Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Novel method for accurately estimating membrane transport properties and mass transfer coefficients in reverse osmosis

Here, we present a simple and robust method to simultaneously characterize the water and salt permeability (A, B) of reverse osmosis (RO) membranes and mass transfer coefficient (k) in membrane modules. The proposed methodology comprises a set of RO experiments performed at different operating pressures or stages. The measured water and salt fluxes in each stage are simultaneously fitted to the RO transport equations by performing a non-linear regression, using A, B, and k as regression parameters. We first perform a systematic accuracy analysis of the proposed method across the full operational range of RO. The assessment shows that the method accuracy is substantially higher than current methods and increases with number of experimental stages and driving forces. This assessment is used to inform the design of an experimental protocol that minimizes errors in estimated A, B, and k. We then evaluate two commercial RO membranes following the new protocol. For both membranes, A and B parameters decrease by 17% and 15% from the dilute solution to seawater concentrations, whereas the k parameter remains constant. Our study demonstrates that the proposed method, informed by data-driven experimental designs, provides a new approach for accurately characterizing transport phenomenon in membrane processes with feeds of less than 100 g/L total dissolved solids.

36 MATERIALS SCIENCE↗

Accuracy of Some Approximate Gaussian Filters for the Navier--Stokes Equation in the Presence of Model Error

Bayesian state estimation of a dynamical system from a stream of noisy measurements is important in many geophysical and engineering applications where high dimensionality of the state space, sparse observations, and model error pose key challenges. In this work, three computationally feasible, approximate Gaussian data assimilation/filtering algorithms are considered in various regimes of turbulent 2D Navier--Stokes dynamics in the presence of model error. The first source of error arises from the necessary use of reduced models for the forward dynamics of the filters, while a particular type of representation error arises from the finite resolution of observations which mix up information about resolved and unresolved dynamics. Two stochastically parameterized filtering algorithms, referred to as cSPEKF and GCF, are compared with 3DVAR---a prototypical time-sequential algorithm known to be accurate for filtering dissipative systems for a suitably inflated “background” covariance. We provide the first evidence that the stochastically parameterized algorithms, which do not rely on detailed knowledge of the underlying dynamics and do not require covariance inflation, can compete with or outperform an optimally tuned 3DVAR algorithm, and they can overcome competing sources of error in a range of dynamical scenarios.

97 MATHEMATICS AND COMPUTING↗

A deep proper motion catalog within the Sloan digital sky survey footprint

A new proper motion catalog is presented, combining the Sloan Digital Sky Survey (SDSS) with second epoch observations in the r band within a portion of the SDSS imaging footprint. The new observations were obtained with the 90prime camera on the Steward Observatory Bok 90 inch telescope, and the Array Camera on the U.S. Naval Observatory, Flagstaff Station, 1.3 m telescope. The catalog covers 1098 square degrees to r = 22.0, an additional 1521 square degrees to r = 20.9, plus a further 488 square degrees of lesser quality data. Statistical errors in the proper motions range from 5 mas year{sup −1} at the bright end to 15 mas year{sup −1} at the faint end, for a typical epoch difference of six years. Systematic errors are estimated to be roughly 1 mas year{sup −1} for the Array Camera data, and as much as 2–4 mas year{sup −1} for the 90prime data (though typically less). The catalog also includes a second epoch of r band photometry.

79 ASTRONOMY AND ASTROPHYSICS↗

Retrieval of Aerosol Optical Depth in Vicinity of Broken Clouds from Reflectance Ratios: Sensitivity Study

We conducted a sensitivity study to better understand the potential of a new method for retrieving aerosol optical depth (AOD) under partly cloudy conditions. This method exploits reflectance ratios in the visible spectral range and provides an effective way to avoid three-dimensional (3D) cloud effects. The sensitivity study is performed for different observational conditions and random errors in input data. The results of the sensitivity study suggest that this ratio method has the ability to detect clear pixels even in close proximity to clouds. Such detection does not require a statistical analysis of the two-dimensional (2D) horizontal distribution of reflected solar radiation, and thus it could be customized for operational retrievals. In comparison with previously suggested approaches, the ratio method has the capability to increase the "harvest" of clear pixels. Similar to the traditional Independent Pixel Approximation (IPA), the ratio method has a low computational cost for retrieving AOD. In contrast to the IPA method, the ratio method provides much more accurate estimations of the AOD values under broken cloud conditions: pixel-based and domain-averaged estimations of errors in AOD are about 25% and 10%, respectively. Finally, both the ratio-based cloud screening and the accuracy of domain-averaged ratio-based AOD values do not suffer greatly when 5% random errors are introduced in the reflectances.

