Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

SU-E-I-39: Combining Conventional Tomographic Imaging Strategy and Interior Tomography for Low Dose Dual-Energy CT (DECT)

Purpose: Dual-energy CT (DECT) affords quantitative information of tissue density and provides a new dimension for disease diagnosis and treatment planning. The technique, however, increases the imaging dose because of the doubled scans, and thus hinders its widespread clinical applications. The purpose of this work is to develop a novel hybrid DECT image acquisition and reconstruction strategy, in which one of the energies is dealt by interior tomography while the other one is obtained using conventional tomography approach. Methods: In the proposed hybrid imaging strategy, the projection data of one of the energies (e.g., high-energy) were acquired and processed in an interior scanning model, whereas the other energy in the conventional tomographic approach. It known that, if the ROI is piecewise constant or polynomial, the interior ROI can be reconstructed with TV or HOT minimization. Here we extend the TV based interior reconstruction method into dual-energy situation. The ROI images so obtained were overlaid in the context of conventional CT of the companion energy. A material based composition in ROI was used in the proposed reconstruction framework. Results: In the simulation experiment with a diagnostic DECT geometry and energies, we were able to derive the densities of soft-tissues and bones in the ROI with high fidelity. In the experimental CBCT study, both kV and MV data were collected using the on-board kV and MV imaging system. The MV data were truncated only across the ROI. Using the interior tomography reconstruction above, we were able to obtain the ROI images as that obtained using un-truncated MV data with known tissue densities. Conclusion: The proposed DECT imaging strategy provides an effective way to extract tissue density information in the ROI and in the context of anatomical images of CT imaging, with much reduced imaging dose.

60 APPLIED LIFE SCIENCES↗

Diffraction-limited 10 microns imaging with 3 meter telescopes

An IR imaging system that achieves diffraction-limited spatial resolution (about 0.8 arcsec) at 10 microns on 3-meter ground-based telescopes. The system uses a linear array of sensitive HgCdTe photodiodes, scanned in the direction perpendicular to the array axis, to form two-dimensional images. Scans are completed rapidly enough to freeze atmospheric fluctuations. Individual detectors are small compared to the diameter of the Airy disk, and images are oversampled heavily in the scan direction. This method has a number of advantages for studying small fields with very high spatial resolution, and has been applied successfully to the problem of directly imaging faint circumstellar dust shells.

Bloemhof, E. E.↗

Phasing of a space based segmented submillimeter wavelength telescope using focal plane measurements

As part of a technology development program for realizing a space based submillimeter telescope, two different approaches to the absolute phasing of a segmented primary mirror using focal plane measurements have been implemented for feasibility. The method of optimization by simulated annealing evaluates the image quality of a point spread function after all the telescope segments have been randomly moved. It accepts each iteration which improves the image quality, as well as a random number of iterations which do not, thus keeping the Strehl in the initialization procedure from falling into local maxima. Methods for determining the annealing schedule, and the step size for random segment movements are presented and discussed. Using phase diversity and a model for the telescope imaging system, a nonlinear least squares algorithm has also been implemented which parameterizes each of the segment actuator movements. Using multiple out of focus images, the segment actuator positions are estimated using an iterative procedure. Nonlinear least squares, although computationally intensive, offers a large savings in the actuator movements over simulated annealing and pairwise phasing methods for large numbers of segments. These algorithms have been integrated into a general simulation program which models the behavior of the telescope under anticipated space conditions.

Levine, B. M.↗

The Cassini Radar Investigation

The Cassini/Huygens Mission is a nineteen-year multinational project to design, construct and execute an investigation of the Saturn system, with emphasis on its largest moon, Titan. Titan's atmosphere is nearly opaque at optical wavelengths, so a Ku-band radar imaging system was required to map its surface. In this paper we describe the radar instrument, discuss some of the challenges to its design, and review its operating modes. We briefly summarize the surprises that the radar instrument has revealed while investigating Titan.

Cassini↗

Wind Tunnel Testing of a One-Dimensional Laser Beam Scanning and Laser Sheet Approach to Shock Sensing

A 15- by 15-cm supersonic wind tunnel application of a one-dimensional laser beam scanning approach to shock sensing is presented. The measurement system design allowed easy switching between a focused beam and a laser sheet mode for comparison purposes. The scanning results were compared to images from the tunnel Schlieren imaging system. The tests revealed detectable changes in the laser beam in the presence of shocks. The results lend support to the use of the one-dimensional scanning beam approach for detecting and locating shocks in a flow, but some issues must be addressed in regards to noise and other limitations of the system.

