Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “intermittency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Activation and residual dose rates in the NSLS-II storage ring

It is well known that components in high energy accelerators may get activated and expose workers during maintenance activities. While the potential for activation is higher in positive ion accelerators due to the prolific production of neutrons, certain regions and components in high energy electron accelerators too can be activated enough to create residual dose rates that require careful attention for ALARA compliance. In this report, the activation and residual dose rates from a few materials are studied from various beam loss scenarios ranging from chronic point losses to intermittent real loss scenarios obtained from the operational parameters of the NSLS-II storage ring. FLUKA Monte Carlo radiation transport code is used to model the geometry, the time profile of the beam losses and score the resulting time evolution of the remnant activity and the residual dose rates.

36 MATERIALS SCIENCE↗

Instrumentation and Data Analysis Supporting the Transient Rod Pneumatic System Design Study at the Annular Core Research Reactor

The Sandia National Laboratories Annular Core Research Reactor (ACRR) has been experiencing intermittent failures of its pneumatically operated transient rod system. The most frequent failures have been to the dashpot rod where it connects to the upper aluminum connecting rod. Within the three systems, Transient Rod (TR) A has the most frequent failures. In order to conduct the pulse operations, the Transient Rods are pneumatically driven to quickly remove "poison" from the reactor core. During these pulse operations increased forces and vibrations are placed on the TR system. In an effort to fix these problems, Sandia's TA-V Nuclear Reactor and Systems Engineering Department (Engineering Department) has started an extensive Transient Rod Pneumatic System Design Study. The goal of this study is to determine the causes of the elevated failure rates in TR A. This necessitates an increased understanding of the dynamics in the TR systems. This report will cover the approach taken and reasoning behind the choices of instrumentation, calibration, data collection and data analysis used to diagnose these failures. In order to determine the types and specifications for the sensors that will be installed, estimates of the TR system performance needed to be determined. Using known and assumed parameters, mechanical and thermodynamic models were developed, and calculations performed to estimate ranges of displacement, speed, and acceleration experienced by the transient rod system. After some preliminary data collection, the thermodynamic models were refined for better accuracy. After installation of the full suite of sensors, data can be collected and analyzed in order to determine the cause of the increased failures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Study of Polysulfide Speciation in Lithium Sulfur Batteries using in situ Confocal Raman Microscopy: Introduction

A transition to sustainable energy is among society’s greatest challenges. With this change, the development of more efficient, safe, and cost-effective batteries is also necessary. Batteries are becoming ever more integral to today’s technology rich world. 3 Intermittent power sources, such as wind and solar, require storage devices to deliver a consistent energy supply. More ecofriendly, electric vehicles, have limited travel distances due to low energy density batteries. Phones and other personal electronics are also reliant on battery performance. An encouraging improvement in specific energy from current, lithium (Li) ion batteries, which are already nearing the bounds of their performance potential, are lithium sulfur (Li-S) batteries.

25 ENERGY STORAGE↗

Fluid-Structure Interactions using Controlled Disturbances on a Slender Cone in Hypersonic Flow

Fluid-structure interactions were studied on a 7° half-angle cone in the Sandia Hypersonic Wind Tunnel at Mach 8 over a range of freestream Reynolds numbers between 3.3 and 14.5 × 10 6 /m. A thin panel with tunable structural natural frequencies was integrated into the cone and exposed to naturally developing boundary layers. An elevated panel response was measured during boundarylayer transition at frequencies corresponding to the turbulent burst rate, and lower vibrations were measured under a turbulent boundary layer. Controlled perturbations from an electrical discharge were then introduced into the boundary layer at varying frequencies corresponding to the structural natural frequencies of the panel. The perturbations were not strong enough to drive a panel response exceeding that due to natural transition. Instead at high repetition rates, the perturber modified the turbulent burst rate and intermittency on the cone and therefore changed the conditions for when an elevated transitional panel vibration response occurred. Studies were also conducted in the Boeing/AFOSR Mach 6 Quiet Tunnel at Purdue University. Under quiet flow, natural transition does not occur, and the controlled perturbations are the only disturbance source. A clear panel response to turbulent spots created by the controlled perturbations was observed at varying frequencies of spot generation. The quiet-flow measurements confirm the clear relationship between turbulent spot passage and panel vibration.

