Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,801 records · Page 100

Refined Telluric Absorption Correction for Low-resolution Ground-based Spectroscopy: Resolution and Radial Velocity Effects in the O{sub 2}A-band for Exoplanets and K i Emission Lines

Telluric correction of spectroscopic observations is either performed via standard stars that are observed close in time and airmass along with the science target, or recently growing in importance, by theoretical telluric absorption modeling. Both approaches work fine when the telluric lines are resolved, i.e., at a spectral resolving power larger than about 10,000, and it is sufficient to facilitate the detection of spectral features at lower resolution. However, a meaningful quantitative analysis also requires the reliable recovery of line strengths. Here, we show for the Fraunhofer A-band of molecular O{sub 2} that the standard telluric correction approach fails in this at lower spectral resolutions, as an example for the general problem. Doppler-shift-dependent errors of the restored flux may arise, which can amount to more than 50% in extreme cases, depending on the line shapes of the target spectral features. Two applications are discussed: the recovery of the O{sub 2} band in the reflected light of an Earth analog atmosphere, as facilitated potentially in the future using an orbiting starshade and a ground-based extremely large telescope; and the recovery of the intrinsic ratio of the K i lines in the post-nova V4332 Sgr tracing the optical depth of the emitting region, to exemplify the relevance using present-day instrumentation. We show how one should derive correction functions for the compensation of the error in dependence of radial velocity shift, spectral resolution, and target line-profile function by use of high-resolution atmospheric transmission modeling, which has to be solved for the individual case.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: An improved calibration system with phase correction for electronic transformers with digital output

The existing electronic transformer calibration systems employing data acquisition cards cannot satisfy some practical applications, because the calibration systems have phase measurement errors when they work in the mode of receiving external synchronization signals. This paper proposes an improved calibration system scheme with phase correction to improve the phase measurement accuracy. We employ NI PCI-4474 to design a calibration system, and the system has the potential to receive external synchronization signals and reach extremely high accuracy classes. Accuracy verification has been carried out in the China Electric Power Research Institute, and results demonstrate that the system surpasses the accuracy class 0.05. Furthermore, this system has been used to test the harmonics measurement accuracy of all-fiber optical current transformers. In the same process, we have used an existing calibration system, and a comparison of the test results is presented. The system after improvement is suitable for the intended applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ensuring Σ s Y s = 1 in transport of species mass fractions

When transporting species mass fractions in reacting flow simulations, there are physical constraints that must be met. Unfortunately, nonlinear transport schemes such as weighted essentially non-oscillatory (WENO) schemes do not ensure that the sum of mass fractions equals 1. In detonation simulations, errors in the sum of mass fractions are observed to worsen over time when the standard WENO scheme is used. To prevent this, typically one species is forced to absorb all or most of the error in the sum of mass fractions. Here, this work presents an alternative method for correcting the WENO-interpolated mass fractions such that inert species do not change. The method is demonstrated for both argon and nitrogen-diluted hydrogen detonations in one dimension. Using the modified WENO interpolations, the error in the sum is reduced significantly. In addition, the new approach is better able to capture the physical instability expected for nitrogen-diluted detonations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Long-range corrected density functional theory with accelerated Hartree-Fock exchange integration using a two-Gaussian operator [LC-ωPBE(2Gau)]

Since the advent of hybrid functional in 1993, it has become a main quantum chemical tool for the calculation of energies and properties of molecular systems. Following the introduction of long-range corrected hybrid scheme for density functional theory a decade later, the applicability of the hybrid functional has been further amplified due to the resulting increased performance on orbital energy, excitation energy, non-linear optical property, barrier height, and so on. Nevertheless, the high cost associated with the evaluation of Hartree-Fock (HF) exchange integrals remains a bottleneck for the broader and more active applications of hybrid functionals to large molecular and periodic systems. Here, we propose a very simple yet efficient method for the computation of long-range corrected hybrid scheme. It uses a modified two-Gaussian attenuating operator instead of the error function for the long-range HF exchange integral. As a result, the two-Gaussian HF operator, which mimics the shape of the error function operator, reduces computational time dramatically (e.g., about 14 times acceleration in C diamond calculation using periodic boundary condition) and enables lower scaling with system size, while maintaining the improved features of the long-range corrected density functional theory.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of dose calculation methods for brachytherapy of intraocular tumors