54 ENVIRONMENTAL SCIENCES↗

Extraction of diffuse correlation spectroscopy flow index by integration of Nth-order linear model with Monte Carlo simulation

Conventional semi-infinite solution for extracting blood flow index (BFI) from diffuse correlation spectroscopy (DCS) measurements may cause errors in estimation of BFI (αD{sub B}) in tissues with small volume and large curvature. We proposed an algorithm integrating Nth-order linear model of autocorrelation function with the Monte Carlo simulation of photon migrations in tissue for the extraction of αD{sub B}. The volume and geometry of the measured tissue were incorporated in the Monte Carlo simulation, which overcome the semi-infinite restrictions. The algorithm was tested using computer simulations on four tissue models with varied volumes/geometries and applied on an in vivo stroke model of mouse. Computer simulations shows that the high-order (N ≥ 5) linear algorithm was more accurate in extracting αD{sub B} (errors < ±2%) from the noise-free DCS data than the semi-infinite solution (errors: −5.3% to −18.0%) for different tissue models. Although adding random noises to DCS data resulted in αD{sub B} variations, the mean values of errors in extracting αD{sub B} were similar to those reconstructed from the noise-free DCS data. In addition, the errors in extracting the relative changes of αD{sub B} using both linear algorithm and semi-infinite solution were fairly small (errors < ±2.0%) and did not rely on the tissue volume/geometry. The experimental results from the in vivo stroke mice agreed with those in simulations, demonstrating the robustness of the linear algorithm. DCS with the high-order linear algorithm shows the potential for the inter-subject comparison and longitudinal monitoring of absolute BFI in a variety of tissues/organs with different volumes/geometries.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

How we compute N matters to estimates of mixing in stratified flows

We know that most commonly used models for turbulent mixing in the ocean rely on a background stratification against which turbulence must work to stir the fluid. While this background stratification is typically well defined in idealized numerical models, it is more difficult to capture in observations. Here, a potential discrepancy in ocean mixing estimates due to the chosen calculation of the background stratification is explored using direct numerical simulation data of breaking internal waves on slopes. There are two different methods for computing the buoyancy frequency $N$ , one based on a three-dimensionally sorted density field (often used in numerical models) and the other based on locally sorted vertical density profiles (often used in the field), are used to quantify the effect of $N$ on turbulence quantities. It is shown that how $N$ is calculated changes not only the flux Richardson number $R_{f}$ , which is often used to parameterize turbulent mixing, but also the turbulence activity number or the Gibson number $Gi$ , leading to potential errors in estimates of the mixing efficiency using $Gi$ -based parameterizations.

42 ENGINEERING↗

Improving estimates of streamflow characteristics using LANDSAT-1 (ERTS-1) imagery

The author has identified the following significant results. Streamflow characteristics in the Delmarva Peninsula derived from the records of daily discharge of 20 gaged basins are representative of the full range in flow conditions and include all of those commonly used for design or planning purposes. They include annual flood peaks with recurrence intervals of 2, 5, 10, 25, and 50 years, mean annual discharge, standard deviation of the mean annual discharge, mean monthly discharges, standard deviation of the mean monthly discharges, low-flow characteristics, flood volume characteristics, and the discharge equalled or exceeded 50 percent of the time. Streamflow and basin characteristics were related by a technique of multiple regression using a digital computer. A control group of equations was computed using basin characteristics derived from maps and climatological records. An experimental group of equations was computed using basin characteristics derived from LANDSAT imagery as well as from maps and climatological records. Based on a reduction in standard error of estimate equal to or greater than 10 percent, the equations for 12 stream flow characteristics were substantially improved by adding to the analyses basin characteristics derived from LANDSAT imagery.