42 ENGINEERING↗

Assessment of Hanford Site Reduced Boundary Impacts: Limited Potential-to-Emit and Onsite Receptor Assessments

The U.S. Department of Energy’s Hanford Site Comprehensive Land Use Plan initiated this work to prospectively determine the potential impact of a proposed reduced Hanford Site controlled access boundary to the regulatory requirements of several radiological air emission units at the Hanford Site 200 Areas. The reduced boundary would allow access to portions of the Hanford Site that are currently closed to the public. In addition, doses to several representative members of the public are presented. The assessments to determine the impact to the potential-to-emit (PTE) dose indicated in the Hanford Site FF-01 Air Operating Permit show that only one of the evaluated stacks, located in the Hanford Site 200 West Area, has the potential to increase its PTE dose. This increased PTE dose result would not change its classification from a minor emission unit to a major emission unit. Dose estimates for representative members of the public are based on average external exposure and inhalation dose estimates. Doses are presented for a Hanford Site tour participant, an intermittent hiker in the Wye Barricade region, and a hiker in a generalized portion of newly opened areas south and west of the Columbia River.

40CFR61subpartH↗

Demand Response Optimization and Management System for Real-TIme (DROMS-RT)

To design and demonstrate DROMS-RT, a highly distributed Demand Response Optimization and Management System for Real-Time (DROMS-RT) power flow control to support large scale integration of distributed renewable generation into the grid. AutoGrid developed a novel control and communications platform to allow highly dispatchable demand response (DR) services in time frames suitable for providing ancillary services to the transmission grid. These services will be substantially less expensive and more efficient than other forms of ancillary services options currently available to manage the intermittency associated with large-scale renewable integration. DROMSRT successfully leveraged Automated Demand Response (ADR) by fundamentally re-thinking the architecture of the DR platform from the ground up and by developing innovative new technologies in a number of areas related to DR. DROMS-RT leveraged the low-cost, open, interoperable DR signaling technology, OpenADR, and low-cost, internet-protocol based telemetry solutions to reduce the cost of hardware. This allowed DROMS-RT to provide dynamic price signals to millions of OpenADR clients. Statistically rigorous signal processing techniques were developed to reliably detect even small load reductions in the presence of noisy baseline profiles. Novel forecasting engines based on modern online machine learning algorithms enabled accurate individualized forecasts for customer loads in the presence of dynamic pricing signals, and a real-time decision engines enabled continuous optimization and optimal dispatch of DR resources across a large portfolio of heterogeneous loads that respond at varying time-scales. Moreover, the real-time optimization conducted by the decision engine can utilize grid physics to maximize load reduction at the transmission system in addition to the distribution sites, for more efficient grid operation. Finally, the Software-as-a-Service (SaaS) availability of the DROMS-RT platform has reduced the cost of deployment and enable participation of small commercial and residential customers in DR who otherwise would not be able to do so.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Generation as a Potential Market for Solid Oxide Fuel Cells

This report explores relevant segments of the United States’ (U.S.) distributed generation (DG) market including military applications that are potential market opportunities for SOFC systems. The growth of the identified market segments through 2025 are evaluated along with an assessment of the landscape of competing technologies such as reciprocating engines and intermittent renewable energy technologies. The cost and performance of an nTH-of-a-kind (NOAK) 1-MWe class advanced SOFC DG system are estimated assuming the fruition of the goals of the SOFC program. Historical experiences with related technology, including effects of increased production capacity on capital costs, were used to develop a potential cost evolution trajectory of the DG SOFC system, which is compared with the concurrent evolution of competitive DG technologies to evaluate market penetration and cumulative capacity necessary for DG SOFC systems to be cost competitive.

30 DIRECT ENERGY CONVERSION↗

sCO 2 Brayton System Market Analysis

Supercritical CO 2 Brayton cycle systems (sCO 2 ) offer potential benefits over traditional steam plants. The changing economics of the electricity sector favors solar photovoltaic (PV), wind, and natural gas combined cycle (NGCC). Ultimately, the ability of sCO 2 systems to compete depends on the economics and ability to offer additional benefits to the market, such as the ability for dry cooling and their compact size. Updated results show that the projected LCOE for Brayton systems in the 100 to 300 MWe size range are between ${$}$44.8 and ${$}$56.1/MWh (4.48 and 5.61 cents/kWh). This report presents screening tools for assessing the potential market size and concludes that while at these LCOE estimates sCO 2 systems can compete directly against NGCC, there are many hurdles to commercialization, including the need to demonstrate long-term operations at low-cost and ability to quickly ramp for integration with intermittent resources. Additional customer discovery is necessary to fully understand the ability of this technology to solve customer problems that other technologies cannot.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Ultra-Large-Scale Power System Control and Coordination Architecture: A Strategic Framework for Integrating Advanced Grid Functionality

