Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “focal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

OAOWFC: Okayama Astrophysical Observatory NIR Wide-Field Camera

In order to detect and trace the early phase of near-infrared (NIR) afterglows of Gamma Ray Bursts (GRBs) quickly, we are now developing the Okayama Astrophysical Observatory Wide-Field Camera, OAOWFC. The aperture size of OAOWFC is 91 cm. The focal plane is covered by a 2Kx2K HAWAII2-RG detector with a pixel size of 18.5 {mu}mx18.5 {mu}m, resulting 0.95x0.95 deg{sup 2} field of view with an image scale of 1.6 arcsec/pixel. OAOWFC is designed to be a fully robotic instrument. This camera forms a part of Multicolor Imaging Telescopes for Survey and Monstrous Explosions (MITSuME), a multi telescope system dedicated to optical-NIR follow-up observations of GRB afterglows. Very wide field of view of OAOWFC enables us to catch GRB afterglows under less accurate localization sometimes given by the first alert. OAOWFC has an ability to detect bright GRB afterglow located at z = 10 easily, and it might be detectable at z = 18 if the conditions are met.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Throughput Operando Studies using Fourier Transform Infrared Imaging and Raman Spectroscopy

A prototype operando high throughput (OHT) reactor designed and built for catalyst screening and characterization combines Fourier transform infrared (FT-IR) imaging and Raman spectroscopy in operando conditions. Using a focal plane array (FPA) detector (HgCdTe FPA, 128×128 pixels, and 1,610 Hz frame rate) for the FT-IR imaging system, the catalyst activity and selectivity of all parallel reaction channels can be simultaneously followed. Each image dataset possesses16,384 IR spectra with a spectral range of 800 to 4000 cm-1 with an 8 cm-1 resolution. Depending on the signal-to-noise ratio, 2 to 20 seconds are needed to generate a full image of all reaction channels from a dataset. Results on reactant conversion and product selectivity are obtained from FT-IR spectral analysis. Six novel Raman probes, one for each reaction channel, were specially designed and house built at Pacific Northwest National Laboratory (PNNL), to simultaneously collect Raman spectra of the catalysts and possible reaction intermediates on the catalyst surface under operando conditions. As a model system, methanol partial oxidation reaction on silica-supported molybdenum oxide (MoO3/SiO2) catalysts has been studied under different reaction conditions to demonstrate the performance of the OHT reactor.

10 SYNTHETIC FUELS↗

An Ion Doppler Spectrometer Instrument for Ion Temperature and Flow Measurements on SSPX

A high-resolution ion Doppler spectrometer has been installed on the Sustained Spheromak Plasma Experiment to measure ion temperatures and plasma flow. The system is composed of a 1 meter focal length Czerny-Turner spectrometer with diffraction grating line density of 2400 lines/mm, which allows for first order spectra between 300 and 600 nm. A 16-channel photomultiplier tube detection assembly combined with output coupling optics provides a spectral resolution of 0.0126 nm per channel. We calculate in some detail the mapping of curved slit images onto the linear detector array elements. This is important in determining wavelength resolution and setting the optimum vertical extent of the slit. Also, because of the small wavelength window of the IDS, a miniature fiber optic survey spectrometer sensitive to a wavelength range 200 to 1100 nm and having resolution 0.2 nm, is used to obtain a time-integrated spectrum for each shot to verify specific impurity line radiation. Several measurements validate the systems operation. Doppler broadening of C III 464.72 nm line in the plasma shows time-resolved ion temperatures up to 250 eV for hydrogen discharges, which is consistent with neutral particle energy analyzer measurements. Flow measurements show a sub-Alfvenic plasma flow ranging from 5 to 45 km/s for helium discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Laser-Driven Proton and Electron Sources Using APRI 100-TW Ti:Sapphire Laser System

At the Advanced Photonics Research Institute (APRI) in Korea, we have a Ti:sapphire laser system which delivers laser pulses of 100-TW peak power and 32-fs pulse duration at the repetition rate of 10 Hz. This laser facility is being used to develop compact laser-driven proton and electron sources. Energetic protons are produced by irradiating the laser pulse on a thin foil target made of copper and polyimide via the target normal sheath acceleration. Proton beam with maximum energy of up to 4 MeV was generated from a polyimide target, and showed high energy conversion efficiency from laser to proton energy. Generation of high-energy electron beams by the laser wakefield acceleration was performed by focusing the laser pulses onto a 4 mm-long He-gas jet. Quasi-monoenergetic electron beam with peak energy of 45 MeV and maximum energy of 130 MeV was produced. The quality and characteristics of electron beams are strongly dependent on the laser-plasma interaction length which depends on focal length of the focusing optics.

