Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “model checking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Perturbative Stability and Error-Correction Thresholds of Quantum Codes

Topologically ordered phases are stable to local perturbations, and topological quantum error-correcting codes enjoy thresholds to local errors. We connect the two notions of stability by constructing classical statistical mechanics models for decoding general Calderbank-Shor-Steane codes and classical linear codes. Our construction encodes correction success probabilities under uncorrelated bit-flip and phase-flip errors, and simultaneously describes a generalized ℤ 2 lattice-gauge theory with quenched disorder. We observe that the clean limit of the latter is precisely the discretized imaginary-time path integral of the corresponding quantum code Hamiltonian when the errors are turned into a perturbative 𝑋 or 𝑍 magnetic field. Motivated by error-correction considerations, we define general order parameters for all such generalized ℤ 2 lattice-gauge theories, and show that they are generally lower bounded by success probabilities of error correction. For CSS codes satisfying the low-density parity-check condition and with a sufficiently large code distance, we prove the existence of a low-temperature ordered phase of the corresponding lattice-gauge theories, particularly for those lacking Euclidean spatial locality and/or when there is a nonzero code rate. We further argue that these results provide evidence for stable phases in the corresponding perturbed quantum Hamiltonians, obtained in the limit of continuous imaginary time. To do so, we distinguish space- and timelike defects in the lattice-gauge theory. A high free-energy cost of spacelike defects corresponds to a successful “memory experiment” and suppresses the energy splitting among the ground states, while a high free-energy cost of timelike defects corresponds to a successful “stability experiment” and points to a nonzero gap to local excitations.

quantum error correction↗

Cloud Condensation in Titan's Lower Stratosphere

A 1-D condensation model is developed for the purpose of reproducing ice clouds in Titan's lower stratosphere observed by the Composite Infrared Spectrometer (CIRS) onboard Cassini. Hydrogen cyanide (HCN), cyanoacetylene (HC3N), and ethane (C2H6) vapors are treated as chemically inert gas species that flow from an upper boundary at 500 km to a condensation sink near Titan's tropopause (-45 km). Gas vertical profiles are determined from eddy mixing and a downward flux at the upper boundary. The condensation sink is based upon diffusive growth of the cloud particles and is proportional to the degree of supersaturation in the cloud formation regIOn. Observations of the vapor phase abundances above the condensation levels and the locations and properties of the ice clouds provide constraints on the free parameters in the model. Vapor phase abundances are determined from CIRS mid-IR observations, whereas cloud particle sizes, altitudes, and latitudinal distributions are derived from analyses of CIRS far-IR observations of Titan. Specific cloud constraints include: I) mean particle radii of2-3 J.lm inferred from the V6 506 cm- band of HC3N, 2) latitudinal abundance distributions of condensed nitriles, inferred from a composite emission feature that peaks at 160/cm , and 3) a possible hydrocarbon cloud layer at high latitudes, located near an altitude of 60 km, which peaks between 60 and 80 cm l . Nitrile abundances appear to diminish substantially at high northern latitudes over the time period 2005 to 2010 (northern mid winter to early spring). Use of multiple gas species provides a consistency check on the eddy mixing coefficient profile. The flux at the upper boundary is the net column chemical production from the upper atmosphere and provides a constraint on chemical pathways leading to the production of these compounds. Comparison of the differing lifetimes, vapor phase transport, vapor phase loss rate, and particle sedimentation, sheds light on temporal stability of the clouds.

Romani, Paul N.↗

A Search for the 3.5 keV Line from the Milky Way's Dark Matter Halo with HaloSat

Previous detections of an X-ray emission line near 3.5 keV in galaxy clusters and other dark-matter-dominated objects have been interpreted as observational evidence for the decay of sterile neutrino dark matter. Motivated by this, we report on a search for a 3.5 keV emission line from the Milky Way's galactic dark matter halo with HaloSat. As a single pixel, collimated instrument, HaloSat observations are impervious to potential systematic effects due to grazing incidence reflection and CCD pixelization, and thus may offer a check on possible instrumental systematic errors in previous analyses. We report nondetections of a ~3.5 keV emission line in four HaloSat observations near the Galactic center. In the context of the sterile neutrino decay interpretation of the putative line feature, we provide 90% confidence level upper limits on the 3.5 keV line flux for a field centered 18.6 degrees from the Galactic center and the corresponding 7.1 keV sterile neutrino mixing angle: F ≤ 0.077 ph/((sq. cm)(s)(sr)) and sin^2(2θ) ≤ 4.25 x 10^(-11). The HaloSat mixing angle upper limit was calculated using a modern parameterization of the Milky Way's dark matter distribution, and in order to compare with previous limits, we also report the limit calculated using a common historical model. The HaloSat mixing angle upper limit places constraints on a number of previous mixing angle estimates derived from observations of the Milky Way's dark matter halo and galaxy clusters, and excludes several previous detections of the line. The upper limits cannot, however, entirely rule out the sterile neutrino decay interpretation of the 3.5 keV line feature.

