Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid solutions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Electromagnetic Transient Modeling of Large Data Centers for Grid-Level Studies: Beta Release

The magnitude and complexity of electricity usage patterns from large data centers are having significant impacts on the operation and dynamics of the power grid; grid operators and planners require a range of specialized data center models to properly evaluate these impacts and specify technical solutions as needed. Towards addressing this need, Pacific Northwest National Laboratory (PNNL) has developed a library of electromagnetic transient (EMT) models for grid-level studies of data centers called the data center model library (DML). This report describes how the DML was created and how it may properly be used. This report details the DML’s beta release, completed in July 2026. This is a revision and expansion of the alpha release, which was made available in January 2026 The models present in the DML are generic models; subject matter expertise and additional technical data are needed to modify these models before they can represent any real data center. However, they will significantly reduce the level of effort required to develop site-specific models and can serve as a common starting point to guide industry towards a more refined consensus. Most of the models within DML are dedicated to representing the power electronics interfaces commonly used in modern data centers, such as double-conversion uninterruptible power supplies and single-phase power factor correction converters. These models are intended for use in grid-level studies and are a simplified aggregation of many small components. That said, background material on the physical and electrical design of large data centers is provided as companion material so that users can be aware of many of the details which have been omitted or streamlined as a matter of practical necessity. Additionally, guidance on the application of EMT analysis for data center interconnection studies is provided, which aids users in identifying when the DML is necessary and what sort of additional model development may be necessary for conducting real-world studies.

electromagnetic transients↗

Hybrid Grid-Renewable Strategies for Green Steel Production under Electricity Market Uncertainty

Volatility in grid spot prices is expected to rise with climate change-driven demand pressures and the intermittency of renewable generation. This volatility poses financial risks for green hydrogen-based steel production. The Direct Reduced Iron− Electric Arc Furnace (H 2 -DRI-EAF) is a promising pathway to decarbonize steel, which accounts for ∼8% of global GHG emissions. This study assesses how increased grid spot price volatility influences the optimal sizing and operation of H2-DRIEAF plants under three operational scenarios: grid-connected, fully behind-the-meter (islanded), and mixed-mode (semi-islanded). Our analysis identifies the semi-islanded configuration as the most cost-effective solution, achieving a Levelized Cost of Steel (LCOS) 10−35% lower than sourcing energy solely from the grid. Modeling also shows hydrogen storage or selective electricity purchases at high prices (>$1000/MWh) generally outperform battery storage, except under extreme volatility. Additionally, the study explores cost reduction strategies to strengthen the economic viability and sustainability of green steel production.

Batteries↗

Architecture for Quantum-in-the Loop Real-Time Simulations for Designing Resilient Smart Grids

With the power grid growing more complex every day with the inclusion of new sensors and regulatory approvals that enable end-users and small local developers to participate in the grid, it is becoming challenging for conventional smart grid simulation, emulation, and testing technologies to keep up. In this work, we propose that quantum-encoded real-time simulations can be helpful under the new paradigm and operational circumstances to solve optimization problems for power grids. By leveraging the principles of quantum mechanics, the proposed quantum-in-loop (QIL) framework will enable better and faster optimization solutions based on real-world, real-time data streams, facilitating the real-time planning and operations of electrical grids that rely on millions of distributed sensors and controllers. Furthermore, QIL will allow researchers and engineers to assist utilities in designing, developing, and de-risking algorithms to optimize power grid operation and resilience by considering inputs from millions of grid-connected devices. QIL framework is being developed to have a self-limiting triage mechanism, which will help engineers and practitioners identify fundamental physical limits on quantum processors, revealing what quantum algorithms can and cannot do in utility-specific use cases and must continue to count on classical high-performance computing infrastructure.