Hollyday, E. F.↗

Satellite thermal modeling using the illuminographic camera

The application is discussed of illuminographic camera techniques to the measurement of radiative form factors for satellite modeling applications. The equation for the illuminographic mirror is derived, and the advantages of the method are discussed. Proximity error for the illuminographic mirror is defined, and estimates of this error as a function of the scale factor of the model are given, together with a method for halving this error. Designs for illuminographic mirrors are presented: the first provides a further threefold reduction in proximity error; the second permits the estimation of thermal radiation transfer coefficients to interior regions of otherwise inaccessible volumes. Finally, reflex Polaroid camera techniques appropriate to the relatively small size of the illuminographic mirror are described.

Wiesner, S. J.↗

Space Shuttle Debris Impact Tool Assessment Using the Modern Design of Experiments

Complex computer codes are used to estimate thermal and structural reentry loads on the Shuttle Orbiter induced by ice and foam debris impact during ascent. Such debris can create cavities in the Shuttle Thermal Protection System. The sizes and shapes of these cavities are approximated to accommodate a code limitation that requires simple "shoebox" geometries to describe the cavities -- rectangular areas and planar walls that are at constant angles with respect to vertical. These approximations induce uncertainty in the code results. The Modern Design of Experiments (MDOE) has recently been applied to develop a series of resource-minimal computational experiments designed to generate low-order polynomial graduating functions to approximate the more complex underlying codes. These polynomial functions were then used to propagate cavity geometry errors to estimate the uncertainty they induce in the reentry load calculations performed by the underlying code. This paper describes a methodological study focused on evaluating the application of MDOE to future operational codes in a rapid and low-cost way to assess the effects of cavity geometry uncertainty.

DeLoach, Richard↗

Atacama Cosmology Telescope: DR6 gravitational lensing and SDSS BOSS cross-correlation measurement and constraints on gravity with the 𝐸 𝐺 statistic

We derive new constraints on the 𝐸 𝐺 statistic as a test of gravity, combining the cosmic microwave background (CMB) lensing map estimated from Data Release 6 (DR6) of the Atacama Cosmology Telescope with Sloan Digital Sky Survey III Baryon Oscillation Spectroscopic Survey (SDSS BOSS) CMASS and LOWZ galaxy data. We develop an analysis pipeline to measure the cross-correlation between CMB lensing maps and galaxy data, following a blinding policy and testing the approach through null and consistency checks. By testing the equivalence of the spatial and temporal gravitational potentials, the 𝐸 𝐺 statistic can distinguish Λ⁢ CDM from alternative models of gravity. We find 𝐸 𝐺 ⁡(𝑧 eff = 0.555) = 0.3⁢1$^{+0.06}_{−0.05}$ for Atacama Cosmology Telescope (ACT) and CMASS data at 68.28% confidence level, and 𝐸 𝐺 ⁡(𝑧 eff = 0.316) = 0.4⁢9$^{+0.14}_{−0.11}$ for the ACT and LOWZ. Systematic errors are estimated to be 3% and 4%, respectively. Including CMB lensing information from Planck PR4 results in 𝐸 𝐺 ⁡(𝑧 eff = 0.555) = 0.3⁢4$^{+0.05}_{−0.05}$ with CMASS and 𝐸 𝐺 ⁡(𝑧 eff = 0.316) = 0.4⁢3$^{+0.11}_{−0.09}$ with LOWZ. These are consistent with predictions for the Λ⁢ CDM model that best fits the Planck CMB anisotropy and SDSS BOSS baryon acoustic oscillations (BAO), where 𝐸$^{GR}_{𝐺⁡}$(𝑧 eff =0.555) =0.401 ± 0.005 for CMB lensing combined with CMASS and 𝐸$^{GR}_{𝐺}$⁡(𝑧 eff = 0.316) = 0.452 ± 0.005 combined with LOWZ. We also find 𝐸 𝐺 to be scale independent, with probability to exceed >5%, as predicted by general relativity. The methods developed in this work are also applicable to improved future analyses with upcoming spectroscopic galaxy samples and CMB lensing measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

