Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Synthesis and Characterization of Mixed-Conducting Corrosion Resistant Oxide Supports

An extensive search and evaluation of electrochemically stable catalyst supports (including metal oxides like RuO2-SiO2, RuO2-TiO2, and ITO was perfomed during the 4 years of the project. The suports were also catalyzed by deposition of Pt and tested for its performance and electrochemical stability in RDE and fuel cell experiments. For testing the electrochemical stability and fuel cell performance of the catalysts and supports, we have employed the protocols in use at the Department of Energy and Nissan Technological Center North America (NTCNA). The use of such procedures allows a precise and reproducible estimation of the performance and stability of the materials and permits comparisons among laboratories and DOE funded projects. RuO2-SiO2 catalyst supports showed no loss in surface area during start-stop stability tests that were performed by cycling the electrode potential between 0 V to 1.8 V for 1000 cycles. Catalyzed support (40% Pt/RuO2-SiO2; 1:1 mole ratio) were tested in a PEFC, resulting in a current density of 750 mA/cm2 at 0.6 Volts, and a maximum power density of 570 mW/cm2. Measurements were conducted at 80 ºC with 75% relative humidity of the inlet gases (H2/O2); Pt loadings were 0.4 mg/cm2 at the cathode and 0.2 mg/cm2 at the anode. Start-stop stability tests for support and catalyzed support performed in RDE and PEFC set-ups have confirmed RuO2-TiO2 support stability. The beginning of life performance was exactly equal to end of life performance (in an MEA that has been subjected to severe start-stop cycling for 10,000 start/stop cycles between 1 V to 1.5 V). This result was in sharp contrast to baseline Pt/C catalyst that showed significant performance deterioration after accelerated stability tests. The Pt/TRO showed minimal loss in performance upon exposure to start-stop cycles. The loss in cell voltage at 1 A/cm2 at 100% RH was almost 700 mV for Pt/C whereas it was only ca. 15 mV for Pt/TRO. 40% RH data (of inlet gases) revealed a similar trend in terms of stability – exceptional stability for Pt/TRO as opposed to very poor stability for Pt/HSAC. These observations were attributed to the much higher stability of the TRO support compared to Carbon. The carbon dioxide concentration in the cathode exit stream during the accelerated degradation test with Pt/TRO (start-stop protocol) was extremely low (between 3 to 10 ppm of CO2). In contrast, the CO2 emission levels from a conventional Pt/C catalyst were found to be approx. 200 ppm. This observation was a clear indicator that the main source of carbon being oxidized to carbon dioxide in an MEA was the carbon catalyst support, and not the gas diffusion layer or the graphite flow fields. Indium tin oxide (ITO) was also evaluated as a catalyst support for PEFCs. Pt/ITO was very stable under start-up/shutdown accelerated degradation protocol (RDE tests in perchloric acid). The ECSA change was less than 4% over 10,000 cycles. The load cycling accelerated protocol (from 0.6 to 0.95 V vs. RHE) resulted in a loss of approximately 34% of the initial ECSA after 10,000 cycles. However, fuel cell testing resulted in a very low performing catalyst. XPS spectroscopy was employed to investigate the changes in the catalysts occuring during fuel cell operation. It was observed a shift of In 3d5/2 and In 3d3/2 peaks towards higher binding energies. This can be explained by the formation of hydroxides or oxy-hydroxides in the surface of the catalyst. O1s spectrum for Pt/ITO catalyst after being operated in the fuel cell, also confirmed the formation of significant amounts of surface hydroxides (12 to 16%). The presence of surface hydroxides in the catalyst increased the electrode resistivity affecting fuel cell performance. NTCNA performed a detailed analysis of transport phenomena (reactants and products to/from the Pt active sites) in both commercial catalyst and Pt/RTO (in order to have a better understanding at the basic level). The proton resistance (Rionomer) in Pt/C and Pt/RTO cathode catalyst layers were 150 and 12 mΩ-cm2, respectively. Pt/RTO catalyst layer has about an order or magnitude lower proton transfer resistance than Pt/C catalyst layer. Since the ionomer/support ratio that was used in formulating the ink for both catalysts was the same (0.9), it is expected that the volumetric coverage of ionomer of both catalysts will be significantly different due to the disparity in the surface areas (Pt/C had ~ 800 m2/g, while Pt/RTO had ~ 50 m2/g). The differences in the ionomer volumetric coverage and the ionomer film thickness may explain the significantly higher proton conductivity in the Pt/RTO catalyst layer when compared to Pt/HSAC. It is therefore very important to optimize the ionomer loadings when synthesizing new catalyst supports (and never rely on values for carbon-based commercial catalysts). Finally, NTCNA has elaborated a cost model for non-carbon support materials considering their durability benefits. Material costs for production of Pt/ RuO2-TiO2 electrodes were compared to Pt/C. RuO2-TiO2 support was more expensive than carbon but the total material cost was still dominated by platinum cost. Though ruthenium is considered a precious metal, its cost is far less than platinum. It should also be noted that ruthenium only makes up 38% of the mass of the support, while the rest is inexpensive TiO2. After considering the durability advantages of Pt/RTO, cost model showed that even with almost double the Pt loading (0.35 vs 0.18 mgPt/cm2), Pt/RTO ($22.7/kWnet) is only slightly more expensive than Pt/C ($21.9/kWnet).