43 PARTICLE ACCELERATORS↗

Site Effect and Expected Seismic Performance of Buildings in Palestine- Case Study: Nablus City

The effects of local geology on ground-motion amplification and building damage were studied in Palestine-West Bank. Nakamura's method of microtremor analysis was applied in this study. The measurements showed significantly higher amplification in the frequency range of building vulnerability in different parts of Nablus city. This finding is consistent with the distribution of the earthquake damage grades in the urban areas struck by the 11 February 2004 earthquake (ML = 5.2) with a focal depth of 17 km beneath the northeastern part of the Dead Sea Basin. Quite large differences in amplification between around 1 and 9 were computed between the eastern and western rims of the city. The downtown built in the central part of the city on soft clay, marl and valley deposits, whereas the northern and southern parts of urban areas in Nablus city lying on mountains consist of consolidated carbonates bedrock. In the central part of the city and at the rims, where the thickness of fluvial deposits and soft formations is about 15 m, amplifications between 6.74 and 8.67 for dominant natural period range of 0.8-1.1 sec were obtained. On the southern and northern mountains, which are located on limestone rocks covered with a thin layer of soil, the amplification in the same frequency range was low. Calculating the natural period of the existing common buildings (T{sub b}) in the studied area (buildings with 10-12 stories), by using the dynamic analysis method. The values of T{sub b} obtained were much closed to the site dominant natural period (Ts). The findings of this study indicate that the expected differences in damage grades for urban areas in Nablus city could be attributed to variations in the thickness and physical properties of Tertiary-Quaternary sediments, which appear to be rather heterogeneous.

58 GEOSCIENCES↗

Realistic Ground Motion Scenarios: Methodological Approach

The definition of realistic seismic input can be obtained from the computation of a wide set of time histories, corresponding to possible seismotectonic scenarios. The propagation of the waves in the bedrock from the source to the local laterally varying structure is computed with the modal summation technique, while in the laterally heterogeneous structure the finite difference method is used. The definition of shear wave velocities within the soil cover is obtained from the non-linear inversion of the dispersion curve of group velocities of Rayleigh waves, artificially or naturally generated. Information about the possible focal mechanisms of the sources can be obtained from historical seismicity, based on earthquake catalogues and inversion of isoseismal maps. In addition, morphostructural zonation and pattern recognition of seismogenic nodes is useful to identify areas prone to strong earthquakes, based on the combined analysis of topographic, tectonic, geological maps and satellite photos. We show that the quantitative knowledge of regional geological structures and the computation of realistic ground motion can be a powerful tool for a preventive definition of the seismic hazard in Italy. Then, the formulation of reliable building codes, based on the evaluation of the main potential earthquakes, will have a great impact on the effective reduction of the seismic vulnerability of Italian urban areas, validating or improving the national building code.

58 GEOSCIENCES↗

Focusing mirror for x-ray free-electron lasers

We present the design, fabrication, and evaluation of a large total-reflection mirror for focusing x-ray free-electron laser beams to nanometer dimensions. We used an elliptical focusing mirror made of silicon that was 400 mm long and had a focal length of 550 mm. Electrolytic in-process dressing grinding was used for initial-step figuring and elastic emission machining was employed for final figuring and surface smoothing. A figure accuracy with a peak-to-valley height of 2 nm was achieved across the entire area. Characterization of the focused beam was performed at BL29XUL of SPring-8. The focused beam size was 75 nm at 15 keV, which is almost equal to the theoretical size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of filament geometry on the arc efficiency of a high-intensity He{sup +} ion source

A strongly focusing high-intensity He{sup +} ion source equipped with three concave electrodes has been designed and constructed as the beam source for a high-energy He{sup 0} neutral beam probe system to diagnose fusion-produced alpha particles in thermonuclear fusion plasmas. The reduction of heat load onto the concave extraction electrodes is particularly important for a long pulse operation, as the heat load deforms the electrodes and thus the beam focal length. The effects on the arc efficiency (beam current/arc power) of the ion source due to the discharge filament structure (straight-type and L-shape-type filaments), size (filament diameters of 2 and 1.5 mm), number, and the locations have been studied. Choice of the appropriate filament structure improved the arc efficiency by 17%.

