Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Dynamic response of a freely rotating butterfly valve in the advanced test reactor – dynamic fluid-body interaction modeling

To regulate primary coolant flow in the Advanced Test Reactor (ATR), a butterfly valve was installed between the primary coolant pumps and the reactor core. If the mechanical connection between the valve's disk and its shaft ever fails, the disk will rotate freely. Rapid disk rotation may induce pressure surges that could damage upstream pipes. In the present work, the rotational trajectory and pressure evolution during a disk free-rotation scenario were analyzed via the dynamic fluid-body interaction (DFBI) approach in STAR-CCM+, with the movement of a solid being driven by the forces and moment/torque imposed by its surrounding fluid. Assuming a large initial opening angle, the disk accelerates slowly, but swiftly passes the closed position. As a result of the sudden valve closure, a pressure surge occurs in the upstream pipes, exceeding their maximum allowable pressure. Furthermore, the disk does not stabilize at the closed position but continually oscillates due to the unsteady nature of the coolant flow. Because of the significant and continuous water hammer effect, a fix to the butterfly valve is being implemented to prevent rapid valve closure due to failure at the valve's disk/shaft mechanical connection.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Safety monitoring system for radioisotope thermoelectric generators

System alerts personnel of hazards which may develop while they are performing tests on radioisotope thermoelectric generator (RTG). Remedial action is initiated to minimize damage. Five operating conditions are monitored: hot junction temperature, cold junction temperature, thermal shroud coolant flow, vacuum in test chamber, and alpha radiation.

Zoltan, A.↗

Relative efficiency and accuracy of two Navier-Stokes codes for simulating attached transonic flow over wings

In the present study, two codes which solve the three-dimensional Thin-Layer Navier-Stokes (TLNS) equations are used to compute the steady-state flow for two test cases representing typical finite wings at transonic conditions. Several grids of C-O topology and varying point densities are used. After a description of each code and test case, standards for determining code efficiency and accuracy are defined and applied to determine the relative performance of the two codes in predicting turbulent transonic wing flows. Comparisons of computed surface pressure distributions with experimental data are made.

Bonhaus, Daryl L.↗

Relative efficiency and accuracy of two Navier-Stokes codes for simulating attached transonic flow over wings

Two codes which solve the 3-D Thin Layer Navier-Stokes (TLNS) equations are used to compute the steady state flow for two test cases representing typical finite wings at transonic conditions. Several grids of C-O topology and varying point densities are used to determine the effects of grid refinement. After a description of each code and test case, standards for determining code efficiency and accuracy are defined and applied to determine the relative performance of the two codes in predicting turbulent transonic wing flows. Comparisons of computed surface pressure distributions with experimental data are made.

Bonhaus, Daryl L.↗

Advanced launch system Component Test Facility

Upgrading of existing test facilities required for development of liquid fuel rocket engines for advanced launch systems is discussed. The Component Test Facility (CTF) for testing generators and turbopumps assemblies of the future engine is presented with emphasis on design criteria, design, test frequency, test duration, safety, and operational issues of the cryogenic propellant and high-pressure gas systems. Attention is also given to methods of controlling propellant temperatures and flows to the test components; pressurization of propellants accomplished with high-pressure hydrogen and nitrogen gases; and use of high-pressure pumps and vaporizers, which convert liquid nitrogen and hydrogen to gases at pressures up to 15,000 psig.

Pitalo, Gerald A.↗

Laser Ignition Technology for Bi-Propellant Rocket Engine Applications

This viewgraph presentation gives an overview of laser ignition technology for bipropellant rocket engines applications. The objectives of this project include: (1) the selection test chambers and flows; (2) definition of the laser ignition setup; (3) pulse format optimization; (4) fiber optic coupled laser ignition system analysis; and (5) chamber integration issues definition. The testing concludes that rocket combustion chamber laser ignition is imminent. Support technologies (multiplexing, window durability/cleaning, and fiber optic durability) are feasible.