08 HYDROGEN↗

Cleanup Summary Report for the Defense Threat Reduction Agency Fiscal Year 2007, Task 6.7, U12u-Tunnel (Legacy Site), Nevada Test Site, Nevada

This letter serves as notice of completion for cleanup of the U12u-Tunnel (Legacy Site) as specified in the Defense Threat Reduction Agency (DTRA) Fiscal Year 2007 Statement of Work, Task 6.7. The U12u-Tunnel Legacy Site is located near the intersection of the U12u-Tunnel access road and the U12n-Tunnel access road in Area 12 of the Nevada Test Site (see Figure 1). The site encompasses 1.2 acres and was used to store miscellaneous mining equipment and materials that were used to support DTRA testing in Area 12. Field activities commenced February 11, 2008, and were completed February 20, 2008. Radiological surveys were performed on a drill jumbo and all material stored at the site. The drill jumbo was relocated to U12p-Tunnel portal and consolidated with other critical mining equipment for future use or storage. Ten truck loads of solid waste (53 tons) were shipped to the Nevada Test Site, Area 9 U10c Sanitary Landfill for disposal. No hazardous or radiological waste was generated at this site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Smart technologies enable homes to be efficient and interactive with the grid

Oak Ridge National Laboratory researchers compare two different approaches to test how advanced, energy-efficient building technologies such as smart thermostats, heat pump water heaters, and advanced heat pump HVAC (heating, ventilation and air conditioning) can be optimized within a home and connected at a neighborhood-scale load to a community microgrid in the Alabama Power Smart Neighborhood located in Hoover. Working with Southern Company and Alabama Power, ORNL researchers are pioneering that future where smart homes and smart neighborhoods can benefit both homeowners and utilities, by reducing energy consumption by 44% and peak demand by 34%.This project is one of two neighborhoods in the U.S Department of Energy’s (DOE’s) Connected Neighborhood project, supported by Building Technologies Office , where ORNL researchers leverages DOE investment in micro-grids and responsive, flexible building loads research to improve grid reliability – a goal of DOE’s Grid-interactive Efficient Buildings (GEB) Initiative. Researchers control the neighborhood and microgrid to enable utilities achieve their desired load and cost profiles while ensuring the comfort of homeowners in the Smart Neighborhood. This transactive control approach maximizes the utilization of technical resources of the microgrid and controllable loads, while reducing costs for both the homeowners and Alabama Power. These tests partially seek to determine a more precise range of tolerance with respect to occupant comfort as researchers work to facilitate customer acceptance and perception of new building technologies that enable energy savings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Environmentally assisted cracking in light water reactors.