43 PARTICLE ACCELERATORS↗

Laser proton acceleration in a water spray target

Studies of interaction of a cloud of submicrometer water droplets with ultrashort (40 fs) and intense ({approx}2x10{sup 19} W/cm{sup 2}) laser pulses demonstrate an efficient acceleration of protons and oxygen ions. Due to a high ratio of the volume to the enveloping surface of a single droplet and a large number of droplets in a focal volume, efficient laser pulse absorption is enabled, which provides high electron temperatures and ion acceleration to high energies. The generation of ions with energies more than 1 MeV per nucleon is demonstrated. The observed quasi-monoenergetic feature in the proton spectrum is discussed with the thermal expansion-Coulomb explosion model and numerical simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Diagnostics for fast ignition science (invited)

The ignition concept for electron fast ignition inertial confinement fusion requires sufficient energy be transferred from an {approx}20 ps laser pulse to the compressed fuel via approximately MeV electrons. We have assembled a suite of diagnostics to characterize such transfer, simultaneously fielding absolutely calibrated extreme ultraviolet multilayer imagers at 68 and 256 eV; spherically bent crystal imagers at 4.5 and 8 keV; multi-keV crystal spectrometers; MeV x-ray bremmstrahlung, electron and proton spectrometers (along the same line of sight), and a picosecond optical probe interferometer. These diagnostics allow careful measurement of energy transport and deposition during and following the laser-plasma interactions at extremely high intensities in both planar and conical targets. Together with accurate on-shot laser focal spot and prepulse characterization, these measurements are yielding new insights into energy coupling and are providing critical data for validating numerical particle-in-cell (PIC) and hybrid PIC simulation codes in an area crucial for fast ignition and other applications. Novel aspects of these diagnostics and how they are combined to extract quantitative data on ultrahigh intensity laser-plasma interactions are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrafast imaging of transient electronic plasmas produced in conditions of femtosecond waveguide writing in dielectrics

Femtosecond laser-induced plasmas in bulk dielectrics are imaged under waveguide writing conditions, for different polarizations, pulse durations, and processing depths, and their temporal evolution is measured using ultrafast pump-probe microscopy. The irradiation beam profile is elliptically shaped yielding a disklike focal volume. We demonstrate for doped phosphate glass that increasing the pulse duration improves the spatial distribution of deposited energy by minimizing beam filamentation and prefocal depletion effects. As a consequence, energy deposition in the desired volume is greatly enhanced. Our results identify key parameters for optimizing femtosecond laser processing of dielectrics and different strategies to minimize energy loss channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relativistic laser pulse focusing and self-compression in stratified plasma-vacuum systems

Laser pulse compression in plasma-vacuum systems is investigated in the weakly relativistic regime. First, within one-dimensional hydrodynamic models, the basic features of propagation in plasmas, like width and amplitude changes, are demonstrated. The numerical findings can be interpreted, in part, a by simplified model based on the variation of action method. Since transverse effects like filamentation do play a significant role, the numerical evaluations are then generalized to two-dimensional situations. An approximate analytical criterion for the dominating transverse wave number during laser propagation in plasmas is presented. Finite plasma-vacuum systems show in addition to the filamentation instability the so-called plasma lens effect. The latter is first demonstrated for a single plasma layer. It is then discussed how (i) longitudinal and transversal self-compression in plasmas, (ii) focusing by a plasma layer, and (iii) cleaning of unstable modes compete with each other in layered plasma-vacuum systems. Depending on the available parameters, optimized plasma-vacuum systems are proposed for pulse compression. Such systems can be used as a substitute for hollow fibers which are in use to shorten a pulse. Pulse lengths of one or two cycles can be reached by optimized plasma-vacuum systems, while attaining ultrarelativistic intensities in the focal spot behind the system of layers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correction of spherical aberration for an electrostatic gridded lens

Two methods to correct spherical aberration in electrostatic gridded lenses have been studied using ray-tracing simulations. Both methods are based on modifying the electrostatic field on the radial periphery of the lens. In the simplest case, the modification is done by extending the grid support axially. In the second method, the electric field on a radial periphery of the lens is modified by applying optimum voltage on an isolated correcting electrode. It is demonstrated that, for a given focal length, the voltage on this lens can be optimized for minimum aberration, and also that these lenses reduce the emittance growth of the ion beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Role of Implanter Parameters on Implant Damage Generation: an Atomistic Simulation Study

In this article we use atomistic process simulation to study the effect of some implanter parameters on damage accumulation for two types of implanters: a batch tool with a spot ion beam and a single-wafer tool with a ribbon beam. The studied parameters are the scanning speed, the wheel rotation speed and the beam diameter for the former, and the scanning speed and the beam width for the latter. We kept constant not only the species, dose and energy, but also the average dose rate, managed by the beam current, the wafer temperature (T). In such conditions damage accumulation is expected to be constant. However we show that beam focalization has a strong impact, because it affects the instantaneous dose rate. We define the instantaneous dose rate as the dose rate seen by a point of the wafer while it passes through the beam. Its effects on damage accumulation are comparable to those of wafer T and average dose rate.