digital real-time simulation↗

Model reduction for a power grid model

We examine the complexity of constructing reduced order models for subsets of the variables needed to represent the state of the power grid. In particular, we apply model reduction techniques to the DeMarco-Zheng power grid model. We show that due to the oscillating nature of the solutions and the absence of timescale separation between resolved and unresolved variables, the construction of accurate reduced models becomes highly non-trivial because one has to account for long memory effects. In addition, we show that a reduced model that includes even a short memory is drastically better than a memoryless model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Robust Multigrid Smoothers for Three Dimensional Elliptic Equations with Strong Anisotropies

We discuss the behavior of several plane relaxation methods as multigrid smoothers for the solution of a discrete anisotropic elliptic model problem on cell-centered grids. The methods compared are plane Jacobi with damping, plane Jacobi with partial damping, plane Gauss-Seidel, plane zebra Gauss-Seidel, and line Gauss-Seidel. Based on numerical experiments and local mode analysis, we compare the smoothing factor of the different methods in the presence of strong anisotropies. A four-color Gauss-Seidel method is found to have the best numerical and architectural properties of the methods considered in the present work. Although alternating direction plane relaxation schemes are simpler and more robust than other approaches, they are not currently used in industrial and production codes because they require the solution of a two-dimensional problem for each plane in each direction. We verify the theoretical predictions of Thole and Trottenberg that an exact solution of each plane is not necessary and that a single two-dimensional multigrid cycle gives the same result as an exact solution, in much less execution time. Parallelization of the two-dimensional multigrid cycles, the kernel of the three-dimensional implicit solver, is also discussed. Alternating-plane smoothers are found to be highly efficient multigrid smoothers for anisotropic elliptic problems.

Llorente, Ignacio M.↗

Cone-grid scheme for solving hyperbolic systems of conservation laws and one application

In this work, we introduce a new numerical method, the so-called cone-grid scheme for solving hyperbolic systems of conservation laws. The formulation and the theoretical analysis for this scheme are slightly simpler than other algorithms. Simultaneously, our technique leads to a more efficacious numerical scheme. The Riemann solution is the basic ingredient for this scheme. We also give the main application of this technique, namely the global weak solutions for the one-dimensional model prescribes heat conduction in solids at low temperature, which called phonon–Bose model. This system consists of a conservation equation for the energy density and the heat flux. The scheme also satisfies positivity. The cone-grid scheme was compared with exact solution by three numerical examples, where explicit solutions are known. These numerical results verify the accuracy of the proposed scheme qualitatively and quantitatively.

97 MATHEMATICS AND COMPUTING↗

Chance-Constrained Energy Management System for Power Grids With High Proliferation of Renewables and Electric Vehicles

This paper proposes a two-stage energy management system (EMS) for power grids with massive integration of electric vehicles (EVs) and renewable energy resources. The first stage economic dispatch determines the optimal operating points of charging stations and battery swapping stations (BSS) for EVs under plug-in and battery swapping modes, respectively. The proposed stochastic model predictive control (SMPC) problem in this stage is characterized through a chance-constrained optimization formulation that can effectively capture the system and the forecast uncertainties. A distributed algorithm, the alternating direction method of multipliers (ADMM), is applied to accelerate the optimization computation through parallel computing. The second stage is aimed in coordinating the EV charging mechanisms to continuously follow the first-stage solutions, i.e., the target operating points, and meeting the EV customers' charging demands captured via the Advanced Metering Infrastructure (AMI). In this work, the proposed solution offers a holistic control strategy for large-scale centralized power grids in which the aggregated individual parameters are predictable and the system dynamics do not vary sharply within a short time-interval.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SiC-Based 5-kV Universal Modular Soft-Switching Solid-State Transformer (M-S4T) for Medium-Voltage DC Microgrids and Distribution Grids