This report summarizes work performed by Argonne National Laboratory on fatigue and environmentally assisted cracking (EAC) in light water reactors (LWRs) from January to December 2002. Topics that have been investigated include: (a) environmental effects on fatigue crack initiation in carbon and low-alloy steels and austenitic stainless steels (SSs), (b) irradiation-assisted stress corrosion cracking (IASCC) of austenitic SSs in BWRs, (c) evaluation of causes and mechanisms of irradiation-assisted cracking of austenitic SS in PWRs, and (d) cracking in Ni-alloys and welds. A critical review of the ASME Code fatigue design margins and an assessment of the conservation in the current choice of design margins are presented. The existing fatigue {var_epsilon}-N data have been evaluated to define the effects of key material, loading, and environmental parameters on the fatigue lives of carbon and low-alloy steels and austenitic SSs. Experimental data are presented on the effects of surface roughness on fatigue crack initiation in these materials in air and LWR environments. Crack growth tests were performed in BWR environments on SSs irradiated to 0.9 and 2.0 x 10{sup 21} n x cm{sup -2}. The crack growth rates (CGRs) of the irradiated steels are a factor of {approx}5 higher than the disposition curve proposed in NUREG-0313 for thermally sensitized materials. The CGRs decreased by an order of magnitude in low-dissolved oxygen (DO) environments. Slow-strain-rate tensile (SSRT) tests were conducted in high-purity 289 C water on steels irradiated to {approx}3 dpa. The bulk S content correlated well with the susceptibility to intergranular SCC in 289 C water. The IASCC susceptibility of SSs that contain >0.003 wt. % S increased drastically. bend tests in inert environments at 23 C were conducted on broken pieces of SSRT specimens and on unirradiated specimens of the same materials after hydrogen charging. The results of the tests and a review of other data in the literature indicate that IASCC in 289 C water is dominated by a crack-tip grain-boundary process that involves S. An initial IASCC model has been proposed. A crack growth test was completed on mill annealed Alloy 600 in high-purity water at 289 C and 320 C under various environmental and loading conditions. The results from this test are compared with data obtained earlier on several other heats of Alloy 600.

08 HYDROGEN↗

Performance Study of K2CsSb Photocathode Inside a DC High Voltage Gun

In the past decade, there has been considerable interest in the generation of tens of mA average current in a photoinjector. Until recently, GaAs:Cs cathodes and K{sub 2}CsSb cathodes have been tested successfully in DC and RF injectors respectively for this application. Our goal is to test the K{sub 2}CsSb photocathode inside a DC gun. Since the multialkali cathode is a compound with constant characteristics over its entire thickness, we anticipate that the lifetime issues seen in GaAs:Cs due to surface damage by ion bombardment would be minimized. Hence successful operation of the K{sub 2}CsSb cathode in a DC gun could lead to a relatively robust electron source capable of delivering ampere level currents. In order to test the performance of a K{sub 2}CsSb cathode in a DC gun, we have designed and built a load lock system that allows the fabrication of the cathode at Brookhaven National Lab (BNL) and its testing at Jefferson Lab (JLab). In this paper, we will present the performance of the K{sub 2}CsSb photocathode in the preparation chamber and in the DC gun.

43 PARTICLE ACCELERATORS↗

Modeling of ATR Fuel in DOE Standard Canisters with Helium Backfill

One pathway for road-ready and final disposition packaging configurations for the aluminum-clad spent nuclear fuel (ANSF) fuel is storage within helium backfilled sealed Department of Energy (DOE) standard canisters. The typical packaging configuration for the 15-foot DOE standard canisters places 10 advance test reactor (ATR) elements a basket, and three baskets are loaded within each DOE canister. During in-reactor operations and cooling pond storage conditions, oxyhydroxide layers form on the surface of the aluminum clad fuel. These layers produce hydrogen gas over time due to the fuel’s radiation field. As part of the packing procedure, the ATR fuel should be dried to remove any residual physio-/chemi- sorbed water bound to the surface. A 50-year CFD model of the DOE canister packaged with fuel was developed to provide a temperature profile for coupled chemical modeling of the conditions within the canister. The results of this modeling include results at fully saturated and fully dried fuel cladding conditions. In the associated experimental work, radiolysis experiments tests were completed in a helium environment, and G-values for the radiolytic production of hydrogen from the oxyhydroxide layers were provided. That reaction was coupled with the thermal profiles and gas-phase reactions to develop a 50-year model of the conditions within a sealed DOE canister with ATR fuel. For a nominal scenario of stored ATR fuel, after 50 years the model results give a 1.36 atm total pressure, 7% mole percent hydrogen, for the upper decay heat, 1.51 atm total pressure, 16% mole percent hydrogen, and for upper decay heat with undried fuel 2.6 atm total pressure, 15% mole percent hydrogen. No case modeled yields significant oxygen, and for the lower decay heat case that is modeled, hydrogen concentrations are under the 4% flammability limit after 50 years of storage. The modeled pressures for all cases modeled are below the pressure limit for the DOE standard sealed canister.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SMR Re-Scaling and Modeling for Load Following Studies