A new model for estimating total body water from bioelectrical resistance

Estimation of total body water (T) from bioelectrical resistance (R) is commonly done by stepwise regression models with height squared over R, H(exp 2)/R, age, sex, and weight (W). Polynomials of H(exp 2)/R have not been included in these models. We examined the validity of a model with third order polynomials and W. Methods: T was measured with oxygen-18 labled water in 27 subjects. R at 50 kHz was obtained from electrodes placed on the hand and foot while subjects were in the supine position. A stepwise regression equation was developed with 13 subjects (age 31.5 plus or minus 6.2 years, T 38.2 plus or minus 6.6 L, W 65.2 plus or minus 12.0 kg). Correlations, standard error of estimates and mean differences were computed between T and estimated T's from the new (N) model and other models. Evaluations were completed with the remaining 14 subjects (age 32.4 plus or minus 6.3 years, T 40.3 plus or minus 8 L, W 70.2 plus or minus 12.3 kg) and two of its subgroups (high and low) Results: A regression equation was developed from the model. The only significant mean difference was between T and one of the earlier models. Conclusion: Third order polynomials in regression models may increase the accuracy of estimating total body water. Evaluating the model with a larger population is needed.

Siconolfi, S. F.↗

TU-F-18C-01: Breast Tissue Decomposition Using Spectral CT After Distortion Correction

Purpose: To investigate the feasibility of accurate breast tissue compositional characterization by using spectral-distortion-corrected dual energy images from a photon-counting spectral CT. Methods: Thirty eight postmortem breasts were imaged with a Cadmium-Zinc-Telluride (CZT)-based photon-counting spectral CT system at beam energy of 100 kVp. The energy-resolved detector sorted photons into low and high energy bins with a splitting energy of 42 keV. The estimated mean glandular dose (MGD) for each breast was approximately 2.0 mGy. Dual energy technique was used to decompose breast tissue into water, lipid, and protein contents. Two image-based methods were investigated to improve the accuracy of tissue compositional characterization. The first method simply limited the recorded spectra up to 90 keV. This reduced the pulse pile-up artifacts but it has some dose penalty. The second method corrected the spectral information of all measured photons by using a spectral distortion correction technique. Breasts were then chemically decomposed into their respective water, lipid, and protein contents, which was used as the reference standard. The accuracy of the tissue compositional measurement with spectral CT was evaluated by the root-mean-square (RMS) errors in percentage composition. Results: The errors in quantitative material decomposition were significantly reduced after the appropriate image processing methods. As compared to the chemical analysis as the reference standard, the averages of the RMS errors were estimated to be 15.5%, 3.3%, and 2.8% for the raw, energy-limited, and spectral-corrected images, respectively. Conclusion: Spectral CT can be used to accurately quantify the water, lipid, and protein contents in breast tissues by implementing a spectral distortion correction algorithm. The tissue compositional information can potentially improve the sensitivity and specificity for breast cancer diagnosis.

