Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

The solution of radiative transfer problems in molecular bands without the LTE assumption by accelerated lambda iteration methods

An iterative method based on the use of approximate transfer operators, which was designed initially to solve multilevel NLTE line formation problems in stellar atmospheres, is adapted and applied to the solution of the NLTE molecular band radiative transfer in planetary atmospheres. The matrices to be constructed and inverted are much smaller than those used in the traditional Curtis matrix technique, which makes possible the treatment of more realistic problems using relatively small computers. This technique converges much more rapidly than straightforward iteration between the transfer equation and the equations of statistical equilibrium. A test application of this new technique to the solution of NLTE radiative transfer problems for optically thick and thin bands (the 4.3 micron CO2 band in the Venusian atmosphere and the 4.7 and 2.3 micron CO bands in the earth's atmosphere) is described.

Kutepov, A. A.↗

High frequency scattering from trihedral corner reflectors and other benchmark targets - SBR versus experiment

A general method for calculating the radar cross section (RCS) from a three-dimensional target is described. The target is first constructed by using a solid-geometry-modeling computer-aided design (CAD) package. Following the shooting and bouncing ray (SBR) method, a very dense grid of rays is launched from the incident direction toward the target. Each ray is traced according to the geometrical optics theory including the effect of ray tube divergence, polarization, and material reflection coefficient. At the point where the ray exits the target, a physical optics-type integration is performed to obtain the scattered far fields. This method is tested using several simple examples involving interaction among plates, cylinders, and spheres. The theoretical results are generally in good agreement with measured data.

Baldauf, John↗

Portable, solid state, fiber optic coupled Doppler interferometer system for detonation and shock diagnostics

VISAR (Velocity Interferometer System for Any Reflector) is a specialized Doppler interferometer system that is gaining world-wide acceptance as the standard for shock phenomena analysis. The VISAR's large power and cooling requirements, and the sensitive and complex nature of the interferometer cavity have restricted the traditional system to the laboratory. This paper describes the new portable VISAR, its peripheral sensors, and the role it played in optically measuring ground shock of and underground nuclear detonation. The Solid State VISAR uses a prototype diode pumped Nd:YAG laser and solid state detectors that provide a suitcase-size system with low power requirements. A special window and sensors were developed for fiber optic coupling (1 kilometer long) to the VISAR. The system has proven itself as a reliable, easy to use instrument that is capable of field test use and rapid data reduction using only a notebook personal computer (PC).

Fleming, K. J.↗

Reducing the Requirements and Cost of Astronomical Telescopes

Limits on astronomical telescope apertures are being rapidly approached. These limits result from logistics, increasing complexity, and finally budgetary constraints. In an historical perspective, great strides have been made in the area of aperture, adaptive optics, wavefront sensors, detectors, stellar interferometers and image reconstruction. What will be the next advances? Emerging data analysis techniques based on communication theory holds the promise of yielding more information from observational data based on significant computer post-processing. This paper explores some of the current telescope limitations and ponders the possibilities increasing the yield of scientific data based on the migration computer post-processing techniques to higher dimensions. Some of these processes hold the promise of reducing the requirements on the basic telescope hardware making the next generation of instruments more affordable.

Smith, W. Scott↗

Evaluation of Alternate Concepts for Synthetic Vision Flight Displays With Weather-Penetrating Sensor Image Inserts During Simulated Landing Approaches

A simulation study was conducted in 1994 at Langley Research Center that used 12 commercial airline pilots repeatedly flying complex Microwave Landing System (MLS)-type approaches to parallel runways under Category IIIc weather conditions. Two sensor insert concepts of 'Synthetic Vision Systems' (SVS) were used in the simulated flights, with a more conventional electro-optical display (similar to a Head-Up Display with raster capability for sensor imagery), flown under less restrictive visibility conditions, used as a control condition. The SVS concepts combined the sensor imagery with a computer-generated image (CGI) of an out-the-window scene based on an onboard airport database. Various scenarios involving runway traffic incursions (taxiing aircraft and parked fuel trucks) and navigational system position errors (both static and dynamic) were used to assess the pilots' ability to manage the approach task with the display concepts. The two SVS sensor insert concepts contrasted the simple overlay of sensor imagery on the CGI scene without additional image processing (the SV display) to the complex integration (the AV display) of the CGI scene with pilot-decision aiding using both object and edge detection techniques for detection of obstacle conflicts and runway alignment errors.