This study investigates the creation of a new set of scaling parameters for the Oregon State University Multi-Application Small Light Water Reactor (MASLWR) scaled thermal hydraulic test facility. As part of a study being undertaken by Idaho National Lab involving nuclear reactor load following characteristics, full power operations need to be simulated, and therefore properly scaled. Presented here is the scaling analysis and plans for RELAP5-3D simulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Interdiffusion Behavior of U{sub 3}Si{sub 2} and FeCrAl via Diffusion Couple Studies

Uranium Silicide (U{sub 3}Si{sub 2}) is in use as a dispersion plate fuel in test reactors, but has not been fully tested in light water reactor (LWR) conditions. U{sub 3}Si{sub 2} pellets have been fabricated for use in commercial LWRs as part of an accident tolerant fuel system U{sub 3}Si{sub 2} has a higher uranium loading density as well as a higher thermal conductivity relative to UO{sub 2}. FeCrAl alloy is a candidate cladding material to replace the industry standard, Zircaloy. FeCrAl has outstanding high-temperature mechanical strength and oxidation resistance under accident conditions. The U{sub 3}Si{sub 2}-FeCrAl system is expected to provide more than double the amount of time from a Scram until failure criteria for the reactor is met, as well as producing roughly half the amount of H{sub 2} in the event of a loss of coolant accident (LOCA). Uranium and iron have well know eutectics that may affect/enhance diffusion of the U{sub 3}Si{sub 2}/FeCrAl fuel system. The interaction of iron with molten uranium has been investigated In the U-Fe system, UFe{sub 2}, which melts congruently at 1235 deg. C, forms a eutectic with iron that melts at 1080 deg. C and has a composition of U-77at% Fe. UFe{sub 2} also forms a eutectic with uranium that melts at 725 deg. C and has a composition of U-34at% Fe. The U-34at% Fe eutectic extended the temperature range down to 740 deg. C. Regular operating temperatures for U{sub 3}Si{sub 2} fuel is expected to be around 300 - 400 deg. C. The eutectics of iron and uranium would nominally only be of concern in accident scenarios.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Voltage-Load Sensitivity Matrix Based Demand Response for Voltage Control in High Solar Penetration Distribution Feeders

This paper presents a voltage-load sensitivity matrix (VLSM) based voltage control method to deploy demand response resources for controlling voltage in high solar penetration distribution feeders. The IEEE 123-bus system in OpenDSS is used for testing the performance of the preliminary VLSM-based voltage control approach. A load disaggregation process is applied to disaggregate the total load profile at the feeder head to each load nodes along the feeder so that loads are modeled at residential house level. Measured solar generation profiles are used in the simulation to model the impact of solar power on distribution feeder voltage profiles. Different case studies involving various PV penetration levels and installation locations have been performed. Simulation results show that the VLSM algorithm performance meets the voltage control requirements and is an effective voltage control strategy.