Tokars, Roger↗

Multi phenomena melt pool sensor data fusion for enhanced process monitoring of laser powder bed fusion additive manufacturing

Finding actionable trends in laser-based metal additive manufacturing process monitoring data is challenging owing to the diversity and complexity of the underlying physical interactions. A single monitoring solution that captures a particular process phenomenon, such as a photodiode that tracks melt pool intensity, is not alone capable of evaluating process stability or detecting flaw formation with sufficient precision for routine application in industry. In this work, to improve flaw detection performance, we adopted a data fusion approach that captures multiple process phenomena. To demonstrate this, we acquired data from laser powder bed fusion (LPBF) builds of cylindrical specimens produced with different laser spot sizes, emulating defocusing due to process faults such as thermal lensing. The resulting specimens had porosity of varying types and severity, quantified by post-build non-destructive X-ray computed tomography, Archimedes density measurements, and destructive metallographic characterization. During the build, the melt pool state was monitored with two coaxial high-speed video cameras and a temperature field imaging system. Physically intuitive low-level melt pool signatures, such as melt pool temperature, shape and size, and spatter intensity were extracted from this high-dimensional, image-based sensor data. These process signatures were subsequently used as input features in relatively simple machine learning models, such as a support vector machine, which were trained to detect laser defocusing, and in addition, predict porosity type and severity. The results show that the data fusion approach significantly enhanced system performance by reducing the overall false positive rate from ~ 0.1 to ~ 0.001 without sacrificing the true positive rate (~0.90). These results were at par with a black-box, deep machine learning approach (convolutional neural network).

36 MATERIALS SCIENCE↗

Neural Learning Based Blind Source Separation for Detection of Material Defects in Pulsed Thermography Images

In this paper, we introduce a neural learning-based approach to blind source separation for detection of material flaws in pulsed thermography (PT) images. This approach can be used to detect internal defects (pores) in metallic Additively Manufactured (AM) materials. Such defects occur in high-strength alloys produced with direct laser sintering AM method for nuclear energy applications. Pulsed thermal imaging system utilizes a high intensity flash lamp to rapidly heat surface of sample, a high sensitivity infrared camera to capture data of surface temperature variations. The data cube obtained with PT (stack of surface temperature images at different times) can be analyzed with image processing algorithms to detect material defects. Compared with conventional nondestructive evaluation (NDE) methods, such as digital radiography and ultrasonic testing, the PT pulsed infrared thermal detection technique has advantages of one-sided non-contact measurements, fast processing of large sample areas captured in one image. Detection of small material defects requires finding features in thermal images, which have signal contrast levels approaching sensitivity limit of IR camera. In this study, an optimized Neural Learning based Blind Source Separation (NLBSS) algorithm, including Principal Component Analysis (PCA), and Independent Component Analysis (ICA) is demonstrated to automatically extract principal temporal and spatial features of thermography frames to enhance flaw detection. By using the NLBSS algorithm, material internal defects can be automatically detected. Furthermore, this processing approach compensates for experimental thermal imaging artifacts, such as noise and uneven heating. By merging artificial intelligence with the photothermic, the NDE system detects internal calibrated defects of various sizes and depths in AM nuclear-grade metallic alloys.

Zhang, Xin↗

Performance evaluation of the two-inch return-beam vidicon three-camera subsystem.

A very-high resolution multispectral television camera system is being developed for NASA for use on the Earth Resources Technology Satellite (ERTS) program. There are three cameras in the system, each viewing the same area but operating in the blue-green, red and near-infrared spectral bands. In the laboratory the cameras' limiting resolution is 4500 TV lines over the 25 x 25-mm image format of the Return Beam Vidicon (RBV). Analysis of typical ERTS scenes shows that actual contrast ratios will be much lower than those of laboratory test targets. A model was developed to predict the resolving power performance of the RBV camera under realistic conditions. The methods used are applicable to all types of imaging systems. To verify the model, tests were conducted using the RBV camera, a laser-beam image reproducer and a series of AF tribar test patterns of known values of contrast. As a more graphic demonstration, simulated multispectral images were generated using color-IR photographs from Apollo 9.