Thomas, Matt↗

Stage Separation Wind Tunnel Tests of a Generic Two-Stage-to-Orbit Launch Vehicle

In support of NASA s Space Launch Initiative Program, stage separation wind tunnel tests of a generic two-stage-to-orbit (TSTO) launch vehicle were conducted to determine the interference aerodynamic forces and moments and to determine the proximity flow environment. The tests were conducted in the NASA Marshall Space Flight Center s Aerodynamic Research Facility using a manual separation fixture for a Mach number range of 2.74 to 4.96 and separation distances up to 80 percent and 35 percent of the body length in the vehicle X and Z coordinates, respectively. For the TSTO bimese, winged-body vehicle configuration, both wing-to-wing and wing-to-fuselage configurations were tested. Individual-body force and moment, schlieren, and surface pressure data were acquired. The results showed that the proximity aerodynamics were dominated by complex bow shock interactions, and that he booster was statically unstable at several separation positions. As compared to the isolated body, the proximity normal force change with pitch angle was found to be nearly the same, and the proximity axial force increased, in general, by 3% for both bodies.

Bordelon, Wayne J., Jr.↗

Ares I Scale Model Acoustic Test Above Deck Water Sound Suppression Results

The Ares I Scale Model Acoustic Test (ASMAT) program test matrix was designed to determine the acoustic reduction for the Liftoff acoustics (LOA) environment with an above deck water sound suppression system. The scale model test can be used to quantify the effectiveness of the water suppression system as well as optimize the systems necessary for the LOA noise reduction. Several water flow rates were tested to determine which rate provides the greatest acoustic reductions. Preliminary results are presented.

Counter, Douglas D.↗

Application of a Channel Design Method to High-Solidity Cascades and Tests of an Impulse Cascade with 90 Degrees of Turning

A technique is developed for the application of a channel design method to the design of high-solidity cascades with prescribed velocity distributions as a function of arc length along the blade-element profile. The technique is applied to both incompressible and subsonic compressible, nonviscous, irrotational fluid motion. For compressible flow, the ratio of specific heats is assumed equal to -1.0. An impulse cascade with 90 degree turning was designed for incompressible flow and was tested at the design angle of attack over a range of downstream Mach number from 0.2 to coke flow. To achieve good efficiency, the cascade was designed for prescribed velocities and maximum blade loading according to limitations imposed by considerations of boundary-layer separation.

Stanitz, John D↗

Physical Simulation of Rocket Exhaust Aerodynamics Using Heated Ethane: Conceptual Foundations

Heated ethane (C2H6) has been proposed as an alternative to inert gases for use as a motive fluid in the experimental simulation of rocket exhaust plumes. By adjusting stagnation temperature, the isentropic exponent of ethane can be tuned to approximate those produced by common rocket propellants including hydrogen, hypergols, alcohols, and hydrocarbons. As a result, ethane can be made to follow a nozzle expansion process which is nearly identical to realistic rocket engine flow fields. Additionally, its high auto-ignition temperature and resistance to condensation enable the testing of expansion ratios much larger than conventional inertgas testing. NASA SSC has performed quasi-one-dimensional analyses using the Chemical Equilibrium with Applications (CEA) code as a preliminary means to compare flow fields produced by non-reacting ethane to those of reacting combustion products. A LO2/LH2 rocket engine operating at a chamber pressure of 5.0 MPa and a mixture ratio of 6.1 was used as an example case to demonstrate ethane’s efficacy as a simulant. Errors for key similarity parameters were compared to legacy cold-flow test methods. Additional errors induced by machining tolerances and chemical impurities were also examined. Results suggest that at a 3% geometric scale and ~500 K ethane stagnation temperature, an error of less than 2.5% throughout the flow field is realistically achievable along the dimensions of Mach number, Reynolds number, pressure ratio, and isentropic exponent. The development of an experimental test bed for validation of this configuration is currently underway.