Purpose: To investigate dosimetric differences among several clinical treatment planning systems (TPS) and Monte Carlo (MC) codes for brachytherapy of intraocular tumors using {sup 125}I or {sup 103}Pd plaques, and to evaluate the impact on the prescription dose of the adoption of MC codes and certain versions of a TPS (Plaque Simulator with optional modules). Methods: Three clinical brachytherapy TPS capable of intraocular brachytherapy treatment planning and two MC codes were compared. The TPS investigated were Pinnacle v8.0dp1, BrachyVision v8.1, and Plaque Simulator v5.3.9, all of which use the AAPM TG-43 formalism in water. The Plaque Simulator software can also handle some correction factors from MC simulations. The MC codes used are MCNP5 v1.40 and BrachyDose/EGSnrc. Using these TPS and MC codes, three types of calculations were performed: homogeneous medium with point sources (for the TPS only, using the 1D TG-43 dose calculation formalism); homogeneous medium with line sources (TPS with 2D TG-43 dose calculation formalism and MC codes); and plaque heterogeneity-corrected line sources (Plaque Simulator with modified 2D TG-43 dose calculation formalism and MC codes). Comparisons were made of doses calculated at points-of-interest on the plaque central-axis and at off-axis points of clinical interest within a standardized model of the right eye. Results: For the homogeneous water medium case, agreement was within {approx}2% for the point- and line-source models when comparing between TPS and between TPS and MC codes, respectively. For the heterogeneous medium case, dose differences (as calculated using the MC codes and Plaque Simulator) differ by up to 37% on the central-axis in comparison to the homogeneous water calculations. A prescription dose of 85 Gy at 5 mm depth based on calculations in a homogeneous medium delivers 76 Gy and 67 Gy for specific {sup 125}I and {sup 103}Pd sources, respectively, when accounting for COMS-plaque heterogeneities. For off-axis points-of-interest, dose differences approached factors of 7 and 12 at some positions for {sup 125}I and {sup 103}Pd, respectively. There was good agreement ({approx}3%) among MC codes and Plaque Simulator results when appropriate parameters calculated using MC codes were input into Plaque Simulator. Plaque Simulator and MC users are perhaps at risk of overdosing patients up to 20% if heterogeneity corrections are used and the prescribed dose is not modified appropriately. Conclusions: Agreement within 2% was observed among conventional brachytherapy TPS and MC codes for intraocular brachytherapy dose calculations in a homogeneous water environment. In general, the magnitude of dose errors incurred by ignoring the effect of the plaque backing and Silastic insert (i.e., by using the TG-43 approach) increased with distance from the plaque's central-axis. Considering the presence of material heterogeneities in a typical eye plaque, the best method in this study for dose calculations is a verified MC simulation.

60 APPLIED LIFE SCIENCES↗

Extended Limber approximation

We develop a systematic derivation for the Limber approximation to the angular cross-power spectrum of two random fields, as a series expansion in (l+1/2){sup -1}. This extended Limber approximation can be used to test the accuracy of the Limber approximation and to improve the rate of convergence at large l's. We show that the error in ordinary Limber approximation is O(l{sup -2}). We also provide a simple expression for the 2nd order correction to the Limber formula, which improves the accuracy to O(l{sup -4}). This correction can be especially useful for narrow redshift bins, or samples with small redshift overlap, for which the 0th order Limber formula has a large error. We also point out that using l instead of l+1/2, as is often done in the literature, spoils the accuracy of the approximation to O(l{sup -1})

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The impact of neglecting ice phase on cloud optical depth retrievals from AERONET cloud mode observations