Miller, B. P.↗

Systems and methods for powder bed additive manufacturing anomaly detection

Detection and classification of anomalies for powder bed metal additive manufacturing. Anomalies, such as recoater blade impacts, binder deposition issues, spatter generation, and some porosities, are surface-visible at each layer of the building process. A multi-scaled parallel dynamic segmentation convolutional neural network architecture provides additive manufacturing machine and imaging system agnostic pixel-wise semantic segmentation of layer-wise powder bed image data. Learned knowledge is easily transferrable between different additive manufacturing machines. The anomaly detection can be conducted in real-time and provides accurate and generalizable results.

Scime, Luke R.↗

OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. I. INSTRUMENT DESCRIPTION AND FIRST RESULTS

First results of a new speckle imaging system, the Differential Speckle Survey Instrument, are reported. The instrument is designed to take speckle data in two filters simultaneously with two independent CCD imagers. This feature results in three advantages over other speckle cameras: (1) twice as many frames can be obtained in the same observation time which can increase the signal-to-noise ratio for astrometric measurements, (2) component colors can be derived from a single observation, and (3) the two colors give substantial leverage over atmospheric dispersion, allowing for subdiffraction-limited separations to be measured reliably. Fifty-four observations are reported from the first use of the instrument at the Wisconsin-Indiana-Yale-NOAO 3.5 m Telescope{sup 9}The WIYN Observatory is a joint facility of the University of Wisconsin-Madison, Indiana University, Yale University, and the National Optical Astronomy Observatories. in 2008 September, including seven components resolved for the first time. These observations are used to judge the basic capabilities of the instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

Eye-tracking of nodule detection in lung CT volumetric data

Purpose: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. Methods: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. Results: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25–30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. Conclusions: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.

60 APPLIED LIFE SCIENCES↗

Proton dose calculation on scatter-corrected CBCT image: Feasibility study for adaptive proton therapy

Purpose: To demonstrate the feasibility of proton dose calculation on scatter-corrected cone-beam computed tomographic (CBCT) images for the purpose of adaptive proton therapy. Methods: CBCT projection images were acquired from anthropomorphic phantoms and a prostate patient using an on-board imaging system of an Elekta infinity linear accelerator. Two previously introduced techniques were used to correct the scattered x-rays in the raw projection images: uniform scatter correction (CBCT{sub us}) and a priori CT-based scatter correction (CBCT{sub ap}). CBCT images were reconstructed using a standard FDK algorithm and GPU-based reconstruction toolkit. Soft tissue ROI-based HU shifting was used to improve HU accuracy of the uncorrected CBCT images and CBCT{sub us}, while no HU change was applied to the CBCT{sub ap}. The degree of equivalence of the corrected CBCT images with respect to the reference CT image (CT{sub ref}) was evaluated by using angular profiles of water equivalent path length (WEPL) and passively scattered proton treatment plans. The CBCT{sub ap} was further evaluated in more realistic scenarios such as rectal filling and weight loss to assess the effect of mismatched prior information on the corrected images. Results: The uncorrected CBCT and CBCT{sub us} images demonstrated substantial WEPL discrepancies (7.3 ± 5.3 mm and 11.1 ± 6.6 mm, respectively) with respect to the CT{sub ref}, while the CBCT{sub ap} images showed substantially reduced WEPL errors (2.4 ± 2.0 mm). Similarly, the CBCT{sub ap}-based treatment plans demonstrated a high pass rate (96.0% ± 2.5% in 2 mm/2% criteria) in a 3D gamma analysis. Conclusions: A priori CT-based scatter correction technique was shown to be promising for adaptive proton therapy, as it achieved equivalent proton dose distributions and water equivalent path lengths compared to those of a reference CT in a selection of anthropomorphic phantoms.