E. M. Silich↗

Two Bright M Dwarfs Hosting Ultra-Short-Period Super-Earths with Earth-like Compositions

We present observations of two bright M dwarfs (TOI-1634 and TOI-1685: J = 9.5–9.6) hosting ultra-short-period (USP) planets identified by the TESS mission. The two stars are similar in temperature, mass, and radius (T eff ≈ 3500 K, M ⋆ ≈ 0.45–0.46 M ⊙ , and R ⋆ ≈ 0.45–0.46 R ⊙ ), and the planets are both super-Earth size (1.25 R ⊕ < R p < 2.0 R ⊕ ). For both systems, light curves from ground-based photometry exhibit planetary transits, whose depths are consistent with those from the TESS photometry. We also refine the transit ephemerides based on the ground-based photometry, finding the orbital periods of P = 0.9893436 ± 0.0000020 days and P = 0.6691416 ± 0.0000019 days for TOI-1634b and TOI-1685b, respectively. Through intensive radial velocity (RV) observations using the InfraRed Doppler (IRD) instrument on the Subaru 8.2 m telescope, we confirm the planetary nature of the TOIs and measure their masses: 10.14 ± 0.95 M ⊕ and 3.43 ± 0.93 M ⊕ for TOI-1634b and TOI-1685b, respectively, when the observed RVs are fitted with a single-planet circular-orbit model. Combining those with the planet radii of R p = 1.749 ± 0.079 R ⊕ (TOI-1634b) and 1.459 ± 0.065 R ⊕ (TOI-1685b), we find that both USP planets have mean densities consistent with an Earth-like internal composition, which is typical for small USP planets. TOI-1634b is currently the most massive USP planet in this category, and it resides near the radius valley, which makes it a benchmark planet in the context of discussing the size limit of rocky planet cores as well as testing the formation scenarios for USP planets. Excess scatter in the RV residuals for TOI-1685 suggests the presence of a possible secondary planet or unknown activity/instrumental noise in the RV data, but further observations are required to check those possibilities.

Teruyuki Hirano↗

Development of Software to Model AXAF-I Image Quality

This draft final report describes the work performed under the delivery order number 145 from May 1995 through August 1996. The scope of work included a number of software development tasks for the performance modeling of AXAF-I. A number of new capabilities and functions have been added to the GT software, which is the command mode version of the GRAZTRACE software, originally developed by MSFC. A structural data interface has been developed for the EAL (old SPAR) finite element analysis FEA program, which is being used by MSFC Structural Analysis group for the analysis of AXAF-I. This interface utility can read the structural deformation file from the EAL and other finite element analysis programs such as NASTRAN and COSMOS/M, and convert the data to a suitable format that can be used for the deformation ray-tracing to predict the image quality for a distorted mirror. There is a provision in this utility to expand the data from finite element models assuming 180 degrees symmetry. This utility has been used to predict image characteristics for the AXAF-I HRMA, when subjected to gravity effects in the horizontal x-ray ground test configuration. The development of the metrology data processing interface software has also been completed. It can read the HDOS FITS format surface map files, manipulate and filter the metrology data, and produce a deformation file, which can be used by GT for ray tracing for the mirror surface figure errors. This utility has been used to determine the optimum alignment (axial spacing and clocking) for the four pairs of AXAF-I mirrors. Based on this optimized alignment, the geometric images and effective focal lengths for the as built mirrors were predicted to cross check the results obtained by Kodak.