Parrish, Russell V.↗

Cloud Microphysics and Absorption Validation

Vertical distributions of particle size and habit were developed from in-situ data collected from three midlatitude cirrus field campaigns (FIRE-1, FIRE-2, and ARM IOP). These new midlatitude microphysical models were used to develop new cirrus scattering models at a number of wavelengths appropriate for use with the MODIS imager (Nasiri et al. 2002). This was the first successful collaborative effort between all the investigators on this proposal. Recent efforts have extended the midlatitude cirrus cloud analyses to tropical cirrus, using in-situ data collected during the Tropical Rainfall Measurement Mission (TRMM) Kwajalein field campaign in 1999. We note that there are critical aspects to the work: a) Improvement in computing the scattering and radiative properties of ice crystals; b) Requirement for copious amounts of cirrus in-situ data, presented in terms of both particle size and habit distributions; c) Development of cirrus microphysical and optical models for various satellite, aircraft, and ground-based instruments based on the theoretical calculations and in-situ measurements; d) Application to satellite data.

Ackerman, Steven↗

Biosensors for EVA: Improved Instrumentation for Ground-based Studies

During lunar excursions in the EVA suit, real-time measurement of metabolic rate is required to manage consumables and guide activities to ensure safe return to the base. Metabolic rate, or oxygen consumption (VO2), is normally measured from pulmonary parameters but cannot be determined with standard techniques in the oxygen-rich environment of a spacesuit. Our group has developed novel near infrared spectroscopic (NIRS) methods to calculate muscle oxygen saturation (SmO 2), hematocrit, and pH, and we recently demonstrated that we can use our NIRS sensor to measure VO 2 on the leg during cycling. Our NSBRI project has 4 objectives: (1) increase the accuracy of the metabolic rate calculation through improved prediction of stroke volume; (2) investigate the relative contributions of calf and thigh oxygen consumption to metabolic rate calculation for walking and running; (3) demonstrate that the NIRS-based noninvasive metabolic rate methodology is sensitive enough to detect decrement in VO 2 in a space analog; and (4) improve instrumentation to allow testing within a spacesuit. Over the past year we have made progress on all four objectives, but the most significant progress was made in improving the instrumentation. The NIRS system currently in use at JSC is based on fiber optics technology. Optical fiber bundles are used to deliver light from a light source in the monitor to the patient, and light reflected back from the patient s muscle to the monitor for spectroscopic analysis. The fiber optic cables are large and fragile, and there is no way to get them in and out of the test spacesuit used for ground-based studies. With complimentary funding from the US Army, we undertook a complete redesign of the sensor and control electronics to build a novel system small enough to be used within the spacesuit and portable enough to be used by a combat medic. In the new system the filament lamp used in the fiber optic system was replaced with a novel broadband near infrared LED light source. The compact grating spectrometer was replaced with a chip-scale spectrometer. With this new design, the sensor is 4 in 2 in 0.5 in, weighs 60 g, and no fiber optic cables are needed. The sensor, which contains the light source and the spectrometer, is adhered directly to the skin with medical grade adhesive. The sensor can be powered via the USB port of the laptop computer that controls the sensor operation. Alternatively, for studies in the spacesuit, the sensor can be powered by a small battery pack and operated by an ultra-portable hand-held computer. Both the handheld computer and battery pack will easily fit within the PLSS of the test spacesuit. System automation was significantly improved, to add features suggested by our colleagues in the Cardiovascular Laboratory and the NASA JSC Exercise Physiology and Countermeasures Project. The functionality and portability of this system were demonstrated in our UMass laboratory.

Soller, B.↗

Recovery, Transportation and Acceptance to the Curation Facility of the Hayabusa Re-Entry Capsule

The "Hayabusa" re-entry capsule was safely carried into the clean room of Sagamihara Planetary Sample Curation Facility in JAXA on June 18, 2010. After executing computed tomographic (CT) scanning, removal of heat shield, and surface cleaning of sample container, the sample container was enclosed into the clean chamber. After opening the sample container and residual gas sampling in the clean chamber, optical observation, sample recovery, sample separation for initial analysis will be performed. This curation work is continuing for several manths with some selected member of Hayabusa Asteroidal Sample Preliminary Examination Team (HASPET). We report here on the 'Hayabusa' capsule recovery operation, and transportation and acceptance at the curation facility of the Hayabusa re-entry capsule.