60 APPLIED LIFE SCIENCES↗

QCD equation of state to O ( μ B 6 ) from lattice QCD

We calculated the QCD equation of state using Taylor expansions that include contributions from up to sixth order in the baryon, strangeness and electric charge chemical potentials. Calculations have been performed with the Highly Improved Staggered Quark action in the temperature range T ϵ [135 MeV , 330 MeV] using up to four different sets of lattice cutoffs corresponding to lattices of size N$3\atop{σ}$ × N τ with aspect ratio N σ /N τ = 4 and N τ = 6-16 . The strange quark mass is tuned to its physical value, and we use two strange to light quark mass ratios m s /m l = 20 and 27, which in the continuum limit correspond to a pion mass of about 160 and 140 MeV, respectively. Sixth-order results for Taylor expansion coefficients are used to estimate truncation errors of the fourth-order expansion. We show that truncation errors are small for baryon chemical potentials less then twice the temperature (μ B ≤ 2T). The fourth-order equation of state thus is suitable for the modeling of dense matter created in heavy ion collisions with center-of-mass energies down to √sNN ~ 12 GeV . We provide a parametrization of basic thermodynamic quantities that can be readily used in hydrodynamic simulation codes. The results on up to sixth-order expansion coefficients of bulk thermodynamics are used for the calculation of lines of constant pressure, energy and entropy densities in the T - μ B plane and are compared with the crossover line for the QCD chiral transition as well as with experimental results on freeze-out parameters in heavy ion collisions. These coefficients also provide estimates for the location of a possible critical point. We argue that results on sixth-order expansion coefficients disfavor the existence of a critical point in the QCD phase diagram for μ B /T≤2 and T/T c (μ B = 0) > 0.9 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NSLS-II: Nonlinear Model Calibration for Synchrotrons

This tech note is essentially a summary of a lecture we delivered to the Acc. Phys. Journal Club Apr, 2010. However, since the estimated accuracy of these methods has been naive and misleading in the field of particle accelerators, i.e., ignores the impact of noise, we will elaborate on this in some detail. A prerequisite for a calibration of the nonlinear Hamiltonian is that the quadratic part has been understood, i.e., that the linear optics for the real accelerator has been calibrated. For synchrotron light source operations, this problem has been solved by the interactive LOCO technique/tool (Linear Optics from Closed Orbits). Before that, in the context of hadron accelerators, it has been done by signal processing of turn-by-turn BPM data. We have outlined how to make a basic calibration of the nonlinear model for synchrotrons. In particular, we have shown how this was done for LEAR, CERN (antiprotons) in the mid-80s. Specifically, our accuracy for frequency estimation was {approx} 1 x 10{sup -5} for 1024 turns (to calibrate the linear optics) and {approx} 1 x 10{sup -4} for 256 turns for tune footprint and betatron spectrum. For a comparison, the estimated tune footprint for stable beam for NSLS-II is {approx}0.1. Since the transverse damping time is {approx}20 msec, i.e., {approx}4,000 turns. There is no fundamental difference for: antiprotons, protons, and electrons in this case. Because the estimated accuracy for these methods in the field of particle accelerators has been naive, i.e., ignoring the impact of noise, we have also derived explicit formula, from first principles, for a quantitative statement. For e.g. N = 256 and 5% noise we obtain {delta}{nu} {approx} 1 x 10{sup -5}. A comparison with the state-of-the-arts in e.g. telecomm and electrical engineering since the 60s is quite revealing. For example, Kalman filter (1960), crucial for the: Ranger, Mariner, and Apollo (including the Lunar Module) missions during the 60s. Or Claude Shannon et al since the 40s for that matter. Conclusion: what's elementary in the latter is considered 'advanced', if at all, in the former. It is little surprise then that published measurements typically contains neither error bars (for the random errors) nor estimates for the systematic in the former discipline. We have also showed how to estimate the state space by turn-by-turn data from two adjacent BPMs. And how to improve the resolution of the nonlinear resonance spectrum by Fourier analyzing the linear action variables instead of the betatron motion. In fact, the state estimator could be further improved by adding a Kalman filter. For transparency, we have also summarized on how these techniques provide a framework- and method for a TQM (Total Quality Management) approach for the main ring. Of course, to make the ($2.5M) turn-by-turn data acquisition system that is being implemented (for all the BPMs) useful, a means ({approx}10% contingency for the BPM system) to drive the beam is obviously required.