Ahmad, Anees↗

NASA Tech Briefs, May 2010

Topics covered include: Instrument for Analysis of Greenland's Glacier Mills Cryogenic Moisture Apparatus; A Transportable Gravity Gradiometer Based on Atom Interferometry; Three Methods of Detection of Hydrazines; Crossed, Small-Deflection Energy Analyzer for Wind/Temperature Spectrometer; Wavefront Correction for Large, Flexible Antenna Reflector; Novel Micro Strip-to-Waveguide Feed Employing a Double-Y Junction; Thin-Film Ferro Electric-Coupled Microstripline Phase Shifters With Reduced Device Hysteresis; Two-Stage, 90-GHz, Low-Noise Amplifier; A 311-GHz Fundamental Oscillator Using InP HBT Technology; FPGA Coprocessor Design for an Onboard Multi-Angle Spectro-Polarimetric Imager; Serrating Nozzle Surfaces for Complete Transfer of Droplets; Turbomolecular Pumps for Holding Gases in Open Containers; Triaxial Swirl Injector Element for Liquid-Fueled Engines; Integrated Budget Office Toolbox; PLOT3D Export Tool for Tecplot; Math Description Engine Software Development Kit; Astronaut Office Scheduling System Software; ISS Solar Array Management; Probabilistic Structural Analysis Program; SPOT Program; Integrated Hybrid System Architecture for Risk Analysis; System for Packaging Planetary Samples for Return to Earth; Offset Compound Gear Drive; Low-Dead-Volume Inlet for Vacuum Chamber; Simple Check Valves for Microfluidic Devices; A Capillary-Based Static Phase Separator for Highly Variable Wetting Conditions; Gimballing Spacecraft Thruster; Finned Carbon-Carbon Heat Pipe with Potassium Working Fluid; Lightweight Heat Pipes Made from Magnesium; Ceramic Rail-Race Ball Bearings; Improved OTEC System for a Submarine Robot; Reflector Surface Error Compensation in Dual-Reflector Antennas; Enriched Storable Oxidizers for Rocket Engines; Planar Submillimeter-Wave Mixer Technology with Integrated Antenna; Widely Tunable Mode-Hop-Free External-Cavity Quantum Cascade Laser; Non-Geiger-Mode Single-Photon Avalanche Detector with Low Excess Noise; Using Whispering-Gallery-Mode Resonators for Refractometry; RF Device for Acquiring Images of the Human Body; Reactive Collision Avoidance Algorithm; Fast Solution in Sparse LDA for Binary Classification; Modeling Common-Sense Decisions in Artificial Intelligence; Graph-Based Path-Planning for Titan Balloons; Nanolaminate Membranes as Cylindrical Telescope Reflectors; Air-Sea Spray Airborne Radar Profiler Characterizes Energy Fluxes in Hurricanes; Large Telescope Segmented Primary Mirror Alignment; and Simplified Night Sky Display System.

Source record↗

Distribution Development for Residual Inventory at the New York West Valley Site - 20400

The New York State Energy Research and Development Authority (NYSERDA) is the owner of the Western New York Nuclear Service Center (WNYNSC), a 1,351 ha site located approximately 48 km south of Buffalo, New York. In 1962, Nuclear Fuel Services, Inc. (NFS) entered into Agreements with the Atomic Energy Commission and New York State to construct the first commercial reprocessing plant of nuclear fuel in the United States. NFS, a private company, built and operated the spent fuel reprocessing plant and waste disposal facilities, processing 640 Mg of spent nuclear fuel from 1966 to 1972 under an Atomic Energy Commission license. Nuclear fuel reprocessing operations ended in 1972 and never reopened, leaving behind radioactive and chemical wastes. Operations led to contamination in a number of facilities and locations. Some of that contamination has migrated from waste disposal zones to other layers, formations, and features on and off the WNYNSC. Phase I decommissioning activities are ongoing and involve the removal of a number of areas and structures that have been associated with contamination. The purpose of this work is to outline the approach for characterizing contamination not associated with disposed wastes, contaminated structures, or specific releases. In this work, the term, residual radiological activity, is used to describe environmental contamination that exists subsequent to the completion of Phase I decommissioning activities, that is not associated with disposed wastes, contaminated structures, or specific releases. Contamination from the Site was quantified relative to data that characterize the concentrations of radionuclides that exist in background. Background concentrations are those present in the area but having no influence from Site related activities. The existence of residual radiological activity that is elevated relative to background has the potential to contribute to future risks to human health and the environment. As a consequence, the residual inventory information is used to inform the West Valley Probabilistic Performance Assessment (PPA) model to characterize potential future risks to human health and the environment. The centralized West Valley Data Management System (DMS) was the source of information for the data assembled in this analysis. The DMS is a fairly large compilation consisting of thousands of records from investigation studies, with sample dates ranging from 1990 to present. Samples from monitoring wells, boreholes, geoprobe studies, surface water, surface soils, storm water outfalls, ventilation stack filters, plant and animal tissues, and more are included in the DMS. Results are typically reported in units of activity per unit volume. For the purpose of the analyses presented here, all results were converted into consistent units of pCi per unit volume. Since 1990, data have been collected from various locations across the WNYNSC at different times with varying frequency over the course of several decades. As a consequence, a number of potential issues can arise with respect to the assembly of a dataset that is deemed adequate for the characterization of residual radiological activity. These issues were assessed and resolved to the extent possible through careful consideration of the properties of the distributions. The intent was to use data which characterize the current state of the Site. Radionuclides can be designated to one of several groups depending on their origin. In this work the groups considered were 1) Naturally Occurring Radioactive Material (NORM), 2) fallout, and 3) Other (including power plant, medical research, etc). This grouping is a useful construct with respect to the interpretation of fixed laboratory results. For example, NORM radionuclides that exist within a decay chain should have approximately equivalent distributions of concentrations if they are representative of background conditions. Insights such as these can be used as a check to identify sample results that need to be further investigated or omitted due to issues associated with reported results from fixed laboratory analyses. This type of analysis provided a foundation for the assessment of the adequacy of sample results for use in subsequent components of an assessment. The general process for the assessment of residual radiological contamination at the Site consists of a sequence of several steps. First, for each analyte, several statistical tests were performed to assess the weight of evidence against the null hypothesis that the mean of the distribution of concentrations was equal to zero. If the mean of the distribution of concentrations for a given radionuclide was not found to be greater than zero, then it was removed from consideration as a component of the residual radiological contamination. If there was significant evidence to reject the hypothesis of the mean being equal to zero, the second step was to compare the distribution of the data from the Site to that of the corresponding background. A suite of tests was used to compare the distributions of the site and background data. The results of these tests were collectively used to determine if site data are elevated relative to background. The third step was to develop distributions using a Bayesian framework to characterize the distribution of mean of the increment present above background for each of the radionuclides. The Bayesian model implemented allowed for the comparison of site-specific records to background concentrations to better approximate contamination attributed to the Site. A final screening step was employed for radionuclides that exceed background. This screening step compared 95% upper confidence limits (UCLs) from the increment distribution developed in the previous step to the risk screening levels. This approach yields a list of analytes that were determined to be elevated relative to background.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Two Bright M Dwarfs Hosting Ultra-Short-Period Super-Earths with Earth-like Compositions