Clouds present many challenges to climate modelling. To develop and verify the parameterisations needed to allow climate models to represent cloud structure and processes, there is a need for high-quality observations of cloud optical depth from locations around the world.Retrievals of cloud optical depth are obtainable from radiances measured by Aerosol Robotic Network (AERONET) radiometers in “cloud mode” using a two-wavelength retrieval method. However, the method is unable to detect cloud phase, and hence assumes that all of the cloud in a profile is liquid.This assumption has the potential to introduce errors into long-term statistics of retrieved optical depth for clouds that also contain ice.Using a set of idealised cloud profiles we find that, for optical depths above 20, the fractional error in retrieved optical depth is a linear function of the fraction of the optical depth that is due to the presence ofice cloud (“ice fraction”). Clouds that are entirely ice have positive errors with magnitudes of the order of 55 % to 70 %. We derive a simple linear equation that can be used as a correction at AERONET sites where ice fraction can be independently estimated. Using this linear equation, we estimate the magnitude of the error for a set of cloud profiles from five sites of the Atmospheric Radiation Measurement programme. The dataset contains separate retrievals of ice and liquid retrievals; hence ice fraction can be estimated. The magnitude of the error at each location was related to the relative frequencies of occurrence in thick frontal cloud at the mid-latitude sites and of deep convection at the tropical sites – that is, of deep cloud containing both ice and liquid particles. The long-term mean optical depth error at the five locations spans the range 2–4, which we show to be small enough to allow calculation of top-of-atmosphere flux to within 10 % and surface flux to about 15 %.

54 ENVIRONMENTAL SCIENCES↗

THE BOSS Ly{alpha} FOREST SAMPLE FROM SDSS DATA RELEASE 9

We present the BOSS Lyman-{alpha} (Ly{alpha}) Forest Sample from SDSS Data Release 9, comprising 54,468 quasar spectra with z{sub qso} > 2.15 suitable for Ly{alpha} forest analysis. This data set probes the intergalactic medium with absorption redshifts 2.0 < z{sub {alpha}} < 5.7 over an area of 3275 deg{sup 2}, and encompasses an approximate comoving volume of 20 h {sup -3} Gpc{sup 3}. With each spectrum, we have included several products designed to aid in Ly{alpha} forest analysis: improved sky masks that flag pixels where data may be unreliable, corrections for known biases in the pipeline estimated noise, masks for the cores of damped Ly{alpha} systems and corrections for their wings, and estimates of the unabsorbed continua so that the observed flux can be converted to a fractional transmission. The continua are derived using a principal component fit to the quasar spectrum redward of rest-frame Ly{alpha} ({lambda} > 1216 A), extrapolated into the forest region and normalized by a linear function to fit the expected evolution of the Ly{alpha} forest mean flux. The estimated continuum errors are {approx}< 5% rms. We also discuss possible systematics arising from uncertain spectrophotometry and artifacts in the flux calibration; global corrections for the latter are provided. Our sample provides a convenient starting point for users to analyze clustering in BOSS Ly{alpha} forest data, and it provides a fiducial data set that can be used to compare results from different analyses of baryon acoustic oscillations in the Ly{alpha} forest. The full data set is available from the SDSS-III DR9 Web site.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiotherapy margin design with particular consideration of high curvature CTVs

In applying 3D conformal radiation therapy to a tumor clinical target volume (CTV), a margin is added around the CTV to account for any sources of error in the application of treatment which may result in misalignment between the CTV and the dose distribution actually delivered. The volume enclosed within the CTV plus the margin is known as the PTV, or planning target volume. The larger the errors are anticipated to be, the wider the margin will need to be to accommodate those errors. Based on the approach of van Herk et al. [''The probability of correct target dosage: Dose-population histograms for deriving treatment margins in radiotherapy,'' Int. J. Radiat. Oncol. Biol., Phys. 47(4), 1121-1135 (2000)] this paper develops the mathematical theory behind the calculation of the margin width required to ensure that the entire CTV receives sufficiently high dose with sufficiently high probability. The margin recipe developed not only considers the magnitude of the errors but also includes a term to adjust for curved CTV surfaces. In doing so, the accuracy of the margin recipe is enhanced yet remains mathematically concise enough to be readily implemented in the clinical setting. The results are particularly relevant for clinical situations in which the uncertainties in treatment are large relative to the size of the CTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