Medium-voltage DC (MVDC) grids are attractive for electric aircraft and ship power systems, battery energy storage system (BESS), fast charging electric vehicle (EV), etc. Such EV or BESS applications need isolated bidirectional MVDC to LVDC or LVAC converters. However, the existing Si-based solutions cannot fulfill the requirements of a high-efficiency and robust converter for MVDC grids. This paper presents a 5 kV SiC-based universal modular solid-state transformer (SST). This universal current-source SST can interface either a LVAC or LVDC grid with a MVDC grid in single-stage power conversion, while the conventional dual active bridge (DAB) converter needs an additional inverter. The proposed SST module using 3.3 kV SiC MOSFETs and diodes is bidirectional and can serve as a building block in series or parallel for higher-voltage higher-power systems. The topology of each module is based on the soft-switching solid-state transformer (S4T) with reduced conduction loss, which features reduced EMI through controlled dv/dt, and high efficiency with full-range ZVS for main devices and ZCS for auxiliary devices. Operation principle of the modular S4T (M-S4T), capacitor voltage balancing control between the cascaded modules, design of components including a medium-voltage (MV) medium-frequency transformer (MFT) to realize a 50 kVA 5 kV DC to 600 V DC or 480 V AC M-S4T are presented. Importantly, the MV MFT prototype achieves very low leakage inductance (0.13%) and 15 kV insulation with coaxial cables and nanocrystalline cores. Here, the proposed universal modular SST is compared against the DAB solution and verified with DC-DC and DC-AC simulation and 4 kV experimental results. Significantly, the MV experimental results of a modular DC transformer with each module at MVDC are rarely covered in the literature and reported for the first time.

14 SOLAR ENERGY↗

Jet to freestream velocity ratio computations for a jet in a crossflow

The flowfield induced by a single, subsonic jet exhausting perpendicularly from a flat plate into a subsonic crossflow has been numerically investigated. Time-averaged solutions were obtained using the thin-layer Navier-Stokes equations and two overlapping grids. Test cases were chosen to match available experimental data where the jet Mach number was 0.78 and the freestream Mach number was varied to represent effective velocity ratios R from 4 to 12. Comparisons of the pressures induced on the flat plate are presented. The results show that the best agreement is obtained for R of 4 and 6, R of 8 is more difficult to resolve, and the R of 12 solution was not satisfactory. It is anticipated that the resolution could be improved by using either smaller time steps or finer grid spacing as R increases.

Margason, Richard J.↗

Grid evolution in time asymptotic problems

A technique for generating systems of coordinates for solving time asymptotic problems is described which provides a simple way of moving the mesh points in physical space and reduces the error in the solution relative to that obtained using a fixed mesh. First order partial differential equations are formulated for the grid point velocity in transient problems. Local flow information and boundary motion are used to determine the interior grid point motion.

Rai, M. M.↗

A moving discontinuous Galerkin finite element method with interface condition enforcement for compressible flows

A variation of moving discontinuous Galerkin finite element method with interface condition enforcement (MDG-ICE) is developed for solving the compressible Euler equations. The MDG-ICE method, originating from the work of Corrigan et al. [1], [2], [3], [4], is based on the space-time DG formulation, where both flow field and grid geometry are considered as independent variables and the conservation laws are enforced both on discrete elements and element interfaces. The element conservation laws are solved in the standard discontinuous solution space to determine conservative quantities, while the interface conservation is enforced using a variational formulation in a continuous space to determine discrete grid geometry. The resulting over-determined system of nonlinear equations arising from the MDG-ICE formulation can then be solved in a least-squares sense, leading to an unconstrained nonlinear least-squares problem that is regularized and solved by Levenberg-Marquardt method. A number of numerical experiments for both 1D unsteady and 2D steady state compressible flow problems are conducted to assess the accuracy and robustness of the MDG-ICE method. Numerical results obtained indicate that the MDG-ICE method is able to implicitly detect and track all types of discontinuities via interface conservation enforcement and satisfy the conservation law on both elements and interfaces via grid movement and grid management, demonstrating that an exponential rate of convergence for Sod and Lax-Harden shock tube problems can be achieved and highly accurate solutions without overheating to both double-rarefaction wave and Noh problems can be obtained.