We present observations of two bright M dwarfs (TOI-1634 and TOI-1685: J = 9.5–9.6) hosting ultra-short-period (USP) planets identified by the TESS mission. The two stars are similar in temperature, mass, and radius (T {sub eff} ≈ 3500 K, M {sub &middot;} ≈ 0.45–0.46 M {sub ⊙}, and R {sub &middot;} ≈ 0.45–0.46 R {sub ⊙}), and the planets are both super-Earth size (1.25 R {sub ⊕} < R {sub p} < 2.0 R {sub ⊕}). For both systems, light curves from ground-based photometry exhibit planetary transits, whose depths are consistent with those from the TESS photometry. We also refine the transit ephemerides based on the ground-based photometry, finding the orbital periods of P = 0.9893436 ± 0.0000020 days and P = 0.6691416 ± 0.0000019 days for TOI-1634b and TOI-1685b, respectively. Through intensive radial velocity (RV) observations using the InfraRed Doppler (IRD) instrument on the Subaru 8.2 m telescope, we confirm the planetary nature of the TOIs and measure their masses: 10.14 ± 0.95 M {sub ⊕} and 3.43 ± 0.93 M {sub ⊕} for TOI-1634b and TOI-1685b, respectively, when the observed RVs are fitted with a single-planet circular-orbit model. Combining those with the planet radii of R {sub p} = 1.749 ± 0.079 R {sub ⊕} (TOI-1634b) and 1.459 ± 0.065 R {sub ⊕} (TOI-1685b), we find that both USP planets have mean densities consistent with an Earth-like internal composition, which is typical for small USP planets. TOI-1634b is currently the most massive USP planet in this category, and it resides near the radius valley, which makes it a benchmark planet in the context of discussing the size limit of rocky planet cores as well as testing the formation scenarios for USP planets. Excess scatter in the RV residuals for TOI-1685 suggests the presence of a possible secondary planet or unknown activity/instrumental noise in the RV data, but further observations are required to check those possibilities.

47 OTHER INSTRUMENTATION↗

Can an energy balance model provide additional constraints on how to close the energy imbalance?

Elucidating the causes for the energy imbalance, i.e. the phenomenon that eddy covariance latent and sensible heat fluxes fall short of available energy, is an outstanding problem in micrometeorology. This paper tests the hypothesis that the full energy balance, through incorporation of additional independent measurements which determine the driving forces of and resistances to energy transfer, provides further insights into the causes of the energy imbalance and additional constraints on energy balance closure options. Eddy covariance and auxiliary data from three different biomes were used to test five contrasting closure scenarios. The main result of our study is that except for nighttime, when fluxes were low and noisy, the full energy balance generally did not contain enough information to allow further insights into the causes of the imbalance and to constrain energy balance closure options. Up to four out of the five tested closure scenarios performed similarly and in up to 53% of all cases all ofthe tested closure scenarios resulted in plausible energy balance values. Our approach may though provide a sensible consistency check for eddy covariance energy flux measurements.