43 PARTICLE ACCELERATORS↗

Augmented Kalman filter with a reduced mechanical model to estimate tower loads on a land-based wind turbine: a step towards digital-twin simulations

This article presents an application of the Kalman filtering technique to estimate loads on a wind turbine. The approach combines a mechanical model and a set of measurements to estimate signals that are not available in the measurements, such as wind speed, thrust, tower position, and tower loads. The model is severalfold faster than real time and is intended to be run online, for instance, to evaluate real-time fatigue life consumption of a field turbine using a digital twin, perform condition monitoring, or assess loads for dedicated control strategies. The mechanical model is built using a Rayleigh–Ritz approach and a set of joint coordinates. We present a general method and illustrate it using a 2-degrees-of-freedom (DOF) model of a wind turbine and using rotor speed, generator torque, pitch, and tower-top acceleration as measurement signals. The different components of the model are tested individually. The overall method is evaluated by computing the errors in estimated tower-bottom-equivalent moment from a set of simulations. From this preliminary study, it appears that the tower-bottom-equivalent moment is obtained with about 10 % accuracy. The limitation of the model and the required steps forward are discussed.

17 WIND ENERGY↗

Magnetic resonance imaging-targeted, 3D transrectal ultrasound-guided fusion biopsy for prostate cancer: Quantifying the impact of needle delivery error on diagnosis

Purpose: Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided “fusion” prostate biopsy intends to reduce the ∼23% false negative rate of clinical two-dimensional TRUS-guided sextant biopsy. Although it has been reported to double the positive yield, MRI-targeted biopsies continue to yield false negatives. Therefore, the authors propose to investigate how biopsy system needle delivery error affects the probability of sampling each tumor, by accounting for uncertainties due to guidance system error, image registration error, and irregular tumor shapes. Methods: T2-weighted, dynamic contrast-enhanced T1-weighted, and diffusion-weighted prostate MRI and 3D TRUS images were obtained from 49 patients. A radiologist and radiology resident contoured 81 suspicious regions, yielding 3D tumor surfaces that were registered to the 3D TRUS images using an iterative closest point prostate surface-based method to yield 3D binary images of the suspicious regions in the TRUS context. The probabilityP of obtaining a sample of tumor tissue in one biopsy core was calculated by integrating a 3D Gaussian distribution over each suspicious region domain. Next, the authors performed an exhaustive search to determine the maximum root mean squared error (RMSE, in mm) of a biopsy system that gives P ≥ 95% for each tumor sample, and then repeated this procedure for equal-volume spheres corresponding to each tumor sample. Finally, the authors investigated the effect of probe-axis-direction error on measured tumor burden by studying the relationship between the error and estimated percentage of core involvement. Results: Given a 3.5 mm RMSE for contemporary fusion biopsy systems,P ≥ 95% for 21 out of 81 tumors. The authors determined that for a biopsy system with 3.5 mm RMSE, one cannot expect to sample tumors of approximately 1 cm{sup 3} or smaller with 95% probability with only one biopsy core. The predicted maximum RMSE giving P ≥ 95% for each tumor was consistently greater when using spherical tumor shapes as opposed to no shape assumption. However, an assumption of spherical tumor shape for RMSE = 3.5 mm led to a mean overestimation of tumor sampling probabilities of 3%, implying that assuming spherical tumor shape may be reasonable for many prostate tumors. The authors also determined that a biopsy system would need to have a RMS needle delivery error of no more than 1.6 mm in order to sample 95% of tumors with one core. The authors’ experiments also indicated that the effect of axial-direction error on the measured tumor burden was mitigated by the 18 mm core length at 3.5 mm RMSE. Conclusions: For biopsy systems with RMSE ≥ 3.5 mm, more than one biopsy core must be taken from the majority of tumors to achieveP ≥ 95%. These observations support the authors’ perspective that some tumors of clinically significant sizes may require more than one biopsy attempt in order to be sampled during the first biopsy session. This motivates the authors’ ongoing development of an approach to optimize biopsy plans with the aim of achieving a desired probability of obtaining a sample from each tumor, while minimizing the number of biopsies. Optimized planning of within-tumor targets for MRI-3D TRUS fusion biopsy could support earlier diagnosis of prostate cancer while it remains localized to the gland and curable.