60 APPLIED LIFE SCIENCES↗

Quantum-enhanced phase imaging without coincidence counting

Quantitative phase imaging provides a way to image transparent objects, such as biological cells, and measure their thickness. We report on a phase-imaging method that achieves twice the phase shift and approximately 1.7 times the spatial resolution of an equivalent spatially and temporally coherent classical quantitative phase-imaging system by using quantum interference between successive spontaneous parametric downconversion events in a nonlinear crystal. Furthermore, our method is approximately 1000 times faster than imaging the parametric downconversion photons in coincidence, which requires measurement times on the order of tens of hours. Our method may be useful for imaging sensitive transparent objects that require low illumination intensities at near-infrared and longer illumination wavelengths, such as photosensitive biological samples.

47 OTHER INSTRUMENTATION↗

Space shuttle visual simulation system design study

The current and near-future state-of-the-art in visual simulation equipment technology is related to the requirements of the space shuttle visual system. Image source, image sensing, and displays are analyzed on a subsystem basis, and the principal conclusions are used in the formulation of a recommended baseline visual system. Perceptibility and visibility are also analyzed.

Source record↗

Direct imaging of extra-solar planetary systems with the Circumstellar Imaging Telescope (CIT)

In a joint study conducted by the Jet Propulsion Laboratory and the Perkin-Elmer Corporation it was found that an earth orbital, 1.5 meter diameter low scattered light coronagraphic telescope can achieve a broad range of scientific objectives including the direct detection of Jupiter-sized planets around the nearby stars. Recent major advances in the understanding of coronagraphic performance and in the field of super smooth mirror fabrication allow such an instrument to be designed and built within current technology. Such a project, called the Circumstellar Imaging Telescope (CIT), is currently being proposed.

Terrile, Richard J.↗

Radio science with Voyager 2 at Uranus - Results on masses and densities of the planet and five principal satellites

Phase-coherent Doppler data generated by the Deep Space Network with the radio communication system during the Voyager 2 encounter with Uranus in January 1986, optical navigation data generated by the Voyager Navigation Team with the Voyager 2 imaging system, and ground-based astrometric data obtained over an 8-yr period are compiled and analyzed to determine the masses and densities of Uranus and its principal satellites. The data-analysis procedures are explained in detail, and the results are presented in tables and graphs. The mean density of Uranus is found to be 1.285 + or - 0.001 g/cu cm, whereas the mean uncompressed mass of all five satellites is 1.48 + or - 0.06 g/cu cm, or 0.10 g/cu cm above the density expected for a homogeneous solar mix of rock, H2O and NH3 ice, and CH4 as clathrate hydrate. This difference is tentatively attributed to the presence of 15 mass percent of pure graphite, which would provide the thermal conductivity required to keep the satellites cold and undifferentiated.

Anderson, J. D.↗

Masses of the Planetary Nebula Central Stars in the Galactic Globular Cluster System from HST Imaging and Spectroscopy

The globular cluster (GC) system of our Galaxy contains four planetary nebulae (PNe): K 648 (or Ps 1) in M15, IRAS 18333-2357 in M22, JaFu 1 in Pal 6, and JaFu 2 in NGC 6441. Because single-star evolution at the low stellar mass of present-epoch GCs was considered incapable of producing visible PNe, their origin presented a puzzle. We imaged the PN JaFu 1 with the Hubble Space Telescope (HST) to obtain photometry of its central star (CS) and high-resolution morphological information. We imaged IRAS 18333-2357 with better depth and resolution, and we analyzed its archival HST spectra to constrain its CS temperature and luminosity. All PNe in Galactic GCs now have quality HST data, allowing us to improve CS mass estimates. We find reasonably consistent masses between 0.53 and 0.58 M {sub ⊙} for all four objects, though estimates vary when adopting different stellar evolutionary calculations. The CS mass of IRAS 18333-2357, though, depends strongly on its temperature, which remains elusive due to reddening uncertainties. For all four objects, we consider their CS and nebula masses, their morphologies, and other incongruities to assess the likelihood that these objects formed from binary stars. Although generally limited by uncertainties (∼0.02 M {sub ⊙}) in post-AGB tracks and core mass versus luminosity relations, the high-mass CS in K 648 indicates a binary origin. The CS of JaFu 1 exhibits compact, bright [O iii] and H α emission, like EGB 6, suggesting a binary companion or disk. Evidence is weaker for a binary origin of JaFu 2.

79 ASTRONOMY AND ASTROPHYSICS↗

Refine your search to explore more results.