54 ENVIRONMENTAL SCIENCES↗

Comparison of heavy-ion transport simulations: Collision integral in a box

Simulations by transport codes are indispensable to extract valuable physical information from heavy-ion collisions. In order to understand the origins of discrepancies among different widely used transport codes, we compare 15 such codes under controlled conditions of a system confined to a box with periodic boundary, initialized with Fermi-Dirac distributions at saturation density and temperatures of either 0 or 5 MeV. In such calculations, one is able to check separately the different ingredients of a transport code. In this second publication of the code evaluation project, we only consider the two-body collision term; i.e., we perform cascade calculations. When the Pauli blocking is artificially suppressed, the collision rates are found to be consistent for most codes (to within 1 % or better) with analytical results, or completely controlled results of a basic cascade code. In orderto reach that goal, it was necessary to eliminate correlations within the same pair of colliding particles that can be present depending on the adopted collision prescription. In calculations with active Pauli blocking, the blocking probability was found to deviate from the expected reference values. The reason is found in substantial phase-space fluctuations and smearing tied to numerical algorithms and model assumptions in the representation of phase space. This results in the reduction of the blocking probability in most transport codes, so that the simulated system gradually evolves away from the Fermi-Dirac toward a Boltzmann distribution. Since the numerical fluctuations are weaker in the Boltzmann-Uehling-Uhlenbeck codes, the Fermi-Dirac statistics is maintained there for a longer time than in the quantum molecular dynamics codes. As a result of this investigation, we are able to make judgements about the most effective strategies in transport simulations for determining the collision probabilities and the Pauli blocking. Finally, investigation in a similar vein of other ingredients in transport calculations, like the mean-field propagation or the production of nucleon resonances and mesons, will be discussed in the future publications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MO-PIS-Exhibit Hall-01: Imaging: CT Dose Optimization Technologies I