distribution system modeling↗

The Wide-area Energy Management System Phase 2 Final Report

The higher penetration of intermittent generation resources (including wind and solar generation) in the Bonneville Power Administration (BPA) and California Independent System Operator (CAISO) balancing authorities (BAs) raises issue of requiring expensive additional fast grid balancing services in response to additional intermittency and fast up and down power ramps in the electric supply system. The overall goal of the wide-area energy management system (WAEMS) project is to develop the principles, algorithms, market integration rules, a functional design, and a technical specification for an energy storage system to help cope with unexpected rapid changes in renewable generation power output. The resulting system will store excess energy, control dispatchable load and distributed generation, and utilize inter-area exchange of the excess energy between the California ISO and Bonneville Power Administration control areas. A further goal is to provide a cost-benefit analysis and develop a business model for an investment-based practical deployment of such a system. There are two tasks in Phase 2 of the WAEMS project: the flywheel field tests and the battery evaluation. Two final reports, the Wide-area Energy Management System Phase 2 Flywheel Field Tests Final Report and the Wide-area Energy Storage and Management System Battery Storage Evaluation, were written to summarize the results of the two tasks.

25 ENERGY STORAGE↗

Comparison of fluence-rate determination techniques for the Advanced Test Reactor-Critical Facility

The Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) is a unique, water-cooled, high-flux test reactor capable of performing tests prototypical of PWR operating conditions. The design and safe operation of experiments in ATR is aided by the operation of the ATR-Critical Facility (ATR-C), a lower-power reactor with the same size and geometry of the ATR. Short, low-power irradiations at the ATR-C are used to study the effects of control devices and test assemblies on the overall power distribution of various core loadings and to compare calculated data for reactor models. A technique was developed at INL to measure fission rates in fuel plate assembly reactors utilizing small, enriched uranium-aluminum (U-Al) alloy monitors, and to support ATR-C irradiations for forty years. Several hundred monitor wires placed throughout the reactor provide fine spatial resolution of the fission rates. A direct correlation exists between the fission rates of the U-Al monitors and the immediately adjacent reactor region. Extensive calibration was previously performed to determine the conversion factor for beta-particle activity of the irradiated U-Al monitors. The fission rate in the U-Al monitors can thus be determined by measuring the beta-particle decay of fission-products following irradiation of the monitors. The American Society for Testing and Materials (ASTM International) has established a standard practice for determining neutron fluence rate by radioactivation of depleted uranium. The ASTM standard practice also measures the concentration of fission-products in the uranium monitors. Rather than measuring the beta-particle decay from fission-products, the decay rate of fission-products is determined by gamma-ray spectroscopy. The feasibility of the ASTM standard practice was investigated for ATR-C irradiations and compared to the present method. The need to analyze hundreds of samples for each irradiation posed several challenges. Therefore, practical considerations such as expected fluence-rates, sample activity, and counting-time were compared between the two methods and the expected sources of error for each method were investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Perovskite-Derived Cs 2 SnCl 6 –Silica Composites as Advanced Waste Forms for Chloride Salt Wastes

Advanced materials and processes are required to separate halides and fission products from complex salt waste streams associated with the chemical reprocessing of used nuclear fuels and molten salt reactor technologies for immobilization into chemically durable waste forms. Here, in this work, we explore an innovative concept using metal-halide perovskites as advanced host phases to incorporate Cs and Cl with very high waste loadings. Wet chemistry-synthesized Cs 2 SnCl 6 powders from CsCl salt solutions are successfully encapsulated into a silica matrix to form a composite using low-temperature spark plasma sintering with tunable Cs and Cl loadings up to 31 wt.% and 26 wt.%, respectively. Chemical durability testing of the composite waste forms by semi-dynamic leaching experiments demonstrates that incongruent leaching mechanism dominated. The metal-halide perovskite-silica composite waste forms display exceptional chemical durability with the long-term release rates of Cs and Cl comparable to or outperforming the state-of-the-art waste form materials but with significantly higher waste loadings. The scalable synthesis of the metal-halide perovskite from wet-chemistry processes opens up new opportunities in designing perovskite-glass composite waste forms for salt wastes with very high waste loadings and exceptional chemical durability for the sustainable development of advanced fuel cycles and next-generation reactor technologies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measured Performance of a Varied Airflow Small-Diameter Duct System