Abe, M.↗

Optimization of OT-MACH Filter Generation for Target Recognition

An automatic Optimum Trade-off Maximum Average Correlation Height (OT-MACH) filter generator for use in a gray-scale optical correlator (GOC) has been developed for improved target detection at JPL. While the OT-MACH filter has been shown to be an optimal filter for target detection, actually solving for the optimum is too computationally intensive for multiple targets. Instead, an adaptive step gradient descent method was tested to iteratively optimize the three OT-MACH parameters, alpha, beta, and gamma. The feedback for the gradient descent method was a composite of the performance measures, correlation peak height and peak to side lobe ratio. The automated method generated and tested multiple filters in order to approach the optimal filter quicker and more reliably than the current manual method. Initial usage and testing has shown preliminary success at finding an approximation of the optimal filter, in terms of alpha, beta, gamma values. This corresponded to a substantial improvement in detection performance where the true positive rate increased for the same average false positives per image.

false alarm reduction↗

Infrared Spectral Responses of the Ocean Color Instrument (OCI) Pre-assembly and Integration

The Ocean Color Instrument (OCI) to go on the Plankton, Aerosol, Cloud, ocean Ecology (PACE) Earth-observing satellite has a Short-wave infrared (SWIR) Detection Assembly (SDA). This SDA is used to measure upwelling radiation in seven discrete bands from 940 to 2260 nm. There are redundant measurements of each band for a total of 32 physical channels, which includes optical components through to detection. The relative spectral response (RSR) is measured for each channel, which is needed when accounting for the spectral distribution of sensed radiance. From the RSR, single-value performance metrics are computed including the center wavelength, the full width at half of the maximum (FWHM), and the full width at 1% of the maximum (FW1P). Besides in-band responses, the out-of-band rejection ratio (OOBRR) is also calculated for each of the channels, which is a measure of the sensitivity outside the band of interest. We find that all 32 SDA detection channels meet the spectral response requirements at the qualification temperatures at which tests were conducted.

PACE↗

Spectral Responses of the PACE OCI Short-Wave Infrared Detection Assembly

The Ocean Color Instrument (OCI) to go on the Plankton, Aerosol, Cloud, ocean Ecology (PACE) Earth-observing satellite has a Short-wave infrared (SWIR) Detection Assembly (SDA). This SDA is used to measure upwelling radiation in seven discrete bands from 940 to 2260 nm. There are redundant measurements of each band for a total of 32 physical channels, which includes optical components through to detection. The relative spectral response (RSR) is measured for each channel, which is needed when accounting for the spectral distribution of sensed radiance. From the RSR, single-value performance metrics are computed including the center wavelength, the full width at half of the maximum (FWHM), and the full width at 1% of the maximum (FW1P). Besides in-band responses, the out-of-band rejection ratio (OOBRR) is also calculated for each of the channels, which is a measure of the sensitivity outside the band of interest. We find that all 32 SDA detection channels meet the spectral response requirements at the qualification temperatures at which tests were conducted.

PACE↗

Geoscience Laser Altimeter System: Characteristics and Performance of the Altimeter Receiver

The Geoscience Laser Altimeter System (GLAS) on board ICESat spacecraft measures the surface height (altimetry) via the time of flight of its 1064 nm laser pulse. The GLAS laser transmitter produces 6 ns wide pulses with 70 mJ energy at 1064 nm at a 40 Hz rate. The altimeter receiver consists of a telescope, aft optics, a silicon avalanche photodiode, and electronic amplifiers. The transmitted and echo pulse waveforms are digitized at 1 GHz rate. The laser pulse time of flight is determined on the ground from the two digitized pulse waveforms and their positions in the full waveform record (about 5.4 ms ong) by computing the pulse centroids or by curve fitting. The GLAS receiver algorithms in on board software selects the two waveform segments containing the transmitted and the echo pulses and sends them to ground. The probability of echo pulse detection and the accuracy of time of flight measurement depend on the received signal level, the background light within the receiver field of view, the inherent detector and amplifier noise, the quantization of the digitizer, and some times by cloud obscurations. A receiver model has been developed to calculate the probability of detection and accuracy of the altimeter measurements with these noise sources. From prelaunch testing, the minimum detectable echo pulse energy for 90% detection probability was about 0.1 fj/pulse onto the detector. Such a receiver sensitivity allows GLAS to measure the surface height through clouds with optical density less than 2. The echo pulse energy required to achieve 10 cm ranging accuracy was found to be about 3 times higher than the minimum detectable signal level. The smallest single shot range measurement error, which was determined by ranging to a fixed target with strong echo pulses and no background light, was 2 to 3cm. The maximum linear response echo pulse energy was 10 fJ/pulse for the strongest echo signals, assuming a Lambertian scattering snow surface, clear sky atmosphere transmission, and no pulse width spreading due to surface slopes. Results from the initial 38 days of GLAS operation on-orbit with Laser 1, showed the echo pulse energies varied, as expected, over a wide dynamic range due to the variability of atmosphere transmission and Earth surface characteristics. The receiver was able to reliably detect the ground surface echoes and measure time of flight under such dynamic conditions, except when there were dense clouds. When over Antarctica, the echo pulse energies were several times stronger than predicted. This suggests that the 1064 nm backscattering from the snow pack and ice-sheet &ce are not completely Lambertian but is somewhat peaked at opposit.ion. With Laser 1, the peak amplitude of the echo pulses from flat ice sheets under clear sky conditions exceeded the linear response range of the receiver, causing some pulse waveform distortion due to saturation. We have characterized the effects of receiver saturation on the time of flight, pulse width, and pulse energy measurements for flat surface by testing a night spare detector in the lab with simulated echo pulses. A data processing algorithm that minimizes the errors due to saturation for these measurements are described.