97 MATHEMATICS AND COMPUTING↗

Comparisons of the Solutions for the Category 3--Problem 2: Cascade-Gust Interaction

Six different solutions were submitted for this benchmark problem. These were obtained using a variety of methods that can be conveniently categorized in two main groups, a nonlinear time-domain group and a linearized frequency-domain group. The first includes solutions submitted by (1) Hixon, (2) Nallasamy et. al, (3) Shieh et. al, and (4) Wang et. al, and the second includes solutions submitted by (5) Coupland and (6) Serrano et. al. Methods (1) and (2) use sixth order compact differencing schemes and the rest are essentially second order in space. With the exception of the solution submitted by Shieh et. al, all are individually discussed in great detail in the workshop proceedings. Comparisons of the submitted solutions with the benchmark solution are presented below. Due to differences in the level of solution detail provided to the author by the participants, the comparisons do not always include results from all submissions. It should be noted at the outset that, since the benchmark solution itself was numerically computed, the comparisons are somewhat subjective. In order to provide maximum latitude for the participants of the workshop, no restrictions were placed on the type of method that could be used to solve the problem. Neither was there were any stipulations to use a particular grid topology or grid density. Therefore, without a detailed study of the critical features of the computed solutions, it is not possible to make concrete statements about the relative merits of one method over another. Such a study is beyond the scope of the current exercise, especially since complete flowfield details were not provided to the author by all participants. Instead a package, containing the information about the benchmark solution (both the steady and unsteady parts of it), is included on the proceedings CD should the authors who submitted solutions for this problem wish to examine in detail the benchmark solution and compare their results to it.

Envia, Edmane↗

Numerical solutions for heat flow in adhesive lap joints

The present formulation for the modeling of heat transfer in thin, adhesively bonded lap joints precludes difficulties associated with large aspect ratio grids required by standard FEM formulations. This quasi-static formulation also reduces the problem dimensionality (by one), thereby minimizing computational requirements. The solutions obtained are found to be in good agreement with both analytical solutions and solutions from standard FEM programs. The approach is noted to yield a more accurate representation of heat-flux changes between layers due to a disbond.

Howell, P. A.↗

Development of a Hydrogen Energy System as a Grid Frequency Management Tool

The Hawai‘i Natural Energy Institute (HNEI) is conducting research to assess the technical potential of using an electrolyzer-based hydrogen (H2) production and storage system as a grid demand response tool using battery data from a 200 MW grid to show the kind of response required. The hydrogen produced by the electrolyzer is used for transportation. A 65 kg/day hydrogen energy system (HES) consisting of a PEM electrolyzer, 35 bar buffer tank, 450 bar compressor, and associated chiller systems was purchased and installed at the Hawaii Natural Energy Laboratory Hawaii Authority (NELHA) to demonstrate long-term durability of the electrolyzer under cyclic operation required for frequency regulation on an island grid system. The excess hydrogen was stored for use by three fuel-cell buses to be operated at Hawai‘i Volcanoes National Park (HAVO) and by the County of Hawai‘i Mass Transit Agency (MTA). This paper describes the site selection and equipment commissioning, plus a comprehensive test plan that was developed to characterize the performance and durability of the electrolyzer under dynamic load conditions. The controls were modified for the operating envelope and dynamic limits of the electrolyzer. While the data showed these modifications significantly improved the system response time, it is not fast enough to match a BESS response time for grid frequency management. The electrolyzer can only be used for slower acting changes (1 to 0.5 Hz). A potential solution is to design an electrolyzer/BESS hybrid system and develop a modeling program to find the optimum mix of battery and electrolyzer to provide the maximum grid regulation services at minimum cost.

