light readout system

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Centroid tracking with area array detectors

A computer program (ALGEVAL) has been developed to simulate the position estimating behavior of a centroid estimator algorithm using data typical of optical point spread function data recorded by an area array detector. Typical results are shown of varying detector properties and optical point spread function types. The detector parameters currently available for study include read noise mean value, dark current mean value and spatial variation, charge transfer efficiency and point spread function location, saturation level, signal level and pixel size. The program is capable of calculating any order centroid using an array size from 2 x 2 to 15 x 15 pixels. The output of the program is either a performance map, histogram data or tabluar data. A number of further developments are recommended.

Glavich, T. A.↗

Nature's crucible: Manufacturing optical nonlinearities for high resolution, high sensitivity encoding in the compound eye of the fly, Musca domestica

The number of pixels per unit area sampling an image determines Nyquist resolution. Therefore, the highest pixel density is the goal. Unfortunately, as reduction in pixel size approaches the wavelength of light, sensitivity is lost and noise increases. Animals face the same problems and have achieved novel solutions. Emulating these solutions offers potentially unlimited sensitivity with detector size approaching the diffraction limit. Once an image is 'captured', cellular preprocessing of information allows extraction of high resolution information from the scene. Computer simulation of this system promises hyperacuity for machine vision.

Wilcox, Mike↗

FIFI: The MPE Garching/UC Berkeley Far-Infrared Imaging Fabry-Perot Interferometer

We describe the performance characteristics of the MPE Garching/UC Berkeley Far-Infrared Imaging Fabry-Perot Interferometer (FIFI) for the Kuiper Airborne Observatory (KAO). The spectrometer features two or three cryogenic tunable Fabry-Perot filters in series giving spectral resolution R of up to 10(exp 5) in the range of 40 microns less than lambda less than 200 microns, and an imaging 5x5 array of photoconductive detectors with variable focal plane plate scale. The instrument works at background limited sensitivity of up to 2 x 10(exp -19) W cm(exp -2) Hz(exp -1/2) per pixel per resolution element at R = 10(exp 5) on the KAO.

Geis, Norbert↗

Refine your search to explore more results.