In this study, researchers with the U.S. Department of Energy's Building America team IBACOS built on research previously done in two new-construction unoccupied test houses-one in Pittsburgh, Pennsylvania (Poerschke and Stecher 2014) and one in Fresno, California (Stecher and Poerschke 2013). Specific traditional central air distribution systems were installed in each of these low-load homes. For this study, the cold-climate new-construction unoccupied test house in Pittsburgh, Pennsylvania, was modified to test the performance of a heating, ventilating, and air-conditioning (HVAC) system with varied airflow and small-diameter ducts. The main goal of the small-diameter duct system is to simplify the task of bringing ductwork inside conditioned space, particularly on the single-story slab-on-grade type of home that is prevalent in the South and Southeast. Guidance is provided here to homebuilders and HVAC contractors on cost and performance tradeoffs between the conventional duct system and the small-diameter duct system. Comparisons were made between variable-capacity heat pump operation modes with three constant airflow rates to determine the ideal tradeoff between maximizing thermal comfort and minimizing fan energy consumption. ASHRAE Standard 55 (ASHRAE 2010a) was used to set limit metrics for temporal temperature variation; Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) was used to set a limit on spatial temperature uniformity (room-to-thermostat uniformity). The small diameter duct system was able to meet the temporal temperature variation limits much better than the spatial temperature uniformity limits. TO4 2.1.2: High Velocity Space Cond. Systems

ACCA Manual RS↗

Measuring CO 2 and N 2 O Mass Transfer into GAP-1 CO 2 –Capture Solvents at Varied Water Loadings

This paper investigates the CO 2 and N 2 O absorption behavior in the water-lean gamma amino propyl (GAP)-1/TEG solvent system using a wetted-wall contactor. Testing was performed on a blend of GAP-1 aminosilicone in triethylene glycol at varied water loadings in the solvent. Measurements were made with CO 2 and N 2 O at representative lean (0.04 mol CO 2 /mol alkalinity), middle (0.13 mol CO 2 /mol alkalinity) and rich (0.46 mol CO 2 /mol alkalinity) solvent loadings at 0, 5, 10 and 15 wt% water loadings at 40, 60 and 80C° and N 2 O at (0.08-0.09 mol CO 2 /mol alkalinity) at 5 wt% water at 40, 60 and 80C°. CO 2 flux was found to be non-linear with respect to log mean pressure driving force (LMPD). Liquid-film mass transfer coefficients (k'g) were calculated by subtracting the gas film resistance (determined from a correlation from literature) from the overall mass transfer measurement. The resulting k'g values for CO 2 and N 2 O in GAP-1/TEG mixtures were found to be higher than that of 5M aqueous monoethanolamine under comparable driving force albeit at higher solvent viscosities. The k'g values for CO 2 were also found to decrease with increasing solvent water content and increase with a decrease in temperature. These observations indicate that mass transfer of CO 2 in GAP-1/TEG is linked to the physical solubility of CO 2 , which is higher in organic solvents compared to water. This paper expands on the understanding of the unique mass transfer behavior and kinetics of CO 2 capture in water-lean solvents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design, fabrication, and testing of a getter-based atmosphere purification and waste treatment system for a nitrogen-hydrogen-helium glovebox

A system containing a combination of getters (Zr-Mn-Fe, SAES St909; and Zr{sub 2}Fe, SAES St198) was used to process the nitrogen-hydrogen-helium atmosphere in a glovebox used for handling metal tritide samples. During routine operations, the glovebox atmosphere is recirculated and hydrogenous impurities (i.e. CQ{sub 4}, Q{sub 2}O, and NQ{sub 3}, where Q =H, D, T) are decomposed (cracked) and removed by Zr-Mn-Fe without absorbing elemental hydrogen isotopes. If the tritium content of the glovebox atmosphere becomes unacceptably high, the getter system can rapidly strip the glovebox atmosphere of all hydrogen isotopes by absorption on the Zr{sub 2}Fe, thus lessening the burden on the facility waste gas treatment system. The getter system was designed for high flowrate ( > 100 1/min), which is achieved by using a honeycomb support for the getter pellets and 1.27-cm diameter tubing throughout the system for reduced pressure drop. The novel getter bed design also includes an integral preheater and copper liner to accommodate swelling of the getter pellets, which occurs during loading with oxygen and carbon impurities. Non-tritium functional tests were conducted to determine the gettering efficiencies at different getter bed temperatures and flowrates by recirculating gas through the system from, a 6-m{sup 3} glovebox containing known concentrations of impurities. (authors)