Partners in Solutions is an exciting new program in which AAPM partners with our vendors to present practical “hands-on” information about the equipment and software systems that we use in our clinics. The imaging topic this year is CT scanner dose optimization capabilities. Note that the sessions are being held in a special purpose room built on the Exhibit Hall Floor, to encourage further interaction with the vendors. Dose Optimization Capabilities of GE Computed Tomography Scanners Presentation Time: 11:15 – 11:45 AM GE Healthcare is dedicated to the delivery of high quality clinical images through the development of technologies, which optimize the application of ionizing radiation. In computed tomography, dose management solutions fall into four categories: employs projection data and statistical modeling to decrease noise in the reconstructed image - creating an opportunity for mA reduction in the acquisition of diagnostic images. Veo represents true Model Based Iterative Reconstruction (MBiR). Using high-level algorithms in tandem with advanced computing power, Veo enables lower pixel noise standard deviation and improved spatial resolution within a single image. Advanced Adaptive Image Filters allow for maintenance of spatial resolution while reducing image noise. Examples of adaptive image space filters include Neuro 3-D filters and Cardiac Noise Reduction Filters. AutomA adjusts mA along the z-axis and is the CT equivalent of auto exposure control in conventional x-ray systems. Dynamic Z-axis Tracking offers an additional opportunity for dose reduction in helical acquisitions while SmartTrack Z-axis Tracking serves to ensure beam, collimator and detector alignment during tube rotation. SmartmA provides angular mA modulation. ECG Helical Modulation reduces mA during the systolic phase of the heart cycle. SmartBeam optimization uses bowtie beam-shaping hardware and software to filter off-axis x-rays - minimizing dose and reducing x-ray scatter. The DICOM Radiation Dose Structured Report (RDSR) generates a dose report at the conclusion of every examination. Dose Check preemptively notifies CT operators when scan parameters exceed user-defined dose thresholds. DoseWatch is an information technology application providing vendor-agnostic dose tracking and analysis for CT (and all other diagnostic x-ray modalities) SnapShot Pulse improves coronary CTA dose management. VolumeShuttle uses two acquisitions to increase coverage, decrease dose, and conserve on contrast administration. Color-Coding for Kids applies the Broselow-Luten Pediatric System to facilitate pediatric emergency care and reduce medical errors. FeatherLight achieves dose optimization through pediatric procedure-based protocols. Adventure Series scanners provide a child-friendly imaging environment promoting patient cooperation with resultant reduction in retakes and patient motion. Philips CT Dose Optimization Tools and Advanced Reconstruction Presentation Time: 11:45 ‘ 12:15 PM The first part of the talk will cover “Dose Reduction and Dose Optimization Technologies” present in Philips CT Scanners. The main Technologies to be presented include: DoseRight and tube current modulation (DoseRight, Z-DOM, 3D-DOM, DoseRight Cardiac) Special acquisition modes Beam filtration and beam shapers Eclipse collimator and ClearRay collimator NanoPanel detector DoseRight will cover automatic tube current selection that automatically adjusts the dose for the individual patient. The presentation will explore the modulation techniques currently employed in Philips CT scanners and will include the algorithmic concepts as well as illustrative examples. Modulation and current selection technologies to be covered include the Automatic Current Selection component of DoseRight, ZDOM longitudinal dose modulation, 3D-DOM (combination of longitudinal and rotational dose modulation), Cardiac Dose right (an ECG based dose modulation scheme), and the DoseRight Index (DRI) IQ index. The special acquisition modes covers acquisition techniques such as prospective gating that is designed to reduce exposure to the patient through the Cardiac Step and Shoot scan mode. This mode can substitute the much higher dose retrospective scan modes for certain types of cardiac imaging. The beam filtration and beam shaper portion will discuss the variety of filtration and beam shaping configurations available on Philips scanners. This topic includes the x-ray beam characteristics, tube filtration as well as dose compensator characteristics. The Eclipse collimator, ClearRay collimator and the NanoPanel detector portion will discuss additional technologies specific to wide coverage CT that address some of the unique challenges encountered and techniques employed to optimize image quality and optimize dose utilization. The Eclipse collimator reduces extraneous exposure by actively blocking the radiation tails at either end of helical scans that do not contribute to the image generation. The ClearRay collimator and the NanoPanel detector optimize the quality of the signal that reaches the detectors by addressing the increased scattered radiation present in wide coverage and the NanoPanel detector adds superior electronic noise characteristics valuable when imaging at a low dose level. The second part of the talk will present “Advanced Reconstruction Technologies” currently available on Philips CT Scanners. The talk will cover filtered back projection (FBP), iDose4 and Iterative Model Reconstruction (IMR). Each reconstruction method will include a discussion of the algorithm as well as similarities and differences between the algorithms. Examples illustrating the merits of each algorithm will be presented, and techniques and metrics to characterize the performance of each type of algorithm will be presented. The Filtered Back projection portion will discuss and provide a brief summary of relevant standard image reconstruction techniques in common use, and discuss the common tradeoffs when using the FBP algorithm. The iDose4 portion will present the algorithms used for iDose4 as well the different levels. The meaning of different levels of iDose4 available will be presented and quantified. Guidelines for selection iDose4 parameters based on the imaging need will be explained. The different image quality goals available with iDose4 and specifically how iDose4 enables noise reduction, spatial resolution improvement or both will be explained. The approaches to leveraging the benefits of iDose4 such as improved spatial resolution, decreased noise, and artifact prevention will be described and quantified; and measurements and metrics behind the improvements will be presented. The image quality benefits in specific imaging situations as well as how to best combine the technology with other dose reduction strategies to ensure the best image quality at a given dose level will be presented. Insight into the IMR algorithm as well as contrast to the iDose4 techniques and performance characteristics will be discussed. Metrics and techniques for characterizing this class of algorithm and IQ performance will be presented. The image quality benefits and the dose reduction capabilities of IMR will be explored. Illustrative examples of the noise reduction, spatial resolution improvement, and low contrast detectability improvements of the reconstruction method will be presented: clinical cases and phantom measurements demonstrating the benefits of IMR in the areas of low dose imaging, spatial resolution and low contrast resolution are discussed and the technical details behind the measurements will be presented compared to both iDose4 and traditional filtered back projection (FBP)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-TeP1-07: Investigation of RapidPlan Based Plan Quality for Breast IMRTSimultaneously Integrated Boost

Purpose: The aim of this study is to investigate the feasibility of using RapidPlan for breast cancer radiotherapy and to evaluate its performance for planners with different planning experiences. Methods: A training database was collected with 80 expert plan datasets from patients previously received left breast conserving surgery and IMRT-simultaneously integrated boost radiotherapy. The models were created on the RapidPlan. Five patients from the training database and 5 external patients were used for internal and external validation, respectively. Three planners with different planning experiences (beginner, junior, senior) designed manual and RapidPlan based plans for additional ten patients. The plan qualities were compared with manual and RapidPlan based ones. Results: For the internal and external validations, there were no significant dose differences on target coverage for plans from RapidPlan and manual. Also, no difference was found in the mean doses to contralateral breast and lung. The RapidPlan improved the heart (V5, V10, V20, V30, and mead dose) and ipsilateral lung (V5, V10, V20, V30, and mean dose) sparing for the beginner and junior planners. Compare to the plans from senior planner, 6 out of 16 clinically checked parameters were improved in RapidPlan, and the left parameters were similar. Conclusion: It is feasible to generate clinical acceptable plans using RapidPlan for breast cancer radiotherapy. The RapidPlan helps to systematically improve the quality of IMRT plans against the benchmark of clinically accepted plans. The RapidPlan shows promise for homogenizing plan quality by transferring planning expertise from more experienced to less experienced planners.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-11: A Virtual Simulator Designed for Collision Prevention in Proton Therapy