JLEIC electron ring dynamic aperture with non-linear field errors

We present results of dynamic aperture study for the updated electron ring lattice of the Jefferson Lab Electron- Ion Collider (JLEIC). The lattice design features low emittance arcs with local compensation of sextupole nonlinear effects, and low emittance non-linear chromaticity correction sections. Dynamic aperture tracking simulations are performed to evaluate the effects of non-linear field errors, the sensitivity to betatron tune, and the impact of momentum error. Dynamic aperture is also evaluated with the measured PEP-II field errors. Preliminary tolerances to the non-linear field errors in the Final Focus quadrupoles are estimated.

Nosochkov, Yuri↗

Benchmark Calculations of Energetic Properties of Groups 4 and 6 Transition Metal Oxide Nanoclusters Including Comparison to Density Functional Theory

The heats of formation and the normalized clustering energies (NCEs) for the group 4 and group 6 transition metal oxide (TMO) trimers and tetramers have been calculated by the Feller-Peterson-Dixon (FPD) method. The heats of formation predicted by the FPD method do not differ much from those previously derived from the NCEs at the CCSD(T)/aT level except for the CrO3 nanoclusters. New and improved heats of formation for Cr3O9 and Cr4O12 were obtained using PW91 orbitals instead of Hartree-Fock (HF) orbitals. Diffuse functions are necessary to predict accurate heats of formation. The fluoride affinities (FAs) are calculated with the CCSD(T) method. The relative energies (REs) of different isomers, NCEs, electron affinities (EAs), and FAs of (MO2)n ( M = Ti, Zr, Hf, n = 1 – 4 ) and (MO3)n ( M = Cr, Mo, W, n = 1 – 3) clusters have been benchmarked with 55 exchange-correlation DFT functionals including both pure and hybrid types. The absolute errors of the DFT results are mostly less than ±10 kcal/mol for the NCEs and the EAs, and less than ±15 kcal/mol for the FAs. Hybrid functionals usually perform better than the pure functionals for the REs and NCEs. The performance of the two types of functionals in predicting EAs and FAs is comparable. The B1B95 and PBE1PBE functionals provide reliable energetic properties for most isomers. Long range corrected pure functionals usually give poor FAs. The standard deviation of the absolute error is always close to the mean errors and the probability distributions of the DFT errors are often not Gaussian (normal). The breadth of the distribution of errors and the maximum probability are dependent on the energy property and the isomer.

Environmental Molecular Sciences Laboratory↗

Utilizing physics-based input features within a machine learning model to predict wind speed forecasting error

Machine learning is quickly becoming a commonly used technique for wind speed and power forecasting. Many machine learning methods utilize exogenous variables as input features, but there remains the question of which atmospheric variables are most beneficial for forecasting, especially in handling non-linearities that lead to forecasting error. This question is addressed via creation of a hybrid model that utilizes an autoregressive integrated moving-average (ARIMA) model to make an initial wind speed forecast followed by a random forest model that attempts to predict the ARIMA forecasting error using knowledge of exogenous atmospheric variables. Variables conveying information about atmospheric stability and turbulence as well as inertial forcing are found to be useful in dealing with non-linear error prediction. Streamwise wind speed, time of day, turbulence intensity, turbulent heat flux, vertical velocity, and wind direction are found to be particularly useful when used in unison for hourly and 3 h timescales. The prediction accuracy of the developed ARIMA–random forest hybrid model is compared to that of the persistence and bias-corrected ARIMA models. The ARIMA–random forest model is shown to improve upon the latter commonly employed modeling methods, reducing hourly forecasting error by up to 5 % below that of the bias-corrected ARIMA model and achieving an R 2 value of 0.84 with true wind speed.