36 MATERIALS SCIENCE↗

AGC-2 Graphite Preirradiation Data Analysis Report (Revision 1)

This report described the specimen loading order and documents all pre-irradiation examination material property measurement data for the graphite specimens contained within the second Advanced Graphite Capsule (AGC-2) irradiation capsule. The AGC-2 capsule is the second in six planned irradiation capsules comprising the Advanced Graphite Creep (AGC) test series. The AGC test series is used to irradiate graphite specimens allowing quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear graphite grades to be generated which will ascertain the in-service behavior of the graphite for pebble bed and prismatic Very High Temperature Reactor (VHTR) designs. Similar to the AGC-1 specimen pre-irradiation examination report, material property tests were conducted on specimens from 18 nuclear graphite types but on an increased number of specimens (512) prior to loading into the AGC-2 irradiation assembly. All AGC-2 specimen testing was conducted at Idaho National Laboratory (INL) from October 2009 to August 2010. This report also details the specimen loading methodology for the graphite specimens inside the AGC-2 irradiation capsule. The AGC-2 capsule design requires “matched pair” creep specimens that have similar dose levels above and below the neutron flux profile mid-plane to provide similar specimens with and without an applied load. This document utilized the neutron flux profile calculated for the AGC-2 capsule design, the capsule dimensions, and the size (length) of the selected graphite and silicon carbide samples to create a stacking order that can produce “matched pairs” of graphite samples above and below the AGC-2 capsule elevation mid-point to provide specimens with similar neutron dose levels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cryogenic RF tests of US LARP DQW SPS-series cavities

Crab cavities are one of the several components included in the luminosity upgrade of the Large Hadron Collider (HL-LHC). For nominal operation, the cavities have to provide a nominal deflecting kick of 3.4 MV per cavity in Continuous Wave operation at 2 K. The requirement for an unjacketed cavity – bare cavity equipped with Higher-Order Mode (HOM) filters and field antenna – is to reach at least a deflecting voltage of 4.1 MV (20% margin) with the heat load to the 2 K bath below 10 W. Cryogenic RF tests confirmed the required performances in bare cavities, with several cavities exceeding the required voltage by more than 50%. However, the first tests of a Double-Quarter Wave (DQW) cavity with one out of three HOM filters did not reach the required voltage. The present paper describes the studies and tests conducted to understand the limiting factor in the operation of a DQW cavity with HOM filters in the most up-to-date prototypes produced in the US and based on the DQW SPS-series design. The recipe to meet the performance specification for a bare DQW cavity with HOM filters and exceed the voltage requirement by more than 35% is discussed.

43 PARTICLE ACCELERATORS↗

Test Results of the First 3.7 m Long Nb3Sn Quadrupole by LARP and Future Plans

In December 2009 during its first cold test, LQS01, the first Long Nb{sub 3}Sn Quadrupole made by LARP (LHC Accelerator Research Program, a collaboration of BNL, FNAL, LBNL and SLAC), reached its target field gradient of 200 T/m. This target was set in 2005 by the US Department of Energy, CERN and LARP, as a significant milestone toward the development of Nb{sub 3}Sn quadrupoles for possible use in LHC luminosity upgrades. LQS01 is a 90 mm aperture, 3.7 m long quadrupole using Nb{sub 3}Sn coils. The coil layout is equal to the layout used in the LARP Technological Quadrupoles (TQC and TQS models). Pre-stress and support are provided by a segmented aluminum shell pre-loaded using bladders and keys, similarly to the TQS models. After the first test the magnet was disassembled, reassembled with an optimized pre-stress, and reached 222 T/m at 4.5 K. In this paper we present the results of both tests and the next steps of the Long Quadrupole R and D.

43 PARTICLE ACCELERATORS↗

Refine your search to explore more results.