08 HYDROGEN↗

TAS::89 0927::TAS RECOVERY - The Lean Green Energy Controller Machine

Achieving efficiency improvements and providing demand-response programs have been identified as key elements of our national energy initiative. The residential market is the largest, yet most difficult, segment to engage in efforts to meet these objectives. This project developed Energy Management System that engages the consumer and enables Smart Grid services, applications, and business processes to address this need. Our innovative solution provides smart controller providing dynamic optimization of energy consumption for the residential energy consumer. Our solution extends the technical platform to include a cloud based Internet of Things (IoT) aggregation of data sensors and actuators the go beyond energy management and extend to life style services provided through compelling mobile and console based user experiences.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrating AI Data Centers with the Power Grid

The rapid expansion of artificial intelligence (AI) has triggered an unprecedented surge in electricity demand, with US data center energy use projected to double or triple 2023 levels by 2028. This exponential growth places strain on grid infrastructure, which can hinder timely construction of desired computing capacity. To bridge this supply-demand gap, utilities and AI developers are increasingly turning to demand flexibility, a strategy that incentivizes shifting or reducing power use during peak periods of grid stress. Data centers are uniquely equipped for flexible operations due to their digital workloads, built-in redundancy, and onsite energy assets. This article outlines four primary mechanisms to enable data center flexibility: computational load flexibility (shifting tasks temporally or geographically), flexible use of core facility infrastructure adjustments, energy storage utilization, and onsite electricity generation. To encourage adoption, utilities are deploying new tariff designs, including voluntary interruptible service riders, mandated flexibility requirements, and streamlined interconnection processes for flexible loads. For the highly capitalized and rapidly growing AI industry, the primary motivators for embracing these strategies are expediting facility interconnection, satisfying emerging regulatory mandates, and mitigating community resistance. While demand flexibility cannot substitute the long-term need for new bulk power generation, it serves as an essential, immediate solution for enabling near-term deployment. By transforming data centers from grid stressors into stabilizing assets, flexible operations can ensure reliable grid integration, ease market pressures, and support a resilient power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Implicit‐Explicit Additive Runge‐Kutta Integrators for the HOMME‐NH Dynamical Core

Abstract The nonhydrostatic High‐Order Method Modeling Environment (HOMME‐NH) atmospheric dynamical core supports acoustic waves that propagate significantly faster than the advective wind speed, thus greatly limiting the time step size that can be used with standard explicit time integration methods. Resolving acoustic waves is unnecessary for accurate climate and weather prediction. This numerical stiffness is addressed herein by considering implicit‐explicit additive Runge‐Kutta (ARK IMEX) methods that can treat the acoustic waves in a stable manner without requiring implicit treatment of nonstiff modes. Various ARK IMEX methods are evaluated for their efficiency in producing accurate solutions, ability to take large time step sizes, and sensitivity to grid cell length ratio. Both the gravity wave test and baroclinic instability test from the 2012 Dynamical Core Model Intercomparison Project are used to recommend 5 of the 27 ARK IMEX methods tested for use in HOMME‐NH.

97 MATHEMATICS AND COMPUTING↗

Electronic and structural features of octa-coordinated yttrium–ammonia complexes: the first neutral solvated electron precursor with eight ligands and three outer electrons

The neutral and charged yttrium metal–ammonia complexes, [Y(NH3)8]0,±, are investigated using state-of-the-art quantum chemical calculations. The electronic structure of these complexes is described as an Y(NH3)83+ core with two, three, and four electrons orbiting in its periphery. Unlike the so far reported solvated electron precursors containing alkali, alkaline earth or first-row transition metals, yttrium complexes are the only ones which can accommodate eight ammonia ligands and up to four peripheral electrons. For the neutral species, two electrons occupy the diffuse s-type orbital (1s) and one diffuse p-type orbital (1p). For the cationic counterpart one electron is removed from the 1p orbital, while for the anion another electron is added to the 1p shell. The calculated low-lying electronic states with excitation energies up to 2.0 eV populate the 1s, 1p, and 1d outer orbitals. The first ionization energy of Y(NH3)8 is 2.74 eV and its electron affinity is 0.64 eV. The present results suggest that saturated yttrium ammonia solutions will turn into solids (liquid or expanded metals), where a grid of Y(NH3)83+ centers will be surrounded by “free” electrons.

Almeida, Nuno M. S.↗

Refine your search to explore more results.