17 WIND ENERGY↗

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a detector. Based on our privileged access to the raw image data of an autocollimator, novel strategies to reduce the systematic measurement errors by using a set of overlapping images of the reticle obtained at different positions on the detector are discussed. It is demonstrated that imaging properties such as, for example, geometrical distortions and vignetting, can be extracted from this redundant set of images without recourse to external calibration facilities. This approach is based on the fact that the properties of the reticle itself do not change – all changes in the reticle image are due to the imaging process. Firstly, by combining interpolation and correlation, it is possible to determine the shift of a reticle image relative to a reference image with minimal error propagation. Secondly, the intensity of the reticle image is analysed as a function of its position on the CCD and a vignetting correction is calculated. Thirdly, the size of the reticle image is analysed as a function of its position and an imaging distortion correction is derived. It is demonstrated that, for different measurement ranges and aperture diameters of the autocollimator, reductions in the systematic errors of up to a factor of four to five can be achieved without recourse to external measurements.

47 OTHER INSTRUMENTATION↗

Optimal Cosmic Microwave Background Lensing Reconstruction and Parameter Estimation with SPTpol Data

Here, we perform the first simultaneous Bayesian parameter inference and optimal reconstruction of the gravitational lensing of the cosmic microwave background (CMB), using 100 deg 2 of polarization observations from the SPTpol receiver on the South Pole Telescope. These data reach noise levels as low as 5.8 μK arcmin in polarization, which are low enough that the typically used quadratic estimator (QE) technique for analyzing CMB lensing is significantly suboptimal. Conversely, the Bayesian procedure extracts all lensing information from the data and is optimal at any noise level. We infer the amplitude of the gravitational lensing potential to be ${A}_{\phi }=0.949\,\pm \,0.122$ using the Bayesian pipeline, consistent with our QE pipeline result, but with 17% smaller error bars. The Bayesian analysis also provides a simple way to account for systematic uncertainties, performing a similar job as frequentist "bias hardening" or linear bias correction, and reducing the systematic uncertainty on A Φ due to polarization calibration from almost half of the statistical error to effectively zero. Finally, we jointly constrain A Φ along with A L , the amplitude of lensing-like effects on the CMB power spectra, demonstrating that the Bayesian method can be used to easily infer parameters both from an optimal lensing reconstruction and from the delensed CMB, while exactly accounting for the correlation between the two. These results demonstrate the feasibility of the Bayesian approach on real data, and pave the way for future analysis of deep CMB polarization measurements with SPT-3G, Simons Observatory, and CMB-S4, where improvements relative to the QE can reach 1.5 times tighter constraints on A Φ and seven times lower effective lensing reconstruction noise.

79 ASTRONOMY AND ASTROPHYSICS↗

Stratospheric temperature measurements from nanosatellite stellar occultation observations of refractive bending

Abstract. Stellar occultation observations from space can probe the stratosphere and mesosphere at a fine vertical scale around the globe. Unlike other measurement techniques like radiosondes and aircraft, stellar occultation has the potential to observe the atmosphere above 30 km, and unlike radio occultation, stellar occultation probes fine-scale phenomena with potential to observe atmospheric turbulence. We imaged the refractive bending angle of a star centroid for a series of occultations by the atmosphere. Atmospheric refractivity, density, and then temperature are retrieved from the bending observations with the Abel transformation and Edlén's law, the hydrostatic equation, and the ideal gas law. The retrieval technique is applied to data collected by two nanosatellites operated by Terran Orbital. Measurements were primarily taken by the GEOStare SV2 mission, with a dedicated imaging telescope, supplemented with images captured by spacecraft bus sensors, namely the star trackers on other Terran Orbital missions. The bending angle noise floor is 10 and 30 arcsec for the star tracker and GEOStare SV2 data, respectively. The most significant sources of uncertainty are due to centroiding errors due to the fairly low-resolution stellar images and telescope pointing knowledge derived from noisy satellite attitude sensors. The former mainly affects the star tracker data, while the latter limits the GEOStare SV2 accuracy, with both providing low vertical resolution. This translates to a temperature profile retrieval up to roughly 20 km for both star tracker and GEOStare SV2 datasets. In preparation of an upcoming 2023 mission designed to correct these deficiencies, SOHIP, we simulated bending angle measurements with varying magnitudes of error. The expected maximum altitude of retrieved temperature is 41 km on average for these simulated measurements with a noise floor of 0.39 arcsec. Our work highlights the capabilities of stellar occultation observations from nanosatellites for atmospheric sounding. Future work will investigate high-frequency observations of atmospheric gravity waves and turbulence, mitigating the major uncertainties observed in these datasets.