Purpose: In proton therapy, collisions between patient and nozzle potentially occur in attaining minimal air gap due to the large nozzle structure. Thus, we developed software predicting the collisions of the nozzle and patient by simulating treatments. Methods: 3D modeling of a gantry inner-floor, nozzle and robotic-couch was done by using the SolidWorks based on the manufacturer’s machine data. To obtain patient body information, a 3D-scanner was utilized to scan a patient right before CT scanning. From the acquired images, a 3D-image of the patient’s body contour was reconstructed. The accuracy of the image was confirmed against the CT image for a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of gantry, nozzle and couch, in real scale. Collision, if any, was examined both in static mode and dynamic mode. The static mode checks only at fixed positions of the machine’s components while dynamic mode examines while one component is in motion. Collision was notified if any voxel of two components, for example a nozzle and a patient or couch, overlapped when calculating volume locations. The event and collision point are visualized and colliding volumes are reported. Results: All components were successfully assembled and the motions could be accurately controlled. The 3D-shape of a phantom agreed with CT images within a deviation of 2 mm. Collision situations can be simulated within minutes and the results are displayed and reported. Conclusion: The developed software will be useful in improving patient safety and clinical efficiency for proton therapy. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning (2012M3A9B6055201, 2013M2A2A7043507), and Samsung Medical Center grant (GFO1130081)

60 APPLIED LIFE SCIENCES↗

Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: METSAT Phase Locked Oscillator Assembly, P/N 1334360-1, S/N's F03 and F04

Two Flight Model AMSU-A Phase Locked Oscillators (P/N 1348360-1, S/Ns F03 and F04) have been tested per AES Test Procedure AE-26758. The tests included vibration testing, thermal cycle testing, AM/FM Noise testing, and full functional testing. EMI/REO 2 Testing was not performed. (See test data for S/N F01). Both AMSU-A Phase Locked Oscillators satisfactorily passed all performance requirements of the AE-26633 Product specification. During thermal cycling of PLO serial number F03, the oven and data logger momentarily lost power, including a loss of data. The unit did not experience any thermal stress. TAR 003134 describes the corrective action. Prior to testing PLO serial number FO4, power was applied to the unit. (+15v,-15v) the unit did not display the proper phase lock. Upon test equipment check out a connector was found to be defective. TAR 003133 describes the corrective action. After completion of testing of PLO serial number F04 was installed into Receiver Assembly F02. Upon testing F02 Receiver Assembly the unit was found not to phase lock at ambient temperature. Removal of PLO Assembly F04 was required. R2 was the real issue. Solithane was secondary. Troubleshooting revealed excessive solithane on inner PLL Assembly cover inhibiting optimum grounding. Also, R2 was reselected which increased the lock range from -30 C to +60 C. TAR 002737 describes the corrective action.

Pines, D.↗

A Pulsar-Based Time-Scale from the International Pulsar Timing Array

We have constructed a new time-scale, TT(IPTA16), based on observations of radio pulsars presented in the first data release from the International Pulsar Timing Array (IPTA). We used two analysis techniques with independent estimates of the noise models for the pulsar observations and different algorithms for obtaining the pulsar time-scale. The two analyses agree within the estimated uncertainties and both agree with TT(BIPM17), a post-corrected time-scale produced by the Bureau International des Poids et Mesures (BIPM). We show that both methods could detect significant errors in TT(BIPM17) if they were present. We estimate the stability of the atomic clocks from which TT(BIPM17) is derived using observations of four rubidium fountain clocks at the US Naval Observatory. Comparing the power spectrum of TT(IPTA16) with that of these fountain clocks suggests that pulsar-based time-scales are unlikely to contribute to the stability of the best time-scales over the next decade, but they will remain a valuable independent check on atomic time-scales. We also find that the stability of the pulsar-based time-scale is likely to be limited by our knowledge of solar-system dynamics, and that errors in TT(BIPM17) will not be a limiting factor for the primary goal of the IPTA, which is to search for the signatures of nano-Hertz gravitational waves.