60 APPLIED LIFE SCIENCES↗

Assessing the Performance of Exchange‐Correlation Density Functionals in Describing the Iron‐Catalyzed Ammonia Synthesis System

Density functional theory (DFT) has been widely employed for elucidating mechanistic aspects of heterogeneous catalysis. However, the accuracy of DFT calculations relies heavily on selecting an exchange-correlation (XC) functional that correctly describes the electronic structure of materials involved in the reactions. This study assesses the accuracy of several XC density functionals for modeling the iron-catalyzed ammonia synthesis system. In the assessment of functional accuracy, experimental references are compared to DFT-calculated values for the formation energy of gas-phase ammonia and nitrogen, bulk Fe/Fe-nitride (γ′-Fe 4 N) lattice constants and cohesive/formation energies, and nitrogen and ammonia binding energies on Fe(100), Fe(111), Fe(110), and γ′-Fe 4 N(111). It is observed that the experimental value for each of these descriptors is accurately modeled by at least one functional. RPBE alone provides reliable estimates for both the lattice constant and cohesive energy of Fe and γ′-Fe 4 N. Temperature-programmed desorption experiments led to estimates for N and NH 3 adsorption across several Fe-based facets that are best captured by RPBE. These results highlight the importance of choosing an appropriate XC functional that accurately describes experimental systems and offer insights into effectively modeling the interactions between nitrogen and ammonia on Fe-based surfaces.

adsorption↗

On the Representativity of Electrode Microstructure Parameters and Their Electrochemical Response for Lithium Ion Batteries

Lithium-ion battery electrochemical models require an accurate description of the electrodes microstructures to be predictive that can be achieved through nanoscale imaging. Such observations are however limited by their field of view (FOV), as they provide only a subset of the whole electrode volume that does not necessarily represent the whole electrode microstructure heterogeneity, and therefore can bias the microstructure analysis. A microstructure scale electrochemical model was used to investigate lithium plating onset, material non-uniform utilization, and in-plane heterogeneities for an NMC-graphite full cell. To evaluate the representativeness, and thus relevance, of these model predictions, a coupled representativity analysis has been performed on the microstructure parameters and, in a novel way, on the full cell electrochemical response. Electrode microstructure parameters representativeness has been first quantified using the representative volume element (RVE) methodology. The RVE major flaw is that ultimately it can only conclude if a FOV contains representative subvolumes of the FOV, but not if the FOV itself is representative of the electrode volume. Analysis can conclude negatively ('FOV is not representative'), but not positively ('FOV is representative'). One major contribution of this work was to quantify the convergence of the RVE size with the FOV, to actually investigate the FOV representativeness and thus partly remedy this intrinsic limitation. The analysis determined that performing a standard RVE calculation, without exploring its FOV convergence, is likely to strongly underestimate the actual RVE size. The new RVE methodology has been automated in the NREL open-source Microstructure Analysis Toolbox (MATBOX) and is available to the battery community. Representativeness of microstructure parameters is however only an intermediate step, as the end-results of an electrochemical model are performances predictions. Indeed, what is the practical consequence of a given deviation for a microstructure parameter? The microstructure parameter deviation propagations to the 3D microstructure scale electrochemical response have been then quantified for different charge rates. This defines a threshold for the microstructure parameters FOV for a desired maximum deviation of the electrochemical response. Such deviation propagation analysis is analogous to error propagation analysis and is necessary to determine the relevance of microstructure scale model predictions for macroscale predictions. Electrochemical model shows cell representative section areas are increasing with C-rate, due to higher in-plane heterogeneities, indicating larger FOVs are required specifically for fast charge modeling. Therefore, we introduced the novel concept of electrochemical RVE (eRVE) that is a function of the operating conditions (thus defined as a dynamic RVE), with an increasing dependence with the C-rate. Representativity analysis of the investigated cell determined a FOV of 144.4 x 54.4 m2 is large enough to establish a convergence on the representative section areas for low to intermediate C-rate (=2.5C), but not large enough to conclude for higher rates. This work aims to emphasize the importance of representativity analysis for LIB electrode microstructures, as it is required to estimate the error, and thus the relevance, of microstructure parameters intended to be used in macroscale models. The methodology and results can help researchers to select the relevant imaging and associated FOV required to provide accurate enough microstructure parameters.

ADVANCED PROPULSION SYSTEMS↗

Refine your search to explore more results.