Electric power grids are being stressed by integration of intermittent renewable resources and significant adoption of distributed energy resources. The complexity of the grid is growing rapidly as we attempt to support technical, business, and societal goals for which power grids were not originally designed. Today, we largely take stability of the grid for granted. Stability could significantly degrade or collapse because of new dynamics introduced to the grid, and because the emerging extreme complexity makes traditional control analysis intractable, so that grid behavior is more unpredictable than in the past. This paper describes emerging issues in grid control and provides reasons why the present path of grid control evolution is problematic and presents an ultra-large scale framework for grid control that can solve today’s problems and those expected over the next 30 years. Failure to address these issues in the short term will result in rapidly escalating system deployment and maintenance costs, potential stranded assets related to replacement of the “ad hoc” systems, along with substantial operational risks that are unacceptable under current utility and regulatory practices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SunDial – An Integrated SHINES System to Enable High-penetration Feeder-level PV

The Project Team of Fraunhofer USA, National Grid, and IPKeys developed and conducted a pilot deployment of the SunDial system, a virtual power plant platform that enables high-penetrations of solar PV to be integrated into the distribution grid. The pilot was conducted over a 15-month period from August 2018 through October 2019 on a National Grid distribution feeder in Shirley, MA. A vendor-agnostic control platform (the “Global Scheduler”) optimally shaped the net load for a virtual portfolio of non-co-located DERs based on user-defined policy objectives. The goal of the SunDial project was to simplify and reduce the risk associated with the deployment of solar in high-penetration environments by: (1) Developing an open-source, vendor-agnostic dispatch platform that can be readily adapted to optimize control of DERs over a variety of use cases; (2) Developing auto-calibrating load and solar prediction methodologies that can be readily implemented and scaled to new deployments; (3) Developing a methodology to use demand-side management with traditional electrochemical energy storage to provide “load shaping” services in high solar penetration environments; (4) Using grid-scale storage to minimize short-term intermittency association with PV production; and (5) Deploying on the National Grid distribution system to gain experience on the potential for (and limits of) integrated storage with demand-side management.

14 SOLAR ENERGY↗

A Review of Sandia Energy Storage Research Capabilities and Opportunities (2020 to 2030)

Large-scale integration of energy storage on the electric grid will be essential to enabling greater penetration of intermittent renewable energy sources, modernizing the grid for increased flexibility security, reliability, and resilience, and enabling cleaner forms of transportation. The purpose of this report is to summarize Sandia's research and capabilities in energy storage and to provide a preliminary roadmap for future efforts in this area that can address the ongoing program needs of DOE and the nation. Mission and vision statements are first presented followed by an overview of the organizational structure at Sandia that provides support and activities in energy storage. Then, a summary of Sandia's energy storage capabilities is presented by technology, including battery storage and materials, power conversion and electronics, subsurface-based energy storage, thermal/thermochemical energy storage, hydrogen storage, data analytics/systems optimization/controls, safety of energy storage systems, and testing/demonstrations/model validation. A summary of identified gaps and needs is also presented for each technology and capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Energy Delivery System Design Basis Report

Nuclear power plants operate most efficiently and economically when they are operating at some constant power output. However, with the current dynamics of the grid, including the introduction and growth of renewable energy sources such as wind and solar, nuclear generation facilities across the U.S. are finding it difficult to keep their power supply constant and provide for baseload generation capacities. As a result, most nuclear plants are finding it hard to compete with other generation fuel sources, most notably, natural gas. Finding a solution to this intermittent power supply dynamic could help U.S. nuclear power plants economically compete with other generation fuel sources such as natural gas, wind, and solar. The Thermal Energy Delivery System (TEDS) at the INL aims to investigate alternative solutions to this dilemma. The TEDS design focuses on the delivery of thermal energy to different systems throughout the Dynamic Energy Transport and Integration laboratory (DETAIL). Its strategy revolves around allowing the system to operate at full generation output while storing any surplus energy for later use and/or additional function.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enabling Staged Pressurized Oxy Combustion (SPOC): Improving Flexibility and Performance at Reduced Cost