G. Hobbs↗

Calculation of excitation energies from the CC2 linear response theory using Cholesky decomposition

A new implementation of the approximate coupled cluster singles and doubles CC2 linear response model is reported. It employs a Cholesky decomposition of the two-electron integrals that significantly reduces the computational cost and the storage requirements of the method compared to standard implementations. Our algorithm also exploits a partitioning form of the CC2 equations which reduces the dimension of the problem and avoids the storage of doubles amplitudes. We present calculation of excitation energies of benzene using a hierarchy of basis sets and compare the results with conventional CC2 calculations. The reduction of the scaling is evaluated as well as the effect of the Cholesky decomposition parameter on the quality of the results. The new algorithm is used to perform an extrapolation to complete basis set investigation on the spectroscopically interesting benzylallene conformers. A set of calculations on medium-sized molecules is carried out to check the dependence of the accuracy of the results on the decomposition thresholds. Moreover, CC2 singlet excitation energies of the free base porphin are also presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation Center for Runaway Electron Avoidance and Mitigation (SCREAM SciDAC) (Technical Final Report)

Runaway electrons can severely damage the plasma facing components on ITER during a major disruption and pose a major risk for tokamak fusion. It has been recognized that an adequate disruption mitigation system (DMS) is essential for the safe operation of ITER. The United States is responsible for the design and implementation of the disruption mitigation system on ITER, and in July 2016 the Simulation Center for Runaway Electron Avoidance and Mitigation (SCREAM) was launched by DOE, in a joint Fusion Energy Sciences (FES) and Advanced Scientific Computing Research (ASCR) collaboration. SCREAM was a comprehensive theory and simulation SciDAC center that provided physics guidance in the avoidance and mitigation of runaway electrons, and in tandem with domestic and international experiments, helped establish the qualitative and quantitative bases for safe operational scenarios and viable mitigation techniques. The SCREAM center assembled a national team of experts in runaway electron physics, tokamak disruptions, magnetohydrodynamic (MHD) simulation, and advanced algorithms and computing. The team combined advanced simulation and analysis capability facilitated by direct participation of ASCR SciDAC institutes with theoretical models and code development by FES scientists to focus on the runaway risk for ITER and tokamaks in general. The research scope was focussed on integrated simulations of kinetic runaway electrons, including MHD and fluid models of impurity transport, within a research plan guided by theory. The specific research tasks were (1) establish the fundamental physics of runaway generation, saturation, and dynamical evolution in a tokamak; (2) examine the critical path toward runaway avoidance; and (3) investigate the viability and effectiveness of the leading candidate schemes for runaway mitigation. In all three areas, members of the team carried out scoping studies that established the readiness for rapid and critical advances, especially in the deployment and further development of large-to extreme-scale simulation tools. Our multi-pronged computational approach included (1) relativistic Fokker-Planck solvers with discretization in phase space, (2) self-consistent particle-in-cell techniques, (3) particle-based Monte-Carlo, and (4) MHD-particle hybrid simulations. Cross-check between these different methods provided an additional means for verification and further bolstered the fidelity of our physics prediction. Validation against experimental results brings confidence to the predictive capability for ITER and frequently leads to new ideas for understanding and mitigating the thermal quench driven runaway electron phenomenon.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Processes of interaction of laser radiation with porous transparent materials during their ablation

The effect of ytterbium fibre laser radiation with λ = 1.07 μm on the pressed micropowders of transparent oxides and fluorides (CaF{sub 2}, Y{sub 2}O{sub 3}, Al{sub 2}O{sub 3}, YSZ, etc.) having low absorption coefficients is theoretically studied. Using the numerical modelling, it is established that the radiation scattering in the medium of particles 0.5 – 4.6 μm in diameter leads to the concentration of radiation in the local regions of the medium, with the intensity level exceeding the intensity of the incident radiation (0.46 MW cm{sup −2}) by many times. It is shown that with the growth of the refractive index n of the material from 1.38 (MgF{sub 2}) to 2.12 (YSZ) the intensity of radiation in the region of the strongest local maximum increases from 3.8 to 31 MW cm{sup −2}. In our opinion, this factor can be dominant in determining the possibility of achieving the ablation of such a medium by means of the radiation having an intensity of no greater than 1 MW cm{sup −2}. This hypothesis is experimentally checked by the example of preparing a nanopowder of CaF{sub 2} (n = 1.43) and 1 % Nd : Y{sub 2}O{sub 3} (n = 1.91) by evaporating the pressed target with the porosity 50 % by the continuous-wave radiation of the ytterbium fibre laser with the power 600 W and the intensity 0.4 MW cm{sup −2}. Inside the CaF{sub 2} target, the scattered radiation intensity is smaller than the optical breakdown threshold, and the target is not evaporated. Under the same conditions, the target made of higher-melting 1 % Nd : Y{sub 2}O{sub 3} evaporates well, and the efficiency of the nanopowder production amounts to 23 g h{sup −1}. (interaction of laser radiation with matter)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Refine your search to explore more results.