Jones, Daniel R.↗

Design, Flow Field, and Heat Transfer Characterization of the Conjugate Aero-Thermal Test Facility at NETL

A new aerothermal test facility was constructed for the purpose of studying film cooling performance in an environment that accurately simulates conjugate heat transfer characteristics that exist in engine operation. Here, this paper details the design of the facility and the plan for conducting steady state film cooling experiments to improve the understanding of conjugate heat transfer scaling from laboratory to engine conditions. The test facility consists of two separate low channels (hot gas/coolant) and each gas path has a flow conditioning section, a convergent nozzle and a test section/channel with viewports. Numerical simulations were conducted to predict flow field characteristics supporting the design of the flow loop facility. Preliminary experiments were conducted to characterize the flow field using velocity and temperature profile measurements. In addition, infrared (IR) thermography methods were developed to measure surface temperatures on the hot side of the test plate. The IR measurement methods including calibration of the IR camera is explained in detail. It was concluded that appropriate hot gas path flow conditioning could be achieved using a strainer-like tube, a perforated plate, and a honeycomb-mesh screen system upstream of the test section. Flow field measurements from preliminary experiments showed that the boundary layer profile follows the law of the wall.

47 OTHER INSTRUMENTATION↗

Aerodynamic performance of a fully film cooled core turbine vane tested with cold air in a two-dimensional cascade

The aerodynamic performance of a fully film cooled core turbine vane was investigated experimentally in a two-dimensional cascade of 10 vanes. Three of the 10 vanes were cooled; the others were solid (uncooled) vanes. Cold air was used for both the primary and coolant flows. The cascade test covered a range of pressure ratios corresponding to ideal exit critical velocity ratios of 0.6 to 0.95 and a range of coolant flow rates to 7.5 percent of the primary flow. The coolant flow was varied by changing the coolant supply pressure. The principal measurements were cross-channel surveys of exit total pressure, static pressure, and flow angle. The results presented include exit survey data and overall performance in terms of loss, flow angle, and weight flow for the range of exit velocity ratios and coolant flows investigated. The performance of the cooled vane is compared with the performance of an uncooled vane of the same profile and also with the performance obtained with a single cooled vane in the 10-vane cascade.

Stabe, R. G.↗

Recent research on V/STOL test limits at the University of Washington aeronautical laboratory

The occurence of flow breakdown during the wind tunnel testing of a powered V/STOL aircraft was studied. Flow breakdown is the low forward speed test limit in a solid wall wind tunnel and is characterized by a vortex which forms on the floor and walls of the wind tunnel thereby failing to simulate free air conditions. The flow is caused by the interaction of the model wake and tunnel boundary layer and affects the model's aerodynamic characteristics in such fashion as to negate their reliability as correctable wind tunnel data. The low speed test limit was examined using a model that possessed a discretely concentrated powered lift system using a pair of lift jets. The system design is discussed and the tests and results which show that flow breakdown occurs at a velocity ratio of approximately 0.20 are reported.

Shindo, S.↗

Details of Side Load Test Data and Analysis for a Truncated Ideal Contour Nozzle and a Parabolic Contour Nozzle

Two cold flow subscale nozzles were tested for side load characteristics during simulated nozzle start transients. The two test article contours were a truncated ideal and a parabolic. The current paper is an extension of a 2009 AIAA JPC paper on the test results for the same two nozzle test articles. The side load moments were measured with the strain tube approach in MSFC s Nozzle Test Facility. The processing techniques implemented to convert the strain gage signals into side load moment data are explained. Nozzle wall pressure profiles for separated nozzle flow at many NPRs are presented and discussed in detail. The effect of the test cell diffuser inlet on the parabolic nozzle s wall pressure profiles for separated flow is shown. The maximum measured side load moments for the two contours are compared. The truncated ideal contour s peak side load moment was 45% of that of the parabolic contour. The calculated side load moments, via mean-plus-three-standard-deviations at each nozzle pressure ratio, reproduced the characteristics and absolute values of measured maximums for both contours. The effect of facility vibration on the measured side load moments is quantified and the effect on uncertainty is calculated. The nozzle contour designs are discussed and the impact of a minor fabrication flaw in the nozzle contours is explained.