Staged Pressurized Oxy-Combustion (SPOC) is a coal combustion power technology being developed by Washington University in St. Louis (WUSTL) that offers the potential to deliver low-carbon power at a reduced cost. Traditional oxy-combustion plants remove most of the nitrogen in air prior to combustion, thereby burning fuel in oxygen instead of air, producing a flue gas containing primarily CO 2 and water that allows relatively simple CO 2 capture at amounts > 90%. This technology relies on flue gas recycle (FGR) to reduce the peak temperature and radiation that would otherwise occur in a fuel/oxygen only flame. SPOC reduces the peak temperatures of combustion by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given furnace module. This means that the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. The SPOC process operates at an elevated gas-side pressure, reducing boiler size, enhancing heat transfer to achieve a compact boiler configuration as compared to an atmospheric-pressure boiler design, and allowing the recovery of the latent heat of the water from the flue gas at a temperature useful to the steam cycle. The resultant net efficiency of the system is up to 6 percentage points greater than traditional atmospheric-pressure oxy-combustion, representing a step-change improvement over first-generation oxy-combustion technologies. WUSTL has teamed up with the Electric Power Research Institute, Inc., American Air Liquide, Inc., Doosan Babcock Limited, and the U.S. Department of Energy to develop a practicable and workable boiler design concept associated with the application of SPOC. In particular, due to the staged nature of the heat release, the team has identified the potential for enhanced process flexibility for controlling power generation over a wider load range than is normally available to conventional coal-fired power plants. Improved flexibility is a critical need as coal power plants are being tasked with providing grid stability to balance the growth of intermittent renewables. Not only is flexible operation important, achieving efficient power generation at reduced loads will be key as the plants are likely to operate in this regime for significant periods of time as more renewables become available. At reduced loads, coal-fired steam generators typically face challenges in maintaining temperature control of the reheat steam and to a lesser extent the main steam due to the heat transfer characteristics of these circuits when flue gas quantities are lower. This results in inefficient operation, both in terms of the boiler efficiency and steam turbine heat rate. Since the SPOC process can be configured to deliver targeted heat input to each boiler circuit by adjusting the relative fuel firing rate of each stage, better temperature control can be achieved during dynamic conditions. Oxygen supply flexibility is also a key consideration for the overall flexibility of the SPOC process given the operating constraints of conventional air separation units. The boiler design concept assessment is being carried out to identify the maximum permissible compactness of the SPOC boiler heating surfaces. The assessment will determine the minimum overall height that will deliver appropriate tube operating metal temperatures at full load and achieve rated reheat steam temperatures at low operating loads, balanced against the needs of efficient coal combustion, and the resultant slagging and ash environments. The design parameters are being validated by combustion testing in the 100-kWth pressurized combustion test rig at WUSTL. Testing results and model validation that form the basis of a full-scale boiler design that will encompass both efficiency and flexibility improvements over conventional oxy-combustion processes will be presented.

20 FOSSIL-FUELED POWER PLANTS↗

Review of Intrusion Detection Methods and Tools for Distributed Energy Resources

Recent trends in the growth of distributed energy resources (DER) in the electric grid and newfound malware frameworks that target internet of things (IoT) devices is driving an urgent need for more reliable and effective methods for intrusion detection and prevention. Cybersecurity intrusion detection systems (IDSs) are responsible for detecting threats by monitoring and analyzing network data, which can originate either from networking equipment or end-devices. Creating intrusion detection systems for PV/DER networks is a challenging undertaking because of the diversity of the attack types and intermittency and variability in the data. Distinguishing malicious events from other sources of anomalies or system faults is particularly difficult. New approaches are needed that not only sense anomalies in the power system but also determine causational factors for the detected events. In this report, a range of IDS approaches were summarized along with their pros and cons. Using the review of IDS approaches and subsequent gap analysis for application to DER systems, a preliminary hybrid IDS approach to protect PV/DER communications is formed in the conclusion of this report to inform ongoing and future research regarding the cybersecurity and resilience enhancement of DER systems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Considerations for Distributed Energy Resource Integration in Puerto Rico: DOE Multi-Lab Grid Modeling Support for Puerto Rico; Analytical Support for Interconnection and IEEE Std 1547-2018 National Renewable Energy Laboratory (Task 3.0)