Sun, Xiao-Li↗

Optimization studies in the support design for the Large Space Telescope.

A two-stage computer-oriented process is described to design the optimum mirror supports for the NASA Large Space Telescope. Using an element model for the mirror, a set of support displacements is determined so as to minimize the rms optical surface disturbances with respect to a best-fit surface. The second stage uses the STRUDL II-STOP finite element optimization system (a branch and bound approach) to obtain a minimum weight design for the support structure subject to the displacement constraints.

Cella, A.↗

Michigan experimental multispectral mapping system: A description of the M7 airborne sensor and its performance

The development and characteristics of a multispectral band scanner for an airborne mapping system are discussed. The sensor operates in the ultraviolet, visual, and infrared frequencies. Any twelve of the bands may be selected for simultaneous, optically registered recording on a 14-track analog tape recorder. Multispectral imagery recorded on magnetic tape in the aircraft can be laboratory reproduced on film strips for visual analysis or optionally machine processed in analog and/or digital computers before display. The airborne system performance is analyzed.

Hasell, P. G., Jr.↗

Effect of molecular anisotropy on the intensity and degree of polarization of light scattered from model atmospheres

Computations of the intensity, flux, degree of polarization, and the positions of neutral points are presented for models of the terrestrial gaseous and hazy atmospheres by incorporating the molecular anisotropy due to air in the Rayleigh scattering optical thickness and phase matrix. Molecular anisotropy causes significant changes in the intensity, flux and the degree of polarization of the scattered light. The positions of neutral points do not change significantly. When the Rayleigh scattering optical thickness is kept constant and the molecular anisotropy factor is included only in the Rayleigh phase matrix, the flux does not change and the intensity and positions of neutron points change by a small amount. The changes in the degree of polarization are still significant.

Bahethi, O. P.↗

Development and evaluation of a Hadamard transform imaging spectrometer and a Hadamard transform thermal imager

A spectrometric imager and a thermal imager, which achieve multiplexing by the use of binary optical encoding masks, were developed. The masks are based on orthogonal, pseudorandom digital codes derived from Hadamard matrices. Spatial and/or spectral data is obtained in the form of a Hadamard transform of the spatial and/or spectral scene; computer algorithms are then used to decode the data and reconstruct images of the original scene. The hardware, algorithms and processing/display facility are described. A number of spatial and spatial/spectral images are presented. The achievement of a signal-to-noise improvement due to the signal multiplexing was also demonstrated. An analysis of the results indicates both the situations for which the multiplex advantage may be gained, and the limitations of the technique. A number of potential applications of the spectrometric imager are discussed.

Harwit, M.↗

Applications of advanced electric/electronic technology to conventional aircraft

The desirability of seven advanced technologies as applied to three commercial aircraft of 1985 to 1995 was investigated. Digital fly by wire, multiplexing, ring laser gyro, integrated avionics, all electric airplane, electric load management, and fiber optics were considered for 500 passenger, 50 passenger, and 30 passenger aircraft. The major figure of merit used was Net Value of Technology based on procurement and operating cost over the life of the aircraft. An existing computer program, ASSET, was used to resize the aircraft and evalute fuel usage and maintenance costs for each candidate configuration. Conclusions were that, for the 500 passenger aircraft, all candidates had a worthwhile payoff with the all electric airplane having a large payoff.

Heimbold, R. L.↗

Updating the limit efficiency of silicon solar cells

The limit efficiency of a silicon solar cell is investigated using an analytical approach. The analytical model is based on the solution of a transport equation for minority carriers derived from the Shockley equations. On the basis of the computations, a 'narrow-region' design approach is suggested for both the front and the back regions of the solar cell. The design relies on low effective surface-recombination velocities, a textured front surface, and an optical internally reflecting back surface. With this approach, the limit efficiency is near 25%, and the optimum cell is 50 to 150 microns thick.

Wolf, M.↗

Refine your search to explore more results.