36 MATERIALS SCIENCE↗

A design for a subminiature, low energy scanning electron microscope with atomic resolution

We describe a type of scanning electron microscope that works by directly imaging the electron field-emission sites on a nanotip. Electrons are extracted from the nanotip through a nanoscale aperture, accelerated in a high electric field, and focused to a spot using a microscale Einzel lens. If the whole microscope (accelerating section and lens) and the focal length are both restricted in size to below 10 {mu}m, then computer simulations show that the effects of aberration are extremely small and it is possible to have a system with approximately unit magnification at electron energies as low as 300 eV. Thus a typical emission site of 1 nm diameter will produce an image of the same size, and an atomic emission site will give a resolution of 0.1-0.2 nm (1-2 A). Also, because the beam is not allowed to expand beyond 100 nm in diameter, the depth of field is large and the contribution to the beam spot size from chromatic aberrations is less than 0.02 nm (0.2 A) for 500 eV electrons. Since it is now entirely possible to make stable atomic sized emitters (nanopyramids), it is expected that this instrument will have atomic resolution. Furthermore the brightness of the beam is determined only by the field emission and can be up to 1x10{sup 6} times larger than in a typical (high energy) electron microscope. The advantages of this low energy, bright-beam electron microscope with atomic resolution are described and include the possibility of it being used to rapidly sequence the human genome from a single strand of DNA as well as being able to identify atomic species directly from the elastic scattering of electrons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Towards combining in-beam {gamma}-ray and conversion electron spectroscopy

The SAGE spectrometer will combine a segmented Si-detector with a Ge-detector array aiming to take the simultaneous in-beam {gamma}-ray and conversion electron spectroscopy to the next level. It will be coupled with the GREAT focal plane spectrometer and the RITU gas-filled recoil separator at the accelerator laboratory of the University of Jyvaeskylae, Finland. Its high efficiency and resolution will open the door to a new era of complete spectroscopy directed, amongst others, at the study of superheavy nuclei aiming to investigate the properties of the next spherical proton shell above Z = 82.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation of opacity models for stellar interior, inertial fusion, and high energy density plasmas

Theoretical opacities are required for calculating energy transport in plasmas. In particular, understanding stellar interiors, inertial fusion, and Z pinches depends on the opacities of mid-atomic-number elements over a wide range of temperatures. The 150-300 eV temperature range is particularly interesting. The opacity models are complex and experimental validation is crucial. For example, solar models presently disagree with helioseismology and one possible explanation is inadequate theoretical opacities. Testing these opacities requires well-characterized plasmas at temperatures high enough to produce the ion charge states that exist in the sun. Typical opacity experiments heat a sample using x rays and measure the spectrally resolved transmission with a backlight. The difficulty grows as the temperature increases because the heating x-ray source must supply more energy and the backlight must be bright enough to overwhelm the plasma self-emission. These problems can be overcome with the new generation of high energy density (HED) facilities. For example, recent experiments at Sandia's Z facility [M. K. Matzen et al., Phys. Plasmas 12, 055503 (2005)] measured the transmission of a mixed Mg and Fe plasma heated to 156{+-}6 eV. This capability will also advance opacity science for other HED plasmas. This tutorial reviews experimental methods for testing opacity models, including experiment design, transmission measurement methods, accuracy evaluation, and plasma diagnostics. The solar interior serves as a focal problem and Z facility experiments illustrate the techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast optical spectrometer for the charge exchange diagnostic on RFX-mod

A new fast visible spectrometer built for the charge exchange diagnostic system of the RFX-mod Reversed Field pinch experiment is described. The optical mounting is of the Littrow type. The spectral resolution is defined by a 3000 grooves/mm, 180x143 mm{sup 2} wide reflection grating, and a focal length of 400 mm. The collimating optics is based on a commercial high quality f/2.8 telephoto lens, so that the input fibers can be vertically stacked without space in between. The detector is a two-dimensional charge coupled device back-illuminated sensor to ensure high quantum efficiency. Thus the spectrometer combines high speed, high spectral resolution, and excellent imaging quality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Refine your search to explore more results.