To ensure the sustainable long-term recovery of Puerto Rico's electric power grid from hurricanes María and Irma and to build capacity to manage future potential natural disasters in the most secure and resilient way, the U.S. Department of Energy (DOE) convened experts from multiple national laboratories to develop a comprehensive set of data, models, analytic tools, and studies, considering inputs from a wide variety of stakeholder groups, to support technically sound recommendations for Puerto Rico's energy investment decisions. A resilient electric grid is vital to Puerto Rico's security, economy, and way of life, and it will provide the foundation for essential services that people and businesses on the island rely on every day. This report shows progress for a grid modeling task under the DOE-sponsored project that is a collaboration among the National Renewable Energy Laboratory (NREL) and other national laboratories. In Phase 1 of the multilab effort to support Puerto Rico's recovery, NREL provided the utility company Puerto Rico Electric Power Authority (PREPA) recommendations for a new framework of interconnection standards to accelerate the integration of utility-scale, transmission-connected renewable electrical generation and energy storage that ensure cross-technology compatibility and enable high deployment levels without compromising grid reliably, safety, or security. This Phase 2 report focuses on the interconnection of distributed energy resources (DERs) to the electric distribution system in Puerto Rico. This report is intended to familiarize the reader with Puerto Rico's distribution infrastructure and operational practices and procedures that are relevant to DER interconnection. The report also provides considerations for streamlining the interconnection process given the expected increase in deployments resulting from Puerto Rico's renewable portfolio standard (RPS) goal of 100% renewables by 2050. Accordingly, the report identifies considerations and concerns associated with the increase in intermittent generation, strategies for DER interconnection best practices, and the potential use of the latest technological solutions identified in the latest revision of the Institute of Electrical and Electronics Engineers (IEEE) 1547-2018 interconnection standard.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tapless Voltage Regulating Transformer. Final Report

Voltage regulation is a common practice in power grid operation. The conventional voltage regulation methods have been facing ever increasing challenges as the penetration of renewable generations deepens in the grid. The intermittent nature of the renewable sources may result in sudden rise or drop of power generation, possibly breaking the generation-load balance. A lack of adequate voltage control not only affects the power quality but is detrimental to the system operation with the potential for large economic losses. Most conventional voltage regulation devices rely on mechanical tap changers to impose the regulation in a step-wise manner. Although sufficient for normal operations, the mechanical tap changers can be easily worn out in the challenging situations created by renewables. In this project, a novel technology called tapless voltage regulating transformer (TAREX) was proposed and investigated. It has the potential to excel at addressing the new voltage regulation challenges and replace the conventional regulating transformers. TAREX is based on the concept of the saturable-core reactor (SCR). The voltage of a TAREX can be smoothly and continuously regulated in a reasonable range by using a low rating power electronics based controller. It uses control of the transformer core magnetization to regulate the voltage on the windings, and thus eliminates the mechanical tap changer. This project is to prove the principle of TAREX, understand the voltage regulation mechanism, and preliminarily understand its impacts on the power systems through modeling, prototyping, and testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Rechargeable Carbon-Oxygen Battery for Efficient, Low-Cost Energy Storage

As part of the Cyclotron Road program, Noon Energy Inc investigated the feasibility of a new class of rechargeable flow battery for long-duration energy storage at the 100+ hour storage capacities needed to make intermittent solar/wind power available 24/7 year-round. Whereas conventional batteries store energy in relatively expensive metals like cobalt, lithium, and vanadium, the new battery stores energy in abundant, ultra-low-cost carbon and oxygen, storage media that cost well below $1 per kWh capacity (less than the cost of their containers). It also can operate with a high roundtrip energy efficiency of ~80% and has 10x higher energy density than conventional aqueous flow batteries, even higher than lithium ion batteries at system level. These properties make it suitable for a variety of potential stationary energy storage applications as well as for electric transportation vehicles (long-haul marine shipping and trucking), so determining the best product-market fit and market entry was a key outcome of Noon’s Cyclotron Road fellowship. Noon had demonstrated initial materials development and proof-of-principle testing before the fellowship. Overall, within the fellowship Noon carried out key initial technology development in market applications, system design, risk assessment and prototyping.

25 ENERGY STORAGE↗

Test Plan for Investigation of Hydrogen Generation in SNF Canisters

This report presents a test plan to investigate radiolytic hydrogen generation in spent nuclear fuel (SNF) canisters containing Zr-based cladding materials. The initial primary contributor to the generation of radiolytic hydrogen is estimated to be the residual physisorbed water on the ZrO 2 film, post-dry out. Over the longer term the primary hydrogen source is associated with the aluminum hydroxides and water vapor. The proposed testing to be conducted in FY22 would consist of lab-scale testing on non-radioactive surrogates of oxidized ZIRLO tubing and unalloyed zirconium using a miniature steel canister (“mini-canister") designed to allow intermittent, in-situ sampling of the canister gas during irradiation. The mini-canister approach for irradiation with in-situ monitoring system was used in a recent and on-going study [McNamara and Verst, 2020a & 2020b; Verst et al., 2021] to measure radiolytic hydrogen generation from aluminum SNF cladding surrogate materials. This proposed testing will form part of the overall materials performance evaluation of the commercial SNF-in-canister system and is part of the technical bases for their continued safe dry storage

08 HYDROGEN↗

Refine your search to explore more results.