54 ENVIRONMENTAL SCIENCES↗

Screening-Constant-by-Unit-Nuclear-Charge method investigations of high lying ({sup 1}D{sub 2},{sup 1}S{sub 0}) ns, nd Rydberg series in the photoionization spectra of the halogen-like ion Kr{sup +}

Energy positions and quantum defects of the 4s{sup 2}4p{sup 4} ({sup 1}D{sub 2},{sup 1}S{sub 0}) ns, nd Rydberg series originating from the 4s{sup 2}4p{sup 52}P{sub 3/2}{sup ∘} ground state and from the 4s{sup 2}4p{sup 52}P{sub 1/2}{sup ∘} metastable state of Kr{sup +} are reported. Calculations are performed using the Screening Constant by Unit Nuclear Charge (SCUNC) method. The results obtained are in suitable agreement with recent experimental data from the combined ASTRID merged-beam set up and Fourier Transform Ion Cyclotron Resonance device (Bizau et al., 2011), ALS measurements (Hinojosa et al., 2012), and multi-channel R-matrix eigenphase derivative calculations (McLaughlin and Balance, 2012). In addition, analysis of the 4s{sup 2}4p{sup 4}({sup 1}D{sub 2})nd and the 4s{sup 2}4p{sup 4}({sup 1}S{sub 0})nd resonances is given via the SCUNC procedure. The excellent results obtained from our work point out that the SCUNC formalism may be used to confirm the results of the analysis from the standard quantum-defect expansion formulas. Eventual errors occurring in the analysis can then be automatically detected and corrected via the SCUNC procedure.

74 ATOMIC AND MOLECULAR PHYSICS↗

Scattering amplitudes for multi-indexed extensions of solvable potentials

New solvable one-dimensional quantum mechanical scattering problems are presented. They are obtained from known solvable potentials by multiple Darboux transformations in terms of virtual and pseudo virtual wavefunctions. The same method applied to confining potentials, e.g. Pöschl–Teller and the radial oscillator potentials, has generated the multi-indexed Jacobi and Laguerre polynomials. Simple multi-indexed formulas are derived for the transmission and reflection amplitudes of several solvable potentials. -- Highlights: •Scattering amplitudes calculated for infinitely many new solvable potentials. •New scattering potentials obtained by deforming six known solvable potentials. •Multiple Darboux transformations in terms of (pseudo) virtual states employed. •Scattering amplitudes checked to obey the shape invariance relation. •Errors in scattering amplitudes of some undeformed potentials in the literature corrected.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Linear-Response Time-Dependent Embedded Mean-Field Theory

We present a time-dependent (TD) linear-response description of excited electronic states within the framework of embedded mean-field theory (EMFT). TD-EMFT allows for subsystems to be described at different mean-field levels of theory, enabling straightforward treatment of excited states and transition properties. We provide benchmark demonstrations of TD-EMFT for both local and nonlocal excitations in organic molecules, as well as applications to chlorophyll a, solvatochromic shifts of a dye in solution, and sulfur K-edge X-ray absorption spectroscopy (XAS). It is found that mixed-basis implementations of TD-EMFT lead to substantial errors in terms of transition properties; however, as previously found for ground-state EMFT, these errors are largely eliminated with the use of Fock-matrix corrections. These results indicate that TD-EMFT is a promising method for the efficient, multilevel description of excited-state electronic structure and dynamics in complex systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Refine your search to explore more results.