Ruf, Joseph H.↗

Experimental Performance of a Nonlinear Control Strategy to Regulate Temperature of a High-Temperature Solar Reactor

Abstract Despite the significant potential of solar thermochemical process technology for storing solar energy as solid-state solar fuel, several challenges have made its industrial application difficult. It is important to note that solar energy has a transient nature that causes instability and reduces process efficiency. Therefore, it is crucial to implement a robust control system to regulate the process temperature and tackle the shortage of incoming solar energy during cloudy weather. In our previous works, different model-based control strategies were developed namely a proportional integral derivative controller (PID) with gain scheduling and adaptive model predictive control (MPC). These methods were tested numerically to regulate the temperature inside a high-temperature tubular solar reactor. In this work, the proposed control strategies were experimentally tested under various operation conditions. The controllers were challenged to track different setpoints (500 °C, 1000 °C, and 1450 °C) with different amounts of gas/particle flowrates. Additionally, the flow controller was tested to regulate the reactor temperature under a cloudy weather scenario. The ultimate goal was to produce 5 kg of reduced solar fuel magnesium manganese oxide (MgMn2O4) successfully, and the controllers were able to track the required process temperature and reject disturbances despite the system's strong nonlinearity. The experimental results showed a maximum error in the temperature setpoint of less than 0.5% (6 °C), and the MPC controller demonstrated superior performance in reducing the control effort and rejecting disturbances.

Energy & Fuels↗

The performance of an annular vane swirler

In connection with the desirability of optimizing the design of a gas turbine combustion chamber, there exists a need for a more complete understanding of the fluid dynamics of the flow in such chambers. In order to satisfy this need, experimental and theoretical research is being conducted with the objective to study two-dimensional axisymmetric geometries under low speed, nonreacting, turbulent, swirling flow conditions. The flow enters the test section and proceeds into a larger chamber. Inlet swirl vanes are adjustable to a variety of vane angles. The present investigation concentrates on the time-mean flow characteristics which are generated by the upstream annular swirler. The investigation makes use of a five-hole pitot probe technique. A theoretical analysis of swirl numbers associated with several idealized exit velocity profiles is included, and values of the ratio of maximum swirl velocity to maximum axial velocity at different swirl strengths are given for each case.

Lilley, D. G.↗

Mechanical energy flow models of rods and beams

It has been proposed that the flow of mechanical energy through a structural/acoustic system may be modeled in a manner similar to that of flow of thermal energy/in a heat conduction problem. If this hypothesis is true, it would result in relatively efficient numerical models of structure-borne energy in large built-up structures. Fewer parameters are required to approximate the energy solution than are required to model the characteristic wave behavior of structural vibration by using traditional displacement formulations. The energy flow hypothesis is tested in this investigation for both longitudinal vibration in rods and transverse flexural vibrations of beams. The rod is shown to behave approximately according to the thermal energy flow analogy. However, the beam solutions behave significantly differently than predicted by the thermal analogy unless locally-space-averaged energy and power are considered. Several techniques for coupling dissimilar rods and beams are also discussed. Illustrations of the solution accuracy of the methods are included.

Wohlever, J. C.↗

The phase reversal phenomenon at flow separation and reattachment

Tests were conducted on two different airfoils, one of them in a low-turbulence tunnel, to detect laminar separation and turbulent reattachment locations. A 'nonintrusive' multielement sensor consisting of a large number of closely spaced individual nickel films was vacuum deposited on a thin substrate and bonded to the airfoil model surface. Each sensor element was a part of an independent constant temperature anemometer system. Time history as well as spectral analysis of signals from surface film gauges were used to determine the surface shear flow characteristics. A major breakthrough was achieved with the discovery of phase reversal in low-frequency dynamic shear stress signals across regions of flow separation and reattachment.

Stack, J. Pete↗

Refine your search to explore more results.